1S20 THRU 1S100

1S20
THRU
1S100
SCHOTTKY BARRIER RECTIFIER
VOLTAGE RANGE 20 to 100 Volts CURRENT 1.0 Ampere
FEATURES
*
*
*
*
*
*
*
Low power loss, high efficiency
Low leakage
Low forward voltage
High current capability
High speed switching
High surge capabitity
High reliability
R-1
MECHANICAL DATA
*
*
*
*
*
Case: Molded plastic
Epoxy: Device has UL flammability classification 94V-O
Lead: MIL-STD-202E method 208C guaranteed
Mounting position: Any
Weight: 0.12 gram
.025 (0.64)
DIA.
.021 (0.53)
.787 (20.0)
MIN.
.126 (3.2)
.106 (2.7)
.102 (2.6)
DIA.
.091 (2.3)
.787 (20.0)
MIN.
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25 o C ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
Dimensions in inches and (millimeters)
MAXIMUM RATINGS (@ TA=25 OC unless otherwise noted)
SYMBOL
1S20
1S30
1S40
1S50
1S60
1S80
1S100
UNITS
Maximum Recurrent Peak Reverse Voltage
VRRM
20
30
40
50
60
80
100
Volts
Maximum RMS Voltage
VRMS
14
21
28
35
42
56
70
Volts
VDC
20
30
40
50
60
80
100
Volts
RATINGS
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
.375” (9.5mm) lead length
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Typical Thermal Resistance (Note 3)
IO
1.0
Amps
I FSM
20
Amps
RqJA
60
RqJL
20
0
C/W
Typical Junction Capacitance (Note 1)
CJ
110
Operating Temperature Range
TJ
150
0
C
T STG
-55 to + 150
0
C
Storage Temperature Range
pF
ELECTRICAL CHARACTERISTICS (@TA=25 C unless otherwise noted)
O
CHARACTERISTICS
SYMBOL
Maximum Instantaneous Forward Voltage at 1.0A DC
Maximum Average Reverse Current
@T A = 25 o C
at Rated DC Blocking Voltage
@T A = 100o C
NOTES : 1. Measured at 1 MHz and applied reverse voltage of 4.0 volts.
2. “Fully ROHS compliant”, “100% Sn plating (Pb-free)”.
3. Thermal Resistance : At 9.5mm lead lengths, PCB mounted.
VF
IR
1S20
1S30
1S40
1S50
.55
1S60
.70
1S80
1S100
.85
UNITS
Volts
0.2
mAmps
10
mAmps
2006-11
1S5
0.8
~1
0
Single
Half Wave 60HZ
Resistive or
Inductive Load
0.375" (9.5mm) Lead Length
0.4
0.2
0
S4
0.6
S10
20
0~1
1S
AVERAGE FORWARD CURRENT, (A)
1.0
0
25
50
75
100
125
150
175
INSTANTANEOUS FORWARD CURRENT, (A)
RATING AND CHARACTERISTICS CURVES ( 1S20 THRU 1S100 )
20
T J = 25 OC
10 Pulse Width = 300mS
1% Duty Cycle
1S20
1S30
1S40
1S50
1S60
1S80
1S100
1.0
0.1
0.1
O
FIG.1 TYPICAL FORWARD CURRENT
DERATING CURVE
100
1S20~1S40
10
TA = 125 OC
1.0
TA = 75 OC
TA = 25 OC
0.1
0.01
0.001
0
20
40
60
80
100
120
140
0.7
0.9
1.1
1.3 1.5
1.7
1.9
2.1
FIG.2 TYPICAL INSTANTANEOUS
FORWARD CHARACTERISTICS
100
1S50~1S100
10
TA = 125 OC
1.0
TA = 75 OC
0.1
0.01
0.001
TA = 25 OC
0
20
40
60
80
100
120
140
PERCENT RATED PEAK REVERSE VOLTAGE, (%)
PERCENT RATED PEAK REVERSE VOLTAGE, (%)
FIG.3 TYPICAL REVERSE CHARACTERISTICS
PEAK FORWARD SURGE CURRENT, (A)
CT, TOTAL CAPACITANCE, (pF)
0.5
FIG.3 TYPICAL REVERSE CHARACTERISTICS
400
TJ = 25 OC
200
100
80
60
40
20
10
0.3
INSTANTANEOUS FORWARD VOLTAGE, (V)
INSTANTANEOUS REVERSE CURRENT, (mA)
INSTANTANEOUS REVERSE CURRENT, (mA)
AMBIENT TEMPERATURE, ( C)
0.1
0.4
1.0
4
10
40
REVERSE VOLTAGE, (V)
FIG.4 TYPICAL JUNCTION CAPACITANCE
80
25
8.3mS Single Half Sine-Wave
JEDEC Method
20
15
10
5
0
1
2
4
6
8
10
20
40
80 100
NUMBER OF CYCLES AT 60Hz
FIG.5 MAXIMUM NON-REPETITIVE FORWARD SURGE CURRENT
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.