USB Smart Power Sensor 50Ω PWR-4GHS -30 dBm to +20 dBm, 9 kHz to 4000 MHz The Big Deal • Low cost • USB HID device compatible with 32/64 Bit operating systems • Includes “Measurement Application” GUI (Graphical User Interface) software with an API-DLL com object • High speed measurement capability Installation CD CASE STYLE: JL1504 Product Overview The Mini-Circuits PWR-4GHS Smart Power Sensor is a pocket-sized, 4.89” x 1.74” x 0.95”, precision test USB HID device (no driver installation required) that turns a Windows ® or Linux ® PC into a power meter. All specifications provided in the data sheet apply to continuous wave (CW) signals. Each unit is shipped with our N-to-SMA adapter and a quick-locking USB cable for reliable connectivity. Native software and detailed user guides are provided on the included CD, or can be downloaded from minicircuits.com anywhere an internet connection is available, providing a full range of data analysis options. Key Features Feature Advantages USB HID (Human Interface Device) Plug-and-Play (no need to install driver for the device). GUI Measurement Application Software built-in Enables the user to perform measurements on RF components such as Couplers, Filters, Amplifiers etc. and displays numerical data and graphs. 32/64 Bit operating systems Compatible with Windows ® and Linux ®1 operating systems. No calibration required before taking measurement The PWR-4GHS does not require any reference signal for calibration. 1 NotesWindows is a registered trademark of Microsoft Corporation in the United States and other countries. Linux is a registered trademark of Linus Torvalds. Neither A. Performance and nor quality and conditions not expressly stated in thissensors specification intended to be excluded andowners do not form a part of thisreferenced specification document. Mini-Circuits theattributes Mini-Circuits PWR-series smart power are document affiliatedare with or endorsed by the of the above trademarks B. Electrical specifications and performance data contained in this specification document are based on Mini-Circuit’s applicable established test performance criteria and measurement instructions. C. The parts coveredand by this document to Mini-Circuits standard limited warranty and terms and conditions (collectively, “Standard Terms”); Purchasers of this part are entitled Mini-Circuits thespecification Mini-Circuits logo are aresubject registered trademarks of Scientific Components Corporation. to the rights and benefits contained therein. For a full statement of the Standard Terms and the exclusive rights and remedies thereunder, please visit Mini-Circuits’ website at www.minicircuits.com/MCLStore/terms.jsp Mini-Circuits ® www.minicircuits.com P.O. Box 35166, Brooklyn, NY 11235-0003 (718) 934-4500 [email protected] Page 1 of 5 USB Smart Power Sensor 50Ω PWR-4GHS 9 kHz to 4000 MHz Product Features • Wide bandwidth, 9 kHz to 4000 MHz • 50 dB Dynamic Range, -30 to +20 dBm • Good VSWR, 1.1:1 typ. • Fast measurement speed, 30 msec typ. • Automatic frequency calibration & temperature compensation • Multi-sensor capability (up to 24) • Built in Application Measurement Software • Remote operation via internet • Effective, easy-to-use Windows® GUI • Compatible with 32/64-bit Windows® or Linux® operating systems • Supports a wide range of programming environments (See application note AN-49-001 for details) • Installation CD Case Style: JL1504 Model No. Description Price USB smart Power Sensor $795.00 ea. PWR-4GHS Included Accessories PWR-SEN-4GHS Power Sensor Head USB-CBL+ 6 ft data cable (USB Type-A Plug) N-Type (F) to SMA(M) Adapter NF-SM50+ PWR-SEN-CD Installation CD Typical Applications • Turn almost any Windows or Linux PC into a Power Meter • Pocket-sized portability for benchtop testing anywhere • Remote location monitoring • Automatic, scheduled data collection • Evaluate high-power, multi-port devices with built-in virtual couplers/attenuators & other software tools Qty. (1-4) 1 1 1 RoHS Compliant See our web site for RoHS Compliance methodologies and qualifications Mini-Circuits Power Meter Program for Smart USB Power Sensor Notes A. Performance and quality attributes and conditions not expressly stated in this specification document are intended to be excluded and do not form a part of this