POWER INTEGRITY TEST REPORT 193177 Revision 4

Project Number: 193177
Tracking Code:
Requested by: Eric Mings
Date: 8/6/2012
Part #: MMSS-25-24-L-12.00-D-K-LUS
193177_Power Report_ Rev 4
Product Rev: W
Lot #: «Lot_Number»
Tech: Tony Wagoner
Part description: 0.100[2.54] Socket Discrete Cable Assembly
Test Start: 6/16/2012
Eng: Eric Mings
Qty to test: 23
Test Completed: 7/27/2012
SAMTEC POWER CHARACTERIZATION
PART DESCRIPTION:
0.100[2.54] Socket Discrete Cable Assembly
MMSS-25-24-L-12.00-D-K-LUS
IPL1-125-01-L-S-K
193177_Power Report_ Rev 4
Page 1 of 24
5/28/2013
POWER INTEGRITY TEST
REPORT
193177
Revision 4
CERTIFICATION
All instruments and measuring equipment were calibrated to National Institute for Standards and Technology (NIST)
traceable standards according to IS0 10012-l and ANSI/NCSL 2540-1, as applicable.
All contents contained herein are the property of Samtec. No portion of this report, in part or in full shall be
reproduced without prior written approval of Samtec.
SCOPE
1. Temperature Rise/Current Carrying Capacity
1.1. To determine the amount of current the device under test (DUT) can safely carry over the operating
temperature range of the DUT.
1.2. Contact loading will also be addressed in this document which will determine how much current can be
carried as the number of energized contacts is varied.
2. Current Cycling
2.1. To determine the performance of the device under test (DUT) when subjected to the power-on/power-off
cycling that heats and cools the DUT in normal everyday use.
2.2. Contact loading will set to 100% throughout the test.
APPLICABLE DOCUMENTS
Standards: EIA Publication 364-70 Temperature Rise
EIA Publication 364-06 Contact Resistance
EIA Publication 364-55 Current Cycling
TLPM-032 Current Carrying Capacity
TLPM-084 Current Cycling
IEC 512-3 Electromechanical Components for Electronic Equipment: Basic Testing Procedures
and Measuring Methods, Part 3: Current Carrying Capacity Tests
TEST SAMPLES AND PREPARATION
1.
2.
3.
4.
5.
6.
7.
8.
All materials shall be manufactured in accordance with the applicable product specification.
All test samples shall be identified and encoded to maintain traceability throughout the test sequences.
After soldering, the parts to be used shall be cleaned according to TLWI-0001.
All samples shall be visually inspected and cleaned as necessary.
Any additional preparation shall be noted in the individual test sequences.
Solder Information: Lead Free
Re-Flow Time/Temp: See accompanying profile.
All products designed to operate mounted on a printed circuits board shall be tested mounted to test boards in
accordance with EIA-364-70.
193177_Power Report_ Rev 4
Page 2 of 24
5/28/2013
POWER INTEGRITY TEST
REPORT
193177
Revision 4
PREPARED TEST SAMPLE
9. The following loading configurations shall be tested for Temperature Rise/Current Carrying Capacity testing of
single row connector systems:
9.1. One contact energized only
9.2. Two contacts energized adjacent to each other
9.3. Three contacts energized adjacent to each other
9.4. Four contacts energized adjacent to each other
9.5. All contacts energized
Test Condition as in 9.1 above
Indicates energized contacts
Indicates thermocouple monitored, energized contacts
10. For Current Cycling, only 100 % loading will be tested.
193177_Power Report_ Rev 4
3 of 24
5/28/2013
POWER INTEGRITY TEST
REPORT
193177
Revision 4
FLOWCHARTS
Current Carrying Capacity
3 Mated Assemblies Each
TEST
GROUP A
GROUP B
GROUP C
GROUP D
GROUP E
STEP
3 Mated Assemblies
3 Mated Assemblies
3 Mated Assemblies
3 Mated Assemblies
3 Mated Assemblies
1 CONTACT POWERED
2 CONTACTS POWERED
3 CONTACTS POWERED
4 CONTACTS POWERED
ALL CONTACTS POWERED
CCC
CCC
CCC
CCC
CCC
01
(TIN PLATING) - Tabulate calculated current at RT, 65° C, 75° C and 95° C
after derating 20% and based on 105° C
(GOLD PLATING) - Tabulate calculated current at RT, 85° C, 95° C and 115° C
after derating 20% and based on 105° C
CCC, Temp rise = EIA-364-70
Current Cycling
GROUP A
TEST
8 Mated Assemblies
STEP
ALL CONTACTS POWERED
01
Current Cycle, 500 cycles at
125% of Rated current
Current Cycle = EIA 364-55, Condition "B", Method #4
Test at Current 125% of Rated Current
Measure at 45 minutes into ON time of cycle
Measure Voltage Drop on 5 random contacts
193177_Power Report_ Rev 4
4 of 24
5/28/2013
POWER INTEGRITY TEST
REPORT
193177
Revision 4
TEST PROCEDURES
MMSS-25-24-L-12.00-D-K-LUS
IPL1-125-01-L-S-K
Part No.
