SAMTEC LABORATORY TEST PROCEDURES

TEST LAB PROCEDURAL MANUAL
TCXXXX—XXXX
INITIAL RELEASE
SAMTEC LABORATORY
TEST PROCEDURES
FIGURE, TABLE AND PARAGRAPH DESIGNATIONS HAVE
BEEN MAINTAINED AS IN THE ORIGINAL INDIVIDUAL
DOCUMENTS
©Samtec, Inc.
Page 1 of 18
Revised: 1/31/2008
TEST LAB PROCEDURAL MANUAL
TCXXXX—XXXX
INITIAL RELEASE
TLPM-032
CURRENT CARRYING CAPACITY
1. Purpose
1.1. To determine the amount of current the device under test (DUT) can safely carry
over the operating temperature range of the DUT.
1.2. Contact loading will also be addressed in this document which will determine
how much current can be carried as the number of energized contacts is varied.
2. Definitions
DUT – Device Under Test
3. Reference Documents
3.1. EIA-364-70, Temperature Rise Versus Current Test Procedure for Electrical
Connectors and Sockets
3.2. Samtec Document; TLSC 0002, Automated TempRise Software
3.3. Samtec Document; TLWI 0005, Thermocouple Calibration Work Instruction
3.4. Samtec Document; TLOP 0006, Automated Temperature Rise Versus Current
Measurement
3.5. EIA-364-06 Contact Resistance
4. Samples
4.1. Three samples shall be tested for each loading configuration. The DUTs shall be
configured as follows:
4.2. For single row power connectors the following configurations are to be tested:
4.2.1. 1 contact energized only
4.2.2. 2 contacts energized adjacent to each other
4.2.3. 3 contacts energized adjacent to each other
4.2.4. 4 contacts energized adjacent to each other
4.2.5. All contacts energized (list actual number tested)
4.3. For double row power connectors the following configurations are to be tested:
4.3.1. 2x1 contact energized only
4.3.2. 2x2 contacts energized adjacent to each other
4.3.3. 2x3 contacts energized adjacent to each other
4.3.4. 2x4 contacts energized adjacent to each other
4.3.5. All contacts energized (list actual number tested)
4.4. The following defines the sample/thermocouple designations and the data
acquisition channel connections:
4.4.1. 1 contact energized: Samples 1 through 3, connected to Channels 1 - 3
4.4.2. 2 contacts energized: Samples 4 through 6, connected to Channels 4 - 6
4.4.3. 3 contacts energized: Samples 7 through 9, connected to Channels 7 - 9
4.4.4. 4 contacts energized: Samples 10 through 12, connected to Channels 10 12
4.4.5. All contacts energized: Samples 13 through 15, connected to Channels 13
– 15
4.4.6. Ambient temp and Wire temp will be monitored on channels 16 and 17
©Samtec, Inc.
Page 2 of 18
Revised: 1/31/2008
TEST LAB PROCEDURAL MANUAL
TCXXXX—XXXX
INITIAL RELEASE
5. Setup
5.1. All test samples shall be wired in a series circuit in accordance with Table 1 and
Table 2 below to insure equal current through all samples.
5.2. Five positions on the “100%” samples shall also be wired for Voltage Drop
measurements.
5.3. A thermocouple shall be placed as close to the contact interface as possible such
as the locations indicated by the red dot and arrow in Figure 1.
Figure 1
5.4. When necessary, a small hole shall be drilled through the connector body at the
proper location to allow a thermocouple to be placed at the contact interface.
Figure 2
©Samtec, Inc.
Page 3 of 18
Revised: 1/31/2008
TEST LAB PROCEDURAL MANUAL
TCXXXX—XXXX
INITIAL RELEASE
5.5. A small amount of non-silicone, heat sink compound shall be placed at the tip of
the thermocouple prior to installation in order to improve the thermal transfer
characteristics of the contact/thermocouple interface (indicated below in green).
Figure 3
Thermocouple Weld
Thermocouple Wire Jacket
Pin
Under
Test
Thermocouple Wires
Socket
Under
Test
Heat Sink Compound
5.6. Said thermocouple/s shall be mechanically stabilized using small blocks of
adhesive foam as illustrated in Figure 4.
