Rectifier Assemblies Catalog (~2.8 MB, desktop version)

High Reliability Hermetically
Sealed Rectifier Assemblies
Shortform Catalog 2015
Bridge Rectifier Assemblies and
High Voltage Rectifier Assemblies:
Solid State Devices, Inc.
14701 Firestone Blvd., La Mirada, CA 90638
Phone- 562-404-4474 Internet- www.ssdi-power.com
Jump to Table of Contents
Doublers- Centertap
l Single-Phase Bridges
l Three-Phase Bridges
l HV Bridge Series
l HV Assemblies
l 3-Phase Schottky Modules
l
Solid State Devices, Inc.
This book represents technical data for the line of Solid State Devices, Inc. High Reliability
Hermetically Sealed Rectifier Assemblies. Complete specifications for the individual devices
are provided in the form of data sheets from our web site: www.ssdi-power.com
The information in this book has been carefully checked and is believed to be accurate;
however, no responsibility is assumed for errors or omissions.
Solid State Devices, Inc. reserves the right to make changes without further notice to any
product herein. Solid State Devices, Inc. does not assume liability arising out of the
application or use of any product or circuit described herein; neither does it convey any
license under its patent rights nor the rights of others.
™
Solid State Devices, Inc. and
are registered trademarks of Solid State Devices, Inc.
Solid State Devices, Inc. is an Equal Opportunity/Affirmative Action Employer.
Warnings
Due to technical requirements, components may contain dangerous substances. For
information on the types in question, please contact SSDI.
SSDI components may only be used in life-support devices or systems with the express
written approval of SSDI. Failure of such components can reasonably be expected to cause
the failure of that life-support device or system, or to affect the safety or effectiveness of
that device or system. Life support devices or systems are intentionally implanted in the
human body, or to support and/or maintain and/or protect human life. If they fail, it is
reasonable to assume that the health of the user or other persons may be endangered.
Solid State Devices is AS9100C and ISO 9001 Certified
Entire contents copyright © 2015 Solid State Devices, Inc. All Rights Reserved.
No part of this catalog may be reproduced, transmitted, rewritten, scanned, stored mechanically or
electronically, translated into other languages, or adapted for any use without the express written
permission of Solid State Devices, Inc.
1
Jump to Table of Contents
Table of Contents
Doublers- Centertap*
9A to 120A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page
Single Phase Bridge Rectifiers*
300mA to 100A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page
Three Phase Bridge Rectifiers*
500mA to 100A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
High Voltage Bridges & Assemblies*
500mA to 20A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Three Phase Schottky Modules*
320A to 400A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
High Reliability Screening Flow
TX, TXV, and S-Level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Sales Representatives
7
Page 13
Page 19
Page 25
Page 26
Worldwide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Back
* High Reliability Screening Available, See Page 26.
3
Cover
2
Doublers- Centertap
IO
9 Amps to 120 Amps*
PIV
35 Volts to 1,000 Volts*
trr
40 nsec to 5 µsec*
* Higher voltages, higher currents & faster trr available,
please contact SSDI authorized representative or factory.
3
Data sheets available at www.ssdi-power.com
Jump to Table of Contents
Doublers- Centertap
High Reliability Screening Available, See Page 26
Doublers- Centertap - Ratings Based on 25 °C Case Temperature
Sorted by trr then by IF(AV)
Part Number
All Devices Screened to:
Maximum
Reverse
Recovery
Time
TX, TXV, or S-Level
(MIL-PRF-19500)
Average
DC Output
Current
Peak
Inverse
Voltage
(per leg)
trr
IF(AV)
PIV
nsec
Amps
Volts
Maximum
Forward Voltage
Maximum
Leakage
Drop (per leg)
VF @ IF
Volts
Amps
Non-Repetitive
Sinusoidal
Package
Data Sheet
Current
Surge
(@ PIV)
(8.3msec)
Types
Number
IR
Izsm
µA
Amps
SDA240A
Schottky
120
35
0.65
60
300
800
SDA240
RS0297
SDA240B
Schottky
120
45
0.65
60
300
800
SDA240
RS0297
SDAI03A_HF
30
30
150
1.1
9
10
175
SDAI03
RA0090
SDA40AHF
40
9
50
1.35
3
10
75
SDA280
RA0055
SDA40BHF
40
9
100
1.35
3
10
75
SDA280
RA0055
SDA40CHF
40
9
200
1.35
3
10
75
SDA280
RA0055
SDA40DHF
40
9
300
1.35
3
10
75
SDA280
RA0055
SDA40EHF
40
9
400
1.35
3
10
75
SDA280
RA0055
SDA40FHF
40
9
500
1.35
3
10
75
SDA280
RA0055
SDA40GHF
40
9
600
1.35
3
10
75
SDA280
RA0055
SDA480AD
40
20
50
0.95
6
20
150
SDA180
RA0037
SDA480AN
40
20
50
0.95
6
20
150
SDA180
RA0037
SDA480AP
40
20
50
0.95
6
20
150
SDA180
RA0037
SDA480BD
40
20
100
0.95
6
20
150
SDA180
RA0037
SDA480BN
40
20
100
0.95
6
20
150
SDA180
RA0037
SDA480BP
40
20
100
0.95
6
20
150
SDA180
RA0037
SDA480CD
40
20
150
0.95
6
20
150
SDA180
RA0037
SDA480CN
40
20
150
0.95
6
20
150
SDA180
RA0037
SDA480CP
40
20
150
0.95
6
20
150
SDA180
RA0037
SDA480DD
40
20
200
0.95
6
20
150
SDA180
RA0037
SDA480DN
40
20
200
0.95
6
20
150
SDA180
RA0037
SDA480DP
40
20
200
0.95
6
20
150
SDA180
RA0037
SDA480ED
40
20
250
0.95
6
20
150
SDA180
RA0037
SDA480EN
40
20
250
0.95
6
20
150
SDA180
RA0037
SDA480EP
40
20
250
0.95
6
20
150
SDA180
RA0037
SDA480FD
40
20
300
0.95
6
20
150
SDA180
RA0037
SDA480FN
40
20
300
0.95
6
20
150
SDA180
RA0037
SDA480FP
40
20
300
0.95
6
20
150
SDA180
RA0037
SDA382A
50
10
50
1.5
3
10
75
SDA380
RA0025
SDA382B
50
10
100
1.5
3
10
75
SDA380
RA0025
SDA382C
50
10
200
1.5
3
10
75
SDA380
RA0025
SDA382D
50
10
400
1.5
3
10
75
SDA380
RA0025
SDA382E
60
10
600
1.7
3
10
75
SDA380
RA0025
SDA382F
70
10
800
1.9
3
10
75
SDA380
RA0025
SDA382G
70
10
1000
1.9
3
10
75
SDA380
RA0025
SDA280A
150
15
50
1.4
5
5
150
SDA280
A00045
Data sheets available at www.ssdi-power.com
Jump to Table of Contents
4
Doublers- Centertap
High Reliability Screening Available, See Page 26
Sorted by trr then by IF(AV)
Part Number
All Devices Screened to:
TX, TXV, or S-Level
Doublers- Centertap - Ratings Based on 25 °C Case Temperature
Maximum
Reverse
Recovery
Time
Average
DC Output
Current
Peak
Inverse
Voltage
(per leg)
Maximum
Forward Voltage
Maximum
Leakage
Drop (per leg)
Non-Repetitive
Sinusoidal
Package
Data Sheet
Current
Surge
(@ PIV)
(8.3msec)
Types
Number
IR
Izsm
trr
IF(AV)
PIV
nsec
Amps
Volts
Volts
Amps
µA
Amps
SDA280B
150
15
100
1.4
5
