PCSP Series - Power Dynamics, Inc.

PCSP Series
CHASSIS MOUNT EMI/RFI LINE FILTER
MECHANICAL DIMENSIONS (Unit: mm)
4.7+0.1
-
L
53.5+0.1
-
L'
G
N
10.0
FEATURES
48 Max
The PCSP series offers filters with compact designed chassis
mount filter with current rating up to 10A, 250VAC. These
filters offer common mode and differential mode attenuation
over the frequency range of 100KHz to 50MHz.
APPLICATIONS
44 Max
Computer & networking equipment, Measuring & control
equipment, Data processing equipment, laboratory instruments,
Switching power supplies, other electronic equipment.
TECHNICAL DATA
• Rated Voltage: 115/250VAC
• Rated Current: 1A, 3A, 6A, 10A
• Power Line Frequency: 50/60Hz
• Max. Leakage Current each
Line to Ground:
@ 115VAC 60Hz: <0.8mA
@ 250VAC 50Hz: <0.8mA
• Hipot Rating (one minute)
Line to Ground: 2250VDC
Line to Line: 1450VDC
• Temperature Range: -25C to +85C
N'
18 Max
64 Max
Specifications subject to change without notice. Dimensions (mm).
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: [email protected] • www.powerdynamics.com
27
PCSP Series Ordering Code
PDI P/N
Current Rating
Capacitor C(x)
Capacitor C(y)
Induactance (L)
PCSP-01
1A
0.1µF
3300pF
3.7mH
PCSP-03
3A
0.1µF
3300pF
1.8mH
PCSP-06
6A
0.1µF
3300pF
0.7mH
PCSP-10
10A
0.1µF
3300pF
0.3mH
PCSP Series Attenuation Tables
Non-Medical Applications
Insertion loss in dB (50 Ohm circuit)
Current
Rating
Comm. Mode(L-G) MHz
.01 .15 .5 1 5 10 30
Diff. mode(L-L) MHz
.01 .15 .5 1 5 10 30
1A
39 43 52 48 42 45 30
18 19 30 41 48 50 38
3A
39 44 46 49 50 53 40
17 18 29 32 54 54 50
6A
19 23 30 33 48 57 43
12 16 27 31 49 58 45
10A
18 19 24 29 46 52 52
12 16 25 29 56 71 51
SCHEMATIC
L mH
G
L'
LOAD
LINE
L
Cy
x2
Cx
N
N'
L mH
28
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: [email protected] • www.powerdynamics.com