High Reliability Hermetically Sealed Rectifier Assemblies Shortform Catalog 2015 Bridge Rectifier Assemblies and High Voltage Rectifier Assemblies: Solid State Devices, Inc. 14701 Firestone Blvd., La Mirada, CA 90638 Phone- 562-404-4474 Internet- www.ssdi-power.com Jump to Table of Contents Doublers- Centertap l Single-Phase Bridges l Three-Phase Bridges l HV Bridge Series l HV Assemblies l 3-Phase Schottky Modules l Solid State Devices, Inc. This book represents technical data for the line of Solid State Devices, Inc. High Reliability Hermetically Sealed Rectifier Assemblies. Complete specifications for the individual devices are provided in the form of data sheets from our web site: www.ssdi-power.com The information in this book has been carefully checked and is believed to be accurate; however, no responsibility is assumed for errors or omissions. Solid State Devices, Inc. reserves the right to make changes without further notice to any product herein. Solid State Devices, Inc. does not assume liability arising out of the application or use of any product or circuit described herein; neither does it convey any license under its patent rights nor the rights of others. ™ Solid State Devices, Inc. and are registered trademarks of Solid State Devices, Inc. Solid State Devices, Inc. is an Equal Opportunity/Affirmative Action Employer. Warnings Due to technical requirements, components may contain dangerous substances. For information on the types in question, please contact SSDI. SSDI components may only be used in life-support devices or systems with the express written approval of SSDI. Failure of such components can reasonably be expected to cause the failure of that life-support device or system, or to affect the safety or effectiveness of that device or system. Life support devices or systems are intentionally implanted in the human body, or to support and/or maintain and/or protect human life. If they fail, it is reasonable to assume that the health of the user or other persons may be endangered. Solid State Devices is AS9100C and ISO 9001 Certified Entire contents copyright © 2015 Solid State Devices, Inc. All Rights Reserved. No part of this catalog may be reproduced, transmitted, rewritten, scanned, stored mechanically or electronically, translated into other languages, or adapted for any use without the express written permission of Solid State Devices, Inc. 1 Jump to Table of Contents Table of Contents Doublers- Centertap* 9A to 120A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page Single Phase Bridge Rectifiers* 300mA to 100A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page Three Phase Bridge Rectifiers* 500mA to 100A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . High Voltage Bridges & Assemblies* 500mA to 20A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Three Phase Schottky Modules* 320A to 400A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . High Reliability Screening Flow TX, TXV, and S-Level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sales Representatives 7 Page 13 Page 19 Page 25 Page 26 Worldwide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Back * High Reliability Screening Available, See Page 26. 3 Cover 2 Doublers- Centertap IO 9 Amps to 120 Amps* PIV 35 Volts to 1,000 Volts* trr 40 nsec to 5 µsec* * Higher voltages, higher currents & faster trr available, please contact SSDI authorized representative or factory. 3 Data sheets available at www.ssdi-power.com Jump to Table of Contents Doublers- Centertap High Reliability Screening Available, See Page 26 Doublers- Centertap - Ratings Based on 25 °C Case Temperature Sorted by trr then by IF(AV) Part Number All Devices Screened to: Maximum Reverse Recovery Time TX, TXV, or S-Level (MIL-PRF-19500) Average DC Output Current Peak Inverse Voltage (per leg) trr IF(AV) PIV nsec Amps Volts Maximum Forward Voltage Maximum Leakage Drop (per leg) VF @ IF Volts Amps Non-Repetitive Sinusoidal Package Data Sheet Current Surge (@ PIV) (8.3msec) Types Number IR Izsm µA Amps SDA240A Schottky 120 35 0.65 60 300 800 SDA240 RS0297 SDA240B Schottky 120 45 0.65 60 300 800 SDA240 RS0297 SDAI03A_HF 30 30 150 1.1 9 10 175 SDAI03 RA0090 SDA40AHF 40 9 50 1.35 3 10 75 SDA280 RA0055 SDA40BHF 40 9 100 1.35 3 10 75 SDA280 RA0055 SDA40CHF 40 9 200 1.35 3 10 75 SDA280 RA0055 SDA40DHF 40 9 300 1.35 3 10 75 SDA280 RA0055 SDA40EHF 40 9 400 1.35 3 10 75 SDA280 RA0055 SDA40FHF 40 9 500 1.35 3 10 75 SDA280 RA0055 SDA40GHF 40 9 600 1.35 3 10 75 SDA280 RA0055 SDA480AD 40 20 50 0.95 6 20 150 SDA180 RA0037 SDA480AN 40 20 50 0.95 6 20 150 SDA180 RA0037 SDA480AP 40 20 50 0.95 6 20 150 SDA180 RA0037 SDA480BD 40 20 100 0.95 6 20 150 SDA180 RA0037 SDA480BN 40 20 100 0.95 6 20 150 SDA180 RA0037 SDA480BP 40 20 100 0.95 6 20 150 SDA180 RA0037 SDA480CD 40 20 150 0.95 6 20 150 SDA180 RA0037 SDA480CN 40 20 150 0.95 6 20 150 SDA180 RA0037 SDA480CP 40 20 150 0.95 6 20 150 SDA180 RA0037 SDA480DD 40 20 200 0.95 6 20 150 SDA180 RA0037 SDA480DN 40 20 200 0.95 6 20 150 SDA180 RA0037 SDA480DP 40 20 200 0.95 6 20 150 SDA180 RA0037 SDA480ED 40 20 250 0.95 6 20 150 SDA180 RA0037 SDA480EN 40 20 250 0.95 6 20 150 SDA180 RA0037 SDA480EP 40 20 250 0.95 6 20 150 SDA180 RA0037 SDA480FD 40 20 300 0.95 6 20 150 SDA180 RA0037 SDA480FN 40 20 300 0.95 6 20 150 SDA180 RA0037 SDA480FP 40 20 300 0.95 6 20 150 SDA180 RA0037 SDA382A 50 10 50 1.5 3 10 75 SDA380 RA0025 SDA382B 50 10 100 1.5 3 10 75 SDA380 RA0025 SDA382C 50 10 200 1.5 3 10 75 SDA380 RA0025 SDA382D 50 10 400 1.5 3 10 75 SDA380 RA0025 SDA382E 60 10 600 1.7 3 10 75 SDA380 RA0025 SDA382F 70 10 800 1.9 3 10 75 SDA380 RA0025 SDA382G 70 10 1000 1.9 3 10 75 SDA380 RA0025 SDA280A 150 15 50 1.4 5 5 150 SDA280 A00045 Data sheets available at www.ssdi-power.com Jump to Table of Contents 4 Doublers- Centertap