Figure 4
5.7. The hole shall be sealed with tape or putty after the thermocouple is installed.
5.8. One thermocouple shall be placed in the ambient environment within the test
chamber held in the fixture as specified in EIA-364-70.
5.9. One thermocouple shall be placed on the supply wire/cable or PCB as applicable
to insure that the wire/cable/PCB is not influencing to the test data.
©Samtec, Inc.
Page 4 of 18
Revised: 1/31/2008
TEST LAB PROCEDURAL MANUAL
TCXXXX—XXXX
INITIAL RELEASE
5.10. The DUTs shall be placed in one of the test chambers (enclosure) designated to
shield against external airflow. Use an appropriate enclosure of sufficient size
to accommodate the DUTs as follows:
5.10.1. The DUTS shall be suspended in free air. In the event free air suspension
not feasible, a low thermal conduction material (e.g., plastic, wood, glassepoxy board, etc.) shall be used for support, provided a maximum of 20%
of the DUT’s surface is in contact with the insulating surface. Samples
shall be arranged horizontally and shall meet the following requirements:
5.10.2. DUTs shall be mounted a minimum of 8 inches (20 centimeters) from the
walls of the test chamber.
5.10.3. Specimens shall be no closer than 6 inches (15 centimeters) from the top
of the enclosure or room.
5.10.4. If free air suspension is used, the specimens shall be a minimum of 2
inches (5 centimeters) above the bottom of the room or enclosure.
5.10.5. See Figures 5 and 6 for typical specimen mounting and wiring layout.
Figure 5
Figure 6
©Samtec, Inc.
Page 5 of 18
Revised: 1/31/2008
TEST LAB PROCEDURAL MANUAL
TCXXXX—XXXX
INITIAL RELEASE
©Samtec, Inc.
Page 6 of 18
Revised: 1/31/2008
TEST LAB PROCEDURAL MANUAL
TCXXXX—XXXX
INITIAL RELEASE
5.11. Printed circuit board components
5.11.1. Any DUT that is meant to be printed circuit board (PCB) mounted in
actual use shall be tested on an appropriate PCB as would be used in the
final application.
5.11.2. For PCB mounted devices, the current carrying traces shall be capable of
carrying the maximum current that is to be applied without contributing to
the thermal increase of the DUT being measured. See table 1 below.
5.11.3. Optionally, wires can be attached directly to the terminations of the
device.
5.11.4. EIA-364-70 recommends the trace technique not be utilized for test
currents greater than 13 amperes. See Table 2 for wire/conductor
requirements.
5.12.
A digital photograph shall be taken of one test sample prepared for test,
with thermocouple installed. This photo shall be stored in the folder with the test
data.
6. PRINTED CIRCUIT BOARD AND WIRE SPECIFICATIONS
Table 1
TEST
CURRENT
Amps
0.1
0.5
1.5
2.0
3.0
7.5
13.0
EQUIVALENT
WIRE SIZE
AWG
36
32
28
26
24
20
16
TRACE
WIDTH
cm
0.03
0.06
0.13
0.19
0.25
0.64
1.27
TRACE
LENGTH
in
0.01
0.03
0.05
0.08
0.10
0.25
0.50
cm
1.30
2.30
3.00
3.80
4.30
6.90
9.40
in
0.50
0.90
1.20
1.50
1.70
2.70
3.70
Notes from the EIA:
1. The above trace widths and lengths are based on 1.0 oz copper.
2. The table applies to single sided test boards. Put in the multi-layer and double-sided calcs from the
pcb calculator
3. Minimum length is a slight function of temperature rise criteria assumed that is 30°C. For
temperature rise criteria less than 30°C, these values are conservative.
©Samtec, Inc.
