VOLTAGE RANGE 50 to 1000 Volts CURRENT 10 Amperes
FEATURES
*
*
*
*
*
High surge current capability
Low leakage
Low forward voltage drop
High current capability
Low lost
R-6
MECHANICAL DATA
*
*
*
*
*
Case: Molded plastic black body
Epoxy: Device has UL flammability classification 94V-O
Lead: MIL-STD-202E method 208C guaranteed
Mounting position: Any
Weight: 2.08 gram
.052 (1.3)
0.96 (24.5)
MIN.
.048 (1.2)
DIA.
.360 (9.1)
.340 (8.6)
.360 (9.1)
.340 (8.6)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
DIA.
0.96 (24.5)
MIN.
Ratings at 25 o C ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
Dimensions in inches and (millimeters)
MAXIMUM RATINGS (@ TA=25 OC unless otherwise noted)
RATINGS
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current at T A = 50 o C
SYMBOL
10A05
10A1
10A2
10A4
10A6
10A8
10A10
UNITS
VRRM
50
100
200
400
600
800
1000
Volts
VRMS
35
70
140
280
420
560
700
Volts
VDC
50
100
200
400
600
800
1000
Volts
10
Amps
Peak Forward Surge Current IFM(surge): 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
I FSM
400
Amps
Typical Thermal Resistance (Note 3)
RqJA
9
0
Typical Junction Capacitance (Note 1)
Operating and Storage Temperature Range
IO
CJ
135
T J, T STG
-55 to + 150
C/W
pF
0
C
ELECTRICAL CHARACTERISTICS (@TA=25 C unless otherwise noted)
O
SYMBOL
CHARACTERISTICS
Maximum Forward Voltage at 10A DC
Maximum DC Average Reverse Current at
Rated DC Blocking Voltage
@T A = 25 o C
@T A = 100 o C
Maximum Full Load Reverse Current Average Full Cycle
.375" (9.5mm) Lead Length at T L =75 OC
NOTES : 1. Measured at 1.0 MHz and applied average voltage of 4.0VDC
2. “Fully ROHS compliant”, “100% Sn plating (Pb-free)”.
3. Thernal Resistance: At 9.5mm lead lengths,PCB mounted.
VF
IR
10A05
10A1
10A2
10A4
10A6
10A8
10A10
UNITS
1.1
Volts
10
100
uAmps
50
2009-06
REV: A
RATING AND CHARACTERISTICS CURVES ( 10A05 THRU 10A10 )
PEAK FORWARD SURGE CURRENT, (A)
AVERAGE FORWARD CURRENT, (A)
10
8
6
4
Single Phase
Half Wave 60Hz
Resistive or
Inductive Load
2
0
0
25
50
75
100
125
150
175
500
8.3ms Single Half Sine-Wave
(JEDED Method)
400
300
200
100
0
0
2
O
10
TJ = 25 OC
1.0
Pulse Width = 300ms
1% Duty Cycle
0.1
0
0.5
1.0
1.5
2.0
2.5
3.0
INSTANTANEOUS REVERSE CURRENT, (uA)
100
4
6
8 10
20
1000
FIG.2 MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
100 TJ = 100 OC
40
10
TJ = 25 OC
4
1
0
20
40
60
80
FIG.4 TYPICAL REVERSE
CHARACTERISTICS
25
20
15
10
5
0.1
100
120
PERCENT OF RATED PEAK REVERSE VOLTAGE, (%)
FIG.3 TYPICAL INSTANTANEOUS
FORWARD CHARACTERISTICS
0
60 80 100
400
INSTANTANEOUS FORWARD VOLTAGE, (V)
0
40
NUMBER OF CYCLES AT 60Hz
FIG.1 TYPICAL FORWARD CURRENT
DERATING CURVE
THERMAL RESISTANCE, (OC/W)
INSTANTANEOUS FORWARD CURRENT, (A)
AMBIENT TEMPERATURE, ( C)
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9 1.0
EQUAL LEAD LENGTH TO HEAT SINK, (IN.)
FIG.5 TYPICAL THERMAL RESISTANCE vs. LEAD LENGTH
140
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.