specification document. B. Electrical specifications and performance data contained in this specification document are based on Mini-Circuit’s applicable established test performance criteria and measurement instructions. C. The parts covered by this specification document are subject to Mini-Circuits standard limited warranty and terms and conditions (collectively, “Standard Terms”); Purchasers of this part are entitled to the rights and benefits contained therein. For a full statement of the Standard Terms and the exclusive rights and remedies thereunder, please visit Mini-Circuits’ website at www.minicircuits.com/MCLStore/terms.jsp Mini-Circuits ® www.minicircuits.com P.O. Box 35166, Brooklyn, NY 11235-0003 (718) 934-4500 [email protected] Rev. B M146352 EDR-10382 PWR-4GHS RAV 140507 Page 2 of 5 PWR-4GHS USB Smart Power Sensor Electrical Specifications (CW) 2, -30 dBm to +20 dBm, 9kHz to 4000 MHz Freq. Range (MHz) Min. Typ. Max. Units Dynamic Range 3 0.009 - 4000 -30 - +20 dBm VSWR 0.009 - 4000 - 1.1 1.4 :1 0.009 - 1000 - ± 0.05 ± 0.35 dB Parameter @ -30 to +5 dBm Uncertainty of Power Measurement @ 25ºC @ +5 to +12 dBm @ +12 to +20 dBm @ -30 to +5 dBm Uncertainty of Power Measurement @ 0ºC to 50ºC @ +5 to +12 dBm @ +12 to +20 dBm 1000 - 4000 - ± 0.05 ± 0.30 dB 0.009 - 1000 - ± 0.05 ± 0.30 dB 1000 - 4000 - ± 0.05 ± 0.25 dB 0.009 - 1000 - ± 0.05 ± 0.30 dB 1000 - 4000 - ± 0.10 ± 0.35 dB 0.009 - 1000 - ± 0.10 - dB 1000 - 4000 - ± 0.10 - dB 0.009 - 1000 - ± 0.10 - dB 1000 - 4000 - ± 0.10 - dB 0.009 - 1000 - ± 0.10 - dB 1000 - 4000 - ± 0.10 - dB Linearity @ 25ºC 0.009 - 4000 - ± 1.5 - % Measurement Resolution 0.009 - 4000 0.01 - - dB 0.009 - 4000 1 - 999 - - 100 - - 30 - - 40 70 Averaging Range Measurement Speed @ Low Noise Mode @ Faster Mode Current (via host USB) 0.009 - 4000 0.009 - 4000 mSec mA Minimum System Requirements Parameter Requirements Interface USB HID Host operating system 32 Bit operating system: Windows 98 ®, Windows XP ®, Windows Vista ®, Windows 7®, Windows 8® 64 Bit operating system: Windows Vista ®, Windows 7 ®, Windows 8® Linux ® support: 32/64 Bit operating system Hardware Pentium ® II or higher, RAM 256 Mb, USB port USB cable (supplied) Power sensor to be used with the supplied USB cable only Absolute Maximum Ratings Parameter Ratings Operating Temperature Storage Temperature DC Voltage at RF port CW Power 0°C to 50°C -30°C to 70°C 4V +25dBm 2 3 All specifications apply to continuous wave (CW) signals. Maximum continuous safe operational power limit: +23 dBm. Performance is guaranteed up to +20 dBm. Permanent damage may occur if any of these limits are exceeded. Operating in the range between operating power limits and absolute maximum ratings for extended periods of time may result in reduced life and reliability. Notes A. Performance and quality attributes and conditions not expressly stated in this specification document are intended to be excluded and do not form a part of this specification document. B. Electrical specifications and performance data contained in this specification document are based on Mini-Circuit’s applicable established test performance criteria and measurement instructions. C. The parts covered by this specification document are subject to Mini-Circuits standard limited warranty and terms and conditions (collectively, “Standard Terms”); Purchasers of this part are entitled to the rights and benefits contained therein. For a full statement of the Standard Terms and the exclusive rights and remedies thereunder, please visit Mini-Circuits’ website at www.minicircuits.com/MCLStore/terms.jsp Mini-Circuits ® www.minicircuits.com P.O. Box 35166, Brooklyn, NY 11235-0003 (718) 934-4500 [email protected] Page 3 of 5 PWR-4GHS USB Smart Power Sensor Typical Performance Curves O VSWR VSWR 1.30 C UNCERTAINTY OF POWER MEASUREMENT @ @ 25 25°C 0.30 0°C +25°C +50°C UNCERTAINTY (dB) UNCERTAINTY (dB) VSWR (:1) VSWR (:1) 1.25 -30 dBm -10 dBm 0 dBm +12 dBm +15 dBm +20 dBm +5 dBm 0.15 1.20 0.00 1.15 1.10 -0.15 -0.15 1.05 -0.30 -0.30 1.00 0 500 1000 1500 2000 2500 3000 FREQUENCY (MHz) FREQUENCY (MHz) 3500 0 4000 2000 3000 FREQUENCY FREQUENCY (MHz) (MHz) 4000 LINEARITY 25OC LINEARITY @ 25°C 4.0 -30 to 0 dBm 3.0 Linearity (%) (%) LINEARITY 1000 0 to +20 dBm 2.0 1.0 0.0 -1.0 -2.0 -3.0 -4.0 0 1000 2000 FREQUENCY