5
150
SDA280
A00045
SDA280C
150
15
200
1.4
5
5
150
SDA280
A00045
SDA280D
150
15
400
1.4
5
5
150
SDA280
RA0050
SDAI03E_F
150
20
1000
2.2
9
1
150
SDAI03
RA0090
SDAI03B_F
150
30
400
1.5
9
1
150
SDAI03
RA0090
SDA280F
180
15
800
1.4
5
5
150
SDA280
RA0050
SDA280G
180
15
1000
1.4
5
5
150
SDA280
RA0050
SDAI03C
2000
30
600
1.2
9
1
150
SDAI03
RA0090
SDAI03E
2000
30
1000
1.2
9
1
150
SDAI03
RA0090
SDA380B
4000
10
100
1
5
5
150
SDA380
RA0023
SDA380A
5000
10
50
1.2
5
5
75
SDA380
RA0023
SDA381A
5000
10
50
1.35
3
5
75
SDA380
RA0024
SDA381B
5000
10
100
1.35
3
5
75
SDA380
RA0024
SDA380C
5000
10
200
1.2
5
5
75
SDA380
RA0023
SDA381C
5000
10
200
1.35
3
5
75
SDA380
RA0024
SDA380D
5000
10
400
1.2
5
5
75
SDA380
RA0023
SDA381D
5000
10
400
1.35
3
5
75
SDA380
RA0024
SDA380E
5000
10
600
1.2
5
5
75
SDA380
RA0023
SDA381E
5000
10
600
1.45
3
5
75
SDA380
RA0024
SDA380F
5000
10
800
1.2
5
5
75
SDA380
RA0023
SDA381F
5000
10
800
1.35
3
5
75
SDA380
RA0024
SDA380G
5000
10
1000
1.2
5
5
75
SDA380
RA0023
SDA381G
5000
10
1000
1.55
3
5
75
SDA380
RA0024
(MIL-PRF-19500)
VF @ IF
SDA180A
5000
15
50
1
5
1
150
SDA180
RA0033
SDA180B
5000
15
100
1
5
1
150
SDA180
RA0033
SDA180C
5000
15
200
1
5
1
150
SDA180
RA0033
SDA180D
5000
15
400
1
5
1
150
SDA180
RA0033
SDA180E
5000
15
600
1
5
1
150
SDA180
RA0033
SDA180F
5000
15
800
1
5
1
150
SDA180
RA0033
SDA180G
5000
15
1000
1
5
1
150
SDA180
RA0033
SDA188A
5000
50
50
1.05
25
1
500
Assembly
RA0035
SDA188B
5000
50
100
1.05
25
1
500
Assembly
RA0035
SDA188C
5000
50
200
1.05
25
1
500
Assembly
RA0035
SDA188D
5000
50
400
1.05
25
1
500
Assembly
RA0035
SDA188E
5000
50
600
1.05
25
1
500
Assembly
RA0035
SDA188F
5000
50
800
1.05
25
1
500
Assembly
RA0035
SDA188G
5000
50
1000
1.05
25
1
500
Assembly
RA0035
5
Data sheets available at www.ssdi-power.com
Jump to Table of Contents
Doublers- Centertap
SDA180 Outline:
1.880"
1.870"
.175"
2x Ø .165"
.354"
.334"
3x Ø .095"
.088"
1.490"
1.470"
1.00"
MAX
1
.500"
MAX
2
3
2.260"
2.240"
SDA180
.135"
.115"
SDA280 Outline:
1.880”
1.870”
.175”
2x Ø .165”
.354”
.334”
1.490”
1.470”
.660”
MAX
SDA280
.385”
.300”
1
3
2
.135”
.115”
2.260”
2.240”
SDA380 Outline:
.045" REF
.700"
MAX .305"
MAX
1.885"
1.865"
Ø.090" REF
1
2
3
.135"
.115"
2.260"
2.240"
2x Ø.180"
.165"
.354"
.334"
SDA380
1.490"
1.470"
High Reliability Screening Available, See Page 26
Jump to Table of Contents
Contact your local SSDI Representative or contact the factory directly
Phone- (562) 404-4474 Email- [email protected]
6
Single Phase Bridge Rectifiers
IO
0.3 Amps to 100 Amps*
PIV
50 Volts to 5,000 Volts*
trr
30 nsec to 5 µsec*
* Higher voltages, higher currents & faster trr available,
please contact SSDI authorized representative or factory.
7
Data sheets available at www.ssdi-power.com
Jump to Table of Contents
Single Phase Bridge Rectifiers
High Reliability Screening Available, See Page 26
Single Phase Bridges - Ratings Based on 25 °C Case Temperature
Sorted by trr then by IF(AV)
Part Number
All Devices Screened to:
Maximum
Reverse
Recovery
Time
TX, TXV, or S-Level
Average
DC Output
Current
Peak
Inverse
Voltage
Maximum
Forward Voltage
Drop (per leg)
(per leg)
Maximum
Leakage
Non-Repetitive
Sinusoidal
Package
Data Sheet
Current
Surge
(@ PIV)
(8.3msec)
Types
Number
IR
Izsm
trr
IF(AV)
PIV
nsec
Amps
Volts
Volts
Amps
µA
Amps
SDA356BHF
30
1
100
1
1
5
25
SDA276
RA0056
SDA356DHF
30
1
200
1
1
5
25
SDA276
RA0056
SDA165DHF
35
5
200
1.05
3
10
50
SDA165
RA0008
SDA165EHF
35
6
300
1.05
3
10
50
SDA165
RA0008
SDA165FHF
35
6
400
1.85
3
10
75
SDA165
RA0008
SDA165GHF
35
6
600
1.85
3
10
75
SDA165
RA0008
SDA165HHF
35
6
800
2.3
3
10
75
SDA165
RA0008
SDA165AHF
35
10
50
0.95
6
5
125
SDA165
RA0008
SDA165BHF
35
10
100
0.95
6
5
125
SDA165
RA0008
SDA165CHF
35
10
150
0.95
6
5
125
SDA165
RA0008
SDA42AHF
40
14.5
50
1.35
3
10
75
SDA130
RA0059
SDA42BHF
40
14.5
100
1.35
3
10
75
SDA130
RA0059
SDA42CHF
40
14.5
200
1.35
3
10
75
SDA130
RA0059
SDA42DHF
40
14.5
300
1.35
3
10
75
SDA130
RA0059
SDA42EHF
40
14.5
400
1.35
3
10
75
SDA130
RA0059
SDA42FHF
40
14.5
500
1.35
3
10
75
SDA130
RA0059
SDA42GHF
40
14.5
600
1.35
3
10
75
SDA130
RA0059
SDA628A
40
18
50
0.95
6
20
150
SDA267
RA0053
SDA628B
40
18
100
0.95
6
20
150
SDA267
RA0053
SDA628C
40
18
150
0.95
6
20
150
SDA267
RA0053
SDA628E
40
18
250
0.95
6
20
150
SDA267
RA0053
SDA628F
40
18
300
0.95
6
20
150
SDA267
RA0053
SDA803A
50
20
50
0.95
6
5
125
SDA267
RA0040
SDA803B
50
20
100
0.95
6
5
125
SDA267
RA0040
SDA803C
50
20
200
0.95
6
5
125
SDA267
RA0040
SDA803D
50
20
300
0.95
6
5
125
SDA267
RA0040
SDA18A
50
35
200
1.3
10
20
300
SDA130
RA0060
SDA18B
50
35
300
1.3
10
20
300
SDA130
RA0060
SDA18C
50
35
400
1.3
10
20
300
SDA130
RA0060
SDA18D
50
35
500
1.3
10
20
300
SDA130
RA0060
SDA18E
50
35
600
1.3
10
20
300
SDA130
RA0060
SDA18F
50
35
700
1.3
10
20
300
SDA130
RA0060
SDA18G
50
35
800
1.3
10
20
300
SDA130
RA0060
SDA356GUF
60
1
400
1.5
1
5
25
SDA276
RA0056
SDA356JUF
60
1
600
1.5
1
5
25
SDA276
RA0056
(MIL-PRF-19500)
VF @ IF
Data sheets available at www.ssdi-power.com
Jump to Table of Contents
8
Single Phase Bridge Rectifiers
High Reliability Screening Available, See Page 26
Sorted by trr then by IF(AV)
Part Number
All Devices Screened to:
TX, TXV, or S-Level
(MIL-PRF-19500)
Single Phase Bridges - Ratings Based on 25 °C Case Temperature
Maximum
Reverse
Recovery
Time
Average
DC Output
Current
Peak
Inverse
Voltage
Maximum
Forward Voltage
Drop (per leg)
(per leg)
trr
IF(AV)
PIV
nsec
Amps
Volts
VF @ IF
Volts
Amps
Maximum
Leakage
Non-Repetitive
Sinusoidal
Package
Data Sheet
Current
Surge
(@ PIV)
(8.3msec)
Types
Number
IR
Izsm
µA
Amps
SDA356KUF
60
1
800
1.5
1
5
25
SDA276
RA0056
SDA165DUF
60
10
400
1.2
3
10
75
SDA165
RH0237
SDA165EUF
60
10
600
1.2
3
10
75
SDA165
RH0237
SDA356MUF
70
1
1000
1.9
1
5
25
SDA276
RA0056
SDA356NUF
70
1
1200
1.9
1
5
25
SDA276
RA0056
SDA165FUF
70
10
800
1.4
3
10
75
SDA165
RH0237
SDA165GUF
70
10
1000
1.4
3
10
75
SDA165
RH0237
SDA25-3UF
70
10
3000
6
3
5
75
SDA25
RA0004
SDA41AUF
70
14.5
50
1.35
3
20
75
SDA130
RA0058
SDA41BUF
70
14.5
100
1.35
3
20
75
SDA130
RA0058
SDA41CUF
70
14.5
200
1.35
3
20
75
SDA130
RA0058
SDA41DUF
70
14.5
300
1.35
3
20
75
SDA130
RA0058
SDA41EUF
70
14.5
400
1.35
3
20
75
SDA130
RA0058
SDA41FUF
70
14.5
500
1.35
3
20
75
SDA130
RA0058
SDA41GUF
70
14.5
600
1.35
3
20
75
SDA130
RA0058
SDA356BF
100
1
100
1.1
1
5
25
SDA276
RA0056
SDA356DF
100
1
200
1.1
1
5
25
SDA276
RA0056
SDA356GF
100
1
400
1.1
1
5
25
SDA276
RA0056
SDA356JF
100
1
600
1.1
1
5
25
SDA276
RA0056
SDA356KF
100
1
