® MIE06-HI SERIES DC/DC CONVERTER 6W, Ultra-high I/O lsolation, DIP Package FEATURES ►Industrial Standard DIP-24 Package ►Wide 2:1 Input Voltage Range ►Fully Regulated Output Voltage ►Ultra-high I/O Isolation 8000VDC with Reinforced Insulation, rate for 1000VAC Working Voltage ►Common Mode Transient Immunity: 15KV/μs ►Qualified for IGBT and High Isolation Applications ►Operating Ambient Temp. Range -40°C to +75°C ►Overload and Short Circuit Protection ►Designed-in Conducted EMI meets EN55022 Class A & FCC Level A ►UL/cUL/IEC/EN 60950-1 Safety Approval & CE Marking PRODUCT OVERVIEW The MINMAX MIE06-HI series is a new range of isolated 6W DC/DC converter modules in DIP-24 package which feature a wide input range, fully regulated output and Ultra-high I/O Isolation voltage rated for 8000VDC with reinforced insulation. A very high common mode transient immunity with 15KV/μs qualifies these product for IGBT driver applications. Further features include overload protection, short circuit protection and EN55022 class A compliant as well. There are 12 Models available for 12, 24 and 48VDC input. These converters offer a cost-effective solution for wind turbine, solar panel, transporation systems, industrial control equipments and some IGBT driver applications where a very high I/O-isolation is required. Model Selection Guide Model Number MIE06-12S05HI MIE06-12S12HI MIE06-12D12HI MIE06-12D15HI MIE06-24S05HI MIE06-24S12HI MIE06-24D12HI MIE06-24D15HI MIE06-48S05HI MIE06-48S12HI MIE06-48D12HI MIE06-48D15HI Input Voltage (Range) Output Voltage VDC VDC 5 12 ±12 ±15 5 12 ±12 ±15 5 12 ±12 ±15 12 (9 ~ 18) 24 (18 ~ 36) 48 (36 ~ 75) Output Current Input Current Max. Min. @Max. Load @No Load Reflected Ripple Current mA 1000 500 ±250 ±200 1000 500 ±250 ±200 1000 500 ±250 ±200 mA 200 100 ±50 ±40 200 100 ±50 ±40 200 100 ±50 ±40 mA(typ.) 563 649 641 641 274 316 313 313 137 158 156 156 mA(typ.) mA (typ.) 30 60 20 30 10 15 Max. capacitive Load μF 1000 470 220# 220# 1000 470 220# 220# 1000 470 220# 220# Efficiency (typ.) @Max. Load % 74 77 78 78 76 79 80 80 76 79 80 80 # For each output Input Specifications Parameter Model 12V Input Models 24V Input Models 48V Input Models 12V Input Models 24V Input Models 48V Input Models 12V Input Models 24V Input Models 48V Input Models Input Surge Voltage (1 sec. max.) Start-Up Threshold Voltage Under Voltage Shutdown Short Circuit Input Power Input Filter Conducted EMI All Models E-mail:[email protected] 2016/06/07 P5 Tel:886-6-2923150 Page 1 of 4 Min. -0.7 -0.7 -0.7 7 13 30 --------- Typ. Max. Unit 25 50 100 9 18 VDC 36 8.5 16 34 3000 mW Internal Pi Type Compliance to EN55022,class A and FCC part 15,class A ------8 15 33 --------- ® MIE06-HI SERIES DC/DC CONVERTER 6W, Ultra-high I/O lsolation, DIP Package Output Specifications Parameter Conditions / Model Output Voltage Setting Accuracy Min. Typ. Max. Unit --- --- ±1.0 %Vnom. Output Voltage Balance Dual Output, Balanced Loads --- ±0.5 ±2.0 % Line Regulation Vin=Min. to Max. @Full Load --- ±0.3 ±0.5 % Load Regulation Io=25% to 100% --- ±0.5 ±1.0 % 5V Output Models --- 75 100 mV P-P Other Output Models --- 100 150 mV P-P --- 300 500 μsec --- ±3 ±6 % --- ±0.02 ±0.05 %/℃ 120 150 --- % Min. Typ. Max. Unit 4000 --- --- VACrms Ripple & Noise 0-20 MHz Bandwidth Transient Recovery Time 25% Load Step Change Transient Response Deviation Temperature Coefficient Over Load Protection Foldback Short Circuit Protection Continuous, Automatic Recovery Isolation, Safety Standards Parameter Conditions 60 Seconds Reinforced insulation, rated for 1000VAC working voltage Tested for 1 second I/O Isolation Voltage I/O Isolation Resistance I/O Isolation Capacitance Common Mode Transient Immunity 8000 --- --- VDC 500 VDC 10 --- --- GΩ 100KHz, 1V --15 7 --- 13 --- pF KV/μs UL/cUL 60950-1 recognition(UL certificate), IEC/EN 60950-1(CB-report) Safety Approvals General Specifications Parameter Conditions Min. Switching Frequency --- MTBF(calculated) MIL-HDBK-217F@25℃, Ground Benign Typ. Max. 150 --- 700,000 Unit KHz Hours Environmental Specifications Parameter Operating Ambient Temperature Range (See Power Derating Curve) Conditions Min. Max. Unit Natural Convection -40 +75 ℃ ℃ Case Temperature --- +95 Storage Temperature Range -50 +125 ℃ Humidity (non condensing) --- 95 % rel. H 260 ℃ Cooling Natural Convection Lead Temperature (1.5mm from case for 10Sec.) E-mail:[email protected] 2016/06/07 P5 Tel:886-6-2923150 Page 2 of 4 --- ® MIE06-HI SERIES DC/DC CONVERTER 6W, Ultra-high I/O lsolation, DIP Package Power Derating Curve 100 Natural Convection 20LFM Output Power (%) 80 100LFM 60 200LFM 400LFM 40 20 0 ~ -40 0 20 40 60 80 100 110 Ambient Temperature C Notes 1 2 3 4 5 6 7 Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted. Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%. These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage these modules; however, they may not meet all specifications listed. We recommend to protect the converter by a slow blow fuse in the input supply line. Other input and output voltage may be available, please contact factory. That “natural convection” is about 20LFM but is not equal to still air (0 LFM). Specifications are subject to change without notice. Package Specifications 0.5 [0.02] Pin Connections 3.8 12.0 [0.47] [0.15] Mechanical Dimensions 0.60 [0.024] Bottom View 15 23 20.32 [0.80] 2.54 [0.10] 31.8 [1.25] Dual Output +Vin 11 No Pin Common 12 -Vout No Pin 13 +Vout -Vout 15 No Pin +Vout 23 -Vin -Vin 24 -Vin -Vin 13 5.08 [0.20] 2.0 [0.08] 2.54 [0.10] 24 +Vin 12 15.22 [0.60] 11 Single Output 1 20.3 [0.80] 1 Pin ►All dimensions in mm (inches) ►Tolerance: X.X±0.5 (X.XX±0.02) X.XX±0.25 ( X.XXX±0.01) ►Pins ±0.05(±0.002) Physical Characteristics Case Size : 31.8x20.3x12.0mm (1.25x0.8x0.47 inches) Case Material : Non-Conductive Black Plastic (flammability to UL 94V-0 rated) Pin Material : Copper Alloy with Gold Plate Over Nickel Subplate Weight : 18g E-mail:[email protected] 2016/06/07 P5 Tel:886-6-2923150 Page 3 of 4 ® MIE06-HI SERIES DC/DC CONVERTER 6W, Ultra-high I/O lsolation, DIP Package Test Setup Input Reflected-Ripple Current Test Setup Input reflected-ripple current is measured with a inductor Lin (4.7μH) and Cin (220μF, ESR < 1.0Ω at 100 KHz) to simulate source impedance. Capacitor Cin, offsets possible battery impedance. Current ripple is measured at the input terminals of the module, measurement bandwidth is 0-500 KHz. To Oscilloscope + + +Vin Lin DC / DC Converter Current Probe Cin Battery +Out -Vin Load -Out Peak-to-Peak Output Noise Measurement Test Use a Cout 0.47μF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load between 50 mm and 75 mm from the DC/DC Converter. +Out +Vin Copper Strip Single Output DC / DC Converter -Out -Vin Resistive Load Scope Cout +Out Dual Output DC / DC Converter Com. -Vin Copper Strip Copper Strip +Vin Scope Cout Cout -Out Resistive Load Copper Strip Scope Copper Strip Technical Notes Input Source Impedance The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module. In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor on the input to insure startup. By using a good quality low Equivalent Series Resistance (ESR < 1.0Ω at 100 kHz) capacitor of a 10μF for the 12V input devices and a 4.7μF for the 24V input devices and a 2.2μF for the 48V devices, capacitor mounted close to the power module helps ensure stability of the unit. + DC Power Source +Vin + +Out DC / DC Converter Load Cin - -Vin -Out Output Ripple Reduction A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is recommended to use 3.3μF capacitors at the output. + +Vin - +Out Single Output DC / DC Converter DC Power Source -Vin + Cout +Vin DC Power Source Load -Out - +Out Dual Output Com. DC / DC Converter -Vin -Out Cout Load Load Cout Maximum Capacitive Load The MIE06-HI series has limitation of maximum connected capacitance on the output. The power module may operate in current limiting mode during start-up, affecting the ramp-up and the startup time. Connect capacitors at the point of load for best performance. The maximum capacitance can be found in the data sheet. Thermal Considerations Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the maximum temperature rating of the components inside the power module, the case temperature must be kept below 95℃. The derating curves are determined from measurements obtained in a test setup. Position of air velocity probe and thermocouple 50mm / 2in 15mm / 0.6in Air Flow DUT Design & Feature Considerations Conducted and radiated emissions < A with external coupling capacitor Cio=1 nF < B 18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan Tel: 886-6-2923150 Fax: 886-6-2923149 E-mail: [email protected] Minmax Technology Co., Ltd. 2016/06/07 P5 Page 4 of 4