PB custom-new - Power Dynamics, Inc.

PB Custom Series
MECHANICAL DIMENSIONS
(Unit: mm)
FLANGE MOUNT
50.1
40.0
30.3
28.5
4-R5
22.5
21.6
240.0
3.3
45.5
3.5
SUGGESTED PANEL CUTOUT
(MOUNTING FROM FRONT)
41.4
46.8
55.8
G
28.3
20.6
SNAP-IN (SNT)
FEATURES
The filters in this series are designed to meet the ever changing
needs of the Electronic and Medical industry. The filters can be
made with various cable assemblies with or without braided
shields to protect equipment when the noise generating device
is located at a distance within the equipment. The shielded
filter assemblies contain braiding that terminates 360 degrees
inside the metal can to prevent any noise entering the filter.
PDI can mold custom connectors at the end of the wires in
any form or shape while the braiding is twisted to form the
drain wire.
31.0
24.0
Computer & networking equipment, Measuring & control
equipment, Data processing equipment, laboratory instruments,
Switching power supplies, other electronic equipment.
TECHNICAL DATA
• Rated Voltage: 125/250VAC
• Rated Current: 1A, 2A, 3A, 6A, 10A, 15A
• Power Line Frequency: 50/60Hz
• Max. Leakage Current each
Line to Ground:
@ 115VAC 60Hz: 0.25mA, max
@ 250VAC 50Hz: 0.45mA, max
• Hipot Rating (one minute)
Line to Ground: 2250VDC
Line to Line: 500VDC
• Temperature Range: -25C to +85C
21.2
4-R2
4-R2
28.5
29.6
SUGGESTED PANEL CUTOUT** SUGGESTED PANEL CUTOUT**
(MOUNTING FROM FRONT)
(MOUNTING FROM FRONT)
SNT Option
SSI Option
3.75
55.2
43.6
A ground choke can be added to enhance the grounding
ability of the circuit. A bleeder resistor is added to prevent
excessive voltages from developing across the filter
capacitors when there is no load.
APPLICATIONS
21.9
28.3
20.6
FLANGE MOUNT (B)
52
40.0
40
28.5
4-R5
21.6
25
2-
30.3
3.3
45.5
3.5
SUGGESTED PANEL CUTOUT
(MOUNTING FROM FRONT)
41.4
46.8
55.8
G
28.3
20.6
Specifications subject to change without notice. Dimensions (mm). See Appendix A for
recommended power cord. See PDI full line catalog for detailed specifications on power cords.
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: [email protected] • www.powerdynamics.com
11
PB Custom Series
(contact PDI with your custom options)
01
02
03
06
10
15*
1
L mH
L
L'
R
Cy
CX
G'
L
Cy
N
LOAD
=
=
=
=
=
=
LINE
CURRENT RATING (A):
SCHEMATICS
N'
L mH
G
Lg
TERMINAL:
2
QUICK CONNECT, SOLDER, WIRE HARNESS
L mH
NO BLEEDER RESISTOR & NO GROUND CHOKE
BLEEDER RESISTOR (1/4 W, 1M)
BLEEDER RESISTOR (1/2 W, 1M)
N
BLEEDER RESISTOR (1/4 W, 1M) & GROUND CHOKE
G
L'
Cy
R
G'
L
Cy
LOAD
L
LINE
OPTIONS:
N'
L mH
Lg
BLEEDER RESISTOR (1/2 W, 1M) & GROUND CHOKE
3
GROUND CHOKE ONLY
L mH
LINE
SEE SCHEMATICS
R
Cy
CX
L
G'
Cy
N'
N
ATTENUATION CODE TABLE:
Non-Medical applications, select Attenuation code with corresponding component values from the table.
✘
1.05
✘
✘
✘
✘
✘
✘
1.05
1.05
10A
0.2
0.3
0.3
0.3
0.3
0.3
0.3
0.2
0.3
0.3
0.3
15A
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
=
=
=
=
=
=
=
=
=
=
=
A
B
C
D
E
F
G
H
I
J
K
=
=
=
=
=
=
=
=
M1
M2
M3
M4
M5
M6
M7
M8
Medical applications, select Attenuation code with corresponding component values from the table.
Cx
(µF)
0.1
0.015
0.1
0.047
0.033
0.22
0.047
0.033
1A
6.5
1.9
3.7
4.6
9.5
6.5
10.5
5
TYPE OF MOUNTING:
Inductance Per Current Rating (mH)
2A
3A
6A
8A
3.8
2.5
0.8
1.05
✘
1.5
1.1
0.6
✘
✘
2.7
1.8
✘
3.4
2.5
0.9
✘
4.3
1.8
0.85
4.0
2.5
0.8
1.05
✘
4
1.2
0.53
✘
✘
3.7
0.6
10A
0.2
0.3
0.3
0.3
0.3
0.3
15A
0.2
0.2
✘
0.2
0.2
0.2
✘
✘
0.2
✘
4
L mH
L
L'
R
L
N
N'
L mH
G
MEDICAL
SCHEMATICS
1M
L mH
L
L'
R
CX
L
N
N'
L mH
G
LINE
SNAP-IN TABS - TOP BOTTOM
SNAP-IN TABS - SIDE
L mH
L'
R
L
N
CX
N'
L mH
G
TERMINATION OPTIONS:
G'
Lg
L
SPECIAL FLANGE MOUNT
G'
Lg
2M
STANDARD FLANGE MOUNT
LOAD
8A
1.05
Lg
LOAD
(mH)
LOAD
1A
6.5
1.9
3.7
10.5
4.6
9.5
10.5
5.0
10.5
6.5
6.5
Inductance Per Current Rating
2A
3A
6A
3.8
2.5
0.8
1.5
1.1
0.6
2.7
1.8
0.8
4.2
2.5
1.05
3.4
2.5
0.9
4.3
1.8
0.85
4.0
1.2
0.53
3.7
1.8
0.6
6.5
2.5
1.05
4.0
2.5
0.8
4.0
2.5
0.8
G
LINE
Cy
(pF)
2200
3300
3300
1000
3300
3300
2200
2200
without Cy
2200
3300
L mH
LINE
Cx
(µF)
0.1
0.015
0.1
0.1
0.047
0.033
0.047
0.033
without Cx
0.22
0.22
LOAD
L'
L
COMPONENT LOCATION:
G'
Lg
TERMINATIONS CAN BE MOLDED OR CAN TERMINALTE WITH ANY TERMINALS REQUESTED BY THE CUSTOMER.
*10A for TUV; 15A for UL & cUL
✘
Contact PDI for availability
12
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: [email protected] • www.powerdynamics.com