800
1.1
1
5
25
SDA276
RA0056
SDA356MF
100
1
1000
1.3
1
5
25
SDA276
RA0056
SDA356NF
100
1
1200
1.3
1
5
25
SDA276
RA0056
SDA276AF
150
3
50
1.3
3
2
30
SDA276
RA0032
SDA276BF
150
3
100
1.3
3
2
30
SDA276
RA0032
SDA276CF
150
3
200
1.3
3
2
30
SDA276
RA0032
SDA276DF
150
3
400
1.3
3
2
30
SDA276
RA0032
SDA276EF
150
3
600
1.3
3
2
30
SDA276
RA0032
SDA276FF
150
3
800
1.3
3
2
30
SDA276
RA0032
SDA276GF
150
3
1000
1.3
3
2
30
SDA276
RA0032
SDA267A
150
10
50
1.2
---
2
125
SDA267
RA0077
SDA267B
150
10
100
1.2
---
2
125
SDA267
RA0077
SDA267C
150
10
200
1.2
---
2
125
SDA267
RA0077
SDA267D
150
10
400
1.2
---
2
125
SDA267
RA0077
SDA267E
150
10
600
1.2
---
2
125
SDA267
RA0077
SDA267F
150
10
800
1.2
---
2
125
SDA267
RA0077
9
Data sheets available at www.ssdi-power.com
Jump to Table of Contents
Single Phase Bridge Rectifiers
High Reliability Screening Available, See Page 26
Sorted by trr then by IF(AV)
Part Number
All Devices Screened to:
Single Phase Bridges - Ratings Based on 25 °C Case Temperature
Maximum
Reverse
Recovery
Time
TX, TXV, or S-Level
(MIL-PRF-19500)
Average
DC Output
Current
Peak
Inverse
Voltage
Maximum
Forward Voltage
Drop (per leg)
(per leg)
trr
IF(AV)
PIV
nsec
Amps
Volts
VF @ IF
Volts
Amps
Maximum
Leakage
Non-Repetitive
Sinusoidal
Package
Data Sheet
Current
Surge
(@ PIV)
(8.3msec)
Types
Number
IR
Izsm
µA
Amps
SDA267G
150
10
1000
1.2
---
2
125
SDA267
RA0077
SDA263AF-1
200
75
50
1.2
10
5
375
SDA263-1
RA0079
SDA263BF-1
200
75
100
1.2
10
5
375
SDA263-1
RA0079
SDA263CF-1
200
75
200
1.2
10
5
375
SDA263-1
RA0079
SDA263DF-1
200
75
400
1.2
10
5
375
SDA263-1
RA0079
SDA263EF-1
200
75
600
1.2
10
5
375
SDA263-1
RA0079
SDA263FF-1
200
75
800
1.2
10
5
375
SDA263-1
RA0079
SDA263GF-1
200
75
1000
1.2
10
5
375
SDA263-1
RA0079
SDA676-50
500
0.3
5000
11
0.15
3
20
SDA676
RA0076
SDA676-48
500
0.325
4800
11
0.15
3
20
SDA676
RA0076
SDA676-42
500
0.375
4200
9.9
0.15
3
20
SDA676
RA0076
SDA676-36
500
0.425
3600
8.8
0.15
3
20
SDA676
RA0076
SDA676-30
500
0.625
3000
7.7
0.2
3
20
SDA676
RA0076
SDA676-24
500
0.8
2400
5.5
0.2
3
20
SDA676
RA0076
SDA676-18
500
0.85
1800
4.4
0.2
3
20
SDA676
RA0076
SDA676-12
500
1
1200
3.3
0.3
3
10
SDA676
RA0076
SDA276AM
1000
3
50
1.2
3
2
30
SDA276
RA0034
SDA276BM
1000
3
100
1.2
3
2
30
SDA276
RA0034
SDA276CM
1000
3
200
1.2
3
2
30
SDA276
RA0034
SDA276DM
1000
3
400
1.2
3
2
30
SDA276
RA0034
SDA276EM
1000
3
600
1.2
3
2
30
SDA276
RA0034
SDA276FM
1000
3
800
1.2
3
2
30
SDA276
RA0034
SDA276GM
1000
3
1000
1.2
3
2
30
SDA276
RA0034
SDA117A
5000
4
50
1.2
3
2
50
SDA117
RA0074
SDA117B
5000
4
100
1.2
3
2
50
SDA117
RA0074
SDA117C
5000
4
200
1.2
3
2
50
SDA117
RA0074
SDA117D
5000
4
400
1.2
3
2
50
SDA117
RA0074
SDA117E
5000
4
600
1.2
3
2
50
SDA117
RA0074
SDA117F
5000
4
800
1.2
3
2
50
SDA117
RA0074
SDA117G
5000
4
1000
1.2
3
2
50
SDA117
RA0074
SDA138A
5000
10
50
1.1
3
2
100
SDA138
RA0075
SDA165A
5000
10
50
1.1
3
5
75
SDA165
RA0009
SDA304A
5000
10
50
1.1
3
5
75
SDA304
RA0011
SDA138B
5000
10
100
1.1
3
2
100
SDA138
RA0075
SDA165B
5000
10
100
1.1
3
5
75
SDA165
RA0009
Data sheets available at www.ssdi-power.com
Jump to Table of Contents
10
Single Phase Bridge Rectifiers
High Reliability Screening Available, See Page 26
Sorted by trr then by IF(AV)
Part Number
All Devices Screened to:
TX, TXV, or S-Level
Single Phase Bridges - Ratings Based on 25 °C Case Temperature
Maximum
Reverse
Recovery
Time
Average
DC Output
Current
Peak
Inverse
Voltage
Maximum
Forward Voltage
Drop (per leg)
(per leg)
Maximum
Leakage
Non-Repetitive
Current
Surge
(@ PIV)
(8.3msec)
IR
Izsm
Amps
Sinusoidal
Package
Data Sheet
Types
Number
trr
IF(AV)
PIV
nsec
Amps
Volts
Volts
Amps
µA
SDA304B
5000
10
100
1.1
3
5
75
SDA304
RA0011
SDA138C
5000
10
200
1.1
3
2
100
SDA138
RA0075
SDA165C
5000
10
200
1.1
3
5
75
SDA165
RA0009
SDA304C
5000
10
200
1.1
3
5
75
SDA304
RA0011
SDA138D
5000
10
400
1.1
3
2
100
SDA138
RA0075
SDA165D
5000
10
400
1.1
3
5
75
SDA165
RA0009
SDA304D
5000
10
400
1.1
3
5
75
SDA304
RA0011
SDA138E
5000
10
600
1.1
3
2
100
SDA138
RA0075
SDA165E
5000
10
600
1.1
3
5
75
SDA165
RA0009
SDA304E
5000
10
600
1.1
3
5
75
SDA304
RA0011
SDA138F
5000
10
800
1.1
3
2
100
SDA138
RA0075
SDA165F
5000
10
800
1.1
3
5
75
SDA165
RA0009
SDA304F
5000
10
800
1.1
3
5
75
SDA304
RA0011
SDA138G
5000
10
1000
1.1
3
2
100
SDA138
RA0075
SDA165G
5000
10
1000
1.2
3
5
70
SDA165
RA0009
SDA304G
5000
10
1000
1.1
3
5
75
SDA304
RA0011
(MIL-PRF-19500)
VF @ IF
SDA130A
5000
17.5
50
1
5
5
150
SDA130
RA0078
SDA130B
5000
17.5
100
1
5
5
150
SDA130
RA0078
Single Phase Bridge Rectifier Packages:
SDA132
SDA263-1
SDA138
11
Data sheets available at www.ssdi-power.com
Jump to Table of Contents
Single Phase Bridge Rectifiers
High Reliability Screening Available, See Page 26
Sorted by trr then by IF(AV)
Part Number
All Devices Screened to:
Single Phase Bridges - Ratings Based on 25 °C Case Temperature
Maximum
Reverse
Recovery
Time
TX, TXV, or S-Level
Peak
Inverse
Voltage
Average
DC Output
Current
Maximum
Forward Voltage
Drop (per leg)
(per leg)
Maximum
Leakage
Non-Repetitive
Sinusoidal
Package
Data Sheet
Current
Surge
(@ PIV)
(8.3msec)
Types
Number
IR
Izsm
trr
IF(AV)
PIV
nsec
Amps
Volts
Volts
Amps
µA
Amps
SDA130C
5000
17.5
200
1
5
5
150
SDA130
RA0078
SDA130D
5000
17.5
400
1
5
5
150
SDA130
RA0078
SDA130E
5000
17.5
600
1
5
5
150
SDA130
RA0078
SDA130F
5000
17.5
800
1
5
5
150
SDA130
RA0078
SDA130G
5000
17.5
1000
1
5
5
150
SDA130
RA0078
SDA132A
5000
50
50
1.1
25
5
400
SDA132
RA0057
SDA132B
5000
50
100
1.1
25
5
400
SDA132
RA0057
SDA132C
5000
50
200
1.1
25
5
400
SDA132
RA0057
SDA132D
5000
50
400
1.1
25
5
400
SDA132
RA0057
SDA132F
5000
50
800
1.1
25
5
400
SDA132
RA0057
SDA132G
5000
50
1000
1.1
25
5
400
SDA132
RA0057
(MIL-PRF-19500)
VF @ IF
SDA263A-1
5000
100
50
1.2
10
5
375
SDA263-1
RA0080
SDA263B-1
5000
100
100
1.2
10
5
375
SDA263-1
RA0080
SDA263C-1
5000
100
200
1.2
10
5
375
SDA263-1
RA0080
SDA263D-1
5000
100
400
1.2
10
5
375
SDA263-1
RA0080
SDA263E-1
5000
100
600
1.2
10
5
375
SDA263-1
RA0080
SDA263F-1
5000
100
800
1.2
10
5
375
SDA263-1
RA0080
SDA263G-1
5000
100
1000
1.2
10
5
375
SDA263-1
RA0080
Single Phase Bridge Rectifier Packages:
AC
SDA304
AC
SDA25
SDA130
SDA276 (Shown with Bent Lead Option)
Data sheets available at www.ssdi-power.com
Jump to Table of Contents
12
Three Phase Bridge Rectifiers
IO
0.5 Amps to 100 Amps*
PIV
50 Volts to 5,000 Volts*
trr
40 nsec to 5 µsec*
* Higher voltages, higher currents & faster trr available,
please contact SSDI authorized representative or factory.
