Data Sheets - Skyworks Solutions, Inc.

PRELIMINARY DATA SHEET
SKY77433 Front-End Module for WCDMA / HSDPA / HSUPA
(Tx 1920-1980 MHz), (Rx 2110-2170 MHz)
Applications
Description
• Digital cellular (WCMDA)
handsets
The SKY77433 Front-End Module (FEM) is a fully matched, 16-pad surface mount module developed
for WCDMA applications. Small and efficient, this WCDMA FEM integrates the interstage filter, the
input matching, the power amplifier, the output matching, the power detection, and the duplexer into
a single 7 mm x 4 mm x 1.05 mm package.
Features
• High Speed Downlink
Packet Access (HSDPA)
• High Speed Uplink Packet
Access (HSUPA)
• Low quiescent current
- 20 mA
• Low current consumption
- 500 mA
• Integrated Power Detector
• 16-pad package
• Small profile
- 4 mm x 7 mm x 1.05 mm
• Low voltage
- 3.1 V to 4.45 V
The SKY77433 meets the stringent spectral requirements of HSDPA standards up to 25.2 dBm output
power. The FEM incorporates an InGaP HBT PA and contains circuitry to optimize power detector
performance. Different control pads are available to enhance the performance of the FEM at different
power levels.
Integration of the RF front-end greatly simplifies the design of the handset radio as all critical
matching between the interstage filter, PA, power detection, and duplexer is optimized within the
module. By optimizing the efficiency of the InGaP HBT PA MMIC and reducing the RF loss between
the integrated components, this FEM achieves current as low as 500 mA at maximum output power
(25.2 dBm) that significantly improves the talk time of the WCDMA handset. This small package uses
Skyworks’ low cost, multi-laminate substrate technology and is approximately half the size of
individually packaged component solutions. The SKY77433 front-end module can save handset
designers significant board space and design-cycle time.
• Digital enable pad
• Highly integrated, user
friendly solution
• InGaP HBT
• Integrated interstage filter
and duplexer
• Supports low collector
voltage operation
• Requires few external
components
Figure 1. Functional Block Diagram
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
200595B • Skyworks Proprietary and Confidential Information. • Products and product information are subject to change without notice. • December 8, 2008
1
PRELIMINARY DATA SHEET
SKY77433 FRONT-END MODULE FOR WCDMA / HSDPA / HSUPA
TX (1920-1980 MHz), RX (2110-2170 MHz)
Electrical Specifications
The following tables list the electrical characteristics of the
SKY77433 Front-End Module for WCDMA. Table 1 lists the
absolute maximum ratings; Table 2 specifies the recommended
operating conditions necessary for achieving the electrical
performance listed in Table 3 and Table 4 through Table 7
specifies the standard test configurations in WCDMA, HSDPA, and
HSUPA modes, respectively. Table 8 lists parameters specific to
power detection performance over recommended operating
conditions, including mismatch at the module antenna port up to
a VSWR of 2.5:1 for all phase angles. Table 9 shows nominal
duplexer performance.