High Reliability Screening Available, See Page 26 Sorted by trr then by IF(AV) Part Number All Devices Screened to: TX, TXV, or S-Level Doublers- Centertap - Ratings Based on 25 °C Case Temperature Maximum Reverse Recovery Time Average DC Output Current Peak Inverse Voltage (per leg) Maximum Forward Voltage Maximum Leakage Drop (per leg) Non-Repetitive Sinusoidal Package Data Sheet Current Surge (@ PIV) (8.3msec) Types Number IR Izsm trr IF(AV) PIV nsec Amps Volts Volts Amps µA Amps SDA280B 150 15 100 1.4 5 5 150 SDA280 A00045 SDA280C 150 15 200 1.4 5 5 150 SDA280 A00045 SDA280D 150 15 400 1.4 5 5 150 SDA280 RA0050 SDAI03E_F 150 20 1000 2.2 9 1 150 SDAI03 RA0090 SDAI03B_F 150 30 400 1.5 9 1 150 SDAI03 RA0090 SDA280F 180 15 800 1.4 5 5 150 SDA280 RA0050 SDA280G 180 15 1000 1.4 5 5 150 SDA280 RA0050 SDAI03C 2000 30 600 1.2 9 1 150 SDAI03 RA0090 SDAI03E 2000 30 1000 1.2 9 1 150 SDAI03 RA0090 SDA380B 4000 10 100 1 5 5 150 SDA380 RA0023 SDA380A 5000 10 50 1.2 5 5 75 SDA380 RA0023 SDA381A 5000 10 50 1.35 3 5 75 SDA380 RA0024 SDA381B 5000 10 100 1.35 3 5 75 SDA380 RA0024 SDA380C 5000 10 200 1.2 5 5 75 SDA380 RA0023 SDA381C 5000 10 200 1.35 3 5 75 SDA380 RA0024 SDA380D 5000 10 400 1.2 5 5 75 SDA380 RA0023 SDA381D 5000 10 400 1.35 3 5 75 SDA380 RA0024 SDA380E 5000 10 600 1.2 5 5 75 SDA380 RA0023 SDA381E 5000 10 600 1.45 3 5 75 SDA380 RA0024 SDA380F 5000 10 800 1.2 5 5 75 SDA380 RA0023 SDA381F 5000 10 800 1.35 3 5 75 SDA380 RA0024 SDA380G 5000 10 1000 1.2 5 5 75 SDA380 RA0023 SDA381G 5000 10 1000 1.55 3 5 75 SDA380 RA0024 (MIL-PRF-19500) VF @ IF SDA180A 5000 15 50 1 5 1 150 SDA180 RA0033 SDA180B 5000 15 100 1 5 1 150 SDA180 RA0033 SDA180C 5000 15 200 1 5 1 150 SDA180 RA0033 SDA180D 5000 15 400 1 5 1 150 SDA180 RA0033 SDA180E 5000 15 600 1 5 1 150 SDA180 RA0033 SDA180F 5000 15 800 1 5 1 150 SDA180 RA0033 SDA180G 5000 15 1000 1 5 1 150 SDA180 RA0033 SDA188A 5000 50 50 1.05 25 1 500 Assembly RA0035 SDA188B 5000 50 100 1.05 25 1 500 Assembly RA0035 SDA188C 5000 50 200 1.05 25 1 500 Assembly RA0035 SDA188D 5000 50 400 1.05 25 1 500 Assembly RA0035 SDA188E 5000 50 600 1.05 25 1 500 Assembly RA0035 SDA188F 5000 50 800 1.05 25 1 500 Assembly RA0035 SDA188G 5000 50 1000 1.05 25 1 500 Assembly RA0035 5 Data sheets available at www.ssdi-power.com Jump to Table of Contents Doublers- Centertap SDA180 Outline: 1.880" 1.870" .175" 2x Ø .165" .354" .334" 3x Ø .095" .088" 1.490" 1.470" 1.00" MAX 1 .500" MAX 2 3 2.260" 2.240" SDA180 .135" .115" SDA280 Outline: 1.880” 1.870” .175” 2x Ø .165” .354” .334” 1.490” 1.470” .660” MAX SDA280 .385” .300” 1 3 2 .135” .115” 2.260” 2.240” SDA380 Outline: .045" REF .700" MAX .305" MAX 1.885" 1.865" Ø.090" REF 1 2 3 .135" .115" 2.260" 2.240" 2x Ø.180" .165" .354" .334" SDA380 1.490" 1.470" High Reliability Screening Available, See Page 26 Jump to Table of Contents Contact your local SSDI Representative or contact the factory directly Phone- (562) 404-4474 Email- [email protected] 6 Single Phase Bridge Rectifiers IO 0.3 Amps to 100 Amps* PIV 50 Volts to 5,000 Volts* trr 30 nsec to 5 µsec* * Higher voltages, higher currents & faster trr available, please contact SSDI authorized representative or factory. 7 Data sheets available at www.ssdi-power.com Jump to Table of Contents Single Phase Bridge Rectifiers High Reliability Screening Available, See Page 26 Single Phase Bridges - Ratings Based on 25 °C Case Temperature Sorted by trr then by IF(AV) Part Number All Devices Screened to: Maximum Reverse Recovery Time TX, TXV, or S-Level Average DC Output Current Peak Inverse Voltage Maximum Forward Voltage Drop (per leg) (per leg) Maximum Leakage Non-Repetitive Sinusoidal Package Data Sheet Current Surge (@ PIV) (8.3msec) Types Number IR Izsm trr IF(AV) PIV nsec Amps Volts Volts Amps µA Amps SDA356BHF 30 1 100 1 1 5 25 SDA276 RA0056 SDA356DHF 30 1 200 1 1 5 25 SDA276 RA0056 SDA165DHF 35 5 200 1.05 3 10 50 SDA165 RA0008 SDA165EHF 35 6 300 1.05 3 10 50 SDA165 RA0008 SDA165FHF 35 6 400 1.85 3 10 75 SDA165 RA0008 SDA165GHF 35 6 600 1.85 3 10 75 SDA165 RA0008 SDA165HHF 35 6 800 2.3 3 10 75 SDA165 RA0008 SDA165AHF 35 10 50 0.95 6 5 125 SDA165 RA0008 SDA165BHF 35 10 100 0.95 6 5 125 SDA165 RA0008 SDA165CHF 35 10 150 0.95 6 5 125 SDA165 RA0008 SDA42AHF 40 14.5 50 1.35 3 10 75 SDA130 RA0059 SDA42BHF 40 14.5 100 1.35 3 10 75 SDA130 RA0059 SDA42CHF 40 14.5 200 1.35 3 10 75 SDA130 RA0059 SDA42DHF 40 14.5 300 1.35 3 10 75 SDA130 RA0059 SDA42EHF 40 14.5 400 1.35 3 10 75 SDA130 RA0059 SDA42FHF 40 14.5 500 1.35 3 10 75 SDA130 RA0059 SDA42GHF 40 14.5 600 1.35 3 10 75 SDA130 RA0059 SDA628A 40 18 50 0.95 6 20 150 SDA267 RA0053 SDA628B 40 18 100 0.95 6 20 150 SDA267 RA0053 SDA628C 40 18 150 0.95 6 20 150 SDA267 RA0053 SDA628E 40 18 250 0.95 6 20 150 SDA267 RA0053 SDA628F 40 18 300 0.95 6 20 150 SDA267 RA0053 SDA803A 50 20 50 0.95 6 5 125 SDA267 RA0040 SDA803B 50 20 100 0.95 6 5 125 SDA267 RA0040 SDA803C 50 20 200 0.95 6 5 125 SDA267 RA0040 SDA803D 50 20 300 0.95 6 5 125 SDA267 RA0040 SDA18A 50 35 200 1.3 10 20 300 SDA130 RA0060 SDA18B 50 35 300 1.3 10 20 300 SDA130 RA0060 SDA18C 50 35 400 1.3 10 20 300 SDA130 RA0060 SDA18D 50 35 500 1.3 10 20 300 SDA130 RA0060 SDA18E 50 35 600 1.3 10 20 300 SDA130 RA0060 SDA18F 50 35 700 1.3 10 20 300 SDA130 RA0060 SDA18G 50 35 800 1.3 10 20 300 SDA130 RA0060 SDA356GUF 60 1 400 1.5 1 5 25 SDA276 RA0056 SDA356JUF 60 1 600 1.5 1 5 25 SDA276 RA0056 (MIL-PRF-19500) VF @ IF Data sheets available at www.ssdi-power.com Jump to Table of Contents 8 Single Phase Bridge Rectifiers High Reliability Screening Available, See Page 26 Sorted by trr then by IF(AV) Part Number All Devices Screened to: TX, TXV, or S-Level (MIL-PRF-19500) Single Phase Bridges - Ratings Based on 25 °C Case Temperature Maximum Reverse Recovery Time Average DC Output Current Peak Inverse Voltage Maximum Forward Voltage