Page 7 of 18
Revised: 1/31/2008
TEST LAB PROCEDURAL MANUAL
TCXXXX—XXXX
INITIAL RELEASE
Table 2
CONDUCTOR CHARACTERISTICS
Wire Size
Test current
Minimum Wire
Length
AWG
amperes
cm
in
36
0.9
4
1.5
34
1.2
5
2.0
32
1.5
5
2.0
30
2.0
8
3.0
28
2.7
9
3.5
26
3.6
11
4.5
24
4.8
14
5.5
22
6.4
16
6.5
20
8.5
20
8.0
18
11
25
10.0
16
15
29
11.5
14
20
36
14.0
12
27
42
16.5
10
35
50
19.5
8
47
57
22.5
6
63
67
26.5
4
84
79
31.0
2
111
93
36.5
0
148
108
42.5
00
171
117
46.0
000
197
126
49.5
0000
227
136
53.5
7. Testing
7.1. The data acquisition system used will measure the Temperature Rise and Voltage
Drop of all positions being tested.
7.1.1. Seventeen calibrated thermocouples shall be connected to channels one
through seventeen of the acquisition scanner card.
7.1.2. Fifteen pairs of Voltage Drop wires will be connected from samples
thirteen through fifteen to channels eighteen through thirty-two.
7.2. The series circuit of test samples shall be connected to an appropriate power
supply, capable of the required power levels (see section 9.1).
7.3. Once the above set up and preparations are completed the computer program
shall be initialized and the test allowed to run to completion.
7.4. Temperature and Voltage Drop measurements shall be performed in accordance
with EIA-364-70B.
7.5. Testing will be performed at five different current levels in order to generate a
Current Derating curve via regression analysis.
8. Data Analysis Data shall be provided in the following formats:
8.1. Temperature Rise (degrees Celsius above ambient).
8.2. Current Derating curve based on the Temp Rise data.
8.3. Voltage Drop (Contact Resistance at Rated Current)
©Samtec, Inc.
Page 8 of 18
Revised: 1/31/2008
TEST LAB PROCEDURAL MANUAL
TCXXXX—XXXX
INITIAL RELEASE
9. Required Equipment
9.1. The power supply used and the test current required will limit the number of
contacts that can be tested at one time.
9.1.1. The three factors involved in determining this limit are:
a) Total Resistance of the contact chain including all cables and connections.
b) Test Current to be carried by said system.
c) Maximum Open Circuit Voltage of the power supply
9.1.2. The formula is Voc ÷ It = Rt ; Where:
a) Voc is the Open Circuit Voltage required
b) It is the Test Current
c) Rt is the total resistance of the test circuit
9.1.3. This is also limited by the total power available as specified in the Power
Supply manual
9.2. The data acquisition system used to measure the Temperature Rise and Voltage
Drop shall be equipped with the following:
9.2.1. Seventeen scanner channels capable of Type-J thermocouple temperature
measurements
9.2.2. Fifteen channels capable of measuring Voltage Drop.
TYPE
USE
Keithley Model 7700,20 channel multiplexer
Provide computer controlled switching with
thermocouple inputs. Installs into a Keithley
Model 2700 Multimeter/Data Acquisition System
For reliable temperature measurements
Mainframe for 20 channel relay card
Calibrated Thermocouples (2)
Keithley Model 2750 Multimeter/Data
Acquisition System
HP System Power Supply 6032A
Thermocouple Radiation Shield # TL-022
IEEE-488 Card
PC
Keithley Model 580, Micro-Ohmmeter
10. Approvals
NAME
Computer controlled power supply
To prevent erroneous reference temperature
measurements.
Communications card for PC
To provide interface for IEEE-488
instrumentation and program control.
Measuring instrument
DEPARTMENT
Quality
Engineering
11. Revisions
REVISION DESCRIPTION
00
New
01
Added TLOP 0009 for Reference Document
©Samtec, Inc.
Page 9 of 18
DATE
DATE
10/4/02
Revised: 1/31/2008
TEST LAB PROCEDURAL MANUAL
TCXXXX—XXXX
INITIAL RELEASE
TLPM-084
CURRENT CYCLING
1. Purpose
1.1. To determine the performance of the device under test (DUT) when subjected to
the power-on/power-off cycling that heats and cools the DUT to simulate normal
everyday use.
