ETC HPR403/H

Product Data Sheet
0.75 WATT MINIATURE SIP
DC/DC CONVERTER
HPR4XX
FEATURES
• High Isolation Voltage: 3000 VPK Test
• Single-In-Line Package (SIP)
• High Output Power Density:
10 Watts/Inch3
• Extended Temperature Range:
-25°C to +85°C
• Internal Input and Output Filtering
• Low Cost
• High Efficiency: To 79%
• Non-Conductive Case
DESCRIPTION
The HPR4XX Series uses advanced circuit design and packaging technology to realize superior reliability and performance. A
170kHz push-pull oscillator is used in the input stage. The
HPR4XX Series reduces beat-frequency oscillation problems
when used with high frequency isolation amplifiers. Reduced
parts count and high efficiency add to the reliability of the
HPR4XX Series.
The high efficiency of the HPR4XX Series means less internal
power dissipation, as low as 190mW. With less heat to dissipate
the HPR4XX Series can operate at higher temperatures with no
degradation of reliable operation. In addition, the high efficiency of the HPR4XX Series means the series is able to offer
greater than 10 W/inch3 of output power density. Operation
down to no load will not impact the reliability of the series,
although this product has a >1mA minimum load for specifications purposes.
The HPR4XX Series provides high isolation in a very small
package. The use of surface mounted devices and manufacturing technologies makes it possible to offer premium performance and low cost.
MECHANICAL
0.240±0.010"
(6.09±0.25)
0.77±0.010"
(19.56±0.25)
FRONT
VIEW
0.02±0.002"
(0.51±0.05)
5 6 7
0.18±0.015"
(4.57±0.38)
All dimensions are in inches (millimeters).
GRID: 0.100 inches (2.54 millimeters)
0.400±0.010"
(10.16±0.25)
1 2
Notes:
0.020±0.010"
(0.51±0.25)
RIGHT
SIDE
VIEW
0.010±0.002"
(0.25±0.05)
0.140"
MIN
(3.56)
PIN PLACEMENT TOLERANCE: ± 0.015"
PIN CONNECTIONS
1. +VIN
2. -VIN
5. -VOUT 6. COM*
7. +VOUT
*Common pins not present on
single output models.
0.035±0.015"
(0.89±0.38)
BOTTOM
VIEW
Internet: http://www.cdpowerelectronics.com
Power Electronics Division, United States
3400 E Britannia Drive, Tucson, Arizona 85706
Phone: 800.547.2537
Fax: 520.770.9369
HPR4XX REV F 4/99
This Material Copyrighted by Its Respective Manufacturer
Power Electronics Division, Europe
C&D Technologies (Power Electronics) Ltd.
132 Shannon Industrial Estate, Shannon, Co. Clare, Ireland
Tel: +353.61.474.133
Fax:+353.61.474.141
Page 1
ELECTRICAL SPECIFICATIONS
Specifications typical at TA = +25°C, nominal input voltage, rated output current unless otherwise specified.
NOMINAL
INPUT
VOLTAGE
RATED
OUTPUT
VOLTAGE
RATED
OUTPUT
CURRENT
INPUT CURRENT
NO LOAD
RATED LOAD
REFLECTED
RIPPLE
CURRENT
EFFICIENCY
MODEL
(VDC)
(VDC)
(mA)
(mA)
TYP
MAX
(mAp-p)
(%)
HPR400
HPR401
HPR402
HPR403
HPR404
HPR405
5
5
5
5
5
5
5
12
15
±5
±12
±15
150
62
50
±75
±30
±25
20
20
20
20
20
20
216
212
212
218
212
220
235
235
235
245
235
220
10
5
5
5
5
5
69
70
71
68
68
75
HPR406
HPR407
HPR408
HPR409
HPR410
HPR411
12
12
12
12
12
12
5
12
15
±5
±12
±15
150
62
50
±75
±30
±25
10
10
10
10
10
10
90
81
81
88
81
81
100
90
90
98
90
90
5
5
5
5
5
5
69
77
77
71
74
77
HPR412
HPR413
HPR414
HPR415
HPR416
HPR417
15
15
15
15
15
15
5
12
15
±5
±12
±15
150
62
50
±75
±30
±25
8
8
8
8
8
8
72
72
72
72
63
63
80
80
80
80
70
66
5
5
5
5
5
5
69
69
69
69
76
79
HPR418
HPR419
HPR420
HPR421
HPR422
HPR423
24
24
24
24
24
24
5
12
15
±5
±12
±15
150
62
50
±75
±30
±25
8
8
8
8
8
8
48
48
45
45
45
45
53
53
50
50
50
50
15
15
15
15
15
15
65
65
69
69
67
69
Note: Other input to output voltages may be available. Please consult factory
COMMON SPECIFICATIONS
Specifications typical at TA = +25°C, nominal input voltage, rated output current unless otherwise specified.