Table 1. Absolute Maximum Ratings 1
Parameter
Symbol
RF Input Power
PIN
Supply Voltages
No RF
Minimum
Nominal
Maximum
Unit
—
—
10.0
dBm
3.4
6.0
Volt
VCC1, VCC2, VBIAS
3.4
4.7
Volt
Bias Control Voltage
With RF
VCONT
—
—
2.7
Volt
Mode Control Voltage
VMODE
—
—
3.0
Volts
Enable Control Voltage
Temperatures
VEN
—
—
3.0
Volt
Operating
TCASE
–20
+25
+110
°C
Storage
TSTG
–55
—
+125
Nominal
Maximum
1 No damage assuming only one parameter at a time is set to limit with all other parameters set at nominal values.
Table 2. Recommended Operating Conditions
Parameter
Symbol
Minimum
Unit
Tx Channel Center Frequency
FTX
1922.4
1950.0
1977.6
MHz
Rx Channel Center Frequency
FRX = FTX + 190
MHz
2112.4
2140.0
2167.6
MHz
Supply Voltages
VCC1, VCC2
3.1 1
3.4
4.45
Volt
VBIAS
3.1
3.4
4.45
VCONT
0.5
—
1.9
Volt
Volt
Bias Control Voltage
Mode Control
Enable Control Setting
Low Power Mode (LPM)
VMOD_L
1.5
1.8
2.85
High Power Mode (HPM)
VMOD_H
0.0
0.0
0.56
Disabled
VEN_L
0.0
0.0
0.56
Enabled
VEN_H
1.5
1.8
2.85
TCASE
–20
+25
+85
Operating Temperature
1 For VCC < 3.4 V, maximum output power = PMAX2
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
2
December 8, 2008 • Skyworks Proprietary and Confidential Information. • Products and product information are subject to change without notice. • 200595B
Volt
°C
SKY77433 FRONT-END MODULE FOR WCDMA / HSDPA / HSUPA
TX (1920-1980 MHz), RX (2110-2170 MHz)
PRELIMINARY DATA SHEET
Table 3. Electrical Specifications for Nominal Operating Conditions 1 (1 of 2)
WCDMA (Wide Band Code Division Multiple Access)
Parameter
Symbol
Current Consumption
Harmonic Suppression
Maximum
Unit
dBm
16.0
—
—
PMAX2 2
VCC ≥ 3.1 V
HPM
24.4
—
—
PMAX1 2
HPM
25.2
—
—
Mid-Power
GMID
LPMPMID
11.0
—
23.0
High Power
GHIGH
PMAX1
19.5
—
28.5
Mid-Power
ICC
LPM
PMID
—
—
55
PMAX1
—
—
500
Mid-Power
PAE_MID
LPM
PMID
5.3
—
—
High Power
PAE_HIGH
PMAX1
19.5
—
—
Error Vector Magnitude
Adjacent Channel Leakage Ratio 3
Typical
VCC ≥ 3.1 V
HPM, LPM
High Power
Power Added Efficiency
Minimum
PMID
Linear Output Power
Gain
Conditions
EVM
—
5 MHz
ACLR1
—
10 MHz
ACLR2
Second
2ƒOƒ
Third
3ƒOƒ
PMAX1
dB
mA
%
5
%
dBc
—
–40
—
—
–54
—
—
—
–33
—
—
–33
dBm
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
200595B • Skyworks Proprietary and Confidential Information. • Products and product information are subject to change without notice. • December 8, 2008
3
PRELIMINARY DATA SHEET
SKY77433 FRONT-END MODULE FOR WCDMA / HSDPA / HSUPA
TX (1920-1980 MHz), RX (2110-2170 MHz)
Table 3. Electrical Specifications for Nominal Operating Conditions 1 (2 of 2)
[continued] WCDMA (Wide Band Code Division Multiple Access)
Parameter
Tx Noise Power in Rx Band
Symbol
Conditions
Minimum
Typical
Maximum
Unit
dBm
NRx1
PMAX1
869–894 MHz
RBW = 3.84 MHz
—
—
–61
NRx2
PMAX1
1575.42 MHz
RBW = 2.046 MHz
—
—
–100
NRx3
PMAX1
1884.5–1879.9 MHz
RBW = 3.84 MHz
—
—
–61
NRx4
PMAX1
2110–2170 MHz
RBW = 3.84 MHz
—
—
–114
NRx5
PMAX1
2400–2483.5 MHz
RBW = 1.0 MHz
—
—
–90
NRx6
PMAX1
921–925 MHz
RBW = 100 kHz
—
—
–61
NRx7
PMAX1
925–935 MHz
RBW = 2.046 MHz
—
—
–61
NRx8
PMAX1
1805–1881 MHz
RBW = 3.84 MHz
—
—
–72
NRx9
PMAX1
1893.5–1919.6 MHz
RBW = 3.84 MHz
—
—
–42
Input Voltage Standing Wave Ratio
VSWR
—
—
—
2:1
Quiescent Current
ICQ
—
—
—
25
Control Current
ICONT
—
—
—
1
mA
Digital Enable Current
IEN
—
—
—
1
mA
Leakage Current
ILEAK
VCC1, VCC2, VBIAS = 4.45 V
VCONT = 0 V
VEN = 0 V
VMODE = 0 V
—
—
20
μA
Stability (spurious output)
S
8:1 VSWR, all phases
—
—
–65
dBc
Ruggedness – no damage 4
Ru
10:1
—
—
—
1
Unless otherwise specified: VCC = 3.4 V, Temp. = 25 °C.
2
For STC1 WCDMA, STC2 HSDPA, and STC3 HSUPA modes test conditions. For STC4 HSUPA, power backoff = 2.6 dB.
3
ACLR is specified per 3GPP as the ratio of in-band power to adjacent power, both measured in 3.84 MHz bandwidth at specified offsets.
