RBU601M THRU RBU607M SINGLE-PHASE GLASS PASSIVATED SILICON BRIDGE RECTIFIER VOLTAGE RANGE 50 to 1000 Volts CURRENT 6.0 Amperes FEATURES * * * * * Low leakage Low forward voltage Silver-plated copper leads Surge overload rating: 150 amperes peak Mounting position: Any RBU MECHANICAL DATA * UL listed the recognizde component dinrectory file # E252754 * Epoxy: Device has UL flammability classification 94V-O Please See Page 3 for Dimension MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS Ratings at 25 o C ambient temperature unless otherwise specified. resistive or inductive load. MAXIMUM RATINGS (@ TA=25 OC unless otherwise noted) RATINGS SYMBOL RBU601M RBU602M RBU603M RBU604M RBU605M RBU606M RBU607M UNITS Maximum Recurrent Peak Reverse Voltage VRRM 50 100 200 400 600 800 1000 Volts Maximum RMS Voltage VRMS 35 70 140 280 420 560 700 Volts VDC 50 100 200 400 600 800 1000 Volts Maximum DC Blocking Voltage Maximum Average Forward Rectified Current at T C = *100 o C (Note 4) Peak Forward Surge Current 8.3 ms single half sine-wave superimposed on rated load (JEDEC method) Typical Current Squared Time Typical Thermal Resistance (Note 1) Operating and Storage Temperature Range IO 6.0 Amps I FSM 150 Amps A 2 /S I 2t 93.3 R q JC 3.5 R q JA 26 T J, T STG -55 to + 150 0 C/ W 0 C ELECTRICAL CHARACTERISTICS (@TA=25 C unless otherwise noted) O CHARACTERISTICS Maximum Instantaneous Forward Voltage at 6.0A DC Maximum DC Reverse Current at Rated DC Blocking Voltage @T A = 25 o C @T A = 125 o C SYMBOL RBU601M RBU602M RBU603M RBU604M RBU605M RBU606M RBU607M UNITS VF 1.1 Volts IR NOTES : 1. Thermal Resistance : Heat-sink case mounted or if PCB mounted. 2. "Fully ROHS compliant", "100% Sn plating (Pb-free)". 3. Equivalent to Vishay's GBU6 Series. 4. "*" Heat Sink Temperature. 5. Available in Halogen-free epoxy by adding suffix -HF after the part nbr. 2.0 300 uAmps 2010-05 REV:C 8.0 6.0 4.0 2.0 0 0 50 100 150 INSTANTANEOUS FORWARD CURRENT, (A) AVERAGE FORWARD OUTPUT CURRENT, (A) RATING AND CHARACTERISTICS CURVES ( RBU601M THRU RBU607M ) 40 10 4.0 1.0 0.4 0.1 0 O FIG.1 TYPICAL FORWARD CURRENT DERATING CURVE 1000 TA = 125 OC 100 10 TA = 25 OC 1.0 0.1 0 20 40 60 80 100 0.5 1.0 1.5 2.0 2.5 3.0 3.5 INSTANTANEOUS FORWARD VOLTAGE, (V) PEAK FORWARD SURGE CURRENT, (A) INSTANTANEOUS REVERSE CURRENT, (uA) HEAT SINK TEMPERATURE, ( C) T A = 25 OC Pulse Width = 300mS 1% Duty Cycle 120 140 PERCENT RATED PEAK REVERSE VOLTAGE, (%) FIG.3 TYPICAL REVERSE CHARACTERISTICS 240 FIG.2 TYPICAL INSTANTANEOUS FORWARD CHARACTERISTICS 8.3mS Single Half Sine-Wave JEDEC Method 200 160 120 80 40 0 1 2 5 10 20 50 100 NUMBER OF CYCLES AT 60Hz FIG.4 MAXIMUM NON-REPETITIVE FORWARD SURGE CURRENT .140 (3.56) .130 (3.30) .160 (4.1) .140 (3.5) .075 (1.9)R .512 (13.0) .740 (18.8) .720 (18.3) .366 (9.3) .343 (8.7) .085 (2.16) .065 (1.65) .880 (22.3) .860 (21.8) .080 (2.03) .060 (1.52) .310(7.9) .290(7.4) Dimensions in inches and (millimeters) .085 (2.16) .075 (1.90) .210 (5.33) .190 (4.83) .080 (2.03) .065 (1.65) .050 (1.27) .040 (1.02) .710 (18.0) .690 (17.5) .100 (2.54) .085 (2.16) .022 (0.56) .018 (0.46) Marking Description Rectron Logo UL Logo RBU60XM VYWW Year – code (Y:Last digit of year &A:2010,B:2011……) Week – code: (WW:01~52) Part No. Voltage-code 1-------50V 2-------100V 3-------200V 4-------400V 5-------600V 6-------800V 7-------1000V PACKAGING OF DIODE AND BRIDGE RECTIFIERS BULK PACK EA PER BOX INNER BOX SIZE CARTON SIZE PACKING CODE RBU -B 450 240*239*35 502*251*126 2,700 13.00 PACKAGE PACKING CODE EA PER BOX INNER BOX SIZE CARTON SIZE EA PER CARTON WEIGHT(Kg) RBU -C 1,000 490*135*110 510*293*131 2,000 13.62 (mm) (mm) EA PER CARTON GROSS WEIGHT(Kg) PACKAGE TUBE PACK (mm) (mm) DISCLAIMER NOTICE Rectron Inc reserves the right to make changes without notice to any product specification herein, to make corrections, modifications, enhancements or other changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or use of any product or circuit. Rectron products are not designed, intended or authorized for use in medical, life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.