MAEU02-HI SERIES - MINMAX Technology

MAEU02-HI SERIES
DC/DC CONVERTER 2W, Ultra-High I/O Isolation, SIP Package
FEATURES
►Industrial Standard SIP-7 Package
►Ultra-high I/O Isolation 5200VDC
►Common Mode Transient Immunity : 15KV/µs
►Qualified for IGBT and High Isolation Applications
►Operating Temp. Range -40℃ to +88℃
►UL/cUL/IEC/EN 60950-1 Safety Approval(Pending)
PRODUCT OVERVIEW
The MINMAX MAEU02-HI series is a new range of isolated 2W DC/DC converter modules in SIP-7 package which feature a very high I/O-isolation voltage
rated for 5700VDC. A very high common mode transient immunity with 15KV/μs qualifies these product for IGBT driver applications. There are 40 models
available for 5, 12, 15 and 24V input. These converters offer a cost-effective solution for wind turbine, solar panel, transporation systems, industrial control
equipments and some IGBT driver applications where a very high I/O-isolation is required.
Model Selection Guide
Input
Voltage
(Range)
VDC
Model
Number
MAEU02-05S033HI
MAEU02-05S05HI
MAEU02-05S09HI
MAEU02-05S12HI
MAEU02-05S15HI
MAEU02-05D05HI
MAEU02-05D09HI
MAEU02-05D12HI
MAEU02-05D15HI
Output
Voltage
VDC
3.3
5
9
12
15
±5
±9
±12
±15
15
-9
3.3
5
9
12
15
±5
±9
±12
±15
15
-9
3.3
5
9
12
15
±5
±9
±12
±15
15
-9
3.3
5
9
12
15
±5
±9
±12
±15
15
-9
5 ±10%
MAEU02-05A1509HI
MAEU02-12S033HI
MAEU02-12S05HI
MAEU02-12S09HI
MAEU02-12S12HI
MAEU02-12S15HI
MAEU02-12D05HI
MAEU02-12D09HI
MAEU02-12D12HI
MAEU02-12D15HI
12 ±10%
MAEU02-12A1509HI
MAEU02-15S033HI
MAEU02-15S05HI
MAEU02-15S09HI
MAEU02-15S12HI
MAEU02-15S15HI
MAEU02-15D05HI
MAEU02-15D09HI
MAEU02-15D12HI
MAEU02-15D15HI
15 ±10%
MAEU02-15A1509HI
MAEU02-24S033HI
MAEU02-24S05HI
MAEU02-24S09HI
MAEU02-24S12HI
MAEU02-24S15HI
MAEU02-24D05HI
MAEU02-24D09HI
MAEU02-24D12HI
MAEU02-24D15HI
24 ±10%
MAEU02-24A1509HI
E-mail:[email protected]
2015/05/22
P6
Output Current
Max.
Min.
@Max. Load
@No Load
mA
500
400
222
168
132
±200
±112
±84
±66
66
-110
500
400
222
168
132
±200
±112
±84
±66
66
-110
500
400
222
168
132
±200
±112
±84
±66
66
-110
500
400
222
168
132
±200
±112
±84
±66
66
-110
mA
10
8
4.4
3.4
2.6
±4
±2.2
±1.7
±1.3
1.3
-2.2
10
8
4.4
3.4
2.6
±4
±2.2
±1.7
±1.3
1.3
-2.2
10
8
4.4
3.4
2.6
±4
±2.2
±1.7
±1.3
1.3
-2.2
10
8
4.4
3.4
2.6
±4
±2.2
±1.7
±1.3
1.3
-2.2
mA(typ.)
446
500
493
492
501
513
504
504
501
mA(typ.)
Tel:886-6-2923150
Page 1 of 4
Input Current
35
Load
Regulation
Max. capacitive
Load
Efficiency
(typ.)
@Max. Load
% (max.)
20
15
10
10
10
15
10
10
10
μF
1650
940
940
440
440
440#
440#
200#
200#
200
440
1650
940
940
440
440
440#
440#
200#
200#
200
440
1650
940
940
440
440
440#
440#
200#
200#
200
440
1650
940
940
440
440
440#
440#
200#
200#
200
440
# For each output
%
74
80
81
82
79
78
80
80
79
495
10
181
211
206
202
201
211
207
205
199
20
15
10
10
10
15
10
10
10
17
204
10
143
169
160
162
155
165
160
164
161
20
15
10
10
10
15
10
10
10
16
159
10
90
108
103
102
101
108
104
104
103
20
15
10
10
10
15
10
10
10
102
12
10
80
76
79
81
83
82
79
81
82
83
81
77
79
83
83
85
81
84
82
82
83
76
77
81
82
82
77
81
81
80
81
MAEU02-HI SERIES
DC/DC CONVERTER 2W, Ultra-High I/O Isolation, SIP Package
Input Specifications
Parameter
Model
5V Input Models
12V Input Models
15V Input Models
24V Input Models
5V Input Models
12V Input Models
15V Input Models
24V Input Models
Input Surge Voltage (1 sec. max.)
Input Voltage Range
Short Circuit Input Power
Input Filter
Min.
-0.7
-0.7
-0.7
-0.7
4.5
10.8
13.5
21.6
---
All Models
Typ.
Max.
9
--18
--20
--30
--5
5.5
12
13.2
15
16.5
24
26.4
--1000
Internal Capacitor Type
Unit
VDC
mW
Output Specifications
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Ripple & Noise
Temperature Coefficient
Short Circuit Protection
Conditions
Dual Output, Balanced Loads
For Vin Change of 1%
Io=20% to 100%
0-20MHz Bandwidth
Min.