1.2. All of the contacts (100% loading) will be powered throughout the test.
2. Definitions
DUT – Device Under Test
3. Reference Documents
3.1. EIA-364-70, Temperature Rise Versus Current Test Procedure for Electrical
Connectors and Sockets
3.2. Samtec Document; TLSC 0002, Automated TempRise Software
3.3. Samtec Document; TLWI 0005, Thermocouple Calibration Work Instruction
3.4. EIA Publication 364-06 Contact Resistance
3.5. EIA Publication 364-55 Current Cycling
4. Samples
4.1. Eight samples shall be tested in a 100% loading configuration.
4.2. Five positions per DUT shall be tested for Voltage Drop throughout the cycling
test.
4.3. One thermocouple shall be installed in each of the eight DUTs.
4.4. One thermocouple shall be placed in the ambient environment within the test
chamber held in the fixture as specified in EIA-364-70.
4.5. One thermocouple shall be placed on the supply wire/cable or PCB as applicable
to insure that the wire/cable/PCB is not influencing to the test data.
4.6. Two entire test sample groups as defined above can be performed at the same
time for a total of sixteen samples.
4.6.1. An upper chamber shall be used to test one sample set of eight devices.
4.6.2. A lower chamber shall be used to test one sample set of eight devices.
©Samtec, Inc.
Page 10 of 18
Revised: 1/31/2008
TEST LAB PROCEDURAL MANUAL
TCXXXX—XXXX
INITIAL RELEASE
4.7. The following defines the sample/thermocouple/Voltage Drop designations and
data acquisition channel connections:
4.7.1. The Data Acquisition System (DAS) shall be equipped with three scanner
cards.
a) Card 1 (20 channels), Lower chamber thermocouples shall be connected to
channels one through eight
b) Card 1, Upper chamber thermocouples shall be connected to channels nine
through sixteen
c) Card 2 (40 channels), All forty channels shall be connected to the Lower
chamber devices under test (5 contacts/device).
d) Card 3 (40 channels), All forty channels shall be connected to the upper
chamber devices under test (5 contacts/device).
5. Setup
5.1. All test samples shall be wired in a series circuit in accordance with Table 1 and
Table 2 below to insure equal current through all samples.
5.2. All connectors under test shall be wired for five Voltage Drop measurements
each.
5.3. When necessary, a small hole shall be drilled through the connector body at the
proper location to allow a thermocouple to be place at the contact interface.
5.4. The hole shall be sealed with tape or putty after the thermocouple is installed.
5.5. One thermocouple shall be placed in the ambient environment within the test
chamber held in the fixture as specified in EIA-364-70.
5.6. One thermocouple shall be placed on the supply wire/cable or PCB as applicable
to insure that the wire/cable/PCB is not influencing to the test data.
5.7. The DUTs shall be placed in one of the test chambers (enclosure) designated to
shield against external airflow. Use an appropriate enclosure of sufficient size to
accommodate the DUTs as follows:
5.7.1. The DUTS shall be suspended in free air. In the event free air suspension
not feasible, a low thermal conduction material (e.g., plastic, wood, glassepoxy board, etc.) shall be used for support, provided a maximum of 20%
of the DUT’s surface is in contact with the insulating surface. Samples
shall be arranged horizontally and shall meet the following requirements:
5.7.2. DUTs shall be mounted a minimum of 8 inches (20 centimeters) from the
walls of the test chamber.
5.7.3. Specimens shall be no closer than 6 inches (15 centimeters) from the top
of the enclosure or room.
5.7.4. If free air suspension is used, the specimens shall be a minimum of 2
inches (5 centimeters) above the bottom of the room or enclosure.
5.7.5. See figure 1 for typical specimen mounting and wiring layout.
©Samtec, Inc.
Page 11 of 18
Revised: 1/31/2008
TEST LAB PROCEDURAL MANUAL
TCXXXX—XXXX
INITIAL RELEASE
Figure 1
5.8. When necessary, a small hole shall be drilled through the connector body at the
proper location to allow a thermocouple to be placed at the contact interface.
Figure 2
5.9. A small amount of non-silicone, heat sink compound shall be placed at the tip of
the thermocouple prior to installation in order to improve the thermal transfer
characteristics of the contact/thermocouple interface (indicated below in green).
