POWERSEM PSKD312

PSKD 312
Diode Modules
IFRMS
IFAVM
VRRM
Preliminary Data Sheet
= 2x 520 A
= 2x 310 A
= 1200-2200 V
3
2
VRSM
VRRM
Type
V
1300
1500
1700
1900
2100
2300
V
1200
1400
1600
1800
2000
2200
PSKD 312/12
PSKD 312/14
PSKD 312/16
PSKD 312/18
PSKD 312/20
PSKD 312/22
Symbol
Test Conditions
IFRMS
IFAVM
TVJ = TVJM
TC = 100°C; 180° sine
IFSM
TVJ = 45°C;
VR = 0
3
1
2
1
Maximum Ratings
Features
Direct copper bonded Al2O3 -ceramic
base plate
Planar passivated chips
Isolation voltage 3600 V~
UL registered, E 148688
●
∫i2dt
520
310
A
A
t = 10 ms (50 Hz)
t = 8.3 ms (60 Hz)
10500
11200
A
A
TVJ = TVJM
VR = 0
t = 10 ms (50 Hz)
t = 8.3 ms (60 Hz)
9200
9800
A
A
TVJ = 45°C
VR = 0
t = 10 ms (50 Hz)
t = 8.3 ms (60 Hz)
551000
527000
A 2s
A 2s
TVJ = TVJM
VR = 0
t = 10 ms (50 Hz)
t = 8.3 ms (60 Hz)
423 000
403 000
A 2s
A 2s
-40...+150
150
-40...+125
°C
°C
°C
3000
3600
V~
V~
t = 1 min
t=1s
Weight
Symbol
IRRM
Test Conditions
TVJ = TVJM; VR = VRRM
Characteristic Values
30
mA
VF
IF = 600 A; TVJ = 25°C
1.32
V
VT0
rT
For power-loss calculations only
TVJ = TVJM
0.8
0.6
V
mΩ
RthJC
per
per
per
per
0.12
0.06
0.16
0.08
K/W
K/W
K/W
K/W
RthJK
●
Applications
Supplies for DC power equipment
DC supply for PWM inverter
Field supply for DC motors
Battery DC power supplies
●
●
●
Advantages
Space and weight savings
Simple mounting
Improved temperature and power
cycling
Reduced protection circuits
●
●
●
50/60 Hz, RMS
IISOL ≤ 1 mA
Mounting torque (M6)
Terminal connection torque (M8)
Typical including screws
Md
●
●
TVJ
TVJM
Tstg
VISOL
●
diode; DC current
module
diode; DC current
module
4.5-7/40-62 Nm/lb.in.
11-13/97-115 Nm/lb.in.
750
g
QS
IRM
TVJ = 125°C; IF = 400 A; -di/dt = 50 A/µs
700
260
µC
A
dS
dA
a
Creeping distance on surface
Creepage distance in air
Maximum allowable acceleration
12.7
9.6
50
mm
mm
m/s 2
●
Dimensions in mm (1 mm = 0.0394")
M8x20
Data according to IEC 60747 and refer to a single thyristor/diode unless otherwise stated.
 2003 POWERSEM reserves the right to change limits, test conditions and dimensions
POWERSEM GmbH, Walpersdorfer Str. 53
D - 91126 Schwabach
Phone: 09122 - 9764 - 0 FAX: 09122 - 9764 - 20
106
10000
IFSM
VR = 0V
2
It
A
IFAVM
50 Hz
80 % VRRM
TVJ = 45°C
TVJ = 150°C
8000
A2s
550
A
500
DC
180° sin
120°
60°
30°
450
400
350
6000
TVJ = 45°C
300
250
TVJ = 150°C
4000
200
150
2000
100
50
0
0.001
10
5
0.01
s
0.1
1
1
ms
t
t
Fig. 1 Surge overload current
IFSM: Crest value, t: duration
Fig. 2 I2t versus time (1-10 ms)
400
300
25
50
75
100
125 °C 150
Fig. 4 Power dissipation versus
forward current and ambient
temperature (per diode)
0.06
0.1
0.2
0.3
0.4
0.6
0.8
500
0
Fig. 3 Maximum forward current
at case temperature
RthKA K/W
W
0
TC
600
Ptot
10
DC
180° sin
120°
60°
30°
200
100
0
0
100
200
300
400
500 A 0
25
50
75
100
IFAVM
1750
Ptot
W
125
°C
TA
150
Fig. 5 Single phase rectifier bridge:
Power dissipation versus direct
output current and ambient
temperature
R = resistive load
L = inductive load
RthKA K/W
0.04
0.06
0.08
0.12
0.2
0.3
0.5
1500
R
L
1250
1000
750
Circuit
Circuit
B2U
B2U
2 x PSKD 312
2 x MDD312
500
250
0
0
100
200
300
400
500
600 A 0
IdAVM
25
50
75
100
°C
125
150
TA
 2003 POWERSEM reserves the right to change limits, test conditions and dimensions
POWERSEM GmbH, Walpersdorfer Str. 53
D - 91126 Schwabach
Phone: 09122 - 9764 - 0 FAX: 09122 - 9764 - 20
3000
Fig. 6 Three phase rectifier bridge:
Power dissipation versus direct
output current and ambient
temperature
RthKA K/W
W
0.03
0.06
0.1
0.15
0.2
0.3
0.4
2500
Ptot
2000
1500
Circuit
Circuit
B6U
B6U
33 xx PSKD
MDD312
312
1000
500
0
0
200
400
600
800 A
IdAVM
0
25
50
75
100
125 °C 150
TA
0.20
Fig. 7 Transient thermal impedance
junction to case (per diode)
K/W
RthJC for various conduction angles d:
0.15
ZthJC
0.10
30°
60°
120°
180°
DC
0.05
d
RthJC (K/W)
DC
180°C
120°C
60°C
30°C
0.120
0.128
0.135
0.153
0.185
Constants for ZthJC calculation:
i
0.00
10-3
10-2
10-1
100
101
s
102
t
1
2
3
4
ti (s)
0.0058
0.031
0.072
0.0112
0.00054
0.098
0.54
12
Fig. 9 Transient thermal impedance
junction to heatsink (per diode)
0.25
K/W
0.20
RthJK for various conduction angles d:
ZthJK
0.15
0.10
30°
60°
120°
180°
DC
0.05
d
RthJK (K/W)
DC
180°C
120°C
60°C
30°C
0.160
0.168
0.175
0.193
0.225
Constants for ZthJK calculation:
i
0.00
10-3
Rthi (K/W)
10-2
10-1
100
s
101
t
102
1
2
3
4
5
Rthi (K/W)
ti (s)
0.0058
0.031
0.072
0.0112
0.04
0.00054
0.098
0.54
12
12
POWERSEM GmbH, Walpersdorfer Str. 53
 2003 POWERSEM reserves the right to change limits, test conditions and dimensions
D - 91126 Schwabach
Phone: 09122 - 9764 - 0 FAX: 09122 - 9764 - 20