MSLU400 SERIES DC/DC CONVERTER 2W, SMD-Package FEATURES ►Industrial SMD Package ►I/O Isolation 1500 VDC ►Operating Ambient Temp. Range -40℃ to +90℃ ►Water-washable Process Available ►Qualified for Lead-free Reflow Solder Process According to IPC/JEDEC J-STD-020D.1 ►Tape & Reel Package Available PRODUCT OVERVIEW The MINMAX MSLU400 series is a range of 2W DC/DC converters in a SMD- Package featuring I/O-isolation of 1500VDC. The very small footprint makes this product the ideal solution for many applications where a voltage has to be isolated i.e for noise reduction, ground loop elimination, in digital interfaces or where a converted voltage is required. An excellent efficiency allows an operating temperature range of -40°C to +85°C. With a new package design these, converters are fully qualified for the higher temperature profile used in lead-free reflow solder processes. For automated SMD production lines, the product can be supplied in tape & reel package. Model Selection Guide Model Number MSLU401 MSLU402 MSLU404 MSLU406 MSLU408 MSLU409 MSLU411 MSLU412 MSLU414 MSLU418 MSLU419 MSLU421 MSLU422 MSLU424 MSLU428 MSLU429 Input Voltage (Range) Output Voltage VDC VDC 3.3 5 12 ±5 ±12 ±15 3.3 5 12 ±12 ±15 3.3 5 12 ±12 ±15 5 (4.5 ~ 5.5) 12 (10.8 ~ 13.2) 24 (21.6 ~ 26.4) Output Current Input Current Load Regulation Max. Min. @Max. Load @No Load mA 500 400 165 ±200 ±83 ±66 500 400 165 ±83 ±66 500 400 165 ±83 ±66 mA 10 8 3 ±4 ±1.5 ±1 10 8 3 ±1.5 ±1 10 8 3 ±1.5 ±1 mA(typ.) 471 548 514 541 524 521 191 222 209 208 206 96 111 105 105 104 mA(typ.) 60 30 15 Max. capacitive Load Efficiency (typ.) @Max. Load % (max.) 11 11 11 10 7 7 8 8 5 5 5 8 8 5 5 5 μF 47 47 10 10# 4.7# 4.7# 47 47 10 4.7# 4.7# 47 47 10 4.7# 4.7# # For each output % 70 73 77 74 76 76 72 75 79 80 80 72 75 79 79 79 Input Specifications Parameter Model 5V Input Models 12V Input Models 24V Input Models 5V Input Models 12V Input Models 24V Input Models All Models Input Voltage Range Input Surge Voltage (1 sec. max.) Input Filter E-mail:[email protected] 2015/07/31 REV:10 Tel:886-6-2923150 Page 1 of 6 Min. 4.5 10.8 21.6 -0.7 -0.7 -0.7 Typ. Max. 5 5.5 12 13.2 24 26.4 --9 --18 --30 Internal Capacitor Unit VDC MSLU400 SERIES DC/DC CONVERTER 2W, SMD-Package Output Specifications Parameter Conditions Min. Typ. Max. Unit Dual Output, Balanced Loads --- ±0.1 ±1.0 % Line Regulation For Vin Change of 1% --- ±1.2 ±1.5 % Load Regulation Io=20% to 100% Ripple & Noise 0-20 MHz Bandwidth Output Voltage Balance See Model Selection Guide Temperature Coefficient Short Circuit Protection --- --- 120 mV P-P --- ±0.01 ±0.02 %/℃ 0.5 Second Max., Automatic Recovery General Specifications Parameter I/O Isolation Voltage Conditions Min. Typ. Max. Unit 60 Seconds 1500 --- --- VDC 1 Second 1800 --- --- VDC I/O Isolation Resistance 500 VDC 1000 --- --- MΩ I/O Isolation Capacitance 100KHz, 1V --- 60 100 pF 100 120 Switching Frequency 50 MTBF (calculated) MIL-HDBK-217F@25℃, Ground Benign Moisture Sensitivity Level (MSL) 2,000,000 IPC/JEDEC J-STD-020D.1 KHz Hours Level 2 Environmental Specifications Parameter Operating Ambient Temperature Range (See Power Derating Curve) Conditions Min. Max. Unit Natural Convection -40 +85 ℃ Case Temperature --- +90 ℃ Storage Temperature Range -50 +125 ℃ --- 95 % rel. H Humidity (non condensing) Cooling Lead-free Reflow Solder Process Natural Convection IPC/JEDEC J-STD-020D.1 +20% +20% +20% +20% +15% +15% +15% +15% +10% +10% +10% Max. +5% +5% Typ. Vnom Vnom Min. -5% -5% -10% 0% 20% 40% 80% -10% 100% +10% Max. +5% +5% Typ. Vnom Vnom Min. -5% -5% -10% 0% 20% 40% 60% Output Load Current (%) Output Load Current (%) (3.3V & 5V Output) (All other Output) E-mail:[email protected] 2015/07/31 REV:10 60% Output Voltage(%) Output Voltage(%) Output Voltage Tolerance Tel:886-6-2923150 Page 2 of 6 80% -10% 100% MSLU400 SERIES DC/DC CONVERTER 2W, SMD-Package Power Derating Curve 100 Natural Convection 20LFM Output Power (%) 80 400LFM 60 40 20 0 ~ -40 0 20 40 60 80 100 110 Ambient Temperature ℃ Notes 1 2 3 4 5 6 Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted. These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage these modules; however they may not meet all specifications listed. We recommend to protect the converter by a fast blow fuse in the input supply line. Other input and output voltage may be available, please contact factory. That “natural convection” is about 20LFM but is not equal to still air (0 LFM). Specifications are subject to change without notice. E-mail:[email protected] 2015/07/31 REV:10 Tel:886-6-2923150 Page 3 of 6 MSLU400 SERIES DC/DC CONVERTER 2W, SMD-Package Package Specifications Mechanical Dimensions (Single Ouput) Connecting Pin Patterns 7.62 [0.30] 9.3 [0.37] ( Magnification of A ) 5.08 [0.2] 13.7 [0.54] 8.9 0.5 [0.35 0.02] S 1.5 0.1 [0.06 0.004] 0.3 [0.01] 8.6 [0.34] 2.54 [0.10] 0.60 [0.02] 6.15 [0.24] 6.15 [0.24] 13.7 [0.54] 11.5 [0.45] 0~ 4 4 2.2 [0.09] 2.54 [0.1] 2 5 1 R 0. 