Drop (per leg) (per leg) trr IF(AV) PIV nsec Amps Volts VF @ IF Volts Amps Maximum Leakage Non-Repetitive Sinusoidal Package Data Sheet Current Surge (@ PIV) (8.3msec) Types Number IR Izsm µA Amps SDA356KUF 60 1 800 1.5 1 5 25 SDA276 RA0056 SDA165DUF 60 10 400 1.2 3 10 75 SDA165 RH0237 SDA165EUF 60 10 600 1.2 3 10 75 SDA165 RH0237 SDA356MUF 70 1 1000 1.9 1 5 25 SDA276 RA0056 SDA356NUF 70 1 1200 1.9 1 5 25 SDA276 RA0056 SDA165FUF 70 10 800 1.4 3 10 75 SDA165 RH0237 SDA165GUF 70 10 1000 1.4 3 10 75 SDA165 RH0237 SDA25-3UF 70 10 3000 6 3 5 75 SDA25 RA0004 SDA41AUF 70 14.5 50 1.35 3 20 75 SDA130 RA0058 SDA41BUF 70 14.5 100 1.35 3 20 75 SDA130 RA0058 SDA41CUF 70 14.5 200 1.35 3 20 75 SDA130 RA0058 SDA41DUF 70 14.5 300 1.35 3 20 75 SDA130 RA0058 SDA41EUF 70 14.5 400 1.35 3 20 75 SDA130 RA0058 SDA41FUF 70 14.5 500 1.35 3 20 75 SDA130 RA0058 SDA41GUF 70 14.5 600 1.35 3 20 75 SDA130 RA0058 SDA356BF 100 1 100 1.1 1 5 25 SDA276 RA0056 SDA356DF 100 1 200 1.1 1 5 25 SDA276 RA0056 SDA356GF 100 1 400 1.1 1 5 25 SDA276 RA0056 SDA356JF 100 1 600 1.1 1 5 25 SDA276 RA0056 SDA356KF 100 1 800 1.1 1 5 25 SDA276 RA0056 SDA356MF 100 1 1000 1.3 1 5 25 SDA276 RA0056 SDA356NF 100 1 1200 1.3 1 5 25 SDA276 RA0056 SDA276AF 150 3 50 1.3 3 2 30 SDA276 RA0032 SDA276BF 150 3 100 1.3 3 2 30 SDA276 RA0032 SDA276CF 150 3 200 1.3 3 2 30 SDA276 RA0032 SDA276DF 150 3 400 1.3 3 2 30 SDA276 RA0032 SDA276EF 150 3 600 1.3 3 2 30 SDA276 RA0032 SDA276FF 150 3 800 1.3 3 2 30 SDA276 RA0032 SDA276GF 150 3 1000 1.3 3 2 30 SDA276 RA0032 SDA267A 150 10 50 1.2 --- 2 125 SDA267 RA0077 SDA267B 150 10 100 1.2 --- 2 125 SDA267 RA0077 SDA267C 150 10 200 1.2 --- 2 125 SDA267 RA0077 SDA267D 150 10 400 1.2 --- 2 125 SDA267 RA0077 SDA267E 150 10 600 1.2 --- 2 125 SDA267 RA0077 SDA267F 150 10 800 1.2 --- 2 125 SDA267 RA0077 9 Data sheets available at www.ssdi-power.com Jump to Table of Contents Single Phase Bridge Rectifiers High Reliability Screening Available, See Page 26 Sorted by trr then by IF(AV) Part Number All Devices Screened to: Single Phase Bridges - Ratings Based on 25 °C Case Temperature Maximum Reverse Recovery Time TX, TXV, or S-Level (MIL-PRF-19500) Average DC Output Current Peak Inverse Voltage Maximum Forward Voltage Drop (per leg) (per leg) trr IF(AV) PIV nsec Amps Volts VF @ IF Volts Amps Maximum Leakage Non-Repetitive Sinusoidal Package Data Sheet Current Surge (@ PIV) (8.3msec) Types Number IR Izsm µA Amps SDA267G 150 10 1000 1.2 --- 2 125 SDA267 RA0077 SDA263AF-1 200 75 50 1.2 10 5 375 SDA263-1 RA0079 SDA263BF-1 200 75 100 1.2 10 5 375 SDA263-1 RA0079 SDA263CF-1 200 75 200 1.2 10 5 375 SDA263-1 RA0079 SDA263DF-1 200 75 400 1.2 10 5 375 SDA263-1 RA0079 SDA263EF-1 200 75 600 1.2 10 5 375 SDA263-1 RA0079 SDA263FF-1 200 75 800 1.2 10 5 375 SDA263-1 RA0079 SDA263GF-1 200 75 1000 1.2 10 5 375 SDA263-1 RA0079 SDA676-50 500 0.3 5000 11 0.15 3 20 SDA676 RA0076 SDA676-48 500 0.325 4800 11 0.15 3 20 SDA676 RA0076 SDA676-42 500 0.375 4200 9.9 0.15 3 20 SDA676 RA0076 SDA676-36 500 0.425 3600 8.8 0.15 3 20 SDA676 RA0076 SDA676-30 500 0.625 3000 7.7 0.2 3 20 SDA676 RA0076 SDA676-24 500 0.8 2400 5.5 0.2 3 20 SDA676 RA0076 SDA676-18 500 0.85 1800 4.4 0.2 3 20 SDA676 RA0076 SDA676-12 500 1 1200 3.3 0.3 3 10 SDA676 RA0076 SDA276AM 1000 3 50 1.2 3 2 30 SDA276 RA0034 SDA276BM 1000 3 100 1.2 3 2 30 SDA276 RA0034 SDA276CM 1000 3 200 1.2 3 2 30 SDA276 RA0034 SDA276DM 1000 3 400 1.2 3 2 30 SDA276 RA0034 SDA276EM 1000 3 600 1.2 3 2 30 SDA276 RA0034 SDA276FM 1000 3 800 1.2 3 2 30 SDA276 RA0034 SDA276GM 1000 3 1000 1.2 3 2 30 SDA276 RA0034 SDA117A 5000 4 50 1.2 3 2 50 SDA117 RA0074 SDA117B 5000 4 100 1.2 3 2 50 SDA117 RA0074 SDA117C 5000 4 200 1.2 3 2 50 SDA117 RA0074 SDA117D 5000 4 400 1.2 3 2 50 SDA117 RA0074 SDA117E 5000 4 600 1.2 3 2 50 SDA117 RA0074 SDA117F 5000 4 800 1.2 3 2 50 SDA117 RA0074 SDA117G 5000 4 1000 1.2 3 2 50 SDA117 RA0074 SDA138A 5000 10 50 1.1 3 2 100 SDA138 RA0075 SDA165A 5000 10 50 1.1 3 5 75 SDA165 RA0009 SDA304A 5000 10 50 1.1 3 5 75 SDA304 RA0011 SDA138B 5000 10 100 1.1 3 2 100 SDA138 RA0075 SDA165B 5000 10 100 1.1 3 5 75 SDA165 RA0009 Data sheets available at www.ssdi-power.com Jump to Table of Contents 10 Single Phase Bridge Rectifiers High Reliability Screening Available, See Page 26 Sorted by trr then by IF(AV) Part Number All Devices Screened to: TX, TXV, or S-Level Single Phase Bridges - Ratings Based on 25 °C Case Temperature Maximum Reverse Recovery Time Average DC Output Current Peak Inverse Voltage Maximum Forward Voltage Drop (per leg) (per leg) Maximum Leakage Non-Repetitive Current Surge (@ PIV) (8.3msec) IR Izsm Amps Sinusoidal Package Data Sheet Types Number trr IF(AV) PIV nsec Amps Volts Volts Amps µA SDA304B 5000 10 100 1.1 3 5 75 SDA304 RA0011 SDA138C 5000 10 200 1.1 3 2 100 SDA138 RA0075 SDA165C 5000 10 200 1.1 3 5 75 SDA165 RA0009 SDA304C 5000 10 200 1.1 3 5 75 SDA304 RA0011 SDA138D 5000 10 400 1.1 3 2 100 SDA138 RA0075 SDA165D 5000 10 400 1.1 3 5 75 SDA165 RA0009 SDA304D 5000 10 400 1.1 3 5 75 SDA304 RA0011 SDA138E 5000 10 600 1.1 3 2 100 SDA138 RA0075 SDA165E 5000 10 600 1.1 3 5 75 SDA165 RA0009 SDA304E 5000 10 600 1.1 3 5 75 SDA304 RA0011 SDA138F 5000 10 800 1.1 3 2 100 SDA138 RA0075 SDA165F 5000 10 800 1.1 3 5 75 SDA165 RA0009 SDA304F 5000 10 800 1.1 3 5 75 SDA304 RA0011 SDA138G 5000 10 1000 1.1 3 2 100 SDA138 RA0075 SDA165G 5000 10 1000 1.2 3 5 70 SDA165 RA0009 SDA304G 5000 10 1000 1.1 3 5 75 SDA304 RA0011 (MIL-PRF-19500) VF @ IF SDA130A 5000 17.5 50 1 5 5 150 SDA130 RA0078 SDA130B 5000 17.5 100 1 5 5 150 SDA130 RA0078 Single Phase Bridge Rectifier Packages: SDA132 SDA263-1 SDA138 11 Data sheets available at www.ssdi-power.com Jump to Table of Contents Single Phase Bridge Rectifiers High Reliability Screening Available, See Page 26 Sorted by trr then by IF(AV) Part Number All Devices Screened to: Single Phase