Frequency(MHz) (MHz) 3000 4000 Outline Drawing (JL1504) Note 4 Outline Dimensions ( inch mm ) A B C D E 4.89 1.74 .95 3.50 72.0 WT. GRAMS 4 Power sensor to be used with the supplied USB cable only. 250 Notes 124.2 and quality44.2 24.1 not expressly 88.9stated in this 1829 A. Performance attributes and conditions specification document are intended to be excluded and do not form a part of this specification document. B. Electrical specifications and performance data contained in this specification document are based on Mini-Circuit’s applicable established test performance criteria and measurement instructions. C. The parts covered by this specification document are subject to Mini-Circuits standard limited warranty and terms and conditions (collectively, “Standard Terms”); Purchasers of this part are entitled to the rights and benefits contained therein. For a full statement of the Standard Terms and the exclusive rights and remedies thereunder, please visit Mini-Circuits’ website at www.minicircuits.com/MCLStore/terms.jsp Mini-Circuits ® www.minicircuits.com P.O. Box 35166, Brooklyn, NY 11235-0003 (718) 934-4500 [email protected] Page 4 of 5 PWR-4GHS USB Smart Power Sensor Warranty For a full statement of the limited warranty offered by Mini-Circuits for the PWR-4GHS and the non-exclusive license for the software provided with the PWR-4GHS and the exclusive rights and remedies thereunder, together with MiniCircuit’s limitations of warranties and limitation of liability, please refer to Mini-Circuits User Guide for the PWR-4GHS and Mini-Circuits standard terms of sale found on its standard purchase order acknowledgment form, which are incorporated herein by reference. If you do not have these documents, please contact a Mini-Circuits representative and these documents will be provided promptly. Alternatively, for a copy of Mini-Circuits’ standard terms of sale, visit Mini-Circuits’ website at www.minicircuits.com/MCLStore/terms.jsp. THE SOFTWARE IS PROVIDED “AS IS”, “WITH ALL FAULTS”, AND WITHOUT ANY EXPRESS OR IMPLIED WARRANTY OF ANY KIND, ALL OF WHICH ARE HEREBY WAIVED. Ordering, Pricing & Availability Information see our web site 5 Model Description PWR-4GHS USB Smart Power Sensor Included Accessories Description PWR-SEN-4GHS Power Sensor Head USB-CBL+5 6 ft data cable with USB Type-A plug connector NF-SM50+ N-Type Female to SMA Male Adapter. PWR-SEN-CD Installation CD Power sensor to be used with the supplied USB cable only. Calibration Model Description CALSEN-4GHS Calibration Service Click Here Additional Notes A. Performance and quality attributes and conditions not expressly stated in this specification document are intended to be excluded and do not form a part of this specification document. B. Electrical specifications and performance data contained in this specification document are based on Mini-Circuit’s applicable established test performance criteria and measurement instructions. C. The parts covered by this specification document are subject to Mini-Circuits standard limited warranty and terms and conditions (collectively, “Standard Terms”); Purchasers of this part are entitled to the rights and benefits contained therein. For a full statement of the Standard Terms and the exclusive rights and remedies Notes thereunder, please visit Mini-Circuits’ at www.minicircuits.com/MCLStore/terms.jsp A. Performance and quality attributes and conditions website not expressly stated in this specification document are intended to be excluded and do not form a part of this specification document. B. Electrical specifications and performance data contained in this specification document are based on Mini-Circuit’s applicable established test performance criteria and measurement instructions. C. The parts covered by this specification document are subject to Mini-Circuits standard limited warranty and terms and conditions (collectively, “Standard Terms”); Purchasers of this part are entitled to the rights and benefits contained therein. For a full statement of the Standard Terms and the exclusive rights and remedies thereunder, please visit Mini-Circuits’ website at www.minicircuits.com/MCLStore/terms.jsp Mini-Circuits ® www.minicircuits.com P.O. Box 35166, Brooklyn, NY 11235-0003 (718) 934-4500 [email protected] Page 5 of 5