9.3 [0.37] Top View 12.3 [0.48] 5 8 0.25 [0.01] 3.04 [0.12] 1.2 [0.05] SEATING PLANE 1.5 0.1 [0.06 0.004] 0.1 S Package Specifications Mechanical Dimensions (Dual Output) Connecting Pin Patterns 5.08 [0.2] 16.3 [0.64] 9.3 [0.37] 11.5 [0.45] 0.25 [0.01] 0~ 4 5 R 0. 5 4 2.2 [0.09] 2.54 [0.1] 2 9.3 [0.37] Top View 1 12.3 [0.48] 7 10 ( Magnification of A ) 2.54 [0.1] 8.9 0.5 [0.35 0.02] 0.3 [0.01] 8.6 [0.34] 2.54 [0.10] 0.60 [0.02] 13.7 [0.54] 7.62 [0.30] 3.07 [0.12] 1.2 [0.05] S SEATING PLANE 1.5 0.1 [0.06 0.004] 6.15 [0.24] 6.15 [0.24] ►All dimensions in mm (inches) 1.5 0.1 [0.06 0.004] 0.1 S ►Tolerance: X.X±0.25 (X.XX±0.01) X.XX±0.13 ( X.XXX±0.005) ► Pins ±0.05(±0.002) Pin Connections Physical Characteristics Pin Single Output Dual Output Case Size (Single Output) : 13.7x9.3x8.6mm (0.54x0.37x0.34 inches) 1 -Vin -Vin Case Size (Dual Output) : 16.3x9.3x8.6mm (0.64x0.37x0.34 inches) 2 +Vin +Vin 4 -Vout Common Case Material : Non-Conductive Black Plastic (flammability to UL 94V-0 rated) 5 +Vout -Vout 7 No Pin +Vout Pin Material : Phosphor bronze 8 NA No Pin 10 No Pin NA Weight (Single Output) : 1.5g Weight (Dual Output) : 2.2g NA : Not Available for Electrical Connection E-mail:[email protected] 2015/07/31 REV:10 Tel:886-6-2923150 Page 4 of 6 MSLU400 SERIES DC/DC CONVERTER 2W, SMD-Package Order Code Table Standard MSLU401 MSLU402 MSLU404 MSLU406 MSLU408 MSLU409 MSLU411 MSLU412 MSLU414 MSLU418 MSLU419 MSLU421 MSLU422 MSLU424 MSLU428 MSLU429 E-mail:[email protected] 2015/07/31 REV:10 Tel:886-6-2923150 Page 5 of 6 For water-washable process MSLU401-W MSLU402-W MSLU404-W MSLU406-W MSLU408-W MSLU409-W MSLU411-W MSLU412-W MSLU414-W MSLU418-W MSLU419-W MSLU421-W MSLU422-W MSLU424-W MSLU428-W MSLU429-W MSLU400 SERIES DC/DC CONVERTER 2W, SMD-Package Test Setup Peak-to-Peak Output Noise Measurement Test Use a Cout 0.33μF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load between 50 mm and 75 mm from the DC/DC Converter. +Vin +Out Copper Strip Single Output DC / DC Converter -Vin Cout -Out Scope Resistive Load Copper Strip +Vin +Out Copper Strip Dual Output DC / DC Converter Com. Copper Strip -Vin -Out Scope Cout Resistive Load Cout Scope Copper Strip Technical Notes Maximum Capacitive Load The MSLU400 series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up, affecting the ramp-up and the startup time. The maximum capacitance can be found in the data sheet. Input Source Impedance The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module. In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup. Capacitor mounted close to the power module helps ensure stability of the unit, it is comended to use a good quality low Equivalent Series Resistance (ESR < 1.0Ω at 100 KHz) capacitor of a 2.2μF for the 5V input devices, a 1.0μF for the 12V input devices and a 0.47μF for the 24V devices. + DC Power Source +Vin + +Out DC / DC Converter Load Cin - -Vin -Out Output Ripple Reduction A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is recommended to use 1.5μF capacitors at the output. + +Vin DC Power Source - +Out Single Output DC / DC Converter -Vin + Cout Load -Out +Vin DC Power Source - +Out Dual Output DC / DC Com. Converter -Vin -Out Cout Load Load Cout Thermal Considerations Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the maximum temperature rating of the components inside the power module, the case temperature must be kept below 90℃. The derating curves are determined from measurements obtained in a test setup. Position of air velocity probe and thermocouple 15mm / 0.6in 50mm / 2in Air Flow DUT 18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan Tel: 886-6-2923150 Fax: 886-6-2923149 E-mail: [email protected] Minmax Technology Co., Ltd. 2015/07/31 REV:10 Page 6 of 6