Bridges - Ratings Based on 25 °C Case Temperature Maximum Reverse Recovery Time TX, TXV, or S-Level Peak Inverse Voltage Average DC Output Current Maximum Forward Voltage Drop (per leg) (per leg) Maximum Leakage Non-Repetitive Sinusoidal Package Data Sheet Current Surge (@ PIV) (8.3msec) Types Number IR Izsm trr IF(AV) PIV nsec Amps Volts Volts Amps µA Amps SDA130C 5000 17.5 200 1 5 5 150 SDA130 RA0078 SDA130D 5000 17.5 400 1 5 5 150 SDA130 RA0078 SDA130E 5000 17.5 600 1 5 5 150 SDA130 RA0078 SDA130F 5000 17.5 800 1 5 5 150 SDA130 RA0078 SDA130G 5000 17.5 1000 1 5 5 150 SDA130 RA0078 SDA132A 5000 50 50 1.1 25 5 400 SDA132 RA0057 SDA132B 5000 50 100 1.1 25 5 400 SDA132 RA0057 SDA132C 5000 50 200 1.1 25 5 400 SDA132 RA0057 SDA132D 5000 50 400 1.1 25 5 400 SDA132 RA0057 SDA132F 5000 50 800 1.1 25 5 400 SDA132 RA0057 SDA132G 5000 50 1000 1.1 25 5 400 SDA132 RA0057 (MIL-PRF-19500) VF @ IF SDA263A-1 5000 100 50 1.2 10 5 375 SDA263-1 RA0080 SDA263B-1 5000 100 100 1.2 10 5 375 SDA263-1 RA0080 SDA263C-1 5000 100 200 1.2 10 5 375 SDA263-1 RA0080 SDA263D-1 5000 100 400 1.2 10 5 375 SDA263-1 RA0080 SDA263E-1 5000 100 600 1.2 10 5 375 SDA263-1 RA0080 SDA263F-1 5000 100 800 1.2 10 5 375 SDA263-1 RA0080 SDA263G-1 5000 100 1000 1.2 10 5 375 SDA263-1 RA0080 Single Phase Bridge Rectifier Packages: AC SDA304 AC SDA25 SDA130 SDA276 (Shown with Bent Lead Option) Data sheets available at www.ssdi-power.com Jump to Table of Contents 12 Three Phase Bridge Rectifiers IO 0.5 Amps to 100 Amps* PIV 50 Volts to 5,000 Volts* trr 40 nsec to 5 µsec* * Higher voltages, higher currents & faster trr available, please contact SSDI authorized representative or factory. 13 Data sheets available at www.ssdi-power.com Jump to Table of Contents Three Phase Bridge Rectifiers High Reliability Screening Available, See Page 26 Three Phase Bridges - Ratings Based on 25 °C Case Temperature Sorted by trr then by IF(AV) Part Number All Devices Screened to: Maximum Reverse Recovery Time TX, TXV, or S-Level Average DC Output Current Peak Inverse Voltage Maximum Forward Voltage Drop (per leg) (per leg) Maximum Leakage Non-Repetitive Sinusoidal Package Data Sheet Current Surge (@ PIV) (8.3msec) Types Number IR Izsm trr IF(AV) PIV nsec Amps Volts Volts Amps µA Amps SDA38AHF 40 10 100 1.35 3 10 75 SDA312 RA0030 SDA38BHF 40 10 200 1.35 3 10 75 SDA312 RA0030 SDA38CHF 40 10 300 1.35 3 10 75 SDA312 RA0030 SDA38DHF 40 10 400 1.35 3 10 75 SDA312 RA0030 SDA38EHF 40 10 500 1.35 3 10 75 SDA312 RA0030 SDA38FHF 40 10 600 1.35 3 10 75 SDA312 RA0030 SDA36AHF 40 14 100 1.35 3 10 60 SDA167 RA0070 SDA36BHF 40 14 200 1.35 3 10 60 SDA167 RA0070 SDA36CHF 40 14 300 1.35 3 10 60 SDA167 RA0070 SDA36DHF 40 14 400 1.35 3 10 60 SDA167 RA0070 SDA36EHF 40 14 600 1.35 3 10 60 SDA167 RA0070 SDA36FHF 40 14 600 1.35 3 10 60 SDA167 RA0070 SDA160A 40 40 50 1.2 10 20 150 SDA160 RA0089 SDA160B 40 40 100 1.2 10 20 150 SDA160 SDA160 SDA160C 40 40 150 1.2 10 20 150 SDA160 SDA160 SDA160D 40 40 200 1.2 10 20 150 SDA160 SDA160 SDA160E 40 40 250 1.2 10 20 150 SDA160 SDA160 SDA160F 40 40 300 1.2 10 20 150 SDA160 SDA160 SDA167DUF 50 25 420 1.35 3 10 150 SDA167 RA0042 SDA167DUFT 50 25 420 1.35 3 10 150 SDA167 RA0042 SDA167RDUF 50 25 420 1.35 3 10 150 SDA167 RA0042 SDA167RDUFT 50 25 420 1.35 3 10 150 SDA167 RA0042 SDA167EUF 50 25 620 1.35 3 10 150 SDA167 RA0042 SDA167EUFT 50 25 620 1.35 3 10 150 SDA167 RA0042 SDA167REUF 50 25 620 1.35 3 10 150 SDA167 RA0042 SDA167REUFT 50 25 620 1.35 3 10 150 SDA167 RA0042 SDA167FUF 50 25 820 1.5 3 10 150 SDA167 RA0042 SDA167FUFT 50 25 820 1.5 3 10 150 SDA167 RA0042 SDA167RFUF 50 25 820 1.5 3 10 150 SDA167 RA0042 SDA167RFUFT 50 25 820 1.5 3 10 150 SDA167 RA0042 SDA37AUF 70 10 100 1.35 3 20 75 SDA312 RA0083 SDA37BUF 70 10 200 1.35 3 20 75 SDA312 RA0083 SDA37CUF 70 10 300 1.35 3 20 75 SDA312 RA0083 SDA37DUF 70 10 400 1.35 3 20 75 SDA312 RA0083 SDA37EUF 70 10 500 1.35 3 20 75 SDA312 RA0083 SDA37FUF 70 10 600 1.35 3 20 75 SDA312 RA0083 (MIL-PRF-19500) VF @ IF Data sheets available at www.ssdi-power.com Jump to Table of Contents 14 Three Phase Bridge Rectifiers High Reliability Screening Available, See Page 26 Sorted by trr then by IF(AV) Part Number All Devices Screened to: TX, TXV, or S-Level Three Phase Bridges - Ratings Based on 25 °C Case Temperature Maximum Reverse Recovery Time Average DC Output Current Peak Inverse Voltage Maximum Forward Voltage Drop (per leg) (per leg) Maximum Leakage Non-Repetitive Sinusoidal Package Data Sheet Current Surge (@ PIV) (8.3msec) Types Number IR Izsm trr IF(AV) PIV nsec Amps Volts Volts Amps µA Amps SDA35AUF 70 14 100 1.35 3 20 60 SDA167 RA0069 SDA35BUF 70 14 200 1.35 3 20 60 SDA167 RA0069 SDA35CUF 70 14 300 1.35 3 20 60 SDA167 RA0069 SDA35DUF 70 14 400 1.35 3 20 60 SDA167 RA0069 SDA35EUF 70 14 500 1.35 3 20 60 SDA167 RA0069 SDA35FUF 70 14 600 1.35 3 20 60 SDA167 RA0069 SPA560J 70 22 600 1.4 3 10 125 SPA560 RA0091 SPA560K 70 22 800 1.4 3 10 125 SPA560 RA0091 SPA560M 70 22 1000 1.4 3 10 125 SPA560 RA0091 SDA116J 70 25 600 1.4 3 500 125 SDA116 RA0046 SDA116K 70 25 800 1.4 3 500 125 SDA116 RA0046 SDA116M 70 25 1000 1.4 3 500 125 SDA116 RA0046 SDA167HCEUF 70 33 600 1.42 3 20 250 SDA167 RA0018 SDA167HCEUFT 70 33 600 1.42 3 20 250 SDA167 RA0018 SDA167HREUF 70 33 600 1.42 3 20 250 SDA167 RA0018 SDA167HREUFT 70 33 600 1.42 3 20 250 SDA167 RA0018 SDA167HCFUF 70 33 800 1.42 3 20 250 SDA167 RA0018 SDA167HCFUFT 70 33 800 1.42 3 20 250 SDA167 RA0018 SDA167HRFUF 70 33 800 1.42 3 20 250 SDA167 RA0018 SDA167HRFUFT 70 33 800 1.42 3 20 250 SDA167 RA0018 SDA167HCGUF 70 33 1000 1.42 3 20 250 SDA167 RA0018 SDA167HCGUFT 70 33 1000 1.42 3 20 250 SDA167 RA0018 SDA167HRGUF 70 33 1000 1.42 3 20 250 SDA167 RA0018 SDA167HRGUFT 70 33 1000 1.42 3 20 250 SDA167 RA0018 SDA403AF 150 5 50 1.4 3 3 25 SDA403 RA0082 SDA403BF 150 5 100 1.4 3 3 25 SDA403 RA0082 