Mating Part No.
15
Tony Wagoner
Sample Size
Technician
6/16/2012
6/18/2012
Start Date
Complete Date
50%
22.8C
Room Ambient
Relative Humidity
Equipment ID#: MO-09, PS-09, TCS-039, TCS-047, TCS-009, TCS-042, TCS-019, TCS-045, TCS-051, TCS-043,
TCS-033, TCS-050, TCS-012, THL-10, RS-01
TEMPERATURE RISE (Current Carrying Capacity, CCC):
1. Thermocouples shall be calibrated in accordance with Samtec documents; TLWI 0003, Thermocouple Welding
Procedure and TLWI 0005, Thermocouple Calibration
2. The thermocouples shall be placed at a location to sense the maximum temperature generated during testing.
3. Temperature stability shall be defined as the temperature at which three successive readings, 5 minutes apart,
differ not more than 1° C (computer controlled data acquisition). This is the Temperature Rise that the Current
Carrying Capacity and De-rating curves are based on.
4. The following loading configurations shall be tested (double for two row systems):
a) One contact energized only
b) Two contacts energized adjacent to each other
c) Three contacts energized adjacent to each other
d) Four contacts energized adjacent to each other
e) All contacts energized
5. The following loading configurations shall be tested for Temperature Rise/Current Carrying Capacity testing of
two row connector systems:
a) Two by One contact energized
b) Two by Two contacts energized adjacent to each other
c) Two by Three contacts energized adjacent to each other
d) Two by Four contacts energized adjacent to each other
e) All contacts energized
6. Three samples shall be tested for each of the above configurations for a total of eighteen assemblies.
7. Temperature Rise measurements shall be made at 5 different current levels yielding temperature rises in the 10 to
70C range.
8. The base curve for the Current Rating chart will be derived from the average (maximum) value of three test
specimens in accordance with IEC 512-3, Test 5b.
193177_Power Report_ Rev 4
5 of 24
5/28/2013
POWER INTEGRITY TEST
REPORT
193177
Revision 4
MMSS-25-24-L-12.00-D-K-LUS Mating Part No.
IPL1-125-01-L-S-K
Part No.
8
Tony Wagoner
Sample Size
Technician
7/6/2012
7/27/2012
Start Date
Complete Date
53%
24.8C
Room Ambient
Relative Humidity
Equipment ID#: MO-10;TCS-036;TCS-019;TCS-028;TCS-033;TCS-011;TCS-037;TCS-014;TCS-029;TCS-002;TCS044;THL-10;RS-03
CURRENT CYCLING
1. Samples shall be prepared and tested as above (paragraph 14.5).
2. Current Cycling shall be performed in accordance with EIA-364-55, Test Condition
3. Testing shall be as follows:
3.1. Test Current:
TEST CURRENT(125% of 30C Rating)
3.2. “ON” Time:
45 Minutes
3.3. “OFF” Time:
15 Minutes
3.4. Number of Cycles:
500
3.5. Measurements:
40 minutes into ON cycle
3.5.1. Temperature
3.5.2. Voltage Drop/Contact Resistance
4. Temperature vs. Number of Cycles and Voltage Drop vs. Number of Cycles shall be measured and recorded.
193177_Power Report_ Rev 4
6 of 24
5/28/2013
POWER INTEGRITY TEST
REPORT
193177
Revision 4
TEST RESULTS
CURRENT CARRYING CAPACITY (CCC) RESULTS
 There was no evidence of physical damage to the test samples as tested.
