® MKW10M SERIES DC/DC CONVERTER 10W, Reinforced Insulation, Medical Safety FEATURES ►4200VAC reinforced Insulation ►Insulation rated for 300VAC Working Voltage ►Medical Safety to UL/CSA/EN/IEC 60601-1 3rd Edition ►2 MOOP rated ►Wide 2:1 Input Voltage Range ►Fully regulated Output Voltage ►Low Leakage Current ►Operating Temp. Range –40°C to +75 °C ►Input Filter meets EN 55022,class A and FCC, level A ►Overload Protection ►2”x 1” Plastic Package ►3 Years Product Warranty PRODUCT OVERVIEW The MINMAX MKW10M series is a new range of high performance DC/DC converter modules with a reinforced insulation system .The I/O- isolation voltage is specified for 4200VACrms.The product comes in a compact 2”x1” industry standard package. All 15 models features wide 2:1 input voltage range and fully regulated output voltage.The MKW10M DC/DC converters offer an economical solution for demanding applications in industrial and medical instrumentation requesting a certified supplementary or reinforced insulation system to comply with industrial or latest medical safety standards. Model Selection Guide Model Number MKW10-12S05M MKW10-12S051M MKW10-12S12M MKW10-12D12M MKW10-12D15M MKW10-24S05M MKW10-24S051M MKW10-24S12M MKW10-24D12M MKW10-24D15M MKW10-48S05M MKW10-48S051M MKW10-48S12M MKW10-48D12M MKW10-48D15M Input Voltage (Range) Output Voltage VDC VDC 5 5.1 12 ±12 ±15 5 5.1 12 ±12 ±15 5 5.1 12 ±12 ±15 12 (9 ~ 18) 24 (18 ~ 36) 48 (36 ~ 75) Output Current Input Current Max. @Max. Load @No Load Reflected Ripple Current mA 1600 1600 835 ±417 ±333 2000 2000 835 ±417 ±333 2000 2000 835 ±417 ±333 mA(typ.) 907 907 1044 1042 1028 559 559 516 516 508 280 280 258 258 254 mA (typ.) mA(typ.) Max. capacitive Load μ F @Max. Load 1000 30 100 470 220# 1000 20 50 470 220# 1000 10 25 Efficiency (typ.) 470 220# % 74 75 80 80 81 75 76 81 81 82 75 76 81 81 82 # For each output Input Specifications Parameter Model 12V Input Models 24V Input Models 48V Input Models 12V Input Models 24V Input Models 48V Input Models 12V Input Models 24V Input Models 48V Input Models Input Surge Voltage (1 sec. max.) Start-Up Threshold Voltage Under Voltage Shutdown Short Circuit Input Power Internal Power Dissipation Conducted EMI All Models E-mail:[email protected] 2014/09/23 REV:3 Tel:886-6-2923150 Page 1 of 4 Min. Typ. Max. Unit -0.7 25 ---0.7 50 ---0.7 100 --7 8 9 13 15 18 VDC 30 33 36 ----8.5 ----16 ----34 ----3000 mW ----4000 mW Compliance to EN 55022,class A and FCC part 15,class A ® MKW10M SERIES DC/DC CONVERTER 10W, Reinforced Insulation, Medical Safety Output Specifications Parameter Output Voltage Setting Accuracy Output Voltage Balance Line Regulation Load Regulation Ripple & Noise Min.Load Over Load Protection Transient Recovery Time Transient Response Deviation Temperature Coefficient Short Circuit Protection Conditions Min. Typ. Max. ----±1.0 Dual Output, Balanced Loads --±0.5 ±2.0 Vin=Min. to Max. --±0.3 ±0.5 Io=15% to 100% --±0.5 ±1.0 Io=5% to 100% --±0.6 ±1.2 5V & 5.1V Output Models ----100 0-20 MHz Bandwidth Other Output Models ----150 No minimum Load Requirement 120 150 ----300 600 25% Load Step Change --±3 ±5 --±0.02 ±0.05 Continuous Unit %Vnom. % % % % mV P-P mV P-P % μ sec % %/℃ Isolation, Safety Standards Parameter I/O Isolation Voltage (reinforced) Leakage Current Conditions Min. Typ. Max. Unit 60 Seconds 4200 --- --- VACrms 240VAC, 60Hz --- --- 10 μ A I/O Isolation Resistance 500 VDC 10 --- --- GΩ I/O Isolation Capacitance 100KHz, 1V 80 pF Safety Standards Approvals --60 cUL/UL60950-1, CSA C22.2 No. 60950-1-03 UL60601-1,CSA C22.2 No.601-1, IEC/EN 60950-1, IEC/EN 60601-1 3rd Edition, 2 MOOP IEC60950-1 CB report, cUL/UL 60950-1 certificate UL60601-1 UL certificate General Specifications Parameter Conditions Min. Typ. Max. Unit MIL-HDBK-217F@25℃, Ground Benign 120 1,000,000 150 --- 180 --- KHz Hours Conditions Min. Max. Unit Natural Convection -40 +75 ℃ Case Temperature --- +95 ℃ Storage Temperature Range -50 +125 ℃ Humidity (non condensing) --- 95 % rel. H --- 4000 m 260 ℃ Switching Frequency MTBF(calculated) Environmental Specifications Parameter Operating Ambient Temperature Range (See Power Derating Curve) Altitude Cooling Free-Air convection Lead Temperature (1.5mm from case for 10Sec.) --- E-mail:[email protected] 2014/09/23 REV:3 Tel:886-6-2923150 Page 2 of 4 ® MKW10M SERIES DC/DC CONVERTER 10W, Reinforced Insulation, Medical Safety Power Derating Curve 100 Natural Convection 20LFM Output Power (%) 80 100LFM 60 200LFM 400LFM 40 20 0 ~ -40 0 20 40 60 80 100 110 Ambient Temperature C Notes 1 2 3 4 5 6 Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted. Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%. We recommend to protect the converter by a slow blow fuse in the input supply line. Other input and output voltage may be available, please contact factory. That “natural convection” is about 20LFM but is not equal to still air (0 LFM). Specifications are subject to change without notice. Package Specifications Mechanical Dimensions Pin Connections 5.08 [0.20] 5.08 [0.20] Bottom View 5 4 Pin Single Output Dual Output 1 +Vin +Vin 2 -Vin -Vin 3 +Vout +Vout 4 No Pin Common 5 -Vout -Vout 50.8 [2.00] 1.00 [ 0.04] 1 45.72 [1.80] 2 12.0 [0.47] ► All dimensions in mm (inches) 3 ► Tolerance: X.X±0.25 (X.XX±0.01) 10.16 [0.40] 10.16 [0.40] 2.54 [0.10] 25.4 [1.00] Physical Characteristics Case Size : 50.8x25.4x12.0mm (2.0x1.0x0.47 inches) Case Material : Non-Conductive Black Plastic (flammability to UL 94V-0 rated) Pin Material : Copper Alloy with Gold Plate Over Nickel Subplate Weight : 24.5g E-mail:[email protected] 2014/09/23 REV:3 Tel:886-6-2923150 Page 3 of 4 X.XX±0.13 ( X.XXX±0.005) ► Pin diameter 1.0 ±0.05 (0.04±0.002) ® MKW10M SERIES DC/DC CONVERTER 10W, Reinforced Insulation, Medical Safety Test Setup Input Reflected-Ripple Current Test Setup Input reflected-ripple current is measured with a inductor Lin (4.7μ H) and Cin (220μ F, ESR < 1.0Ω at 100 KHz) to simulate source impedance. Capacitor Cin, offsets possible battery impedance. Current ripple is measured at the input terminals of the module, measurement bandwidth is 0-500 KHz. To Oscilloscope + + Battery +Vin Lin DC / DC Converter Current Probe Cin +Out -Vin Load -Out Peak-to-Peak Output Noise Measurement Test Use a Cout 0.47μ F ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load between 50 mm and 75 mm from the DC/DC Converter. +Vin +Out Copper Strip Single Output DC / DC Converter -Vin Cout -Out Scope +Vin +Out Copper Strip Dual Output DC / DC Converter Com. Copper Strip -Vin -Out Resistive Load Copper Strip Scope Cout Cout Resistive Load Scope Copper Strip Technical Notes Input Source Impedance The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module. In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor on the input to insure startup. By using a good quality low Equivalent Series Resistance (ESR < 1.0Ω at 100 kHz) capacitor of a 10μ F for the 12V input devices and a 4.7μ F for the 24V input devices and a 2.2μ F for the 48V devices, capacitor mounted close to the power module helps ensure stability of the unit. + DC Power Source +Vin + +Out DC / DC Converter Load Cin - -Vin -Out Output Ripple Reduction A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is recommended to use 3.3μ F capacitors at the output. + +Vin DC Power Source - +Out Single Output DC / DC Converter -Vin + Cout +Vin DC Power Source Load -Out - +Out Dual Output DC / DC Com. Converter -Vin -Out Cout Load Load Cout Maximum Capacitive Load The MKW10M series has limitation of maximum connected capacitance on the output. The power module may operate in current limiting mode during start-up, affecting the ramp-up and the startup time. Connect capacitors at the point of load for best performance. The maximum capacitance can be found in the data sheet. Thermal Considerations Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the maximum temperature rating of the components inside the power module, the case temperature must be kept below 95℃. The derating curves are determined from measurements obtained in a test setup. Position of air velocity probe and thermocouple 15mm / 0.6in 50mm / 2in Air Flow DUT 18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan Tel: 886-6-2923150 Fax: 886-6-2923149 E-mail: [email protected] Minmax Technology Co., Ltd. 2014/09/23 REV:3 Page 4 of 4