Detailed Drawing - Power Dynamics, Inc.

PE Series
CHASSIS MOUNT, SINGLE AND DOUBLE STAGE EMI/RFI LINE FILTER.
MECHANICAL DIMENSIONS (Unit: mm)
75.0
L
L'
0.80 TYP.
2x
N
5.00
N'
89.0
3.5x2 TYP.
FEATURES
The PE series provides general-purpose common mode and
differential mode filters. These filters are designed in a small
package and offers single and double stage filtering.
6.40 TYP.
G
APPLICATIONS
Computer & networking equipment, Measuring & control
equipment, Data processing equipment, laboratory instruments,
Switching power supplies, other electronic equipment.
51.0
TECHNICAL DATA
37.0
•
•
•
•
•
Rated Voltage: 250VAC
Rated Current: 5A, 10A, 15A, 20A, 30A
Power Line Frequency: 60Hz
Leakage Current: 0.8mA, 250VAC
Hipot Rating (one minute)
Line to Ground: 2250VDC
Line to Line: 1450VDC
• Temperature Range: -25C to +85C
Specifications subject to change without notice. Dimensions (mm).
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: [email protected] • www.powerdynamics.com
31
PE Series Example & Ordering Code
PE
CURRENT RATING (A):
=
=
=
=
=
TERMINAL:
Q - 1
05
05
10
15
20
30*
QUICK CONNECT
=Q
SCREW
= PS
SCHEMATIC:
(ONE STAGE)
=1
(TWO STAGE)
=2
* Screw Mount Only
PE Series Attenuation Tables
Non-Medical Applications
Insertion loss in dB (50 Ohm circuit)
ONE STAGE
TWO STAGE
Current
Rating
Inductance
in mH
5A
10A
15A
20A
30A
5.0
3.0
2.0
0.9
0.5
Comm. Mode(L-G) MHz
Diff. mode(L-L) MHz
.15 .5 1 5 10 30 .15 .5 1 5 10 30
6
28
23
14
16
42
42
39
22
24
38
37
31
24
26
35
34
28
31
29
37
34
30
34
38
32
35
23
28
39
30
5
9
9
14
40
44
39
32
22
33
42
37
31
34
29
39
33
36
35
31
40
36
39
42
27
38
27
34
40
Current
Rating
Inductance
in mH
5A
10A
15A
20A
5.0
1.2
0.9
0.5
Comm. Mode(L-G) MHz
Diff. mode(L-L) MHz
.15 .5 1 5 10 30 .15 .5 1 5 10 30
53
26
28
14
84
63
57
39
70
76
68
49
58
66
67
63
53
62
63
59
51
42
46
38
7
8
15
13
57
77
33
25
58
72
60
57
57
62
59
64
52
57
56
57
48
53
61
45
SCHEMATICS
Cx
0.1 F
Cx
0.1 F
N'
N
L mH
32
Cy
3300pF
G
N
L mH
L mH
L
LINE
LINE
G
10M
L'
LOAD
L mH
L
Cx
0.1 F
Cx
0.1 F
10M
Cy
3300pF
L'
Cx
0.1 F
LOAD
TWO STAGE
ONE STAGE
N'
L mH
L mH
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: [email protected] • www.powerdynamics.com