 The following is a summary of the observed data:
Temperature Rise, CCC at a 20% de-rating
 CCC for a 30°C Temperature Rise -----------------------4.6A per contact with 1 contacts (1 x 1) powered

CCC for a 30°C Temperature Rise -----------------------4.0A per contact with 2 contacts (1 x 2) powered

CCC for a 30°C Temperature Rise -----------------------3.4A per contact with 3 contacts (1 x 3) powered

CCC for a 30°C Temperature Rise -----------------------3.2A per contact with 4 contacts (1 x 4) powered

CCC for a 30°C Temperature Rise -----------------------2.4A per contact with 25 contacts (1 x 25) powered
CURRENT CYCLING RESULTS
Test Condition: 500 Cycles, 45 minutes ON and 15 minutes OFF
 Test Current ------------------------------------------------ 3.0 Amps

Contact Resistances, Measured 40 minutes into the FIRST and LAST ON cycle
o Initial
 Min --------------------------------------36.58 mOhms
 Max--------------------------------------57.20 mOhms
o Final
 Min --------------------------------------37.06 mOhms
 Max--------------------------------------57.57 mOhms

Temperature Change, Measured 40 minutes into the FIRST and LAST ON cycle
o Initial Temperature Change ------------------31.7 °C
o Final Temperature Change -------------------31.3 °C
193177_Power Report_ Rev 4
7 of 24
5/28/2013
POWER INTEGRITY TEST
REPORT
193177
Revision 4
TEST DATA
CONTACT RESISTANCE @ RATED CURRENT - DC Resistance (DCR)
The following data represents the Voltage drop and Contact Resistance at Rated Current for the 100% energized
samples:
Resistance (mOhms)
Contact Resistance @ Rated Current
(milli-Ohms)
60
58
56
54
52
50
48
46
44
42
40
38
36
34
32
30
28
26
24
22
20
Max
0.5
1
1.5
2
2.5
3
3.5
4
Current (Amps)
CONTACT RESISTANCE DATA
ALL CONTACTS ENERGIZED
(m)
TEST CURRENT
AMPS
Min
Max
Avg
193177_Power Report_ Rev 4
1.41
34.82
42.4
35.58
2
35.39
41.38
36.15
8 of 24
2.45
36.25
39.63
36.72
2.83
36.44
38.9
37.12
3.16
36.97
39.26
37.71
5/28/2013
POWER INTEGRITY TEST
REPORT
193177
Revision 4
TEST DATA
VOLTAGE DROP @ RATED CURRENT
The following data represents the Voltage drop at Rated Current for the 100% energized samples:
Voltage Drop @ Rated Current
(milli-Volts)
150
Voltage Drop (milli-Volts)
140
130
120
110
100
Max
90
80
70
60
50
40
0.5
1
1.5
2
2.5
3
3.5
4
Current (Amps)
VOLTAGE DROP DATA
ALL CONTACTS ENERGIZED
(mV)
TEST CURRENT
AMPS
Min
Max
Avg
1.41
49.09
59.79
50.95
193177_Power Report_ Rev 4
2
70.78
82.76
73.17
Page 9 of 24
2.45
88.82
97.09
90.66
2.83
103.12
110.08
105.77
5/28/2013
3.16
116.84
124.07
120.02
POWER INTEGRITY TEST
REPORT
193177
Revision 4
CURRENT CARRYING CAPACITY DATA
Base Curve
Derated 20 %
193177 (Crimp)
1 (1x1) Contacts in Series
Part Numbers: MMSS-25-24-L-12.00-D-K-LUS / IPL1-125-01-L-S-K
RT Peak Amp
RT Derated Amp
Measured Current