13
Data sheets available at www.ssdi-power.com
Jump to Table of Contents
Three Phase Bridge Rectifiers
High Reliability Screening Available, See Page 26
Three Phase Bridges - Ratings Based on 25 °C Case Temperature
Sorted by trr then by IF(AV)
Part Number
All Devices Screened to:
Maximum
Reverse
Recovery
Time
TX, TXV, or S-Level
Average
DC Output
Current
Peak
Inverse
Voltage
Maximum
Forward Voltage
Drop (per leg)
(per leg)
Maximum
Leakage
Non-Repetitive
Sinusoidal
Package
Data Sheet
Current
Surge
(@ PIV)
(8.3msec)
Types
Number
IR
Izsm
trr
IF(AV)
PIV
nsec
Amps
Volts
Volts
Amps
µA
Amps
SDA38AHF
40
10
100
1.35
3
10
75
SDA312
RA0030
SDA38BHF
40
10
200
1.35
3
10
75
SDA312
RA0030
SDA38CHF
40
10
300
1.35
3
10
75
SDA312
RA0030
SDA38DHF
40
10
400
1.35
3
10
75
SDA312
RA0030
SDA38EHF
40
10
500
1.35
3
10
75
SDA312
RA0030
SDA38FHF
40
10
600
1.35
3
10
75
SDA312
RA0030
SDA36AHF
40
14
100
1.35
3
10
60
SDA167
RA0070
SDA36BHF
40
14
200
1.35
3
10
60
SDA167
RA0070
SDA36CHF
40
14
300
1.35
3
10
60
SDA167
RA0070
SDA36DHF
40
14
400
1.35
3
10
60
SDA167
RA0070
SDA36EHF
40
14
600
1.35
3
10
60
SDA167
RA0070
SDA36FHF
40
14
600
1.35
3
10
60
SDA167
RA0070
SDA160A
40
40
50
1.2
10
20
150
SDA160
RA0089
SDA160B
40
40
100
1.2
10
20
150
SDA160
SDA160
SDA160C
40
40
150
1.2
10
20
150
SDA160
SDA160
SDA160D
40
40
200
1.2
10
20
150
SDA160
SDA160
SDA160E
40
40
250
1.2
10
20
150
SDA160
SDA160
SDA160F
40
40
300
1.2
10
20
150
SDA160
SDA160
SDA167DUF
50
25
420
1.35
3
10
150
SDA167
RA0042
SDA167DUFT
50
25
420
1.35
3
10
150
SDA167
RA0042
SDA167RDUF
50
25
420
1.35
3
10
150
SDA167
RA0042
SDA167RDUFT
50
25
420
1.35
3
10
150
SDA167
RA0042
SDA167EUF
50
25
620
1.35
3
10
150
SDA167
RA0042
SDA167EUFT
50
25
620
1.35
3
10
150
SDA167
RA0042
SDA167REUF
50
25
620
1.35
3
10
150
SDA167
RA0042
SDA167REUFT
50
25
620
1.35
3
10
150
SDA167
RA0042
SDA167FUF
50
25
820
1.5
3
10
150
SDA167
RA0042
SDA167FUFT
50
25
820
1.5
3
10
150
SDA167
RA0042
SDA167RFUF
50
25
820
1.5
3
10
150
SDA167
RA0042
SDA167RFUFT
50
25
820
1.5
3
10
150
SDA167
RA0042
SDA37AUF
70
10
100
1.35
3
20
75
SDA312
RA0083
SDA37BUF
70
10
200
1.35
3
20
75
SDA312
RA0083
SDA37CUF
70
10
300
1.35
3
20
75
SDA312
RA0083
SDA37DUF
70
10
400
1.35
3
20
75
SDA312
RA0083
SDA37EUF
70
10
500
1.35
3
20
75
SDA312
RA0083
SDA37FUF
70
10
600
1.35
3
20
75
SDA312
RA0083
(MIL-PRF-19500)
VF @ IF
Data sheets available at www.ssdi-power.com
Jump to Table of Contents
14
Three Phase Bridge Rectifiers
High Reliability Screening Available, See Page 26
Sorted by trr then by IF(AV)
Part Number
All Devices Screened to:
TX, TXV, or S-Level
Three Phase Bridges - Ratings Based on 25 °C Case Temperature
Maximum
Reverse
Recovery
Time
Average
DC Output
Current
Peak
Inverse
Voltage
Maximum
Forward Voltage
Drop (per leg)
(per leg)
Maximum
Leakage
Non-Repetitive
Sinusoidal
Package
Data Sheet
Current
Surge
(@ PIV)
(8.3msec)
Types
Number
IR
Izsm
trr
IF(AV)
PIV
nsec
Amps
Volts
Volts
Amps
µA
Amps
SDA35AUF
70
14
100
1.35
3
20
60
SDA167
RA0069
SDA35BUF
70
14
200
1.35
3
20
60
SDA167
RA0069
SDA35CUF
70
14
300
1.35
3
20
60
SDA167
RA0069
SDA35DUF
70
14
400
1.35
3
20
60
SDA167
RA0069
SDA35EUF
70
14
500
1.35
3
20
60
SDA167
RA0069
SDA35FUF
70
14
600
1.35
3
20
60
SDA167
RA0069
SPA560J
70
22
600
1.4
3
10
125
SPA560
RA0091
SPA560K
70
22
800
1.4
3
10
125
SPA560
RA0091
SPA560M
70
22
1000
1.4
3
10
125
SPA560
RA0091
SDA116J
70
25
600
1.4
3
500
125
SDA116
RA0046
SDA116K
70
25
800
1.4
3
500
125
SDA116
RA0046
SDA116M
70
25
1000
1.4
3
500
125
SDA116
RA0046
SDA167HCEUF
70
33
600
1.42
3
20
250
SDA167
RA0018
SDA167HCEUFT
70
33
600
1.42
3
20
250
SDA167
RA0018
SDA167HREUF
70
33
600
1.42
3
20
250
SDA167
RA0018
SDA167HREUFT
70
33
600
1.42
3
20
250
SDA167
RA0018
SDA167HCFUF
70
33
800
1.42
3
20
250
SDA167
RA0018
SDA167HCFUFT
70
33
800
1.42
3
20
250
SDA167
RA0018
SDA167HRFUF
70
33
800
1.42
3
20
250
SDA167
RA0018
SDA167HRFUFT
70
33
800
1.42
3
20
250
SDA167
RA0018
SDA167HCGUF
70
33
1000
1.42
3
20
250
SDA167
RA0018
SDA167HCGUFT
70
33
1000
1.42
3
20
250
SDA167
RA0018
SDA167HRGUF
70
33
1000
1.42
3
20
250
SDA167
RA0018
SDA167HRGUFT
70
33
1000
1.42
3
20
250
SDA167
RA0018
SDA403AF
150
5
50
1.4
3
3
25
SDA403
RA0082
SDA403BF
150
5
100
1.4
3
3
25
SDA403
RA0082
SDA403CF
150
5
200
1.4
3
3
25
SDA403
RA0082
SDA403DF
150
5
400
1.4
3
3
25
SDA403
RA0082
SDA403EF
150
5
600
1.4
3
3
25
SDA403
RA0082
SDA403FF
150
5
800
1.4
3
3
25
SDA403
RA0082
SDA403GF
150
5
1000
1.4
3
3
25
SDA403
RA0082
(MIL-PRF-19500)
VF @ IF
SDA312AF
180
10
50
1.4
3
5
75
SDA312
RC0034
SDA312BF
180
10
100
1.4
3
5
75
SDA312
RC0034
SDA312CF
180
10
200
1.4
3
5
75
SDA312
RC0034
SDA312DF
180
10
400
1.4
3
5
75
SDA312
RC0034
SDA312EF
180
10
600
1.4
3
5
75
SDA312
RC0034
15
Data sheets available at www.ssdi-power.com
Jump to Table of Contents
Three Phase Bridge Rectifiers
High Reliability Screening Available, See Page 26
Sorted by trr then by IF(AV)
Part Number
All Devices Screened to:
Three Phase Bridges - Ratings Based on 25 °C Case Temperature
Maximum
Reverse
Recovery
Time
TX, TXV, or S-Level
Average
DC Output
Current
Peak
Inverse
Voltage
Maximum
Forward Voltage
Drop (per leg)
(per leg)
Maximum
Leakage
Non-Repetitive
Sinusoidal
Package
Data Sheet
Current
Surge
(@ PIV)
(8.3msec)
Types
Number
IR
Izsm
trr
IF(AV)
PIV
nsec
Amps
Volts
Volts
Amps
µA
Amps
SDA312FF
200
10
800
1.4
3
5
75
SDA312
RC0034
SDA312GF
200
10
1000
1.4
3
5
75
SDA312
RC0034
SDA262EF-3
200
50
600
1.2
10
10
240
SDA263-3
RA0014
SDA262FF-3
200
50
800
1.2
10
10
240
SDA263-3
RA0014
SDA262GF-3
200
50
1000
1.2
10
10
240
SDA263-3
RA0014
(MIL-PRF-19500)
VF @ IF
SDA263AF-3
200
75
50
