Product Data Sheet 0.75 WATT MINIATURE SIP DC/DC CONVERTER HPR4XX FEATURES • High Isolation Voltage: 3000 VPK Test • Single-In-Line Package (SIP) • High Output Power Density: 10 Watts/Inch3 • Extended Temperature Range: -25°C to +85°C • Internal Input and Output Filtering • Low Cost • High Efficiency: To 79% • Non-Conductive Case DESCRIPTION The HPR4XX Series uses advanced circuit design and packaging technology to realize superior reliability and performance. A 170kHz push-pull oscillator is used in the input stage. The HPR4XX Series reduces beat-frequency oscillation problems when used with high frequency isolation amplifiers. Reduced parts count and high efficiency add to the reliability of the HPR4XX Series. The high efficiency of the HPR4XX Series means less internal power dissipation, as low as 190mW. With less heat to dissipate the HPR4XX Series can operate at higher temperatures with no degradation of reliable operation. In addition, the high efficiency of the HPR4XX Series means the series is able to offer greater than 10 W/inch3 of output power density. Operation down to no load will not impact the reliability of the series, although this product has a >1mA minimum load for specifications purposes. The HPR4XX Series provides high isolation in a very small package. The use of surface mounted devices and manufacturing technologies makes it possible to offer premium performance and low cost. MECHANICAL 0.240±0.010" (6.09±0.25) 0.77±0.010" (19.56±0.25) FRONT VIEW 0.02±0.002" (0.51±0.05) 5 6 7 0.18±0.015" (4.57±0.38) All dimensions are in inches (millimeters). GRID: 0.100 inches (2.54 millimeters) 0.400±0.010" (10.16±0.25) 1 2 Notes: 0.020±0.010" (0.51±0.25) RIGHT SIDE VIEW 0.010±0.002" (0.25±0.05) 0.140" MIN (3.56) PIN PLACEMENT TOLERANCE: ± 0.015" PIN CONNECTIONS 1. +VIN 2. -VIN 5. -VOUT 6. COM* 7. +VOUT *Common pins not present on single output models. 0.035±0.015" (0.89±0.38) BOTTOM VIEW Internet: http://www.cdpowerelectronics.com Power Electronics Division, United States 3400 E Britannia Drive, Tucson, Arizona 85706 Phone: 800.547.2537 Fax: 520.770.9369 HPR4XX REV F 4/99 This Material Copyrighted by Its Respective Manufacturer Power Electronics Division, Europe C&D Technologies (Power Electronics) Ltd. 132 Shannon Industrial Estate, Shannon, Co. Clare, Ireland Tel: +353.61.474.133 Fax:+353.61.474.141 Page 1 ELECTRICAL SPECIFICATIONS Specifications typical at TA = +25°C, nominal input voltage, rated output current unless otherwise specified. NOMINAL INPUT VOLTAGE RATED OUTPUT VOLTAGE RATED OUTPUT CURRENT INPUT CURRENT NO LOAD RATED LOAD REFLECTED RIPPLE CURRENT EFFICIENCY MODEL (VDC) (VDC) (mA) (mA) TYP MAX (mAp-p) (%) HPR400 HPR401 HPR402 HPR403 HPR404 HPR405 5 5 5 5 5 5 5 12 15 ±5 ±12 ±15 150 62 50 ±75 ±30 ±25 20 20 20 20 20 20 216 212 212 218 212 220 235 235 235 245 235 220 10 5 5 5 5 5 69 70 71 68 68 75 HPR406 HPR407 HPR408 HPR409 HPR410 HPR411 12 12 12 12 12 12 5 12 15 ±5 ±12 ±15 150 62 50 ±75 ±30 ±25 10 10 10 10 10 10 90 81 81 88 81 81 100 90 90 98 90 90 5 5 5 5 5 5 69 77 77 71 74 77 HPR412 HPR413 HPR414 HPR415 HPR416 HPR417 15 15 15 15 15 15 5 12 15 ±5 ±12 ±15 150 62 50 ±75 ±30 ±25 8 8 8 8 8 8 72 72 72 72 63 63 80 80 80 80 70 66 5 5 5 5 5 5 69 69 69 69 76 79 HPR418 HPR419 HPR420 HPR421 HPR422 HPR423 24 24 24 24 24 24 5 12 15 ±5 ±12 ±15 150 62 50 ±75 ±30 ±25 8 8 8 8 8 8 48 48 45 45 45 45 53 53 50 50 50 50 15 15 15 15 15 15 65 65 69 69 67 69 Note: Other input to output voltages may be available. Please consult factory COMMON SPECIFICATIONS Specifications typical at TA = +25°C, nominal input voltage, rated output current unless otherwise