-------
Typ.
--±0.1
±1.2
Max.
±5.0
±1.0
---
See Model Selection Guide
----100
--±0.01
±0.02
Continuous, Automatic Recovery
Unit
%
%
%
mV P-P
%/℃
Isolation, Safety Standards
Parameter
Conditions
Rated for 60 seconds
Tested for 1 second
500 VDC
100KHz, 1V
I/O Isolation Voltage
I/O Isolation Resistance
I/O Isolation Capacitance
Common Mode Transient Immunity
Min.
5200
5700
10
--15
Typ.
------7
---
Max.
-----------
Unit
VDC
VDC
GΩ
pF
KV/μs
UL/cUL 60950-1 recognition(CSA certificate), IEC/EN 60950-1(CB-report)
Safety Approvals(Pending)
General Specifications
Parameter
Conditions
Switching Frequency
MIL-HDBK-217F@25℃, Ground Benign
MTBF(calculated)
Min.
Typ.
Max.
Unit
---
100
---
KHz
TBD
---
---
Hours
Environmental Specifications
Parameter
Operating Ambient Temperature Range
(See Power Derating Curve)
Case Temperature
Storage Temperature Range
Humidity (non condensing)
Cooling
Lead Temperature (1.5mm from case for 10Sec.)
E-mail:[email protected]
2015/05/22
P6
Tel:886-6-2923150
Page 2 of 4
Conditions
Min.
Max.
Unit
Natural Convection
-40
+80
℃
---55
---
+95
+125
95
℃
℃
% rel. H
260
℃
Natural Convection
---
MAEU02-HI SERIES
DC/DC CONVERTER 2W, Ultra-High I/O Isolation, SIP Package
Power Derating Curve
Notes
1
Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted.
2
These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage these modules;
3
We recommend to protect the converter by a slow blow fuse in the input supply line.
however they may not meet all specifications listed.
4
Other input and output voltage may be available, please contact factory.
5
That “natural convection” is about 20LFM but is not equal to still air (0 LFM).
6
Specifications are subject to change without notice.
Package Specifications
Mechanical Dimensions
Pin Connections
0.5
[0.02]
10.2 [0.40]
3.2
[0.13]
0.5 [0.02]
19.5 [0.77]
2.54
[0.10]
7.62
[0.30]
Pin
Single Output
Dual Output
1
+Vin
+Vin
2
-Vin
-Vin
5
-Vout
-Vout
6
No Pin
Common
7
+Vout
+Vout
2X2.54
2X[0.10]
7.1 [0.28]
18.5 [0.73]
Bottom View
7
0.50 [0.02]
2.0 [0.08]
6
0.25 [0.01]
5
2
1
Physical Characteristics
Case Size
:
Case Material
:
Non-Conductive Black Plastic (flammability to UL 94V-0 rated)
Pin Material
:
Weight
:
Tinned Copper
TBD
E-mail:[email protected]
2015/05/22
P6
19.5x7.1x10.2mm (0.77x0.28x0.40 inches)
Tel:886-6-2923150
Page 3 of 4
►All dimensions in mm (inches)
►Tolerance: X.X±0.5 (X.XX±0.02)
X.XX±0.25 ( X.XXX±0.01)
►Pins ±0.05(±0.002)
MAEU02-HI SERIES
DC/DC CONVERTER 2W, Ultra-High I/O Isolation, SIP Package
Test Setup
Peak-to-Peak Output Noise Measurement Test
Use a Cout 0.33μF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load between
50 mm and 75 mm from the DC/DC Converter.
+Vin
+Out
Copper Strip
Single Output
DC / DC
Converter
-Vin
Cout
-Out
Scope
Resistive
Load
Copper Strip
+Vin
+Out
Copper Strip
Dual Output
DC / DC
Converter
Com.
Copper Strip
-Vin
-Out
Scope
Cout
Resistive
Load
Cout
Scope
Copper Strip
Technical Notes
Maximum Capacitive Load
The MAEU02-HI series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up,
affecting the ramp-up and the startup time. The maximum capacitance can be found in the data sheet.
Input Source Impedance
The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module. In
applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup.
Capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to use a good quality low Equivalent Series Resistance (ESR <
1.0Ω at 100 KHz) capacitor of a 2.2μF for the 5V input devices, a 1.0μF for the 12V,15V input devices and a 0.47μF for the 24V devices.
+
DC Power
Source
+Vin
+
+Out
DC / DC
Converter
Load
Cin
-
-Vin
-Out
Output Ripple Reduction
A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is
recommended to use 1.0μF capacitors at the output.
+
+Vin
DC Power
Source
-
+
DC Power
Source
-
+Out
Single Output
DC / DC
Converter
-Vin
+
Cout
Load
-
+ Out
+ Vin
Dual Output
DC / DC Com.
Converter
Cout1
Load1
- Vin
Cout2
Load2
+Out
Dual Output
DC / DC Com.
Converter
DC Power
Source
-Out
- Out
+Vin
-Vin
-Out
Cout
Load
Load
Cout
Thermal Considerations
Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the
maximum temperature rating of the components inside the power module, the case temperature must be kept below 100℃. The derating curves are determined from
measurements obtained in a test setup.
Position of air velocity
probe and thermocouple
15mm / 0.6in
50mm / 2in
Air Flow
DUT
18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan
Tel: 886-6-2923150 Fax: 886-6-2923149 E-mail: [email protected]
Minmax Technology Co., Ltd.
2015/05/22
P6