2000 WATT AC/DC POWER SUPPLY TXD2000 DESCRIPTION The TXD2000 Series is a flexible, modular, 2000 Watt design offering two high current outputs in a 5 x 8 x 12 package. Output voltages from 2.5 VDC through 48 VDC are standard. With Power Factor Correction, EMI compliance to FCC and CISPR22, CE Mark and immunity to EN61000-4, the TXD2000 Series is ready for global deployment. Standard features include Remote Sense Compensation, Output Voltage Adjustment, Active Current Sharing, Remote Inhibit, Power Fail Warning, DC OK Signal and Thermal Shutdown. An optional ORing diode is offered on models with an output voltage of 12 VDC or above. FEATURES T C U D t Model O R P en m E e c T r Repla E L O ctory fo S B O act Fa z Wide Range Input of 90-264VAC, 1000 Watts, High Range Input of 180-264VAC, 2000 Watts, z Harmonic Correction to EN61000-3-2 ont z Active Current Sharing C z No Load Operation z Optional ORing Diode z 70-80% Efficiencies z FCC / CISPR 22 Class A EMI Filtering z Self-Cooled 5”x 8”x 12” Chassis AGENCY APPROVALS z EN61000-4 Immunity www.murata-ps.com Technical enquiries - email: [email protected], tel: +1 508 339 3000 Input Specifications Parameters Conditions Min Typ Max Units VAC Operating Range 1000W 2000W Inrush Current 47-63Hz 90 264 47-63Hz 180 264 VAC 80 Apk 120VAC, 250C, cold start 240VAC, 250C, cold start Efficiency 160 Nominal line, full load 70 Holdup Full load 20 Power Factor (1) Full load 75 80 Apk % m sec 0.99 Notes: (1) Harmonic currents meet EN61000-3-2 Output Voltage Modules and Maximum Rated Load Output Output Voltage Voltage Code Voltage Output Current (Maximum Continuous) Output Power (Maximum Continuous) A 5.0 200A 1000W B 12.0 83A 1000W C 15.0 67A 1000W D 18.0 55A 1000W E 24.0 42A 1000W F 28.0 36A 1000W G 36.0 28A 1000W H 48.0 21A 1000W J 20.0 K 3.3 L 2.5 T C U D t Model O R P en m E e c T r Repla E L O ctory fo S B O act Fa 40A 800W 182A 600W 200A 500W t n Output Specifications Co Parameter Conditions Output Power All environmental and line conditions Min Typ 90-264VAC 180-264VAC Limited by output module selection Voltage Adjustment Range Relative to nominal output voltage Output Regulation Line, load or cross Minimum Load Max Units 1000 Watts 2000 +5 +0.2 0 PARD Measured at output terminals, 20MHz Temperature Coefficient 00 to 500C Watts % % Amps 50 mv or 1% +0.2 pk-pk %/0C Environmental Specifications Parameter Conditions Ambient Temperature (Operating) Output de-rated linearly to 50% of rated capacity between 500C and 700C Ambient Temperature Non-operating Altitude (Operating) Altitude (Non-operating) Min Typ Max Units 0 +70 0 C -50 C +85 0 -200 +10,000 Feet -200 +50,000 Feet Shock Per MIL-STD-810D, Method 516.3, Procedure II, in each axis, including NTSA drop test Vibration Per MIL-STD-810D, Method 514.3, Procedure II, in each axis, including NTSA drop test Cooling The TXD2000 is provided with internal cooling fans. www.murata-ps.com Technical enquiries - email: [email protected], tel: +1 508 339 3000 Product Features Features Characteristic Remote Sense 500mV compensation Active Current Sharing Single Wire; 5% current share if outputs are over 25% of rated load ORing Diode Optional (not available on modules below 12V) OVP 125% of nominal (+7.5%) Thermal Shutdown Automatic Restart DC OK Signal Logic “1” when output is within +3% of nominal Power Fail Warning Transition to Logic “0” at least 5msec before loss of output regulation Remote Inhibit Logic “0” applied will inhibit output (referenced to –Sense terminal) Product Compliances Approval Characteristic UL and cUL UL1950, 3rd Edition VDE EN60950 FCC Class A requirements for conducted emissions CISPR 22 Class A requirements for conducted emissions EN61000-4-2 Electrostatic Discharge, Level 4 EN61000-4-4 Electrical Fast Transients, Level 3 (1) T C U D t Model O R P en m E e c T r Repla E L Ordering Information O ctory fo S B O act Fa EN61000-4-5 Input Surge Immunity, Level 3 EN61000-3-2 Harmonic Currents, Class A CE Mark Low Voltage Directive Notes: (1) UL1950, 3 Edition incorporates the requirements of CSA 950. rd Model Designation BASE MODEL t Con TXD2000 F L L H Chassis: “8” = 5” x 8” x 12”; “M” = modified Output Voltage Module A: (see chart below) Output Voltage Module B: (see chart below) Standard Fan: “F”: Remote Inhibit - TTL Logic Level “0” turns the power supply OFF: Power Fail Warning - TTL Logic Level “0” indicates AC is LOST: ORing Diode - “D” indicates an ORing Diode is installed in each module; “N” = None: DC OK - TTL Logic Level “1” indicates DC is OK: OUTPUT VOLTAGES A = 5V G = 36V B = 12V H = 48V C = 15V J = 20V D = 18V K = 3.3V E = 24V L = 2.5V F = 28V www.murata-ps.com Technical enquiries - email: [email protected], tel: +1 508 339 3000 T C U D del O o M R ement P E T r Replac E L O ctory fo S B O act Fa t Con