1.2
10
5
375
SDA263-3
RA0064
SDA263BF-3
200
75
100
1.2
10
5
375
SDA263-3
RA0064
SDA263CF-3
200
75
200
1.2
10
5
375
SDA263-3
RA0064
SDA263DF-3
200
75
400
1.2
10
5
375
SDA263-3
RA0064
SDA263EF-3
200
75
600
1.2
10
5u
375
SDA263-3
RA0064
SDA263FF-3
200
75
800
1.2
10
5u
375
SDA263-3
RA0064
SDA263GF-3
200
75
1000
1.2
10
5u
375
SDA263-3
RA0064
SDA667JFl
250
40
600
1.15
3
5u
250
SDA667
RA0022
SDA667JFT
250
40
600
1.15
3
5u
250
SDA667
RA0022
SDA667KFl
250
40
800
1.15
3
5u
250
SDA667
RA0022
SDA667KFT
250
40
800
1.15
3
5u
250
SDA667
RA0022
SDA667MFL
250
40
1000
1.15
3
5
250
SDA667
RA0022
SDA667MFT
250
40
1000
1.15
3
5
250
SDA667
RA0022
SDA253DF
250
50
400
1.25
18
10
300
SDA263-3
RA0049
SDA253EF
250
50
600
1.25
18
10
300
SDA263-3
RA0049
SDA253FF
250
50
800
1.25
18
10
300
SDA263-3
RA0049
SDA294H
5000
0.5
1500
1.1
0.5
1
50
SDA294
RA0081
SDA294J
5000
0.5
2000
1.1
0.5
1
50
SDA294
RA0081
SDA294K
5000
0.5
2500
1.1
0.5
1
50
SDA294
RA0081
SDA294L
5000
0.5
3000
1.1
0.5
1
50
SDA294
RA0081
SDA294A
5000
2
50
1.1
2
1
50
SDA294
RA0081
SDA294B
5000
2
100
1.1
2
1
50
SDA294
RA0081
SDA294C
5000
2
200
1.1
2
1
50
SDA294
RA0081
SDA294D
5000
2
400
1.1
2
1
50
SDA294
RA0081
SDA294E
5000
2
600
1.1
2
1
50
SDA294
RA0081
SDA294F
5000
2
800
1.1
2
1
50
SDA294
RA0081
SDA294G
5000
2
1000
1.1
2
1
50
SDA294
RA0081
SDA113A
5000
3
50
1.1
3
5
50
SDA113
RA0047
SDA113B
5000
3
100
1.1
3
5
50
SDA113
RA0047
SDA113C
5000
3
200
1.1
3
5
50
SDA113
RA0047
SDA113D
5000
3
400
1.1
3
5
50
SDA113
RA0047
Data sheets available at www.ssdi-power.com
Jump to Table of Contents
16
Three Phase Bridge Rectifiers
High Reliability Screening Available, See Page 26
Sorted by trr then by IF(AV)
Part Number
All Devices Screened to:
TX, TXV, or S-Level
(MIL-PRF-19500)
Three Phase Bridges - Ratings Based on 25 °C Case Temperature
Maximum
Reverse
Recovery
Time
Average
DC Output
Current
Peak
Inverse
Voltage
Maximum
Forward Voltage
Drop (per leg)
(per leg)
trr
IF(AV)
PIV
nsec
Amps
Volts
VF @ IF
Volts
Amps
Maximum
Leakage
Non-Repetitive
Current
Surge
(@ PIV)
(8.3msec)
IR
Izsm
µA
Amps
Sinusoidal
Package
Data Sheet
Types
Number
SDA113E
5000
3
600
1.1
3
5
50
SDA113
RA0047
SDA113F
5000
3
800
1.1
3
5
50
SDA113
RA0047
SDA113G
5000
3
1000
1.1
3
5
50
SDA113
RA0047
SDA295A
5000
5
50
1.2
5
2
70
SDA295
RA0010
SDA316A
5000
5
50
1.2
3
3
50
SDA403
RA0036
SDA295B
5000
5
100
1.2
5
2
70
SDA295
RA0010
SDA316B
5000
5
100
1.2
3
3
50
SDA403
RA0036
SDA295C
5000
5
200
1.2
5
2
70
SDA295
RA0010
SDA316C
5000
5
200
1.2
3
3
50
SDA403
RA0036
SDA295D
5000
5
400
1.2
5
2
70
SDA295
RA0010
SDA316D
5000
5
400
1.2
3
3
50
SDA403
RA0036
SDA295E
5000
5
600
1.2
5
2
70
SDA295
RA0010
SDA316E
5000
5
600
1.2
3
3
50
SDA403
RA0036
SDA295F
5000
5
800
1.2
5
2
70
SDA295
RA0010
SDA168H
5000
5
1000
1.1
3
5
150
SDA168
RA0031
SDA295G
5000
5
1000
1.2
5
2
70
SDA295
RA0010
SDA168I
5000
5
1500
2.2
3
5
150
SDA168
RA0031
SDA168J
5000
5
2000
2.2
3
5
150
SDA168
RA0031
SDA168K
5000
5
2500
3.3
3
5
150
SDA168
RA0031
SDA168L
5000
5
3000
3.3
3
5
150
SDA168
RA0031
SDA168M
5000
5
4000
4.4
3
5
150
SDA168
RA0031
SDA168N
5000
5
5000
5.5
3
5
150
SDA168
RA0031
SDA403A
5000
6
50
1.2
3
3
30
SDA403
RA0005
SDA403B
5000
6
100
1.2
3
3
30
SDA403
RA0005
SDA403C
5000
6
200
1.2
3
3
30
SDA403
RA0005
SDA403D
5000
6
400
1.2
3
3
30
SDA403
RA0005
SDA403E
5000
6
600
1.2
3
3
30
SDA403
RA0005
SDA403F
5000
6
800
1.2
3
3
30
SDA403
RA0005
SDA403G
5000
6
1000
1.2
3
3
30
SDA403
RA0005
SDA312A
5000
10
50
1
3
5
75
SDA312
RA0001
SDA312B
5000
10
100
1
3
5
75
SDA312
RA0001
SDA312C
5000
10
200
1
3
5
75
SDA312
RA0001
SDA312D
5000
10
400
1
3
5
75
SDA312
RA0001
SDA312E
5000
10
600
1
3
5
75
SDA312
RA0001
SDA312F
5000
10
800
1
3
5
75
SDA312
RA0001
17
Data sheets available at www.ssdi-power.com
Jump to Table of Contents
Three Phase Bridge Rectifiers
High Reliability Screening Available, See Page 26
Sorted by trr then by IF(AV)
Part Number
All Devices Screened to:
Three Phase Bridges - Ratings Based on 25 °C Case Temperature
Maximum
Reverse
Recovery
Time
TX, TXV, or S-Level
Average
DC Output
Current
Peak
Inverse
Voltage
(per leg)
trr
IF(AV)
PIV
nsec
Amps
Volts
SDA312G
5000
10
SDA167D
5000
25
SDA167DT
5000
SDA167E
(MIL-PRF-19500)
Maximum
Forward Voltage
Drop (per leg)
VF @ IF
Maximum
Leakage
Non-Repetitive
Current
Surge
(@ PIV)
(8.3msec)
IR
Izsm
µA
Amps
Sinusoidal
Package
Data Sheet
Types
Number
Volts
Amps
1000
1
3
5
75
SDA312
RA0001
400
1.2
9
10
150
SDA167
RA0048
25
400
1.2
9
10
150
SDA167
RA0048
5000
25
600
1.2
9
10
150
SDA167
RA0048
SDA167ET
5000
25
600
1.2
9
10
150
SDA167
RA0048
SDA167F
5000
25
800
1.2
9
10
150
SDA167
RA0048
SDA167FT
5000
25
800
1.2
9
10
150
SDA167
RA0048
SDA167G
5000
25
1000
1.2
9
10
150
SDA167
RA0048
SDA167GT
5000
25
1000
1.2
9
10
150
SDA167
RA0048
SDA195
5000
30
100
1.05
15
25
200
SDA195
RA0043
SDA195L
5000
30
100
1.05
15
25
200
SDA195
RA0043
SDA263A-3
5000
100
50
1.2
10
5
375
SDA263-3
RA0071
SDA263B-3
5000
100
100
1.2
10
5
375
SDA263-3
RA0071
SDA263C-3
5000
100
200
1.2
10
5
375
SDA263-3
RA0071
SDA263D-3
5000
100
400
1.2
10
5
375
SDA263-3
RA0071
SDA263E-3
5000
100
600
1.2
10
5
375
SDA263-3
RA0071
SDA263F-3
5000
100
800
1.2
10
5
375
SDA263-3
RA0071
SDA263G-3
5000
100
1000
1.2
10
5
375
SDA263-3
RA0071
Three Phase Bridge Rectifier Packages:
SDA294
SDA113
SDA403
SDA176
SDA312
SDA263-3
Data sheets available at www.ssdi-power.com
Jump to Table of Contents
18
HV Bridges & Assemblies
IO
0.5 Amps to 20 Amps*
PIV
2.5 kV to 20 kV*
trr
35 nsec to 5 µsec*
* Higher voltages, higher currents & faster trr available,
please contact SSDI authorized representative or factory.