Current Rating per Contact (30 Deg. Rise, 20% Derated) = 4.6 Amps
65 ° C
65 ° C Peak Amp
65 ° C Derated Amp
Room Temp= 23.0 C
75 ° C
75 ° C Peak Amp
75 ° C Derated Amp
10.0
Limit
9.5
95 ° C Peak Amp
Maximum Current, Amp per Contact
95 ° C Derated Amp
95 ° C
Room Temp
8.0
105° C
Limit
7.6
6.6
6.0
5.7
5.3
4.6
4.0
3.3
2.7
2.0
Useful
Range
0.0
20
30
40
50
60
70
80
90
100
110
Ambient Temperature, ° C
193177_Power Report_ Rev 4
10 of 24
5/28/2013
POWER INTEGRITY TEST
REPORT
193177
Revision 4
TEMPERATURE RISE DATA
ONE CONTACT ENERGIZED
(Degrees Celsius above ambient)
TEST CURRENT
AMPS
Sample 1
Sample 2
Sample 3
3.45
11.4
11.5
9.5
4.89
22.9
23.1
20.9
5.97
33.8
33.7
31.3
6.9
44.3
45.1
40.5
7.71
55.2
57
50.5
Min
Max
Avg
9.5
11.5
10.8
20.9
23.1
22.3
31.3
33.8
32.93
40.5
45.1
43.3
50.5
57
54.23
Single Row
Configuration
Indicates energized contacts
Indicates thermocouple monitored, energized contacts
193177_Power Report_ Rev 4
11 of 24
5/28/2013
POWER INTEGRITY TEST
REPORT
193177
Revision 4
Base Curve
Derated 20 %
193177 (Crimp)
2 (1x2) Contacts in Series
Part Numbers: MMSS-25-24-L-12.00-D-K-LUS / IPL1-125-01-L-S-K
RT Peak Amp
RT Derated Amp
Measured Current
Current Rating per Contact (30 Deg. Rise, 20% Derated) = 4.0 Amps
65 ° C
65 ° C Peak Amp
10.0
65 ° C Derated Amp
Room Temp= 22.3 C
75 ° C
75 ° C Peak Amp
9.0
75 ° C Derated Amp
Limit
8.4
95 ° C Peak Amp
Maximum Current, Amp per Contact
8.0
95 ° C Derated Amp
95 ° C
Room Temp
7.0
105° C
Limit
6.7
6.0
5.8
5.0
5.0
4.6
4.0
4.0
3.0
2.8
2.3
2.0
Useful
Range
1.0
0.0
20
30
40
50
60
70
80
90
100
110
Ambient Temperature, ° C
193177_Power Report_ Rev 4
12 of 24
5/28/2013
POWER INTEGRITY TEST
REPORT
193177
Revision 4
TEMPERATURE RISE DATA
TWO CONTACTS ENERGIZED
(Degrees Celsius above ambient)
TEST CURRENT
AMPS
Sample 4
Sample 5
Sample 6
3.15
12.2
12.9
12.2
4.46
23.8
25.1
23.5
5.46
35.1
37.3
35
6.3
45.9
49.4
46.7
7.05
57.2
61.4
58.8
Min
Max
Avg
12.2
12.9
12.43
23.5
25.1
24.13
35
37.3
35.8
45.9
49.4
47.33
57.2
61.4
59.13
Indicates energized contacts
Indicates thermocouple monitored, energized contacts
193177_Power Report_ Rev 4
13 of 24
5/28/2013
POWER INTEGRITY TEST
REPORT
193177
Revision 4
Base Curve
Derated 20 %
193177 (Crimp)
3 (1x3) Contacts in Series
Part Numbers: MMSS-25-24-L-12.00-D-K-LUS / IPL1-125-01-L-S-K
RT Peak Amp
RT Derated Amp
Measured Current
65 ° C
Current Rating per Contact (30 Deg. Rise, 20% Derated) = 3.4 Amps
65 ° C Peak Amp
9.0
65 ° C Derated Amp
Room Temp= 23.3 C
75 ° C
75 ° C Peak Amp
8.0
75 ° C Derated Amp
Maximum Current, Amp per Contact
Limit
95 ° C Peak Amp
7.2
7.0
95 ° C Derated Amp
95 ° C
Room Temp
6.0
5.8
105° C
Limit
5.0
5.0
4.0
4.0
4.3
3.4
3.0
2.4
2.0
2.0
Useful Range
1.0
0.0
20
30
40
50
60
70
80
90
100
110
Ambient Temperature, ° C
193177_Power Report_ Rev 4
14 of 24
5/28/2013
POWER INTEGRITY TEST
REPORT
193177
Revision 4