4
All phases, time = 10 seconds, continuous WCDMA/HSDPA modulated signal, VCC = 4.7 V, PO = PMAX1 + 1.5 dB, PIN_MAX = +10 dBm.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
4
December 8, 2008 • Skyworks Proprietary and Confidential Information. • Products and product information are subject to change without notice. • 200595B
mA
SKY77433 FRONT-END MODULE FOR WCDMA / HSDPA / HSUPA
TX (1920-1980 MHz), RX (2110-2170 MHz)
PRELIMINARY DATA SHEET
Table 4. Standard Test Configuration – STC1 WCDMA Mode
Parameter
Level
Spread Code Spread Factor
I/Q
βc
βd
βhs
βec
βed
Relative Power (dB)
DPCCH
15 kbps
0
256
Q
8/15
—
—
—
—
–6.547
DPDCH
60 kbps
16
64
I
—
15/15
—
—
—
–1.087
Level
Spread Code
Spread Factor
I/Q
βc
βd
βhs
βec
βed
Relative Power (dB)
DPCCH
15 kbps
0
256
Q
12/15
—
—
—
—
–7.095
DPDCH
60 kbps
16
64
I
—
15/15
—
—
—
–5.157
HS-DPDCCH
15 kbps
64
256
Q
—
—
24/15
—
—
–3.012
Table 5. Standard Test Configuration – STC2 HSDPA Mode
Parameter
Table 6. Standard Test Configuration – STC3 HSUPA Mode
Parameter
Level
Spread Code Spread Factor
I/Q
βc
βd
βhs
βec
βed
Relative Power (dB)
DPCCH
15 kbps
0
256
Q
8/15
—
—
—
—
–19.391
DPDCH
960 kbps
1
4
I
—
15/15
—
—
—
–13.931
HS-DPCCH
15 kbps
64
256
Q
—
—
8/15
—
—
–19.391
E-DPCCH
15 kbps
1
256
I
—
—
—
10/15
—
–17.338
E-DPDCH
960 kbps
2
4
I
—
—
—
—
71.5/15
–0.371
Table 7. Standard Test Configuration – STC4 HSUPA Mode
Parameter
Level
Spread Code Spread Factor
I/Q
βc
βd
βhs
βec
βed
Relative Power (dB)
DPCCH
15 kbps
0
256
Q
6/15
—
—
—
—
–12.499
DPDCH
960 kbps
1
4
I
—
15/15
—
—
—
–4.540
HS-DPCCH
15 kbps
64
256
Q
—
—
2/15
—
—
–22.041
E-DPCCH
15 kbps
1
256
I
—
—
—
12/15
—
–6.478
E-DPDCH
960 kbps
2
4
I
—
—
—
—
15/15
–4.425
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
200595B • Skyworks Proprietary and Confidential Information. • Products and product information are subject to change without notice. • December 8, 2008
5
PRELIMINARY DATA SHEET
SKY77433 FRONT-END MODULE FOR WCDMA / HSDPA / HSUPA
TX (1920-1980 MHz), RX (2110-2170 MHz)
Table 8. Electrical Specifications for Power Detector
Tx Power Detection
Parameter
Symbol
Detector Power Detect Range
PDET
Detector Output Range
VDET
Conditions
3 dBm ≤ PO ≤ 26 dBm
Minimum
Typical
Maximum
Unit
0.0
—
26.0
dBm
400 (rms)
—
1800 (peak)
mV
Minimum
Typical
Maximum
Unit
—
—
2.0
dB
Table 9. Nominal Duplexer Performance
Antenna to Rx Parameter
Parameter
Symbol
Insertion Loss
ILRx
Conditions
2110 MHz to 2170 MHz
Ripple
Each Rx Frequency
–0.5
—
0.5
dB
Attenuation
DC to 12750 MHz
20
—
—
dB
ARX1
180 MHz to 200 MHz
40
—
—
ARX2
703 MHz to 724 MHz
25
—
—
ARX3
1055 MHz to 1085 MHz
45
—
—
ARX4
1730 MHz to 1790 MHz
40
—
—
Tx Band
ARX5
1920 MHz to 1980 MHz
50
—
—
ARX6
2015 MHz to 2025 MHz
23
—
—
ARX7
2025 MHz to 2050 MHz
13
—
—
ARX8
2050 MHz to 2075 MHz
5
—
—
Tx + Rx
ARX9
4030 MHz to 4150 MHz
35
—
—
2Tx + Rx
ARX10
5950 MHz to 6130 MHz
35
—
—
VSWR
—
—
—
2.0:1
Input
—
—
—
30
dBm
—
—
–25
dBm
Tx Power @ Rx Port
1920 MHz to 1980 MHz
PMAX1
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
6
December 8, 2008 • Skyworks Proprietary and Confidential Information. • Products and product information are subject to change without notice. • 200595B
SKY77433 FRONT-END MODULE FOR WCDMA / HSDPA / HSUPA
TX (1920-1980 MHz), RX (2110-2170 MHz)
PRELIMINARY DATA SHEET
Evaluation Board Description
The evaluation board is a platform for testing and interfacing
design circuitry. To accommodate the interface testing of the
SKY77433, the evaluation board schematic and assembly
diagrams are included for preliminary analysis and design. The
basic schematic is shown in Figure 2 for the board assembly in
Figure 3.