SDA403CF 150 5 200 1.4 3 3 25 SDA403 RA0082 SDA403DF 150 5 400 1.4 3 3 25 SDA403 RA0082 SDA403EF 150 5 600 1.4 3 3 25 SDA403 RA0082 SDA403FF 150 5 800 1.4 3 3 25 SDA403 RA0082 SDA403GF 150 5 1000 1.4 3 3 25 SDA403 RA0082 (MIL-PRF-19500) VF @ IF SDA312AF 180 10 50 1.4 3 5 75 SDA312 RC0034 SDA312BF 180 10 100 1.4 3 5 75 SDA312 RC0034 SDA312CF 180 10 200 1.4 3 5 75 SDA312 RC0034 SDA312DF 180 10 400 1.4 3 5 75 SDA312 RC0034 SDA312EF 180 10 600 1.4 3 5 75 SDA312 RC0034 15 Data sheets available at www.ssdi-power.com Jump to Table of Contents Three Phase Bridge Rectifiers High Reliability Screening Available, See Page 26 Sorted by trr then by IF(AV) Part Number All Devices Screened to: Three Phase Bridges - Ratings Based on 25 °C Case Temperature Maximum Reverse Recovery Time TX, TXV, or S-Level Average DC Output Current Peak Inverse Voltage Maximum Forward Voltage Drop (per leg) (per leg) Maximum Leakage Non-Repetitive Sinusoidal Package Data Sheet Current Surge (@ PIV) (8.3msec) Types Number IR Izsm trr IF(AV) PIV nsec Amps Volts Volts Amps µA Amps SDA312FF 200 10 800 1.4 3 5 75 SDA312 RC0034 SDA312GF 200 10 1000 1.4 3 5 75 SDA312 RC0034 SDA262EF-3 200 50 600 1.2 10 10 240 SDA263-3 RA0014 SDA262FF-3 200 50 800 1.2 10 10 240 SDA263-3 RA0014 SDA262GF-3 200 50 1000 1.2 10 10 240 SDA263-3 RA0014 (MIL-PRF-19500) VF @ IF SDA263AF-3 200 75 50 1.2 10 5 375 SDA263-3 RA0064 SDA263BF-3 200 75 100 1.2 10 5 375 SDA263-3 RA0064 SDA263CF-3 200 75 200 1.2 10 5 375 SDA263-3 RA0064 SDA263DF-3 200 75 400 1.2 10 5 375 SDA263-3 RA0064 SDA263EF-3 200 75 600 1.2 10 5u 375 SDA263-3 RA0064 SDA263FF-3 200 75 800 1.2 10 5u 375 SDA263-3 RA0064 SDA263GF-3 200 75 1000 1.2 10 5u 375 SDA263-3 RA0064 SDA667JFl 250 40 600 1.15 3 5u 250 SDA667 RA0022 SDA667JFT 250 40 600 1.15 3 5u 250 SDA667 RA0022 SDA667KFl 250 40 800 1.15 3 5u 250 SDA667 RA0022 SDA667KFT 250 40 800 1.15 3 5u 250 SDA667 RA0022 SDA667MFL 250 40 1000 1.15 3 5 250 SDA667 RA0022 SDA667MFT 250 40 1000 1.15 3 5 250 SDA667 RA0022 SDA253DF 250 50 400 1.25 18 10 300 SDA263-3 RA0049 SDA253EF 250 50 600 1.25 18 10 300 SDA263-3 RA0049 SDA253FF 250 50 800 1.25 18 10 300 SDA263-3 RA0049 SDA294H 5000 0.5 1500 1.1 0.5 1 50 SDA294 RA0081 SDA294J 5000 0.5 2000 1.1 0.5 1 50 SDA294 RA0081 SDA294K 5000 0.5 2500 1.1 0.5 1 50 SDA294 RA0081 SDA294L 5000 0.5 3000 1.1 0.5 1 50 SDA294 RA0081 SDA294A 5000 2 50 1.1 2 1 50 SDA294 RA0081 SDA294B 5000 2 100 1.1 2 1 50 SDA294 RA0081 SDA294C 5000 2 200 1.1 2 1 50 SDA294 RA0081 SDA294D 5000 2 400 1.1 2 1 50 SDA294 RA0081 SDA294E 5000 2 600 1.1 2 1 50 SDA294 RA0081 SDA294F 5000 2 800 1.1 2 1 50 SDA294 RA0081 SDA294G 5000 2 1000 1.1 2 1 50 SDA294 RA0081 SDA113A 5000 3 50 1.1 3 5 50 SDA113 RA0047 SDA113B 5000 3 100 1.1 3 5 50 SDA113 RA0047 SDA113C 5000 3 200 1.1 3 5 50 SDA113 RA0047 SDA113D 5000 3 400 1.1 3 5 50 SDA113 RA0047 Data sheets available at www.ssdi-power.com Jump to Table of Contents 16 Three Phase Bridge Rectifiers High Reliability Screening Available, See Page 26 Sorted by trr then by IF(AV) Part Number All Devices Screened to: TX, TXV, or S-Level (MIL-PRF-19500) Three Phase Bridges - Ratings Based on 25 °C Case Temperature Maximum Reverse Recovery Time Average DC Output Current Peak Inverse Voltage Maximum Forward Voltage Drop (per leg) (per leg) trr IF(AV) PIV nsec Amps Volts VF @ IF Volts Amps Maximum Leakage Non-Repetitive Current Surge (@ PIV) (8.3msec) IR Izsm µA Amps Sinusoidal Package Data Sheet Types Number SDA113E 5000 3 600 1.1 3 5 50 SDA113 RA0047 SDA113F 5000 3 800 1.1 3 5 50 SDA113 RA0047 SDA113G 5000 3 1000 1.1 3 5 50 SDA113 RA0047 SDA295A 5000 5 50 1.2 5 2 70 SDA295 RA0010 SDA316A 5000 5 50 1.2 3 3 50 SDA403 RA0036 SDA295B 5000 5 100 1.2 5 2 70 SDA295 RA0010 SDA316B 5000 5 100 1.2 3 3 50 SDA403 RA0036 SDA295C 5000 5 200 1.2 5 2 70 SDA295 RA0010 SDA316C 5000 5 200 1.2 3 3 50 SDA403 RA0036 SDA295D 5000 5 400 1.2 5 2 70 SDA295 RA0010 SDA316D 5000 5 400 1.2 3 3 50 SDA403 RA0036 SDA295E 5000 5 600 1.2 5 2 70 SDA295 RA0010 SDA316E 5000 5 600 1.2 3 3 50 SDA403 RA0036 SDA295F 5000 5 800 1.2 5 2 70 SDA295 RA0010 SDA168H 5000 5 1000 1.1 3 5 150 SDA168 RA0031 SDA295G 5000 5 1000 1.2 5 2 70 SDA295 RA0010 SDA168I 5000 5 1500 2.2 3 5 150 SDA168 RA0031 SDA168J 5000 5 2000 2.2 3 5 150 SDA168 RA0031 SDA168K 5000 5 2500 3.3 3 5 150 SDA168 RA0031 SDA168L 5000 5 3000 3.3 3 5 150 SDA168 RA0031 SDA168M 5000 5 4000 4.4 3 5 150 SDA168 RA0031 SDA168N 5000 5 5000 5.5 3 5 150 SDA168 RA0031 SDA403A 5000 6 50 1.2 3 3 30 SDA403 RA0005 SDA403B 5000 6 100 1.2 3 3 30 SDA403 RA0005 SDA403C 5000 6 200 1.2 3 3 30 SDA403 RA0005 SDA403D 5000 6 400 1.2 3 3 30 SDA403 RA0005 SDA403E 5000 6 600 1.2 3 3 30 SDA403 RA0005 SDA403F 5000 6 800 1.2 3 3 30 SDA403 RA0005 SDA403G 5000 6 1000 1.2 3 3 30 SDA403 RA0005 SDA312A 5000 10 50 1 3 5 75 SDA312 RA0001 SDA312B 5000 10 100 1 3 5 75 SDA312 RA0001 SDA312C 5000 10 200 1 3 5 75 SDA312 RA0001 SDA312D 5000 10 400 1 3 5 75 SDA312 RA0001 SDA312E 5000 10 600 1 3 5 75 SDA312 RA0001 SDA312F 5000 10 800 1 3 5 75 SDA312 RA0001 17 Data sheets available at www.ssdi-power.com Jump to Table of Contents Three Phase Bridge Rectifiers High Reliability Screening Available, See Page 26 Sorted by trr then by IF(AV) Part Number All Devices Screened to: Three Phase Bridges - Ratings Based on 25 °C Case Temperature Maximum Reverse Recovery Time TX, TXV, or S-Level Average DC Output Current Peak Inverse Voltage (per leg) trr IF(AV) PIV nsec Amps Volts SDA312G 5000 10 SDA167D 5000 25 SDA167DT 5000 SDA167E (MIL-PRF-19500) Maximum Forward Voltage Drop (per leg) VF @ IF Maximum Leakage Non-Repetitive Current Surge (@ PIV) (8.3msec) IR Izsm µA Amps Sinusoidal Package Data Sheet Types Number Volts Amps 1000 1 3 5 75 SDA312 RA0001 400 1.2 9 10 150 SDA167 RA0048 25 400 1.2 9 10 150 SDA167 RA0048 5000 25 600 1.2 9 10 150 SDA167 RA0048 SDA167ET 5000 25 600 