TEMPERATURE RISE DATA
THREE CONTACTS ENERGIZED
(Degrees Celsius above ambient)
TEST CURRENT
AMPS
Sample 7
Sample 8
Sample 9
2.92
14.4
14.2
14.4
4.12
27.9
28
28.3
5.05
40.8
41.2
41.3
5.84
54.7
54.1
54.3
6.52
67.9
66.8
67.7
Min
Max
Avg
14.2
14.4
14.33
27.9
28.3
28.07
40.8
41.3
41.1
54.1
54.7
54.37
66.8
67.9
67.47
Indicates energized contacts
Indicates thermocouple monitored, energized contacts
193177_Power Report_ Rev 4
15 of 24
5/28/2013
POWER INTEGRITY TEST
REPORT
193177
Revision 4
Base Curve
Derated 20 %
193177 (Crimp)
4 (1x4) Contacts in Series
Part Numbers: MMSS-25-24-L-12.00-D-K-LUS / IPL1-125-01-L-S-K
RT Peak Amp
RT Derated Amp
Measured Current
Current Rating per Contact (30 Deg. Rise, 20% Derated) = 3.2 Amps
65 ° C
65 ° C Peak Amp
65 ° C Derated Amp
Room Temp= 22.8 C
75 ° C
8.0
75 ° C Peak Amp
75 ° C Derated Amp
Limit
7.0
95 ° C Peak Amp
Maximum Current, Amp per Contact
6.8
95 ° C Derated Amp
95 ° C
Room Temp
6.0
105° C
Limit
5.4
5.0
4.7
4.0
4.0
3.8
3.2
3.0
2.3
2.0
1.8
Useful Range
1.0
0.0
20
30
40
50
60
70
80
90
100
110
Ambient Temperature, ° C
193177_Power Report_ Rev 4
16 of 24
5/28/2013
POWER INTEGRITY TEST
REPORT
193177
Revision 4
TEMPERATURE RISE DATA
FOUR CONTACTS ENERGIZED
(Degrees Celsius above ambient)
TEST CURRENT
AMPS
Sample 10
Sample 11
Sample 12
2.45
11.3
11.2
11.3
3.45
21.9
21.5
23.9
4.24
32.7
31.8
35.9
4.89
43
41.7
46.1
5.46
53.1
51.3
56.2
Min
Max
Avg
11.2
11.3
11.27
21.5
23.9
22.43
31.8
35.9
33.47
41.7
46.1
43.6
51.3
56.2
53.53
Indicates energized contacts
Indicates thermocouple monitored, energized contacts
193177_Power Report_ Rev 4
17 of 24
5/28/2013
POWER INTEGRITY TEST
REPORT
193177
Revision 4
Base Curve
Derated 20 %
193177 (Crimp)
25 (All Power) Contacts in Series
Part Numbers: MMSS-25-24-L-12.00-D-K-LUS / IPL1-125-01-L-S-K
RT Peak Amp
RT Derated Amp
Measured Current
Current Rating per Contact (30 Deg. Rise, 20% Derated) = 2.4 Amps
65 ° C
65 ° C Peak Amp
6.0
65 ° C Derated Amp
Room Temp= 22.8 C
75 ° C
75 ° C Peak Amp
75 ° C Derated Amp
5.1
5.0
Limit
95 ° C Peak Amp
Maximum Current, Amp per Contact
95 ° C Derated Amp
95 ° C
Room Temp
105° C
Limit
4.1
4.0
3.5
3.0
3.0
2.8
2.4
2.0
1.6
1.3
1.0
Useful Range
0.0
20
30
40
50
60
70
80
90
100
110
Ambient Temperature, ° C
193177_Power Report_ Rev 4
18 of 24
5/28/2013
POWER INTEGRITY TEST
REPORT
193177
Revision 4
TEMPERATURE RISE DATA
ALL CONTACTS ENERGIZED
(Degrees Celsius above ambient)
TEST CURRENT
AMPS
Sample 13
Sample 14
Sample 15
1.41
7.9
7
8.2
2
14.8
13.9
15.4
2.45
21.1
20.1
22.1
2.83
26.7
26.3
29.1
3.16
32.4
32.1
35.6
Min
Max
Avg
7
8.2
7.7
13.9
15.4
14.7
20.1
22.1
21.1
26.3
29.1
27.37
32.1
35.6
33.37
Indicates energized contacts
Indicates thermocouple monitored, energized contacts
193177_Power Report_ Rev 4
19 of 24
5/28/2013
POWER INTEGRITY TEST
REPORT
193177
Revision 4
CURRENT CYCLING VS. TEMPERATURE RISE
