MAEU02-HI SERIES DC/DC CONVERTER 2W, Ultra-High I/O Isolation, SIP Package FEATURES ►Industrial Standard SIP-7 Package ►Ultra-high I/O Isolation 5200VDC ►Common Mode Transient Immunity : 15KV/µs ►Qualified for IGBT and High Isolation Applications ►Operating Temp. Range -40℃ to +88℃ ►UL/cUL/IEC/EN 60950-1 Safety Approval(Pending) PRODUCT OVERVIEW The MINMAX MAEU02-HI series is a new range of isolated 2W DC/DC converter modules in SIP-7 package which feature a very high I/O-isolation voltage rated for 5700VDC. A very high common mode transient immunity with 15KV/μs qualifies these product for IGBT driver applications. There are 40 models available for 5, 12, 15 and 24V input. These converters offer a cost-effective solution for wind turbine, solar panel, transporation systems, industrial control equipments and some IGBT driver applications where a very high I/O-isolation is required. Model Selection Guide Input Voltage (Range) VDC Model Number MAEU02-05S033HI MAEU02-05S05HI MAEU02-05S09HI MAEU02-05S12HI MAEU02-05S15HI MAEU02-05D05HI MAEU02-05D09HI MAEU02-05D12HI MAEU02-05D15HI Output Voltage VDC 3.3 5 9 12 15 ±5 ±9 ±12 ±15 15 -9 3.3 5 9 12 15 ±5 ±9 ±12 ±15 15 -9 3.3 5 9 12 15 ±5 ±9 ±12 ±15 15 -9 3.3 5 9 12 15 ±5 ±9 ±12 ±15 15 -9 5 ±10% MAEU02-05A1509HI MAEU02-12S033HI MAEU02-12S05HI MAEU02-12S09HI MAEU02-12S12HI MAEU02-12S15HI MAEU02-12D05HI MAEU02-12D09HI MAEU02-12D12HI MAEU02-12D15HI 12 ±10% MAEU02-12A1509HI MAEU02-15S033HI MAEU02-15S05HI MAEU02-15S09HI MAEU02-15S12HI MAEU02-15S15HI MAEU02-15D05HI MAEU02-15D09HI MAEU02-15D12HI MAEU02-15D15HI 15 ±10% MAEU02-15A1509HI MAEU02-24S033HI MAEU02-24S05HI MAEU02-24S09HI MAEU02-24S12HI MAEU02-24S15HI MAEU02-24D05HI MAEU02-24D09HI MAEU02-24D12HI MAEU02-24D15HI 24 ±10% MAEU02-24A1509HI E-mail:[email protected] 2015/05/22 P6 Output Current Max. Min. @Max. Load @No Load mA 500 400 222 168 132 ±200 ±112 ±84 ±66 66 -110 500 400 222 168 132 ±200 ±112 ±84 ±66 66 -110 500 400 222 168 132 ±200 ±112 ±84 ±66 66 -110 500 400 222 168 132 ±200 ±112 ±84 ±66 66 -110 mA 10 8 4.4 3.4 2.6 ±4 ±2.2 ±1.7 ±1.3 1.3 -2.2 10 8 4.4 3.4 2.6 ±4 ±2.2 ±1.7 ±1.3 1.3 -2.2 10 8 4.4 3.4 2.6 ±4 ±2.2 ±1.7 ±1.3 1.3 -2.2 10 8 4.4 3.4 2.6 ±4 ±2.2 ±1.7 ±1.3 1.3 -2.2 mA(typ.) 446 500 493 492 501 513 504 504 501 mA(typ.) Tel:886-6-2923150 Page 1 of 4 Input Current 35 Load Regulation Max. capacitive Load Efficiency (typ.) @Max. Load % (max.) 20 15 10 10 10 15 10 10 10 μF 1650 940 940 440 440 440# 440# 200# 200# 200 440 1650 940 940 440 440 440# 440# 200# 200# 200 440 1650 940 940 440 440 440# 440# 200# 200# 200 440 1650 940 940 440 440 440# 440# 200# 200# 200 440 # For each output % 74 80 81 82 79 78 80 80 79 495 10 181 211 206 202 201 211 207 205 199 20 15 10 10 10 15 10 10 10 17 204 10 143 169 160 162 155 165 160 164 161 20 15 10 10 10 15 10 10 10 16 159 10 90 108 103 102 101 108 104 104 103 20 15 10 10 10 15 10 10 10 102 12 10 80 76 79 81 83 82 79 81 82 83 81 77 79 83 83 85 81 84 82 82 83 76 77 81 82 82 77 81 81 80 81 MAEU02-HI SERIES DC/DC CONVERTER 2W, Ultra-High I/O Isolation, SIP Package Input Specifications Parameter Model 5V Input Models 12V Input Models 15V Input Models 24V Input Models 5V Input Models 12V Input Models 15V Input Models 24V Input Models Input Surge Voltage (1 sec. max.) Input Voltage Range Short Circuit Input Power Input Filter Min. -0.7 -0.7 -0.7 -0.7 4.5 10.8 13.5 21.6 --- All Models Typ. Max. 9 --18 --20 --30 --5 5.5 12 13.2 15 16.5 24 26.4 --1000 Internal Capacitor Type Unit VDC mW Output Specifications Parameter Output Voltage Accuracy Output Voltage Balance Line Regulation Load Regulation Ripple & Noise Temperature Coefficient Short Circuit Protection Conditions Dual Output, Balanced Loads For Vin Change of 1% Io=20% to 100% 0-20MHz Bandwidth Min. ------- Typ. --±0.1 ±1.2 Max. ±5.0 ±1.0 --- See Model Selection Guide ----100 --±0.01 ±0.02 Continuous, Automatic Recovery Unit % % % mV P-P %/℃ Isolation, Safety Standards Parameter Conditions Rated for 60 seconds Tested for 1 second 500 VDC 100KHz, 1V I/O Isolation Voltage I/O Isolation Resistance I/O Isolation Capacitance Common Mode Transient Immunity Min. 5200 5700 10 --15 Typ. ------7 --- Max. ----------- Unit VDC VDC GΩ pF KV/μs UL/cUL 60950-1 recognition(CSA certificate), IEC/EN 60950-1(CB-report) Safety Approvals(Pending) General Specifications Parameter Conditions Switching Frequency MIL-HDBK-217F@25℃, Ground Benign MTBF(calculated) Min. Typ. Max. Unit --- 100 --- KHz TBD --- --- Hours Environmental Specifications Parameter Operating Ambient Temperature Range (See Power Derating Curve) Case Temperature Storage Temperature Range Humidity (non condensing) Cooling Lead Temperature (1.5mm from case for 10Sec.) E-mail:[email protected] 2015/05/22 P6 Tel:886-6-2923150 Page 2 of 4 Conditions Min. Max. Unit Natural Convection -40 +80 ℃ ---55 --- +95 +125 95 ℃ ℃ % rel. H 260 ℃ Natural Convection --- MAEU02-HI SERIES DC/DC CONVERTER 2W, Ultra-High I/O Isolation, SIP Package Power Derating Curve Notes 1 Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted. 2 These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage these modules; 3 We recommend to protect the converter by a slow blow fuse in the input supply line. however they may not meet all specifications listed. 4 Other input and output voltage may be available, please contact factory. 5 That “natural convection” is about 20LFM but is not equal to still air (0 LFM). 6 Specifications are subject to change without notice. Package Specifications Mechanical Dimensions Pin Connections 0.5 [0.02] 10.2 [0.40] 3.2 [0.13] 0.5 [0.02] 19.5 [0.77] 2.54 [0.10] 7.62 [0.30] Pin Single Output Dual Output 1 +Vin +Vin 2 -Vin -Vin 5 -Vout -Vout 6 No Pin Common 7 +Vout +Vout 2X2.54 2X[0.10] 7.1 [0.28] 18.5 [0.73] Bottom View 7 0.50 [0.02] 2.0 [0.08] 6 0.25 [0.01] 5 2 1 Physical Characteristics Case Size : Case Material : Non-Conductive Black Plastic (flammability to UL 94V-0 rated) Pin Material : Weight : Tinned Copper TBD E-mail:[email protected] 2015/05/22 P6 19.5x7.1x10.2mm (0.77x0.28x0.40 inches) Tel:886-6-2923150 Page 3 of 4 ►All dimensions in mm (inches) ►Tolerance: X.X±0.5 (X.XX±0.02) X.XX±0.25 ( X.XXX±0.01) ►Pins ±0.05(±0.002) MAEU02-HI SERIES DC/DC CONVERTER 2W, Ultra-High I/O Isolation, SIP Package Test Setup Peak-to-Peak Output Noise Measurement Test Use a Cout 0.33μF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load between 50 mm and 75 mm from the DC/DC Converter. +Vin +Out Copper Strip Single Output DC / DC Converter -Vin Cout -Out Scope Resistive Load Copper Strip +Vin +Out Copper Strip Dual Output DC / DC Converter Com. Copper Strip -Vin -Out Scope Cout Resistive Load Cout Scope Copper Strip Technical Notes Maximum Capacitive Load The MAEU02-HI series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up, affecting the ramp-up and the startup time. The maximum capacitance can be found in the data sheet. Input Source Impedance The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module. In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup. Capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to use a good quality low Equivalent Series Resistance (ESR < 1.0Ω at 100 KHz) capacitor of a 2.2μF for the 5V input devices, a 1.0μF for the 12V,15V input devices and a 0.47μF for the 24V devices. + DC Power Source +Vin + +Out DC / DC Converter Load Cin - -Vin -Out Output Ripple Reduction A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is recommended to use 1.0μF capacitors at the output. + +Vin DC Power Source - + DC Power Source - +Out Single Output DC / DC Converter -Vin + Cout Load - + Out + Vin Dual Output DC / DC Com. Converter Cout1 Load1 - Vin Cout2 Load2 +Out Dual Output DC / DC Com. Converter DC Power Source -Out - Out +Vin -Vin -Out Cout Load Load Cout Thermal Considerations Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the maximum temperature rating of the components inside the power module, the case temperature must be kept below 100℃. The derating curves are determined from measurements obtained in a test setup. Position of air velocity probe and thermocouple 15mm / 0.6in 50mm / 2in Air Flow DUT 18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan Tel: 886-6-2923150 Fax: 886-6-2923149 E-mail: [email protected] Minmax Technology Co., Ltd. 2015/05/22 P6 Page 4 of 4