1.2 9 10 150 SDA167 RA0048 SDA167F 5000 25 800 1.2 9 10 150 SDA167 RA0048 SDA167FT 5000 25 800 1.2 9 10 150 SDA167 RA0048 SDA167G 5000 25 1000 1.2 9 10 150 SDA167 RA0048 SDA167GT 5000 25 1000 1.2 9 10 150 SDA167 RA0048 SDA195 5000 30 100 1.05 15 25 200 SDA195 RA0043 SDA195L 5000 30 100 1.05 15 25 200 SDA195 RA0043 SDA263A-3 5000 100 50 1.2 10 5 375 SDA263-3 RA0071 SDA263B-3 5000 100 100 1.2 10 5 375 SDA263-3 RA0071 SDA263C-3 5000 100 200 1.2 10 5 375 SDA263-3 RA0071 SDA263D-3 5000 100 400 1.2 10 5 375 SDA263-3 RA0071 SDA263E-3 5000 100 600 1.2 10 5 375 SDA263-3 RA0071 SDA263F-3 5000 100 800 1.2 10 5 375 SDA263-3 RA0071 SDA263G-3 5000 100 1000 1.2 10 5 375 SDA263-3 RA0071 Three Phase Bridge Rectifier Packages: SDA294 SDA113 SDA403 SDA176 SDA312 SDA263-3 Data sheets available at www.ssdi-power.com Jump to Table of Contents 18 HV Bridges & Assemblies IO 0.5 Amps to 20 Amps* PIV 2.5 kV to 20 kV* trr 35 nsec to 5 µsec* * Higher voltages, higher currents & faster trr available, please contact SSDI authorized representative or factory. 19 Data sheets available at www.ssdi-power.com Jump to Table of Contents HV Bridges & Assemblies High Reliability Screening Available, See Page 26 Sorted by trr then by IF(AV) Part Number All Devices Screened to: HV Bridges & Assemblies- Ratings Based on 25 °C Case Temperature Maximum Reverse Recovery Time TX, TXV, or S-Level (MIL-PRF-19500) Average DC Output Current Peak Inverse Voltage Maximum Forward Voltage Drop (per leg) (per leg) trr IF(AV) PIV nsec Amps Volts VF @ IF Volts Amps Maximum Leakage Non-Repetitive Sinusoidal Package Data Sheet Current Surge (@ PIV) (8.3msec) Types Number IR Izsm µA Amps SPA548-01 35 2 2000 6 0.75 5 20 Assembly PM0022 SPA547-01 40 0.8 3000 8.2 1 1 40 Assembly PM0021 SDA345 60 1 3000 5.7 1 5 25 Assembly RA0072 SPX2091 60 1 9300 2.5 1 1 25 Assembly PM0023 SDA346 60 1 10000 14.5 1 5 25 Assembly RA0073 SPA513-02 60 1 15000 7.5 1 1 25 Assembly PM0012 SPA513-03 60 1 17500 7.5 1 1 25 Assembly PM0012 SPA513-04 60 1 20000 7.5 1 1 25 Assembly PM0012 SDAD101H15UF 70 0.95 15000 18.9 0.54 20 25 SDAD101 RA0085 SDAD101H10UF 70 1.35 10000 13 0.68 20 125 SDAD101 RA0085 SDAD102H15UF 70 1.4 15000 18.9 0.7 15 100 SDAD102 RA0087 SDAD101H7.5UF 70 1.8 7500 9.9 0.81 20 125 SDAD101 RA0085 SDAH2500UF 70 2 2500 5.5 3 3 75 SDAH HV Stick RA0003 SDAH5000UF 70 2 5000 9.5 3 3 75 SDAH HV Stick RA0003 SDAH7500UF 70 2 7500 15 3 3 75 SDAH HV Stick RA0003 SDAD102H10UF 70 2 10000 13.6 1.2 15 100 SDAD102 RA0087 SDAH10000UF 70 2 10000 19 3 3 75 SDAH HV Stick RA0003 SDAH12500UF 70 2 12500 24.5 3 3 75 SDAH HV Stick RA0003 SDAH15000UF 70 2 15000 28.5 3 3 75 SDAH HV Stick RA0003 SDAH20000UF 70 2 20000 38 3 3 75 SDAH HV Stick RA0003 SDAH25000UF 70 2 25000 47.5 3 3 75 SDAH HV Stick RA0003 SDAD101H5.0UF 70 2.34 5000 6.71 0.95 20 125 SDAD101 RA0085 SPA516L-3UF 70 3 3000 5.7 3 10 75 Assembly RA0020 SDAD102H7.5UF 70 3 7500 10.9 1.5 15 125 SDAD102 RA0087 SDAD103H15UF 70 3 15000 19.2 1.44 10 125 SDAD103 RA0084 SDA475-02 70 3 18000 10 0.6 2 25 Assembly PM0005 SDAD101H2.5UF 70 3.6 2500 3.96 1.62 20 125 SDAD101 RA0085 SDAD103H10UF 70 4.5 10000 13.85 2.25 10 125 SDAD103 RA0084 SDAD103H7.5UF 70 7.2 7500 10.1 3.6 20 200 SDAD103 RA0084 SDAD102H5.0UF 70 8.8 5000 7.92 4.5 30 200 SDAD102 RA0087 SDAD102H2.5UF 70 10.6 2500 4.35 6.3 30 200 SDAD102 RA0087 SDAD103H5.0UF 70 10.8 5000 7.6 5.4 30 200 SDAD103 RA0084 SDAD103H2.5UF 70 14.4 2500 3.9 7.2 30 200 SDAD103 RA0084 SDA2500UF 80 0.5 2500 5.5 2 2 25 SDA HV Stick RA0006 Data sheets available at www.ssdi-power.com Jump to Table of Contents 20 HV Bridges & Assemblies High Reliability Screening Available, See Page 26 Sorted by trr then by IF(AV) Part Number All Devices Screened to: TX, TXV, or S-Level (MIL-PRF-19500) HV Bridges & Assemblies- Ratings Based on 25 °C Case Temperature Maximum Reverse Recovery Time Average DC Output Current Peak Inverse Voltage Maximum Forward Voltage Drop (per leg) (per leg) trr IF(AV) PIV nsec Amps Volts Volts VF @ IF Amps Maximum Leakage Non-Repetitive Current Surge (@ PIV) (8.3msec) IR Izsm µA Amps Sinusoidal Package Data Sheet Types Number SDA5000UF 80 0.5 5000 9.5 2 2 25 SDA HV Stick RA0006 SDA7500UF 80 0.5 7500 15 2 2 25 SDA HV Stick RA0006 SDA10000UF 80 0.5 10000 19 2 2 25 SDA HV Stick RA0006 SDA12500UF 80 0.5 12500 24.5 2 2 25 SDA HV Stick RA0006 SDA15000UF 80 0.5 15000 28.5 2 2 25 SDA HV Stick RA0006 SDA20000UF 80 0.5 20000 38 2 2 25 SDA HV Stick RA0006 SDA25000UF 80 0.5 25000 47.5 2 2 25 SDA HV Stick RA0006 SPA516-2F 150 10 2000 4.4 10 10 75 Assembly RA0019 SDA2500F 180 0.5 2500 4.5 2 2 25 SDA HV Stick RA0007 SDA5000F 180 0.5 5000 7.5 2 2 25 SDA HV Stick RA0007 SDA7500F 180 0.5 7500 12 2 2 25 SDA HV Stick RA0007 SDA10000F 180 0.5 10000 15 2 2 25 SDA HV Stick RA0007 SDA12500F 180 0.5 12500 19.5 2 2 25 SDA HV Stick RA0007 SDA15000F 180 0.5 15000 22.5 2 2 25 SDA HV Stick RA0007 SDA20000F 180 0.5 20000 30 2 2 25 SDA HV Stick RA0007 SDA25000F 180 0.5 25000 37.5 2 2 25 SDA HV Stick RA0007 SDAD101S10F 500 0.58 10000 23 0.3 5 20 SDAD101 RA0041 SDAD102C15F 500 0.7 15000 30 0.25 2 25 SDAD102 RA0086 SDAD101S7.5F 500 0.75 7500 18 0.4 5 20 SDAD101 RA0041 SDAD101S5.0F 500 0.9 5000 12 0.5 5 20 SDAD101 RA0041 SDAD101B7.5F 500 1 7500 18 0.4 10 70 SDAD101 RA0041 SDAD102C10F 500 1 10000 20 0.37 2 25 SDAD102 RA0086 SDAD101H15F 500 1.06 15000 17.2 0.5 10 30 SDAD101 RA0041 SDAD102C7.5F 500 1.25 7500 15 0.5 2 25 SDAD102 RA0086 SDAD101B5.0F 500 1.3 5000 12 0.6 10 70 SDAD101 RA0041 SDAD102H15F 500 1.4 15000 17.2 0.8 10 100 SDAD102 RA0086 SDAD102D7.5F 500 1.5 7500 17 0.5 5 80 SDAD102 RA0086 SDAD101H10F 500 1.5 10000 11.8 0.8 10 150 SDAD101 RA0041 SDAD103C15F 500 1.67 15000 27 0.65 5 30 SDAD103 RA0065 SDAD102C5.0F 500 1.7 5000 10 0.7 2 25 SDAD102 RA0086 SDAD101B2.5F 500 2 2500 6 0.9 10 70 SDAD101 RA0041 SDAD102D5.0F 500 2 5000 11 0.75 5 80 