specified. PARAMETER CONDITIONS INPUT Voltage Range ISOLATION Rated Voltage Test Voltage Resistance Capacitance Leakage Current OUTPUT Rated Power Voltage Setpoint Accuracy Ripple & Noise HPR403 Voltage 60Hz, 60 Sec MIN TYP MAX UNITS 4.5 10.8 13.5 21.6 5 12 15 24 5.5 13.2 16.5 26.4 VDC VDC VDC VDC 1000 3000 10 15 2 VISO= 240VAC, 60Hz 750 .01 mW % mVp-p mVrms mVp-p VDC VDC VDC %/Deg C High Line to Low Line Rated Load to 1mA Load Rated Load to 1mA Load 1 10 3 %/%Vin % % Over Line and Load 170 24 2 kHz % g 7.9 MHr ±5 Rated Load, Nominal VIN BW = DC to 10MHz BW =10Hz to 2MHz BW = DC to 10MHz 1 mA Load, VOUT = 5V 1 mA Load, VOUT= 12V 1 mA Load, VOUT = 15V 45 30 90 7 15 18 Temperature Coefficent REGULATION Line Regulation Load Regulation (5V out only) Load Regulation (All other Models) GENERAL Switching Frequency Frequency Change Package Weight MTTF per MIL-HDBK-217, Rev. E Ground Benign 7 VDC Vpk GW pF µArms Circuit Stress Method TA = +25°C TEMPERATURE Specification Operation Storage ABSOLUTE MAXIMUM RATINGS -25 -40 -40 +25 +85 +100 +110 °C °C °C ORDERING INFORMATION HPR Internal Power Dissipation..................................................................450mW Short Circuit Duration....................................................................Momentary Lead Temperature (soldering, 10 seconds max)................................+300°C Page 2 This Material Copyrighted by Its Respective Manufacturer 4 XX /H Device Family HPR Indicates DC/DC converter Model Number Selected from Table of Electrical Characteristics Screening Option HPR4XX REV F 4/99 TYPICAL PERFORMANCE CURVES Specifications typical at TA = +25°C, nominal input voltage, rated output current unless otherwise specified. VOUT VS LOAD (5Vout Models) VOUT VS LOAD (±5Vout Models) 5.7 5.4 5.5 5.2 VOUT VS LOAD (12Vout Models) 12.5 5.3 12.3 Vout Vout Vout 12.4 5.0 12.2 12.1 5.1 4.8 4.9 4.6 12.0 0 80 40 120 11.9 160 0 20 Output Current (mA) 40 60 0 80 Output Current each load (mA) VOUT VS LOAD (±12Vout Models) VOUT VS LOAD (15Vout Models) 12.6 60 80 VOUT VS LOAD (±15Vout Models) 16.0 15.7 12.4 15.5 12.3 15.5 Vout Vout Vout 40 16.5 15.9 12.5 15.0 12.2 15.3 14.5 12.1 15.1 14.0 12.0 14.9 0 10 20 30 13.5 0 40 20 40 60 80 Output Current each load (mA) Output Current each load (mA) EFFICIENCY VS LOAD OSCILLATION FREQUENCY VS TEMPERATURE 90 0 0.2 0.4 0.6 0.8 1.0 Output Power each load (Watts) 220 Frequency (KHz) 75 Efficiency (%) 20 Output Current each load (mA) 60 45 30 15 0 20 0 40 200 180 160 140 60 80 -30 100 0 % of Rated Load (%) 30 60 90 Temperature (°C) SAFE OPERATING AREA LOAD CAPACITANCE vs INPUT RISE TIME (5 Vout models) 600 50 Total Load Capacitance (uF) Total Load Capacitance (uF) 500 400 300 SAFE OPERATING AREA 200 40 30 SAFE OPERATING AREA 20 10 100 0 0 0 5 10 15 20 25 30 35 Rise Time of Input Voltage (mS) 40 45 5 10 15 20 25 30 35 40 45 50 Rise Time of Input Voltage (mS) NOTES: LOAD CAPACITANCE vs INPUT RISE TIME (12 Vout models) 1.) When operated within the SAFE OPERATING AREA as defined by the above curves, the output voltage of HPR4XX devices is guaranteed to be within 95% of its steady-state value within 100 milliseconds after the input voltage has reached 95% of its steadystate value. 80 70 60 50 SAFE OPERATING AREA 40 0 50 90 Total Load Capacitance (uF) LOAD CAPACITANCE vs INPUT RISE TIME (15 Vout models) 60 2.) For dual output models, total load capacitance is the sum of the capacitances on the plus and minus outputs. 30 20 10 0 0 5 10 15 20 25 30 35 40 45 50 Rise Time of Input Voltage (mS) HPR4XX REV F 4/99 This Material Copyrighted by Its Respective Manufacturer Page 3