©Samtec, Inc.
Page 12 of 18
Revised: 1/31/2008
TEST LAB PROCEDURAL MANUAL
TCXXXX—XXXX
INITIAL RELEASE
Figure 3
Thermocouple Weld
Thermocouple Wire Jacket
Pin
Under
Test
Thermocouple Wires
Socket
Under
Test
Heat Sink Compound
5.10. Said thermocouple/s shall be mechanically stabilized using small blocks of
adhesive foam as illustrated in Figure 4.
Figure 4
5.11. The hole shall be sealed with tape or putty after the thermocouple is installed.
5.12. One thermocouple shall be placed in the ambient environment within the test
chamber held in the fixture as specified in EIA-364-70.
5.13. One thermocouple shall be placed on the supply wire/cable or PCB as
applicable to insure that the wire/cable/PCB is not influencing to the test data.
©Samtec, Inc.
Page 13 of 18
Revised: 1/31/2008
TEST LAB PROCEDURAL MANUAL
TCXXXX—XXXX
INITIAL RELEASE
5.14. The DUTs shall be placed in one of the test chambers (enclosure) designated to
shield against external airflow. Use an appropriate enclosure of sufficient size
to accommodate the DUTs as follows:
5.14.1. The DUTS shall be suspended in free air. In the event free air suspension
not feasible, a low thermal conduction material (e.g., plastic, wood, glassepoxy board, etc.) shall be used for support, provided a maximum of 20%
of the DUT’s surface is in contact with the insulating surface. Samples
shall be arranged horizontally and shall meet the following requirements:
5.14.2. DUTs shall be mounted a minimum of 8 inches (20 centimeters) from the
walls of the test chamber.
5.14.3. Specimens shall be no closer than 6 inches (15 centimeters) from the top
of the enclosure or room.
5.14.4. If free air suspension is used, the specimens shall be a minimum of 2
inches (5 centimeters) above the bottom of the room or enclosure.
5.14.5. See Figures 5 and 6 for typical specimen mounting and wiring layout.
Figure 5
©Samtec, Inc.
Page 14 of 18
Revised: 1/31/2008
TEST LAB PROCEDURAL MANUAL
TCXXXX—XXXX
INITIAL RELEASE
Figure 6
©Samtec, Inc.
Page 15 of 18
Revised: 1/31/2008
TEST LAB PROCEDURAL MANUAL
TCXXXX—XXXX
INITIAL RELEASE
5.15. Printed circuit board components
5.15.1. Any DUT that is meant to be printed circuit board (PCB) mounted in
actual use shall be tested on an appropriate PCB as would be used in the
final application.
5.15.2. For PCB mounted devices, the current carrying traces shall be capable of
carrying the maximum current that is to be applied without contributing to
the thermal increase of the DUT being measured. See table 1 below.
5.15.3. Optionally, wires can be attached directly to the terminations of the
device.
5.15.4. EIA-364-70 recommends the trace technique not be utilized for test
currents greater than 13 amperes. See Table 2 for wire/conductor
requirements.
5.16.
A digital photograph shall be taken of one test sample prepared for test,
with thermocouple installed. This photo shall be stored in the folder with the test
data.
6. PRINTED CIRCUIT BOARD AND WIRE SPECIFICATIONS
Table 1
TEST
CURRENT
Amps
0.1
0.5
1.5
2.0
3.0
7.5
13.0
EQUIVALENT
WIRE SIZE
AWG
36
32
28
26
24
20
16
TRACE
WIDTH
cm
0.03
0.06
0.13
0.19
0.25
0.64
1.27
TRACE
LENGTH
in
0.01
0.03
0.05
0.08
0.10
0.25
0.50
cm
1.30
2.30
3.00
3.80
4.30
6.90
9.40
in
0.50
0.90
1.20
1.50
1.70
2.70
3.70
Notes from the EIA:
4. The above trace widths and lengths are based on 1.0 oz copper.
5. The table applies to single sided test boards. Put in the multi-layer and double-sided calcs from the
pcb calculator
6. Minimum length is a slight function of temperature rise criteria assumed that is 30°C. For
temperature rise criteria less than 30°C, these values are conservative.