19
Data sheets available at www.ssdi-power.com
Jump to Table of Contents
HV Bridges & Assemblies
High Reliability Screening Available, See Page 26
Sorted by trr then by IF(AV)
Part Number
All Devices Screened to:
HV Bridges & Assemblies- Ratings Based on 25 °C Case Temperature
Maximum
Reverse
Recovery
Time
TX, TXV, or S-Level
(MIL-PRF-19500)
Average
DC Output
Current
Peak
Inverse
Voltage
Maximum
Forward Voltage
Drop (per leg)
(per leg)
trr
IF(AV)
PIV
nsec
Amps
Volts
VF @ IF
Volts
Amps
Maximum
Leakage
Non-Repetitive
Sinusoidal
Package
Data Sheet
Current
Surge
(@ PIV)
(8.3msec)
Types
Number
IR
Izsm
µA
Amps
SPA548-01
35
2
2000
6
0.75
5
20
Assembly
PM0022
SPA547-01
40
0.8
3000
8.2
1
1
40
Assembly
PM0021
SDA345
60
1
3000
5.7
1
5
25
Assembly
RA0072
SPX2091
60
1
9300
2.5
1
1
25
Assembly
PM0023
SDA346
60
1
10000
14.5
1
5
25
Assembly
RA0073
SPA513-02
60
1
15000
7.5
1
1
25
Assembly
PM0012
SPA513-03
60
1
17500
7.5
1
1
25
Assembly
PM0012
SPA513-04
60
1
20000
7.5
1
1
25
Assembly
PM0012
SDAD101H15UF
70
0.95
15000
18.9
0.54
20
25
SDAD101
RA0085
SDAD101H10UF
70
1.35
10000
13
0.68
20
125
SDAD101
RA0085
SDAD102H15UF
70
1.4
15000
18.9
0.7
15
100
SDAD102
RA0087
SDAD101H7.5UF
70
1.8
7500
9.9
0.81
20
125
SDAD101
RA0085
SDAH2500UF
70
2
2500
5.5
3
3
75
SDAH HV Stick
RA0003
SDAH5000UF
70
2
5000
9.5
3
3
75
SDAH HV Stick
RA0003
SDAH7500UF
70
2
7500
15
3
3
75
SDAH HV Stick
RA0003
SDAD102H10UF
70
2
10000
13.6
1.2
15
100
SDAD102
RA0087
SDAH10000UF
70
2
10000
19
3
3
75
SDAH HV Stick
RA0003
SDAH12500UF
70
2
12500
24.5
3
3
75
SDAH HV Stick
RA0003
SDAH15000UF
70
2
15000
28.5
3
3
75
SDAH HV Stick
RA0003
SDAH20000UF
70
2
20000
38
3
3
75
SDAH HV Stick
RA0003
SDAH25000UF
70
2
25000
47.5
3
3
75
SDAH HV Stick
RA0003
SDAD101H5.0UF
70
2.34
5000
6.71
0.95
20
125
SDAD101
RA0085
SPA516L-3UF
70
3
3000
5.7
3
10
75
Assembly
RA0020
SDAD102H7.5UF
70
3
7500
10.9
1.5
15
125
SDAD102
RA0087
SDAD103H15UF
70
3
15000
19.2
1.44
10
125
SDAD103
RA0084
SDA475-02
70
3
18000
10
0.6
2
25
Assembly
PM0005
SDAD101H2.5UF
70
3.6
2500
3.96
1.62
20
125
SDAD101
RA0085
SDAD103H10UF
70
4.5
10000
13.85
2.25
10
125
SDAD103
RA0084
SDAD103H7.5UF
70
7.2
7500
10.1
3.6
20
200
SDAD103
RA0084
SDAD102H5.0UF
70
8.8
5000
7.92
4.5
30
200
SDAD102
RA0087
SDAD102H2.5UF
70
10.6
2500
4.35
6.3
30
200
SDAD102
RA0087
SDAD103H5.0UF
70
10.8
5000
7.6
5.4
30
200
SDAD103
RA0084
SDAD103H2.5UF
70
14.4
2500
3.9
7.2
30
200
SDAD103
RA0084
SDA2500UF
80
0.5
2500
5.5
2
2
25
SDA HV Stick
RA0006
Data sheets available at www.ssdi-power.com
Jump to Table of Contents
20
HV Bridges & Assemblies
High Reliability Screening Available, See Page 26
Sorted by trr then by IF(AV)
Part Number
All Devices Screened to:
TX, TXV, or S-Level
(MIL-PRF-19500)
HV Bridges & Assemblies- Ratings Based on 25 °C Case Temperature
Maximum
Reverse
Recovery
Time
Average
DC Output
Current
Peak
Inverse
Voltage
Maximum
Forward Voltage
Drop (per leg)
(per leg)
trr
IF(AV)
PIV
nsec
Amps
Volts
Volts
VF @ IF
Amps
Maximum
Leakage
Non-Repetitive
Current
Surge
(@ PIV)
(8.3msec)
IR
Izsm
µA
Amps
Sinusoidal
Package
Data Sheet
Types
Number
SDA5000UF
80
0.5
5000
9.5
2
2
25
SDA HV Stick
RA0006
SDA7500UF
80
0.5
7500
15
2
2
25
SDA HV Stick
RA0006
SDA10000UF
80
0.5
10000
19
2
2
25
SDA HV Stick
RA0006
SDA12500UF
80
0.5
12500
24.5
2
2
25
SDA HV Stick
RA0006
SDA15000UF
80
0.5
15000
28.5
2
2
25
SDA HV Stick
RA0006
SDA20000UF
80
0.5
20000
38
2
2
25
SDA HV Stick
RA0006
SDA25000UF
80
0.5
25000
47.5
2
2
25
SDA HV Stick
RA0006
SPA516-2F
150
10
2000
4.4
10
10
75
Assembly
RA0019
SDA2500F
180
0.5
2500
4.5
2
2
25
SDA HV Stick
RA0007
SDA5000F
180
0.5
5000
7.5
2
2
25
SDA HV Stick
RA0007
SDA7500F
180
0.5
7500
12
2
2
25
SDA HV Stick
RA0007
SDA10000F
180
0.5
10000
15
2
2
25
SDA HV Stick
RA0007
SDA12500F
180
0.5
12500
19.5
2
2
25
SDA HV Stick
RA0007
SDA15000F
180
0.5
15000
22.5
2
2
25
SDA HV Stick
RA0007
SDA20000F
180
0.5
20000
30
2
2
25
SDA HV Stick
RA0007
SDA25000F
180
0.5
25000
37.5
2
2
25
SDA HV Stick
RA0007
SDAD101S10F
500
0.58
10000
23
0.3
5
20
SDAD101
RA0041
SDAD102C15F
500
0.7
15000
30
0.25
2
25
SDAD102
RA0086
SDAD101S7.5F
500
0.75
7500
18
0.4
5
20
SDAD101
RA0041
SDAD101S5.0F
500
0.9
5000
12
0.5
5
20
SDAD101
RA0041
SDAD101B7.5F
500
1
7500
18
0.4
10
70
SDAD101
RA0041
SDAD102C10F
500
1
10000
20
0.37
2
25
SDAD102
RA0086
SDAD101H15F
500
1.06
15000
17.2
0.5
10
30
SDAD101
RA0041
SDAD102C7.5F
500
1.25
7500
15
0.5
2
25
SDAD102
RA0086
SDAD101B5.0F
500
1.3
5000
12
0.6
10
70
SDAD101
RA0041
SDAD102H15F
500
1.4
15000
17.2
0.8
10
100
SDAD102
RA0086
SDAD102D7.5F
500
1.5
7500
17
0.5
5
80
SDAD102
RA0086
SDAD101H10F
500
1.5
10000
11.8
0.8
10
150
SDAD101
RA0041
SDAD103C15F
500
1.67
15000
27
0.65
5
30
SDAD103
RA0065
SDAD102C5.0F
500
1.7
5000
10
0.7
2
25
SDAD102
RA0086
SDAD101B2.5F
500
2
2500
6
0.9
10
70
SDAD101
RA0041
SDAD102D5.0F
500
2
5000
11
0.75
5
80
SDAD102
RA0086
SDAD101H7.5F
500
2
7500
9
0.9
10
150
SDAD101
RA0041
SDAD102H10F
500
2
10000
12
1.3
10
100
SDAD102
RA0086
SDAD103D10F
500
2.5
10000
22
0.85
5
80
SDAD103
RA0065
21
Data sheets available at www.ssdi-power.com
Jump to Table of Contents
HV Bridges & Assemblies
High Reliability Screening Available, See Page 26