44
TEMPERATURE RISE
(Degrees C above Ambient)
42
40
38
36
34
Max Rise
32
30
28
26
24
22
0
100
200
300
400
500
NUMBER OF CURRENT CYCLES
TEMPERATURE RISE DATA
ALL CONTACTS ENERGIZED
(Degrees Celsius above ambient)
Min
Max
Avg
193177_Power Report_ Rev 4
INITIAL
50 CYCLES
100 CYCLES
200 CYCLES
500 CYCLES
29.9
33.8
31.7
29.7
33.9
31.6
29.7
33.7
31.6
29.6
33.4
31.4
29.4
32.9
31.3
20 of 24
5/28/2013
POWER INTEGRITY TEST
REPORT
193177
Revision 4
CURRENT CYCLING VS. CONTACT RESISTANCE
CONTACT RESISTANCE @ RATED
CURRENT (milli-Ohms)
70
68
66
64
62
60
58
Max Res
56
54
52
50
48
46
44
0
100
200
300
400
500
NUMBER OF CURRENT CYCLES
CONTACT RESISTANCE DATA
ALL CONTACTS ENERGIZED
(m)
Min
Max
Avg
193177_Power Report_ Rev 4
INITIAL
50 CYCLES
100 CYCLES
200 CYCLES
500 CYCLES
36.58
57.2
45.58
37.23
56.84
45.49
37.2
57.26
45.66
37.1
57.36
45.75
37.06
57.57
45.77
21 of 24
5/28/2013
POWER INTEGRITY TEST
REPORT
193177
Revision 4
CURRENT CYCLING VS. VOLTAGE DROP
VOLTAGE DROP @ RATED CURRENT
(milli-Volts)
189
186
183
180
177
174
171
Max Volt
168
165
162
159
156
153
150
0
100
200
300
400
500
NUMBER OF CURRENT CYCLES
VOLTAGE DROP DATA
ALL CONTACTS ENERGIZED
(MV)
Min
Max
Avg
193177_Power Report_ Rev 4
INITIAL
50 CYCLES
100 CYCLES
200 CYCLES
500 CYCLES
109.73
171.6
136.74
111.69
170.51
136.47
111.6
171.78
136.97
111.3
172.07
137.25
111.19
172.7
137.3
22 of 24
5/28/2013
POWER INTEGRITY TEST
REPORT
193177
Revision 4
EQUIPMENT AND CALIBRATION SCHEDULES
Equipment #: MO-10
Description: Model 2750 Multimeter/Switch System (Integra Series)
Manufacturer: Keithly
Model: 2750
Serial #: 1215161
Accuracy: See Manual
… Last Cal:10/18/2011, Next Cal: 10/18/2012
Equipment #: MO-09
Description: Model 2750 Multimeter/Switch System (Integra Series)
Manufacturer: Keithly
Model: 2750
Serial #: WDC-874817
Accuracy: See Manual
… Last Cal: 9/30/2011, Next Cal: 9/30/2012
Equipment #: PS-09
Description: 60V 50 A DC Power Supply-AutoRanging SO
Manufacturer: Hewlett Packard/Agilent
Model: HP 6032A
Serial #: US38322853
Accuracy: See Manual
Equipment #: PS-04
Description: 60V 50 A DC Power Supply-AutoRanging SO
Manufacturer: Hewlett Packard/Agilent
Model: AT-6032A
Serial #: MY41001186
Accuracy: See Manual
Equipment #: RS-01
Description: Shunt
Manufacturer: EMPRO
Model: HA5050
Serial #: HA5050
Accuracy: ± 0.25% RDG
… Last Cal: 5/30/2012 Next Cal: 5/30/2013
Equipment #: RS-04
Description: Shunt
Manufacturer: EMPRO
Model: HA5050
Serial #: HA5050
Accuracy: ± 0.25% RDG
… Last Cal: 5/30/2012, Next Cal: 5/30/2013
193177_Power Report_ Rev 4
23 of 24
5/28/2013
POWER INTEGRITY TEST
REPORT
193177
Revision 4
Equipment #: TC111307-(TCS-005-048)
Description: Calibrated Thermocouples
Manufacturer: Samtec, Inc.
Model:
Serial #:
Accuracy:
… Last Cal: 5/16/2012, Next Cal: 5/16/2013
193177_Power Report_ Rev 4
24 of 24
5/28/2013