RECTRON RS1001M_10

RS1001M
THRU
RS1007M
SINGLE-PHASE GLASS PASSIVATED
SILICON BRIDGE RECTIFIER
VOLTAGE RANGE 50 to 1000 Volts CURRENT 10 Amperes
FEATURES
Low leakage
Low forward voltage
Mounting position : Any
Surge overload rating: 200 Amperes peak
Ideal for printed circuit boards
MSL: Level 2
.057 (1.45)
.041 (1.05)
.083 (2.1)
.069 (1.7)
.122 (3 .1 )
.114 (2.9)
.074 (1.9)
.059 (1.5)
.043 (1.1)
.035 (0.9)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
f.134 ( 3.4 )
.157 ( 4 )
* UL listed the recognized component directory, file #E94233
* Epoxy: Device has UL flammability classification 94V-O
.189 (4.8)
.173 (4.4)
.150 (3.8)
.134 (3.4)
.366 (9 .3 )
MECHANICAL DATA
.602 (15.3 )
.578 (14.7)
.995 (25.3)
.983 (24.7)
.382 (9 .7 )
RS-10M
.098 (2.5)
.146 ( 3.7 )
.130 ( 3.3 )
.708 ( 18.0 )
.669 ( 17.0 )
*
*
*
*
*
*
.031 (0.8)
.023 (0.6)
Ratings at 25 OC ambient temperature unless otherwise specified.
resistive or inductive load.
.303 (7.7)
.287 (7.3)
.303 (7.7)
.287 (7.3)
.303 (7.7)
.287 (7.3)
Dimensions in inches and (millimeters)
MAXIMUM CHARACTERISTICS ( @ TA = 25oC unless otherwise noted )
CHARACTERISTICS
SYMBOL
RS1001M RS1002M RS1003M RS1004M RS1005M RS1006M RS1007M UNITS
Maximum Recurrent Peak Reverse Voltage
VRRM
50
100
200
400
600
800
1000
Volts
Maximum RMS Bridge Input Voltage
VRMS
35
70
140
280
420
560
700
Volts
Maximum DC Blocking Voltage
VDC
50
100
200
400
600
800
1000
Volts
Maximum Average Forward Rectified Output Current
at Tc=100 degree with heatsink
IO
10
Amps
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load
IFSM
200
Amps
Typical Current Square Time
I 2T
165.9
A 2S
Typical Thermal Resistance from junction to ambient
RΘJA
22
RΘJC
1.0
TJ,TSTG
-55 to + 150
Typical Thermal Resistance from junction to case
Operating and Storage Temperature Range
C/W
O
C
O
o
ELECTRICAL CHARACTERISTICS ( @ TA = 25 C unless otherwise noted )
CHARACTERISTICS
SYMBOL
Maximum Forward Voltage Drop per element at 5.0A DC
Maximum Reverse Current at Rated
DC Blocking Voltage per element
@TA=25 OC
@TC=100 OC
Note: 1."Fully ROHS compliant", "100% Sn plating (Pb-free)".
2. Available in Halogen-free epoxy by adding suffix -HF after the part nbr.
VF
IR
RS1001M RS1002M RS1003M RS1004M RS1005M RS1006M RS1007M UNITS
1.1
Volts
5.0
µAmps
0.2
mAmps
2010-11
REV: A
30
20
60
10
50
POWER DISSIPATIONFP(W)
INSTANTANEOUS FORWARD CURRENT, (A)
RATING AND CHARACTERISTICS CURVES ( RS1001M THRU RS1007M )
5
TC = 150 C
o
2
(TYP)
T C = 25 C (TYP)
o
1
0.5
0.2
0.1
0.2
pulse test
per one diode
0.4
0.6
0.8
1
1.2
1.4
sine wave
o
Tj=150 C
40
30
20
10
0
1.6
0
FIG.1 TYPICAL INSTANTANEOUS FORWARD
CHARACTERISTICS
sine wave
0
8.3ms 8.3ms
1 cycle
non-repetitive
o
Tj=25 C
200
100
0
1
2
5
10
20
50
3
P.C.B
soldering land 5mmf
sine wave
R-load
free in air
2
1
0
100
0
40
THERMAL RESISTANCE (oC/W)
AVERAGE FORWARD CURRENT, (A)
6
sine wave
R-load
on heatsink
4
2
120
130
80
120
160
FIG.4 TYPICAL FORWARD CURRENT
DERATING CURVE
1.6
Tc
8
110
24
AMBIENT TEMPERATURE( C)
heatsink
Tc
100
20
O
10
90
16
on glass-epoxi substrate
FIG.3 SURGE FORWARD CURRENT CAPABILITY
80
12
4
NUMBER OF CYCLE
0
8
FIG.2 POWER DISSPATION
AVERAGE FORWARD CURRENT, (A)
300
4
AVERAGE RECTIFIED FORWARD CURRENT, Io (A)
IFSM
PEAK FORWARD SURGE CURRENT, (A)
INSTANTANEOUS FORWARD VOLTAGE, (V)
140
150
CASE TEMPERATURE( C)
o
FIG.5 TYPICAL FORWARD CURRENT
DERATING CURVE
160
with thermal compound
1.5
1.4
1.3
1.2
1.1
1
2
3
4
5
6
7
8
MOUNTING RORQUE (Kg.cm)
FIG.6 CONTACT THERMAL RESISTANCE
Marking Description
Rectron Logo
RS100XM
Plant - code
UL Logo
Year – code
(Y: Last digit of year &
A:2010, B:2011…..)
Part No.
Voltage-code
V Y WW
Week – code
(WW: 01~52)
1-------50V 2-------100V
3-------200V 4-------400V
5-------600V 6-------800V
7-------1000V
PACKAGING OF DIODE AND BRIDGE RECTIFIERS
BULK PACK
EA PER BOX
INNER BOX SIZE
CARTON SIZE
PACKING CODE
RS-4M/-10M
-B
600
236*236*40
497*251*100
2,400
11.09
PACKAGE
PACKING CODE
EA PER BOX
INNER BOX SIZE
CARTON SIZE
EA PER CARTON
WEIGHT(Kg)
RS-4M/-10M
-C
900
540*118*118
560*259*144
1,800
12.82
(mm)
(mm)
EA PER CARTON
GROSS
WEIGHT(Kg)
PACKAGE
TUBE PACK
(mm)
(mm)
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.