SDAD102 RA0086 SDAD101H7.5F 500 2 7500 9 0.9 10 150 SDAD101 RA0041 SDAD102H10F 500 2 10000 12 1.3 10 100 SDAD102 RA0086 SDAD103D10F 500 2.5 10000 22 0.85 5 80 SDAD103 RA0065 21 Data sheets available at www.ssdi-power.com Jump to Table of Contents HV Bridges & Assemblies High Reliability Screening Available, See Page 26 Sorted by trr then by IF(AV) Part Number All Devices Screened to: HV Bridges & Assemblies- Ratings Based on 25 °C Case Temperature Maximum Reverse Recovery Time TX, TXV, or S-Level (MIL-PRF-19500) Average DC Output Current Peak Inverse Voltage Maximum Forward Voltage Drop (per leg) (per leg) trr IF(AV) PIV nsec Amps Volts VF @ IF Volts Amps Maximum Leakage Non-Repetitive Sinusoidal Package Data Sheet Current Surge (@ PIV) (8.3msec) Types Number IR Izsm µA Amps SDAD101H5.0F 500 2.6 5000 6.1 1.1 10 150 SDAD101 RA0041 SDAD102H7.5F 500 3 7500 9.6 1.7 10 125 SDAD102 RA0086 SDAD102D2.5F 500 3.3 2500 6 1.2 5 80 SDAD102 RA0086 SDAD103H15F 500 3.33 15000 17.2 1.6 10 125 SDAD103 RA0065 SDAD103D7.5F 500 3.5 7500 17 1.1 5 80 SDAD103 RA0065 SDAD101H2.5F 500 4 2500 3.6 1.8 10 150 SDAD101 RA0041 SDAD103F7.5F 500 4 7500 17 1.2 10 150 SDAD103 RA0065 SDAD102F5.0F 500 4.4 5000 11 1.6 10 150 SDAD102 RA0086 SDAD103D5.0F 500 4.8 5000 11 1.6 5 80 SDAD103 RA0065 SDAD103H10F 500 5 10000 12 2.5 10 125 SDAD103 RA0065 SDAD102F2.5F 500 5.3 2500 6 2.2 10 150 SDAD102 RA0086 SDAD103F5.0F 500 6 5000 11 1.8 10 150 SDAD103 RA0065 SDAD103F2.5F 500 8 2500 6 2.5 10 150 SDAD103 RA0065 SDAD103H7.5F 500 8 7500 8.65 4 20 200 SDAD103 RA0065 SDAD102H5.0F 500 8.8 5000 7.2 5 20 200 SDAD102 RA0086 SDAD102H2.5F 500 10.6 2500 4.05 7 20 200 SDAD102 RA0086 SDAD103H5.0F 500 12 5000 6.8 6.2 30 200 SDAD103 RA0065 SDAD103H2.5F 500 16 2500 3.3 8 30 200 SDAD103 RA0065 SDA5000 5000 0.5 5000 5 0.5 1 50 SDA HV Stick RC0079 SDA7500 5000 0.5 7500 7.5 0.5 1 50 SDA HV Stick RC0079 SDA10000 5000 0.5 10000 10 0.5 1 50 SDA HV Stick RC0079 SDA12500 5000 0.5 12500 12.5 0.5 1 50 SDA HV Stick RC0079 SDA15000 5000 0.5 15000 15 0.5 1 50 SDA HV Stick RC0079 SDA20000 5000 0.5 20000 20 0.5 1 50 SDA HV Stick RC0079 SDA25000 5000 0.5 25000 25 0.5 1 50 SDA HV Stick RC0079 SDAD101S15 5000 0.51 15000 25 0.2 5 25 SDAD101 RA0068 SDAD101S10 5000 0.71 10000 17 0.3 5 25 SDAD101 RA0068 SDAD102A15 5000 0.9 15000 25 0.33 2 30 SDAD102 RA0067 SDAD101S7.5 5000 0.91 7500 13 0.5 5 25 SDAD101 RA0068 SDAD101B10 5000 1 10000 17 0.4 10 80 SDAD101 RA0068 SDAD101H15 5000 1 15000 15.7 0.5 10 30 SDAD101 RA0068 SDAD101S5.0 5000 1.1 5000 9 0.6 5 25 SDAD101 RA0068 SDAD101B7.5 5000 1.2 7500 13 0.7 10 80 SDAD101 RA0068 SDAD102A10 5000 1.4 10000 16 0.5 2 30 SDAD102 RA0067 SDAD101B5.0 5000 1.5 5000 9 0.7 10 80 SDAD101 RA0068 Data sheets available at www.ssdi-power.com Jump to Table of Contents 22 HV Bridges & Assemblies High Reliability Screening Available, See Page 26 Sorted by trr then by IF(AV) Part Number All Devices Screened to: TX, TXV, or S-Level HV Bridges & Assemblies- Ratings Based on 25 °C Case Temperature Maximum Reverse Recovery Time Average DC Output Current Peak Inverse Voltage (per leg) trr IF(AV) PIV nsec Amps Volts SDAD102A7.5 5000 1.75 SDAD102H15 5000 1.8 SDAH2500 5000 2 SDAH5000 5000 SDAD102B7.5 5000 (MIL-PRF-19500) Maximum Forward Voltage Maximum Leakage Drop (per leg) VF @ IF Non-Repetitive Sinusoidal Package Data Sheet Current Surge (@ PIV) (8.3msec) Types Number IR Izsm µA Amps Volts Amps 7500 12 0.6 2 30 SDAD102 RA0067 15000 17.6 1.1 10 100 SDAD102 RA0067 2500 3 1 1 150 SDAH HV Stick RA0028 2 5000 6 1 1 150 SDAH HV Stick RA0028 2 7500 12 0.7 5 100 SDAD102 RA0067 SDAH7500 5000 2 7500 8 1 1 150 SDAH HV Stick RA0028 SDAD101H10 5000 2 10000 10.7 0.8 10 150 SDAD101 RA0068 SDAH10000 5000 2 10000 11 1 1 150 SDAH HV Stick RA0028 SDAH12500 5000 2 12500 13.5 1 1 150 SDAH HV Stick RA0028 SDAH15000 5000 2 15000 16 1 1 150 SDAH HV Stick RA0028 SDAD103A15 5000 2.07 15000 25 0.72 2 30 SDAD103 RA0066 SDAD102A5.0 5000 2.2 5000 8 0.82 2 30 SDAD102 RA0067 SDAD101B2.5 5000 2.3 2500 5 1.1 10 80 SDAD101 RA0068 SDAD101H7.5 5000 2.4 7500 8.2 1 10 150 SDAD101 RA0068 SDAD102B5.0 5000 2.75 5000 8 1 5 100 SDAD102 RA0067 SDAD102H10 5000 2.8 10000 12.1 1.8 10 100 SDAD102 RA0067 SDAD101H5.0 5000 3 5000 5.5 1.3 10 150 SDAD101 RA0068 SDAD103B10 5000 3.5 10000 17 1.1 5 100 SDAD103 RA0066 SDAD102H7.5 5000 4 7500 8.85 2 10 125 SDAD102 RA0067 SDAD103H15 5000 4.14 15000 16.8 2.8 10 125 SDAD103 RA0066 SDAD102B2.5 5000 4.25 2500 4 1.5 5 100 SDAD102 RA0067 SDAD101H2.5 5000 4.6 2500 3.3 2.2 10 150 SDAD101 RA0068 SDAD103B7.5 5000 4.8 7500 13 1.5 5 100 SDAD103 RA0066 SDAD103B7.5 5000 5 7500 13 1.6 10 200 SDAD103 RA0066 SDAD102E5.0 5000 5.5 5000 10 2.2 10 200 SDAD102 RA0067 SDAD102H5.0 5000 5.5 5000 6.8 3.5 20 250 SDAD102 RA0067 SDAD103B5.0 5000 6.6 5000 9 2.2 5 100 SDAD103 RA0066 SDAD103H10 5000 7 10000 12.1 3.5 10 150 SDAD103 RA0066 SDAD103E5.0 5000 7.5 5000 10 2.5 15 200 SDAD103 RA0066 SDAD102E2.5 5000 7.7 2500 5 3 10 200 SDAD102 RA0067 SDAD103E2.5 5000 10 2500 5 3.3 10 200 SDAD103 RA0066 SDAD103H7.5 5000 10 7500 8.45 5 20 250 SDAD103 RA0066 SDAD102H2.5 5000 14.4 2500 3.4 10 20 250 SDAD102 RA0067 SDAD103H5.0 5000 15 5000 6.2 8 30 300 SDAD103 RA0066 SDAD103H2.5 5000 20 2500 3.1 10 30 300 SDAD103 RA0066 23 Data sheets available at www.ssdi-power.com Jump to Table of Contents HV Bridges & Assemblies SDAD101 Outline: .230”- .235” .020”- .040” .97”- 1.00” CATHODE 10-32 THRD. 10-32 THRD. .980”- 1.10” SDAD102 Outline: .320”- .330” Ø1.900” MAX .670” Ø .570” .300” .220” .78” MAX CATHODE Ø.250-28 UNF-2A Ø.250-28 UNF-2B .35±.05 DEEP SDAD103 Outline*: Ø 3.030" 2.970" Ø3.490" MAX .316" MAX 1.020" MAX .375-24 UNF-2B x .320" MIN Ø1.030" MAX .375-24 UNF-2A Ø1.000" MAX * See Pages 27 and 28 for Data Sheets, Data sheets available at www.ssdi-power.com Jump to Table of Contents 24 Three Phase Schottky Modules High Reliability