MSHU100 SERIES DC/DC CONVERTER 2W, Reinforced Insulation, Medical Safety FEATURES ►Industrial Standard SMD Package ►I/O Isolation 4000VAC with Reinforced Insulation, rated for 300VAC Working Voltage ►Low Leakage Current < 2μA ►Operating Ambient Temp. Range -25℃ to +80℃ ►Qualified for Lead-free Reflow Solder Process According to IPC/JEDEC J-STD-020D.1 ►Tape & Reel Package Available ►Medical EMC Standard meet EMI EN55011 and EMS EN60601-1-2 ►Medical Safety meets 2xMOOP per 3rd Edition of IEC/EN 60601-1 & ANSI/AAMI ES60601-1 ►UL/cUL/IEC/EN 60950-1 Safety Approval & CE Marking PRODUCT OVERVIEW The MINMAX MSHU100 series is a new range of 2W DC/DC-converter modules providing a very high I/O-isolation voltage of 4000 VAC. The product comes in a small SMD-package. There are 15 models available with 5V, 12V or 24VDC input and single-or dual-output voltages. The MSHU100 DC/DC converters offer an economical solution for many applications in instrumentation, industrial controls, medical equipment and everywhere where a certified supplementary- or reinforced insulation system is required to comply with requested safety standards. Model Selection Guide Model Number Input Voltage (Range) Output Voltage Max. Min. @Max. Load @No Load VDC VDC mA mA mA(typ.) mA(typ.) 5 400 8 606 12 165 3 600 15 133 2.5 605 MSHU102 MSHU104 MSHU105 MSHU108 5 (4.5 ~ 5.5) Output Current Input Current Load Regulation Max. capacitive Load % (max.) μF @Max. Load 12 ±83 ±1.5 553 10 ±15 ±66 ±1 542 10 MSHU112 5 400 8 253 12 MSHU114 12 165 3 250 10 15 133 2.5 252 ±12 ±83 ±1.5 224 10 MSHU119 ±15 ±66 ±1 220 10 MSHU122 5 400 8 126 12 12 165 3 125 15 133 2.5 126 ±12 ±83 ±1.5 112 10 ±15 ±66 ±1 110 10 MSHU118 MSHU124 MSHU125 MSHU128 12 (10.8 ~ 13.2) 24 (21.6 ~ 26.4) MSHU129 330 10 ±12 40 66 66 100# 72 73 66 330 10 66 66 100# 74 75 66 10 30 % 66 10 90 MSHU109 MSHU115 Efficiency (typ.) 330 10 66 66 100# 74 75 # For each output Input Specifications Parameter Input Voltage Range Input Surge Voltage (1 sec. max.) Input Filter Min. Typ. Max. 4.5 5 5.5 12V Input Models 10.8 12 13.2 24V Input Models 21.6 24 26.4 5V Input Models -0.7 --- 9 12V Input Models -0.7 --- 18 24V Input Models -0.7 --- 30 All Models E-mail:[email protected] 2016/03/31 Model 5V Input Models REV:16 Tel:886-6-2923150 Page 1 of 4 Internal Capacitor Unit VDC MSHU100 SERIES DC/DC CONVERTER 2W, Reinforced Insulation, Medical Safety Output Specifications Parameter Conditions Output Voltage Setting Accuracy Min. Typ. Max. Unit --- ±2.0 ±4.0 %Vnom. Output Voltage Balance Dual Output, Balanced Loads --- ±0.1 ±1.0 % Line Regulation Vin=Min. to Max. @Full Load --- ±1.2 ±1.5 % Load Regulation Io=20% to 100% Ripple & Noise 0-20 MHz Bandwidth See Model Selection Guide Temperature Coefficient Short Circuit Protection --- --- 150 mV P-P --- ±0.01 ±0.02 %/℃ 0.5 Second Max., Automatic Recovery Isolation, Safety Standards Parameter I/O Isolation Voltage Conditions Min. Typ. Max. Unit Reinforced Insulation, Rated For 60 Seconds 4000 --- --- VACrms Flash tested for 1 Second 6000 --- --- VPK I/O Isolation Test Voltage Leakage Current 240VAC, 60Hz --- --- 2 μA I/O Isolation Resistance 500 VDC 10 --- --- GΩ I/O Isolation Capacitance 100KHz, 1V --- 15 20 pF UL/cUL 60950-1, CSA C22.2 No 60950-1 Safety Standards ANSI/AAMI ES60601-1, CAN/CSA-C22.2 No. 60601-1 IEC/EN 60950-1, IEC/EN 60601-1 3rd Edition 2xMOOP UL/cUL 60950-1 recognition (UL certificate), IEC/EN 60950-1 (CB-report) Safety Approvals ANSI/AAMI ES60601-1 2xMOOP recognition (UL certificate), IEC/EN 60601-1 3rd Edition (CB-report) General Specifications Parameter Conditions Min. Switching Frequency 50 MTBF (calculated) MIL-HDBK-217F@25℃, Ground Benign Moisture Sensitivity Level (MSL) Typ. Max. 80 100 2,000,000 IPC/JEDEC J-STD-020D.1 Unit KHz Hours Level 2 Environmental Specifications Parameter Operating Ambient Temperature Range (See Power Derating Curve) Conditions Min. Max. Unit Natural Convection -25 +80 ℃ ℃ Case Temperature --- +90 Storage Temperature Range -50 +125 ℃ Humidity (non condensing) --- 