10A05 THRU 10A10 SILICON RECTIFIER VOLTAGE RANGE 50 to 1000 Volts CURRENT 10 Amperes FEATURES * * * * * High surge current capability Low leakage Low forward voltage drop High current capability Low lost R-6 MECHANICAL DATA * * * * * Case: Molded plastic black body Epoxy: Device has UL flammability classification 94V-O Lead: MIL-STD-202E method 208C guaranteed Mounting position: Any Weight: 2.08 gram .052 (1.3) 0.96 (24.5) MIN. .048 (1.2) DIA. .360 (9.1) .340 (8.6) .360 (9.1) .340 (8.6) MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS DIA. 0.96 (24.5) MIN. Ratings at 25 o C ambient temperature unless otherwise specified. Single phase, half wave, 60 Hz, resistive or inductive load. For capacitive load, derate current by 20%. Dimensions in inches and (millimeters) MAXIMUM RATINGS (@ TA=25 OC unless otherwise noted) RATINGS Maximum Recurrent Peak Reverse Voltage Maximum RMS Voltage Maximum DC Blocking Voltage Maximum Average Forward Rectified Current at T A = 50 o C SYMBOL 10A05 10A1 10A2 10A4 10A6 10A8 10A10 UNITS VRRM 50 100 200 400 600 800 1000 Volts VRMS 35 70 140 280 420 560 700 Volts VDC 50 100 200 400 600 800 1000 Volts 10 Amps Peak Forward Surge Current IFM(surge): 8.3 ms single half sine-wave superimposed on rated load (JEDEC method) I FSM 400 Amps Typical Thermal Resistance (Note 3) RqJA 9 0 Typical Junction Capacitance (Note 1) Operating and Storage Temperature Range IO CJ 135 T J, T STG -55 to + 150 C/W pF 0 C ELECTRICAL CHARACTERISTICS (@TA=25 C unless otherwise noted) O SYMBOL CHARACTERISTICS Maximum Forward Voltage at 10A DC Maximum DC Average Reverse Current at Rated DC Blocking Voltage @T A = 25 o C @T A = 100 o C Maximum Full Load Reverse Current Average Full Cycle .375" (9.5mm) Lead Length at T L =75 OC NOTES : 1. Measured at 1.0 MHz and applied average voltage of 4.0VDC 2. “Fully ROHS compliant”, “100% Sn plating (Pb-free)”. 3. Thernal Resistance: At 9.5mm lead lengths,PCB mounted. VF IR 10A05 10A1 10A2 10A4 10A6 10A8 10A10 UNITS 1.1 Volts 10 100 uAmps 50 2009-06 REV: A RATING AND CHARACTERISTICS CURVES ( 10A05 THRU 10A10 ) PEAK FORWARD SURGE CURRENT, (A) AVERAGE FORWARD CURRENT, (A) 10 8 6 4 Single Phase Half Wave 60Hz Resistive or Inductive Load 2 0 0 25 50 75 100 125 150 175 500 8.3ms Single Half Sine-Wave (JEDED Method) 400 300 200 100 0 0 2 O 10 TJ = 25 OC 1.0 Pulse Width = 300ms 1% Duty Cycle 0.1 0 0.5 1.0 1.5 2.0 2.5 3.0 INSTANTANEOUS REVERSE CURRENT, (uA) 100 4 6 8 10 20 1000 FIG.2 MAXIMUM NON-REPETITIVE FORWARD SURGE CURRENT 100 TJ = 100 OC 40 10 TJ = 25 OC 4 1 0 20 40 60 80 FIG.4 TYPICAL REVERSE CHARACTERISTICS 25 20 15 10 5 0.1 100 120 PERCENT OF RATED PEAK REVERSE VOLTAGE, (%) FIG.3 TYPICAL INSTANTANEOUS FORWARD CHARACTERISTICS 0 60 80 100 400 INSTANTANEOUS FORWARD VOLTAGE, (V) 0 40 NUMBER OF CYCLES AT 60Hz FIG.1 TYPICAL FORWARD CURRENT DERATING CURVE THERMAL RESISTANCE, (OC/W) INSTANTANEOUS FORWARD CURRENT, (A) AMBIENT TEMPERATURE, ( C) 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 EQUAL LEAD LENGTH TO HEAT SINK, (IN.) FIG.5 TYPICAL THERMAL RESISTANCE vs. LEAD LENGTH 140 DISCLAIMER NOTICE Rectron Inc reserves the right to make changes without notice to any product specification herein, to make corrections, modifications, enhancements or other changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or use of any product or circuit. Rectron products are not designed, intended or authorized for use in medical, life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.