Screening Available, See Next Page. Sorted by IF(AV) then by PIV 3-Phase Schottky Modules - Ratings Based on 25 °C Case Temperature Part Number All Devices Screened to: TX, TXV, or S-Level Data Sheet Average DC Output Current Number (MIL-PRF-19500) Peak Inverse Voltage Maximum Reverse Recovery Maximum Forward Voltage Drop (per leg) Time (per leg) Maximum Leakage Non-Repetitive Sinusoidal Current Surge (@ PIV) (8.3msec) IR Izsm IF(AV) PIV Trr Amps Volts nsec Volts Amps mA Amps VF @ IF Package Types SPMR527B10 PM0014 320 100 Schottky 0.71 106 5 1000 Assembly SPMR527F10 PM0014 320 100 Schottky 0.71 106 5 1000 Assembly SPMR527M10 PM0014 320 100 Schottky 0.71 106 5 1000 Assembly SPMR527B03 PM0014 400 30 Schottky 0.46 133 7.5 1000 Assembly SPMR527F03 PM0014 400 30 Schottky 0.46 133 7.5 1000 Assembly SPMR527M03 PM0014 400 30 Schottky 0.46 133 7.5 1000 Assembly SPMR527B04 PM0014 400 45 Schottky 0.55 133 12 1000 Assembly SPMR527F04 PM0014 400 45 Schottky 0.55 133 12 1000 Assembly SPMR527M04 PM0014 400 45 Schottky 0.55 133 12 1000 Assembly Three Phase Bridge Power Module l l l l l l l l l 3-Phase High Current Schottky Bridge Rectifier No Minority Carrier Switching Loss Electrically Isolated Baseplate Hermetically Sealed Packaging Utilizes DBCu/Al2O3 for Low Loss Operation Low Weight Al-SiC Baseplate Available with Male (M), Female (F) or Blade (B) Terminals TX, TXV, and S-Level Screening Available See Data Sheet # PM0014 ASPM SPMR527 Electrical Schematic: SPMR527M03 SPMR527M04 SPMR527M10 SPMR527F03 SPMR527F04 SPMR527F10 SPMR527B03 SPMR527B04 SPMR527B10 25 Data sheets available at www.ssdi-power.com Jump to Table of Contents High Reliability Screening Solid State Devices Screening Per MIL-PRF-19500 Guidelines* TX Level TXV Level Equivalent Equivalent S Level Equivalent Lot Acceptance Temperature Cycling Internal Visual1/ Internal Visual1/ Temperature Cycling Temperature Cycling Surge Surge Surge (as specified) (as specified) (as specified) Thermal Resp. Thermal Resp. Thermal Resp. (as specified) (as specified) (as specified) Acceleration (some excluded) Serialize Interim Electrical (case mount only) Interim Electrical (case mount only) HTRB HTRB Interim Electrical Read & Record HTRB 48 hrs. 48 hrs. 48 hrs. Interim Electrical & Delta Interim Electrical & Delta Interim Electrical & Delta Burn-in Burn-in Burn-in Tran. & FET 160 hrs. Diode & SCR HTRB 96 hrs. Tran. & FET 160 hrs. Diode & SCR HTRB 96 hrs. Interim Electrical & Delta Interim Electrical & Delta Interim Electrical & Delta Hermeticity Hermeticity PIND Case Isolation Hermeticity (N/A case mount) Case Isolation (case isolated packages only) 240 hrs. (N/A case mount) (case isolated packages only) Note: 1/ X-ray in lieu of internal visual for COTS origin parts X-Ray External Visual Case Isolation (case isolated packages only) *Specific Product Types May Have Alternate Screening Flows Contact your local SSDI Representative or contact the factory directly at (562) 404-4474. Email- [email protected] 26 Jump to Table of Contents High Reliability Hermetically Sealed Rectifier Assemblies Version 1.36 - 06/24/2015 Solid State Devices, Inc. 14701 Firestone Blvd. La Mirada, CA 90638 Phone (562) 404-4474 Fax (562) 404-1773 www.ssdi-power.com [email protected] Sales Representatives: Domestic International CentraMark Technical Sales Associates TX, OK, AR, LA P.O. Box 450877 Garland, TX 75045-0877 Phone: 972-414-8188 Fax: 972-414-6788 Brazil Techso Rua Fradique Coutinho, 316 - Cj 41 Sao Paulo - SP 05416-000 Brazil (55-11) 3120 5968 [email protected] ETSI, LLC. DC, VA, MD 3 Church Circle, Suite 120 Annapolis, MD 21401 Phone: 410-974-9351 Fax: 410-974-8247 Giesting & Associates OH, Western PA, IN, MI 2854 Blue Rock Rd. Cincinnati, OH 45239 513-385-1105 [email protected] Scientific Devices - Phila, Inc. East PA, South NJ, DE 1635 Clemens Rd. Harleysville, PA 19438 215-256-8641 [email protected] SouthTech Marketing, LLC AL, FL, GA, MS, NC, Puerto Rico, SC 8213 Nantahala Dr. Raleigh, NC 27612 919-781-0444 [email protected] W. Howard Associates, Inc. CO, UT 12353 E. Easter Ave. Suite 200 Centennial, CO 80112 303-766-5755 [email protected] Entire contents copyright © 2015 Solid State Devices, Inc. All Rights Reserved. China Rironic Electronic Technology Co., Ltd Room 1206 China Development Bank Building No 2 First Gaoxin Road Xi’an City, Shaanxi Province P.R. China +86-029-68683866 [email protected] www.rironic.com Denmark / Finland / Norway / Sweden Expando Electronics AB Mörby Centrum, Plan 7 S-182 31 Danderyd, Sweden +468 54490044 France AR France 7 Rue du fosse blanc - Bat. D1 92230 Gennevilliers, France +33 (0)1 47 91 75 30 [email protected] Germany MES Manz Electronic Systeme OHG Hauptstrasse 46/1 D-74369 Löchgau, Germany +49-7143-4031-0 India Irys Electronics 261/2 Plot 4 & 5, Silver Oak Park Baner Rd, Baner Pune 411045, India 91 20 2729 1836 [email protected] Israel FMS Aerospace Ltd. 12 Kehilat Venezia Street Tel-Aviv 69400, Israel 972-3-6094977 [email protected] Italy Milano Brothers Viale Enrico Fermi 79 00146 Roma, Italy +39 3384969298 [email protected] USA Office: 1456 Newport Center Drive Deerfield Beach, FL 33442 954-420-5000 Japan Sojitz Aerospace Marunouchi Trust Tower Main 4th Floor, 8-3 Marunouchi 1-chome Chiyoda-Ku Tokyo, Japan 100-0005 +81-3-6870-7211 South Korea CBOL Corporation 19850 Plummer St. Chatsworth, CA 91311 818-721-5510 [email protected] Turkey IMCA Elektronik ve Bilisim Sanayi ve Ticaret A.S. Acibadem mah. Cecen sok. Akasya Acibadem AVM A Kule Blok no: 25 A/197 34660 Uskudar Istanbul, Turkey +90 216 504 07 87 www.imca.com.tr [email protected] United Kingdom / Ireland Johnson Group Services (JGS) The Ryder Cloisters 36, Evelyn Road Dunstable, Bedfordshire LU5 4NG United Kingdom +44 (0) 1582 603439 [email protected] Jump to Table of Contents