©Samtec, Inc.
Page 16 of 18
Revised: 1/31/2008
TEST LAB PROCEDURAL MANUAL
TCXXXX—XXXX
INITIAL RELEASE
Table 2
CONDUCTOR CHARACTERISTICS
Wire Size
Test current
Minimum Wire
Length
AWG
amperes
cm
in
36
0.9
4
1.5
34
1.2
5
2.0
32
1.5
5
2.0
30
2.0
8
3.0
28
2.7
9
3.5
26
3.6
11
4.5
24
4.8
14
5.5
22
6.4
16
6.5
20
8.5
20
8.0
18
11
25
10.0
16
15
29
11.5
14
20
36
14.0
12
27
42
16.5
10
35
50
19.5
8
47
57
22.5
6
63
67
26.5
4
84
79
31.0
2
111
93
36.5
0
148
108
42.5
00
171
117
46.0
000
197
126
49.5
0000
227
136
53.5
7. Testing
7.1. The data acquisition system used will measure the Temperature Rise and Voltage
Drop of all positions being tested.
7.1.1. Twenty calibrated thermocouples shall be connected to channels one
through twenty of the acquisition scanner card 1.
7.1.2. Forty pairs of Voltage Drop wires will be connected from the lower
chamber test samples to the DAS card 2.
7.1.3. Forty pairs of Voltage Drop wires will be connected from the upper
chamber test samples to the DAS card 3.
7.2. The series circuit of test samples shall be connected to an appropriate power
supply, capable of the required power levels (see section 9.1).
7.3. Once the above set up and preparations are completed the computer program
shall be initialized and the test allowed to run to completion.
7.4. Temperature and Voltage Drop measurements shall be performed in accordance
with EIA-364-70B.
7.5. Testing will be performed at five different current levels in order to generate a
Current Derating curve via regression analysis.
©Samtec, Inc.
Page 17 of 18
Revised: 1/31/2008
TEST LAB PROCEDURAL MANUAL
TCXXXX—XXXX
INITIAL RELEASE
8. Data Analysis Data shall be provided in the following formats:
8.1. Temperature Rise (degrees Celsius above ambient).
8.2. Current Derating curve based on the Temp Rise data.
8.3. Voltage Drop (Contact Resistance at Rated Current)
9. Required Equipment
9.1. The power supply used and the test current required will limit the number of
contacts that can be tested at one time.
9.1.1. The three factors involved in determining this limit are:
a) Total Resistance of the contact chain including all cables and connections.
b) Test Current to be carried by said system.
c) Maximum Open Circuit Voltage of the power supply
9.1.2. The formula is Voc ÷ It = Rt ; Where:
a) Voc is the Open Circuit Voltage required
b) It is the Test Current
c) Rt is the total resistance of the test circuit
9.1.3. This is also limited by the total power available as specified in the Power
Supply manual
9.2. The data acquisition system used to measure the Temperature Rise and Voltage
Drop shall be equipped with the scanning cards listed below:
TYPE
USE
Keithley Model 7700,20 channel multiplexer
Provide computer controlled switching with
thermocouple inputs. Installs into a Keithley
Model 2700 Multimeter/Data Acquisition System
For reliable temperature measurements
Mainframe for 20 channel relay card
Calibrated Thermocouples (2)
Keithley Model 2750 Multimeter/Data
Acquisition System
HP System Power Supply 6032A
Thermocouple Radiation Shield # TL-022
IEEE-488 Card
PC
Keithley Model 580, Micro-Ohmmeter
10. Approvals
NAME
Computer controlled power supply
To prevent erroneous reference temperature
measurements.
Communications card for PC
To provide interface for IEEE-488
instrumentation and program control.
Measuring instrument
DEPARTMENT
Quality
Engineering
11. Revisions
REVISION DESCRIPTION
00
New
01
Added TLOP 0009 for Reference Document
©Samtec, Inc.
Page 18 of 18
DATE
DATE
10/4/02
Revised: 1/31/2008