Sorted by trr then by IF(AV)
Part Number
All Devices Screened to:
HV Bridges & Assemblies- Ratings Based on 25 °C Case Temperature
Maximum
Reverse
Recovery
Time
TX, TXV, or S-Level
(MIL-PRF-19500)
Average
DC Output
Current
Peak
Inverse
Voltage
Maximum
Forward Voltage
Drop (per leg)
(per leg)
trr
IF(AV)
PIV
nsec
Amps
Volts
VF @ IF
Volts
Amps
Maximum
Leakage
Non-Repetitive
Sinusoidal
Package
Data Sheet
Current
Surge
(@ PIV)
(8.3msec)
Types
Number
IR
Izsm
µA
Amps
SDAD101H5.0F
500
2.6
5000
6.1
1.1
10
150
SDAD101
RA0041
SDAD102H7.5F
500
3
7500
9.6
1.7
10
125
SDAD102
RA0086
SDAD102D2.5F
500
3.3
2500
6
1.2
5
80
SDAD102
RA0086
SDAD103H15F
500
3.33
15000
17.2
1.6
10
125
SDAD103
RA0065
SDAD103D7.5F
500
3.5
7500
17
1.1
5
80
SDAD103
RA0065
SDAD101H2.5F
500
4
2500
3.6
1.8
10
150
SDAD101
RA0041
SDAD103F7.5F
500
4
7500
17
1.2
10
150
SDAD103
RA0065
SDAD102F5.0F
500
4.4
5000
11
1.6
10
150
SDAD102
RA0086
SDAD103D5.0F
500
4.8
5000
11
1.6
5
80
SDAD103
RA0065
SDAD103H10F
500
5
10000
12
2.5
10
125
SDAD103
RA0065
SDAD102F2.5F
500
5.3
2500
6
2.2
10
150
SDAD102
RA0086
SDAD103F5.0F
500
6
5000
11
1.8
10
150
SDAD103
RA0065
SDAD103F2.5F
500
8
2500
6
2.5
10
150
SDAD103
RA0065
SDAD103H7.5F
500
8
7500
8.65
4
20
200
SDAD103
RA0065
SDAD102H5.0F
500
8.8
5000
7.2
5
20
200
SDAD102
RA0086
SDAD102H2.5F
500
10.6
2500
4.05
7
20
200
SDAD102
RA0086
SDAD103H5.0F
500
12
5000
6.8
6.2
30
200
SDAD103
RA0065
SDAD103H2.5F
500
16
2500
3.3
8
30
200
SDAD103
RA0065
SDA5000
5000
0.5
5000
5
0.5
1
50
SDA HV Stick
RC0079
SDA7500
5000
0.5
7500
7.5
0.5
1
50
SDA HV Stick
RC0079
SDA10000
5000
0.5
10000
10
0.5
1
50
SDA HV Stick
RC0079
SDA12500
5000
0.5
12500
12.5
0.5
1
50
SDA HV Stick
RC0079
SDA15000
5000
0.5
15000
15
0.5
1
50
SDA HV Stick
RC0079
SDA20000
5000
0.5
20000
20
0.5
1
50
SDA HV Stick
RC0079
SDA25000
5000
0.5
25000
25
0.5
1
50
SDA HV Stick
RC0079
SDAD101S15
5000
0.51
15000
25
0.2
5
25
SDAD101
RA0068
SDAD101S10
5000
0.71
10000
17
0.3
5
25
SDAD101
RA0068
SDAD102A15
5000
0.9
15000
25
0.33
2
30
SDAD102
RA0067
SDAD101S7.5
5000
0.91
7500
13
0.5
5
25
SDAD101
RA0068
SDAD101B10
5000
1
10000
17
0.4
10
80
SDAD101
RA0068
SDAD101H15
5000
1
15000
15.7
0.5
10
30
SDAD101
RA0068
SDAD101S5.0
5000
1.1
5000
9
0.6
5
25
SDAD101
RA0068
SDAD101B7.5
5000
1.2
7500
13
0.7
10
80
SDAD101
RA0068
SDAD102A10
5000
1.4
10000
16
0.5
2
30
SDAD102
RA0067
SDAD101B5.0
5000
1.5
5000
9
0.7
10
80
SDAD101
RA0068
Data sheets available at www.ssdi-power.com
Jump to Table of Contents
22
HV Bridges & Assemblies
High Reliability Screening Available, See Page 26
Sorted by trr then by IF(AV)
Part Number
All Devices Screened to:
TX, TXV, or S-Level
HV Bridges & Assemblies- Ratings Based on 25 °C Case Temperature
Maximum
Reverse
Recovery
Time
Average
DC Output
Current
Peak
Inverse
Voltage
(per leg)
trr
IF(AV)
PIV
nsec
Amps
Volts
SDAD102A7.5
5000
1.75
SDAD102H15
5000
1.8
SDAH2500
5000
2
SDAH5000
5000
SDAD102B7.5
5000
(MIL-PRF-19500)
Maximum
Forward Voltage
Maximum
Leakage
Drop (per leg)
VF @ IF
Non-Repetitive
Sinusoidal
Package
Data Sheet
Current
Surge
(@ PIV)
(8.3msec)
Types
Number
IR
Izsm
µA
Amps
Volts
Amps
7500
12
0.6
2
30
SDAD102
RA0067
15000
17.6
1.1
10
100
SDAD102
RA0067
2500
3
1
1
150
SDAH HV Stick
RA0028
2
5000
6
1
1
150
SDAH HV Stick
RA0028
2
7500
12
0.7
5
100
SDAD102
RA0067
SDAH7500
5000
2
7500
8
1
1
150
SDAH HV Stick
RA0028
SDAD101H10
5000
2
10000
10.7
0.8
10
150
SDAD101
RA0068
SDAH10000
5000
2
10000
11
1
1
150
SDAH HV Stick
RA0028
SDAH12500
5000
2
12500
13.5
1
1
150
SDAH HV Stick
RA0028
SDAH15000
5000
2
15000
16
1
1
150
SDAH HV Stick
RA0028
SDAD103A15
5000
2.07
15000
25
0.72
2
30
SDAD103
RA0066
SDAD102A5.0
5000
2.2
5000
8
0.82
2
30
SDAD102
RA0067
SDAD101B2.5
5000
2.3
2500
5
1.1
10
80
SDAD101
RA0068
SDAD101H7.5
5000
2.4
7500
8.2
1
10
150
SDAD101
RA0068
SDAD102B5.0
5000
2.75
5000
8
1
5
100
SDAD102
RA0067
SDAD102H10
5000
2.8
10000
12.1
1.8
10
100
SDAD102
RA0067
SDAD101H5.0
5000
3
5000
5.5
1.3
10
150
SDAD101
RA0068
SDAD103B10
5000
3.5
10000
17
1.1
5
100
SDAD103
RA0066
SDAD102H7.5
5000
4
7500
8.85
2
10
125
SDAD102
RA0067
SDAD103H15
5000
4.14
15000
16.8
2.8
10
125
SDAD103
RA0066
SDAD102B2.5
5000
4.25
2500
4
1.5
5
100
SDAD102
RA0067
SDAD101H2.5
5000
4.6
2500
3.3
2.2
10
150
SDAD101
RA0068
SDAD103B7.5
5000
4.8
7500
13
1.5
5
100
SDAD103
RA0066
SDAD103B7.5
5000
5
7500
13
1.6
10
200
SDAD103
RA0066
SDAD102E5.0
5000
5.5
5000
10
2.2
10
200
SDAD102
RA0067
SDAD102H5.0
5000
5.5
5000
6.8
3.5
20
250
SDAD102
RA0067
SDAD103B5.0
5000
6.6
5000
9
2.2
5
100
SDAD103
RA0066
SDAD103H10
5000
7
10000
12.1
3.5
10
150
SDAD103
RA0066
SDAD103E5.0
5000
7.5
5000
10
2.5
15
200
SDAD103
RA0066
SDAD102E2.5
5000
7.7
2500
5
3
10
200
SDAD102
RA0067
SDAD103E2.5
5000
10
2500
5
3.3
10
200
SDAD103
RA0066
SDAD103H7.5
5000
10
7500
8.45
5
20
250
SDAD103
RA0066
SDAD102H2.5
5000
14.4
2500
3.4
10
20
250
SDAD102
RA0067
SDAD103H5.0
5000
15
5000
6.2
8
30
300
SDAD103
RA0066
SDAD103H2.5
5000
20
2500
3.1
10
30
300
SDAD103
RA0066
23
Data sheets available at www.ssdi-power.com
Jump to Table of Contents
HV Bridges & Assemblies
SDAD101 Outline:
.230”- .235”
.020”- .040”
.97”- 1.00”
CATHODE
10-32
THRD.
