PE3P4W Series 3 PHASE, 4 WIRE CHASSIS MOUNT EMI/RFI LINE FILTER. MECHANICAL DIMENSIONS (Unit: mm) G2A 143.0 112.0 84.0 100.0 90.6 M6 TYP. 2x 5.0 2x R5x 10 54.0 77.0 34.0 14.0 FEATURES The PE3P4W series filters have been designed for heavy-duty machinery that requires noise control. The filters offer good noise attenuation in both forward and reverse directions for common mode and differential mode. These filters are designed with high reliability for industrial equipment. This series offers filters up to 250A at 250VAC/500VAC with suppression from 150KHz to 30MHz. G3A 201.0 170.0 126.4 184.0 92.0 164.0 M6 TYP. APPLICATIONS 2x 10 Heavy Industry equipment, Measuring & control equipment, Power supplies, other electronic/electrical equipment. 2x 10x14 65.0 140.0 35.0 C5 347 300 2x 10.5x13.5 2x 11 M12 TYP. 44 180 44 44 (379.8) 300 200 100 30 60 Specifications subject to change without notice. Dimensions (mm). 145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076 e-mail: [email protected] • www.powerdynamics.com 55 PE3P4W Series SCHEMATIC 1; CASE G2A TECHNICAL DATA L1 • Rated Voltage: 500VAC • Rated Current: 10A, 20A • Power Line Frequency: 50/60Hz • Max. Leakage Current each Line to Ground: @ 500VAC, 60Hz: 1mA (10A) @ 500VAC, 60Hz: 4mA (20A) • Hipot Rating (one minute) Line to Ground: 2250VDC • Temperature Range: -25C to +50C L'1 L L O A D L I N E L'2 L2 L L3 L'3 L Cx Cx Cx N N' Cy E Non-Medical Applications Insertion loss in dB (50 Ohm circuit) PDI P/N Current Rating (A) PE3P4W-10PS-1-G2A PE3P4W-20PS-1-G2A 10 20 Cx (uF) Cy (pF) L (mH x 2) .15 0.1 4700 22000 0.2 0.12 12 12 Comm. Mode (L-G) in MHz .5 1 5 10 30 22 22 22 27 22 27 32 32 Diff. Mode (L-L) in MHz .5 1 5 10 .15 27 32 12 12 16 17 22 22 37 22 42 27 30 27 22 SCHEMATIC 2; CASE G3A TECHNICAL DATA L'1 L1 R C1 L1 C2 L'2 L2 R C1 L1 C2 L'3 L3 R C1 L O A D L I N E • Rated Voltage: 500VAC • Rated Current: 20A, 30A, 60A • Power Line Frequency: 50/60Hz • Max. Leakage Current each Line to Ground: @ 500VAC, 60Hz: 7.5mA • Hipot Rating (one minute) Line to Ground: 2250VDC • Temperature Range: -25C to +50C C2 L1 N L'4 Cy Cy Cy Cy Cy E Cy Cy Cy Lg Non-Medical Applications Insertion loss in dB (50 Ohm circuit) PDI P/N PE3P4W-20PS-2-G3A PE3P4W-30PS-2-G3A PE3P4W-60PS-2-G3A 56 Current Rating (A) Cx1 (uF) Cx2 (uF) Cy (pF) 20 30 60 2 1 4700 L R (mH x 2) (Ohms) 3.2 1.6 0.32 110K Comm. Mode (L-G) in MHz .15 .5 1 5 10 30 .15 39 55 30 55 22 50 50 43 27 56 55 50 65 61 54 65 63 54 54 60 47 Diff. Mode (L-L) in MHz .5 1 5 10 30 65 65 60 65 66 64 65 65 64 60 58 56 52 49 50 145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076 e-mail: [email protected] • www.powerdynamics.com PE3P4W Series SCHEMATIC 3; CASE C5 TECHNICAL DATA L'1 L1 R C1 L1 L2 C 2 L1 L2 L'2 L2 C1 O I R L L C2 A N E L'3 L3 R C1 L1 D • Rated Voltage: 500VAC • Rated Current: 60A, 80A, 100A, 150A, 200A, 250A • Power Line Frequency: 50/60Hz • Max. Leakage Current each Line to Ground: @ 500VAC, 60Hz: 2.6mA (60A, 80A) @ 500VAC, 60Hz: 7.5mA (100A) @ 500VAC, 60Hz: 8.0mA (150A, 200A, 250A) • Hipot Rating (one minute) Line to Ground: 2250VDC • Temperature Range: -25C to +50C C2 L2 N L'4 Cy Cy Cy Cy E Non-Medical Applications Insertion loss in dB (50 Ohm circuit) PDI P/N Current Rating (A) PE3P4W-60PS-3-C5 PE3P4W-80PS-3-C5 PE3P4W-100PS-3-C5 PE3P4W-150PS-3-C5 PE3P4W-200PS-3-C5 PE3P4W-250PS-3-C5 60 80 100 150 200 250 R (Ohms) 430K Cx1,2 (uF) Cy (pF) L (mH x 2) 1.00 2.20 2.20 3.30 3.30 3.30 3300 3300 4700 10000 10000 10000 0.8 0.4 0.1 0.06 0.02 0.015 Comm. Mode (L-G) in MHz .15 .5 1 5 10 30 .15 38 42 37 35 32 30 32 45 43 32 28 27 78 75 81 85 82 83 42 48 53 56 53 57 54 53 59 63 61 60 56 49 53 54 58 63 47 56 52 48 51 49 145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076 e-mail: [email protected] • www.powerdynamics.com Diff. Mode (L-L) in MHz .5 1 5 10 30 73 65 75 72 78 78 63 68 63 58 65 68 48 54 52 54 53 51 51 43 39 45 41 43 31 32 27 29 25 28 57