PARAMETER
CONDITIONS
INPUT
Voltage Range
ISOLATION
Rated Voltage
Test Voltage
Resistance
Capacitance
Leakage Current
OUTPUT
Rated Power
Voltage Setpoint Accuracy
Ripple & Noise
HPR403
Voltage
60Hz, 60 Sec
MIN
TYP
MAX
UNITS
4.5
10.8
13.5
21.6
5
12
15
24
5.5
13.2
16.5
26.4
VDC
VDC
VDC
VDC
1000
3000
10
15
2
VISO= 240VAC, 60Hz
750
.01
mW
%
mVp-p
mVrms
mVp-p
VDC
VDC
VDC
%/Deg C
High Line to Low Line
Rated Load to 1mA Load
Rated Load to 1mA Load
1
10
3
%/%Vin
%
%
Over Line and Load
170
24
2
kHz
%
g
7.9
MHr
±5
Rated Load, Nominal VIN
BW = DC to 10MHz
BW =10Hz to 2MHz
BW = DC to 10MHz
1 mA Load, VOUT = 5V
1 mA Load, VOUT= 12V
1 mA Load, VOUT = 15V
45
30
90
7
15
18
Temperature Coefficent
REGULATION
Line Regulation
Load Regulation (5V out only)
Load Regulation (All other Models)
GENERAL
Switching Frequency
Frequency Change
Package Weight
MTTF per MIL-HDBK-217, Rev. E
Ground Benign
7
VDC
Vpk
GW
pF
µArms
Circuit Stress Method
TA = +25°C
TEMPERATURE
Specification
Operation
Storage
ABSOLUTE MAXIMUM RATINGS
-25
-40
-40
+25
+85
+100
+110
°C
°C
°C
ORDERING INFORMATION
HPR
Internal Power Dissipation..................................................................450mW
Short Circuit Duration....................................................................Momentary
Lead Temperature (soldering, 10 seconds max)................................+300°C
Page 2
This Material Copyrighted by Its Respective Manufacturer
4 XX
/H
Device Family
HPR Indicates DC/DC converter
Model Number
Selected from Table of Electrical Characteristics
Screening Option
HPR4XX REV F 4/99
TYPICAL PERFORMANCE CURVES
Specifications typical at TA = +25°C, nominal input voltage, rated output current unless otherwise specified.
VOUT VS LOAD
(5Vout Models)
VOUT VS LOAD
(±5Vout Models)
5.7
5.4
5.5
5.2
VOUT VS LOAD
(12Vout Models)
12.5
5.3
12.3
Vout
Vout
Vout
12.4
5.0
12.2
12.1
5.1
4.8
4.9
4.6
12.0
0
80
40
120
11.9
160
0
20
Output Current (mA)
40
60
0
80
Output Current each load (mA)
VOUT VS LOAD
(±12Vout Models)
VOUT VS LOAD
(15Vout Models)
12.6
60
80
VOUT VS LOAD
(±15Vout Models)
16.0
15.7
12.4
15.5
12.3
15.5
Vout
Vout
Vout
40
16.5
15.9
12.5
15.0
12.2
15.3
14.5
12.1
15.1
14.0
12.0
14.9
0
10
20
30
13.5
0
40
20
40
60
80
Output Current each load (mA)
Output Current each load (mA)
EFFICIENCY VS LOAD
OSCILLATION FREQUENCY VS
TEMPERATURE
90
0
0.2
0.4
0.6
0.8
1.0
Output Power each load (Watts)
220
Frequency (KHz)
75
Efficiency (%)
20
Output Current each load (mA)
60
45
30
15
0
20
0
40
200
180
160
140
60
80
-30
100
0
% of Rated Load (%)
30
60
90
Temperature (°C)
SAFE OPERATING AREA
LOAD CAPACITANCE vs INPUT RISE TIME
(5 Vout models)
600
50
Total Load Capacitance (uF)
Total Load Capacitance (uF)
500
400
300
SAFE OPERATING AREA
200
40
30
SAFE OPERATING AREA
20
10
100
0
0
0
5
10
15
20
25
30
35
Rise Time of Input Voltage (mS)
40
45
5
10
15
20
25
30
35
40
45
50
Rise Time of Input Voltage (mS)
NOTES:
LOAD CAPACITANCE vs INPUT RISE TIME
(12 Vout models)
1.) When operated within the SAFE OPERATING AREA as defined
by the above curves, the output voltage of HPR4XX devices is
guaranteed to be within 95% of its steady-state value within 100
milliseconds after the input voltage has reached 95% of its steadystate value.
80
70
60
50
SAFE OPERATING AREA
40
0
50
90
Total Load Capacitance (uF)
LOAD CAPACITANCE vs INPUT RISE TIME
(15 Vout models)
60
2.) For dual output models, total load capacitance is the sum of the
capacitances on the plus and minus outputs.
30
20
10
0
0
5
10
15
20
25
30
35
40
45
50
Rise Time of Input Voltage (mS)
HPR4XX REV F 4/99
This Material Copyrighted by Its Respective Manufacturer
Page 3