RS2501M THRU RS2507M SINGLE-PHASE GLASS PASSIVATED SILICON BRIDGE RECTIFIER VOLTAGE RANGE 50 to 1000 Volts CURRENT 25 Amperes FEATURES * * * * * * Low leakage Low forward voltage Mounting position: Any Surge overload rating: 300 amperes peak Ideal for printed cikcuit boakds High forward surge current capability RS-25M MECHANICAL DATA .189 ( 4.8 ) .173 ( 4.4 ) .087 (2.2 ) .071 (1.8 ) .800 (20.3 ) .775 (19.7 ) .441 (11.2 ) .425 (10.8 ) .197 ( 5 ) .165 (4.2 ) .150 (3.8 ) .106 (2.7 ) .096 (2.3 ) f.138 ( 3.5 ) .126 ( 3.2 ) .150 ( 3.8 ) .134 ( 3.4 ) 1.193 ( 30.3 ) 1.169 ( 29.7 ) .114 (2.9 ) .098 (2.5 ) .708 (18.0 ) .669 (17.0 ) * Epoxy: Device has UL flammability classification 94V-O * UL list the recognized component directory, file #E94233 MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS .043 (1.1 ) .035 (0.9 ) Ratings at 25 o C ambient temperature unless otherwise specified. Single phase, half wave, 60 Hz, resistive or inductive load. .031 (0.8 ) .023 (0.6 ) .402 (10.2 ) .303 (7.7 ) .303 (7.7 ) .386 (9.8 ) .287 (7.3 ) .287 (7.3 ) Dimensions in inches and (millimeters) MAXIMUM RATINGS (@ TA=25 OC unless otherwise noted) SYMBOL RS2501M RS2502M RS2503M RS2504M RS2505M RS2506M Maximum Recurrent Peak Reverse Voltage VRRM 50 100 200 400 600 800 1000 Volts Maximum RMS Voltage VRMS 35 70 140 280 420 560 700 Volts VDC 50 100 200 400 600 800 1000 RATINGS Maximum DC Blocking Voltage Maximum Average Forward Rectified Current at T C=55 OC with heatsink without heatsink Peak Forward Surge Current 8.3 ms single half sine-wave superimposed on rated load (JEDEC method) Typical Current Squared Time RS2507M UNITS Volts IO 25 4.3 Amps I FSM 300 Amps I 2t 373.3 Typical Thermal Resistance (Note 1) RqJC 1.0 0 C/W Typical Thermal Resistance (Note 1) RqJA 22 0 C/W TJ 150 0 C T STG -55 to + 150 0 C Operating Temperature Range Storage Temperature Range A 2S ELECTRICAL CHARACTERISTICS (@TA=25 C unless otherwise noted) O CHARACTERISTICS Maximum Forward Voltage at 12.5A DC SYMBOL RS2501M RS2502M RS2503M RS2504M RS2505M RS2506M RS2507M UNITS VF 1.1 Volts IR 5.0 200 uAmps uAmps o Maximum DC Average Reverse Current at @T A = 25 C Rated DC Blocking Voltage @T A = 125 o C NOTES : 1. Thermal resistance : Heat-sink case mounted. 2 . “Fully ROHS compliant”, “100% Sn plating (Pb-free)”. 2010-01 REV:A 30 20 60 10 50 POWER DISSIPATION, (W) INSTANTANEOUS FORWARD CURRENT, (A) RATING AND CHARACTERISTICS CURVES ( RS2501M THRU RS2507M ) TC= 150 OC (TYP) 5 TC= 25 OC (TYP) 2 1 0.5 0.2 0 Pulse test per one diode 0.2 0.4 0.6 0.8 1 1.2 1.4 40 30 20 10 0 1.6 sine wave TJ = 150 OC 0 INSTANTANEOUS FORWARD VOLTAGE, (V) 0 8.3ms 8.3ms 200 1 cycle non-repetitive Tj=25 100 0 0 1 2 5 10 20 50 P.C.B 2 soldering land 5mmf sine wave R-load free in air 0 40 70 90 110 CASE TEMPERATURE, (OC) 120 160 FIG.4 TYPICAL FORWARD CURRENT DERATING CURVE THERMAL RESISTANCE (OC/W) AVERAGE FORWARD CURRENT, (A) 5 50 80 1 sine wave R-load on heatsink 30 24 AMBIENT TEMPERATURE, (OC) 20 0 10 20 on glass-epoxi substrate 3 1 100 heatsink Tc Tc 10 16 4 FIG.3 SURGE FORWARD CURRENT CAPABILITY 15 12 5 NUMBER OF CYCLE 25 8 FIG.2 POWER DISSIPATION AVERAGE FORWARD CURRENT, (A) sine wave IFSM PEAK FORWARD SURGE CURRENT, (A) FIG.1 TYPICAL INSTANTANEOUS FORWARD CHARACTERITICS 300 4 AVERAGE RECTIFIED FORWARD CURRENT, (A) 130 150 FIG.5 TYPICAL FORWARD CURRENT DERATING CURVE 170 with thermal compound 0.9 0.8 0.7 0.6 0.5 0.4 2 3 4 5 6 7 MOUNTING TORQUE (kg.cm) FIG.6 CONTACT THERMAL RESISTANCE fcf 8 Marking Description Rectron Logo UL Logo RS250XM V Y WW Year – code: (Y:Last digit of year) Week – code: (WW:01~52) Part No. Voltage-code 1-------50V 2-------100V 3-------200V 4-------400V 5-------600V 6-------800V 7-------1000V PACKAGING OF DIODE AND BRIDGE RECTIFIERS BULK PACK EA PER BOX INNER BOX SIZE CARTON SIZE PACKING CODE RS-25M -B 300 230*190*46 410*243*157 1,800 13.37 PACKAGE PACKING CODE EA PER BOX INNER BOX SIZE CARTON SIZE EA PER CARTON WEIGHT(Kg) RS-25M -C 600 490*135*110 510*293*131 1,200 13.12 (mm) (mm) EA PER CARTON GROSS WEIGHT(Kg) PACKAGE TUBE PACK (mm) (mm) DISCLAIMER NOTICE Rectron Inc reserves the right to make changes without notice to any product specification herein, to make corrections, modifications, enhancements or other changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or use of any product or circuit. Rectron products are not designed, intended or authorized for use in medical, life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.