10-32
THRD.
.980”- 1.10”
SDAD102 Outline:
.320”- .330”
Ø1.900” MAX
.670”
Ø .570”
.300”
.220”
.78”
MAX
CATHODE
Ø.250-28 UNF-2A
Ø.250-28 UNF-2B
.35±.05 DEEP
SDAD103 Outline*:
Ø 3.030"
2.970"
Ø3.490" MAX
.316"
MAX
1.020"
MAX
.375-24 UNF-2B x
.320" MIN
Ø1.030"
MAX
.375-24 UNF-2A
Ø1.000" MAX
* See Pages 27 and 28 for Data Sheets,
Data sheets available at www.ssdi-power.com
Jump to Table of Contents
24
Three Phase Schottky Modules
High Reliability Screening Available, See Next Page.
Sorted by IF(AV) then by PIV
3-Phase Schottky Modules - Ratings Based on 25 °C Case Temperature
Part Number
All Devices Screened to:
TX, TXV, or S-Level
Data Sheet
Average
DC Output
Current
Number
(MIL-PRF-19500)
Peak
Inverse
Voltage
Maximum
Reverse
Recovery
Maximum
Forward Voltage
Drop (per leg)
Time
(per leg)
Maximum
Leakage
Non-Repetitive
Sinusoidal
Current
Surge
(@ PIV)
(8.3msec)
IR
Izsm
IF(AV)
PIV
Trr
Amps
Volts
nsec
Volts
Amps
mA
Amps
VF @ IF
Package
Types
SPMR527B10
PM0014
320
100
Schottky
0.71
106
5
1000
Assembly
SPMR527F10
PM0014
320
100
Schottky
0.71
106
5
1000
Assembly
SPMR527M10
PM0014
320
100
Schottky
0.71
106
5
1000
Assembly
SPMR527B03
PM0014
400
30
Schottky
0.46
133
7.5
1000
Assembly
SPMR527F03
PM0014
400
30
Schottky
0.46
133
7.5
1000
Assembly
SPMR527M03
PM0014
400
30
Schottky
0.46
133
7.5
1000
Assembly
SPMR527B04
PM0014
400
45
Schottky
0.55
133
12
1000
Assembly
SPMR527F04
PM0014
400
45
Schottky
0.55
133
12
1000
Assembly
SPMR527M04
PM0014
400
45
Schottky
0.55
133
12
1000
Assembly
Three Phase Bridge Power Module
l
l
l
l
l
l
l
l
l
3-Phase High Current Schottky Bridge Rectifier
No Minority Carrier Switching Loss
Electrically Isolated Baseplate
Hermetically Sealed Packaging
Utilizes DBCu/Al2O3 for Low Loss Operation
Low Weight Al-SiC Baseplate
Available with Male (M), Female (F) or Blade (B) Terminals
TX, TXV, and S-Level Screening Available
See Data Sheet # PM0014
ASPM
SPMR527 Electrical Schematic:
SPMR527M03 SPMR527M04 SPMR527M10
SPMR527F03 SPMR527F04 SPMR527F10
SPMR527B03 SPMR527B04 SPMR527B10
25
Data sheets available at www.ssdi-power.com
Jump to Table of Contents
High Reliability Screening
Solid State Devices Screening Per MIL-PRF-19500 Guidelines*
TX Level
TXV Level
Equivalent
Equivalent
S Level
Equivalent
Lot Acceptance
Temperature Cycling
Internal Visual1/
Internal Visual1/
Temperature Cycling
Temperature Cycling
Surge
Surge
Surge
(as specified)
(as specified)
(as specified)
Thermal Resp.
Thermal Resp.
Thermal Resp.
(as specified)
(as specified)
(as specified)
Acceleration
(some excluded)
Serialize
Interim Electrical
(case mount only)
Interim Electrical
(case mount only)
HTRB
HTRB
Interim Electrical
Read & Record
HTRB
48 hrs.
48 hrs.
48 hrs.
Interim Electrical
& Delta
Interim Electrical
& Delta
Interim Electrical
& Delta
Burn-in
Burn-in
Burn-in
Tran. & FET 160 hrs.
Diode & SCR HTRB 96 hrs.
Tran. & FET 160 hrs.
Diode & SCR HTRB 96 hrs.
Interim Electrical
& Delta
Interim Electrical
& Delta
Interim Electrical
& Delta
Hermeticity
Hermeticity
PIND
Case Isolation
Hermeticity
(N/A case mount)
Case Isolation
(case isolated packages only)
240 hrs.
(N/A case mount)
(case isolated packages only)
Note: 1/ X-ray in lieu of internal visual for COTS origin parts
X-Ray
External Visual
Case Isolation
(case isolated packages only)
*Specific Product Types May Have Alternate Screening Flows
Contact your local SSDI Representative or contact the factory directly at (562) 404-4474.
Email- [email protected]
26
Jump to Table of Contents
High Reliability Hermetically
Sealed Rectifier Assemblies
Version 1.36 - 06/24/2015
Solid State Devices, Inc.
14701 Firestone Blvd.
La Mirada, CA 90638
Phone (562) 404-4474
Fax (562) 404-1773
www.ssdi-power.com
[email protected]
Sales Representatives:
Domestic
International
CentraMark Technical
Sales Associates
TX, OK, AR, LA
P.O. Box 450877
Garland, TX 75045-0877
Phone: 972-414-8188
Fax: 972-414-6788
Brazil
Techso
Rua Fradique Coutinho, 316 - Cj 41
Sao Paulo - SP
05416-000 Brazil
(55-11) 3120 5968
[email protected]
ETSI, LLC.
DC, VA, MD
3 Church Circle, Suite 120
Annapolis, MD 21401
Phone: 410-974-9351
Fax: 410-974-8247
Giesting & Associates
OH, Western PA, IN, MI
2854 Blue Rock Rd.
Cincinnati, OH 45239
513-385-1105
[email protected]
Scientific Devices - Phila, Inc.
East PA, South NJ, DE
1635 Clemens Rd.
Harleysville, PA 19438
215-256-8641
[email protected]
SouthTech Marketing, LLC
AL, FL, GA, MS, NC,
Puerto Rico, SC
8213 Nantahala Dr.
Raleigh, NC 27612
919-781-0444
[email protected]
W. Howard Associates, Inc.
CO, UT
12353 E. Easter Ave. Suite 200
Centennial, CO 80112
303-766-5755
[email protected]
Entire contents copyright © 2015
Solid State Devices, Inc.
All Rights Reserved.
China
Rironic Electronic
Technology Co., Ltd Room 1206
China Development Bank Building
No 2 First Gaoxin Road
Xi’an City, Shaanxi Province
P.R. China
+86-029-68683866
[email protected]
www.rironic.com
Denmark / Finland /
Norway / Sweden
Expando Electronics AB
Mörby Centrum, Plan 7
S-182 31 Danderyd, Sweden
+468 54490044
France
AR France
7 Rue du fosse blanc - Bat. D1
92230 Gennevilliers, France
+33 (0)1 47 91 75 30
[email protected]
Germany
MES Manz Electronic
Systeme OHG
Hauptstrasse 46/1
D-74369 Löchgau, Germany
+49-7143-4031-0
India
Irys Electronics
261/2 Plot 4 & 5, Silver Oak Park
Baner Rd, Baner Pune 411045, India
91 20 2729 1836
[email protected]
Israel
FMS Aerospace Ltd.
12 Kehilat Venezia Street
Tel-Aviv 69400, Israel
972-3-6094977
[email protected]
Italy
Milano Brothers
Viale Enrico Fermi 79
00146 Roma, Italy
+39 3384969298
[email protected]
USA Office:
1456 Newport Center Drive
Deerfield Beach, FL 33442
954-420-5000
Japan
Sojitz Aerospace
Marunouchi Trust Tower Main
4th Floor, 8-3
Marunouchi 1-chome
Chiyoda-Ku
Tokyo, Japan 100-0005
+81-3-6870-7211
South Korea
CBOL Corporation
19850 Plummer St.
Chatsworth, CA 91311
818-721-5510
[email protected]
Turkey
IMCA Elektronik ve Bilisim
Sanayi ve Ticaret A.S.
Acibadem mah. Cecen sok.
Akasya Acibadem AVM A
Kule Blok no: 25 A/197
34660 Uskudar
Istanbul, Turkey
+90 216 504 07 87
www.imca.com.tr
[email protected]
United Kingdom / Ireland
Johnson Group Services
(JGS)
The Ryder Cloisters
36, Evelyn Road
Dunstable, Bedfordshire
LU5 4NG
United Kingdom
+44 (0) 1582 603439
[email protected]
Jump to Table of Contents