95 % rel. H Cooling Natural Convection Lead-free Refiow Solder Process IPC/JEDEC J-STD-020D.1 Power Derating Curve 100 Natural convection 20LFM Output Power (%) 80 400LFM 60 40 20 0 ~ -25 0 20 40 60 Ambient Temperature C E-mail:[email protected] 2016/03/31 REV:16 Tel:886-6-2923150 Page 2 of 4 80 100 110 MSHU100 SERIES DC/DC CONVERTER 2W, Reinforced Insulation, Medical Safety Notes 1 2 3 4 5 6 7 Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted. These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage these modules; however they may not meet all specifications listed. We recommend to protect the converter by a slow blow fuse in the input supply line. Other input and output voltage may be available, please contact factory. That “natural convection” is about 20LFM but is not equal to still air (0 LFM). It is not recommended to use water-washing process on SMT units. Specifications are subject to change without notice. Package Specifications Mechanical Dimensions Connecting Pin Patterns 24.0 [0.94] 17.78 [0.70] 8 1 10.6 [0.42] 4.3 [0.17] 0° ~4 ° 2.54 [0.10] 0.15 S 7 ►All dimensions in mm (inches) 8 ►Tolerance: X.X±0.5 (X.XX±0.02) Bottom View X.XX±0.25 ( X.XXX±0.01) 16 10 9 ►Pins ±0.05 (±0.002) Single Output Dual Output 1 -Vin -Vin 7 NC NC 8 NC Common 9 +Vout +Vout 10 -Vout -Vout 16 +Vin +Vin NC: No Connection E-mail:[email protected] 2016/03/31 1.6 [0.06] SEATING PLANE 1.5 [ 0.06] 1 Pin Connections Pin S 9.25 0.5 [0.36 0.02] 0.25 [0.01] 9.0 [0.35] 2.9 1.00 [0.04] 19.5 [0.77] 7 Top View [0.11] 9 16.6 [0.65] 10 13.7 [0.54] 16 13.7 [0.54] 2.54 [0.1] 15.24 [0.6] 18.1 [0.71] 3.11 [0.12] REV:16 Tel:886-6-2923150 Page 3 of 4 Physical Characteristics Case Size : 24.0x13.7x9.0mm (0.94x0.54x0.35 inches) Case Material : Non-Conductive Black Plastic (flammability to UL 94V-0 rated) Pin Material : Phosphor bronze Weight : 3.75g MSHU100 SERIES DC/DC CONVERTER 2W, Reinforced Insulation, Medical Safety Test Setup Peak-to-Peak Output Noise Measurement Test Use a Cout 0.47μF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load between 50 mm and 75 mm from the DC/DC Converter. +Vin +Out Copper Strip Single Output DC / DC Converter -Vin Cout -Out Scope Resistive Load Copper Strip +Vin +Out Copper Strip Dual Output DC / DC Converter Com. Copper Strip -Vin -Out Scope Cout Resistive Load Cout Scope Copper Strip Technical Notes Maximum Capacitive Load The MSHU100 series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up, affecting the ramp-up and the startup time. For optimum performance we recommend 100μF maximum capacitive load for dual outputs and 330μF capacitive load for single outputs. The maximum capacitance can be found in the data sheet. Input Source Impedance The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module. In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup. Capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to use a good quality low Equivalent Series Resistance (ESR < 1.0Ω at 100 KHz) capacitor of a 2.2μF for the 5V input devices, a 1.0μF for the 12V input devices and a 0.47μF for the 24V input devices. + DC Power Source +Vin + +Out DC / DC Converter Load Cin - -Vin -Out Output Ripple Reduction A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is recommended to use 3.3μF capacitors at the output. + +Vin - +Out Single Output DC / DC Converter DC Power Source -Vin + Cout Load -Out +Vin DC Power Source - +Out Dual Output DC / DC Com. Converter -Vin -Out Cout Load Load Cout Thermal Considerations Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the maximum temperature rating of the components inside the power module, the case temperature must be kept below 90℃. The derating curves are determined from measurements obtained in a test setup. Position of air velocity probe and thermocouple 15mm / 0.6in 50mm / 2in Air Flow DUT 18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan Tel: 886-6-2923150 Fax: 886-6-2923149 E-mail: [email protected] Minmax Technology Co., Ltd. 2016/03/31 REV:16 Page 4 of 4