Figure 2. Evaluation Board Schematic Diagram
Figure 3. Evaluation Board Assembly Diagram
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
200595B • Skyworks Proprietary and Confidential Information. • Products and product information are subject to change without notice. • December 8, 2008
7
PRELIMINARY DATA SHEET
SKY77433 FRONT-END MODULE FOR WCDMA / HSDPA / HSUPA
TX (1920-1980 MHz), RX (2110-2170 MHz)
Package Dimensions
The SKY77433 is a multi-layer laminate base, overmold
encapsulated modular package designed for surface-mounted
solder attachment to a printed circuit board. Figure 4 is a
mechanical drawing of the pad layout for this package. Figure 5
provides a recommended phone board layout footprint for the FEM
to help the designer attain optimum thermal conductivity, good
grounding, and minimum RF discontinuity for the 50 ohm
terminals.
Figure 4. Dimensional Diagram for 7 x 4 x 1.05 mm, 16-Pad Package (All Views) – SKY77433
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
8
December 8, 2008 • Skyworks Proprietary and Confidential Information. • Products and product information are subject to change without notice. • 200595B
SKY77433 FRONT-END MODULE FOR WCDMA / HSDPA / HSUPA
TX (1920-1980 MHz), RX (2110-2170 MHz)
PRELIMINARY DATA SHEET
Figure 5. Phone PCB Layout Footprint for 7 x 4 mm, 16-Pad Package – SKY77433
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
200595B • Skyworks Proprietary and Confidential Information. • Products and product information are subject to change without notice. • December 8, 2008
9
PRELIMINARY DATA SHEET
SKY77433 FRONT-END MODULE FOR WCDMA / HSDPA / HSUPA
TX (1920-1980 MHz), RX (2110-2170 MHz)
Package Description
Figure 6 shows each pad name and the pad numbering
convention, which starts with pad 1, in the lower left as indicated,
and increments counter-clockwise around the package. Figure 7
illustrates typical case markings.
The SKY77433 is currently qualified for MSL3/260 °C. Care must
be taken when attaching this product, whether it is done manually
or in a production solder reflow environment. If the part is
attached in a reflow oven, the temperature ramp rate should not
exceed 3 °C per second; maximum temperature should not
exceed 260 °C. If the part is manually attached, precaution should
be taken to insure that the part is not subjected to temperatures
exceeding 260 °C for more than 10 seconds. For details on
attachment techniques, precautions, and handling procedures
recommended by Skyworks, please refer to Skyworks Application
Note: PCB Design and SMT Assembly/Rework, Document Number
101752. Additional information on standard SMT reflow profiles
can also be found in the JEDEC Standard J–STD–020.
Production quantities of this product are shipped in the standard
tape-and-reel format. For packaging details, refer to Skyworks
Application Note: Tape and Reel – RF Modules, Document
Number 101568.
Figure 6. SKY77433 16-Pad Configuration – (Top View)
Electrostatic Discharge Sensitivity (ESD)
To avoid ESD damage, both latent and visible, it is very important
that the product assembly and test areas follow the Class 1 ESD
handling precautions listed below.
Figure 7. Typical Case Markings (Top View)
Package Handling Information
Because of its sensitivity to moisture absorption, this device
package is baked and vacuum-packed prior to shipment.
Instructions on the shipping container label must be followed
regarding exposure to moisture after the container seal is broken,
otherwise, problems related to moisture absorption may occur
when the part is subjected to high temperature during solder
assembly.
• Personnel Grounding
- Wrist Straps
- Conductive Smocks, Gloves and Finger Cots
- Antistatic ID Badges
• Protective Workstation
- Dissipative Table Top
- Protective Test Equipment (Properly Grounded)
- Grounded Tip Soldering Irons
- Solder Conductive Suckers
- Static Sensors
• Facility
- Relative Humidity Control and Air Ionizers
- Dissipative Floors (less than 109 Ω to GND)
• Protective Packaging and Transportation
- Bags and Pouches (Faraday Shield)
- Protective Tote Boxes (Conductive Static Shielding)
- Protective Trays
- Grounded Carts
- Protective Work Order Holders
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
10
December 8, 2008 • Skyworks Proprietary and Confidential Information. • Products and product information are subject to change without notice. • 200595B
Ordering Information
Model Number
Manufacturing Part Number
SKY77433
SKY77433
Product Revision
Package
Operating Temperature
MCM 7 x 4 x 1.05 mm
–20 °C to +85 °C
Revision History
Revision
Date
Description
A
August 29, 2007
Initial Issue – Preliminary Information
B
December 8, 2008
Revise: Features list (p1); Tables 1, 3, 8; Figures 2–5
Add: GREEN tag (p1); Tables 4–7
References
Skyworks Application Note: Tape and Reel – RF Modules, Document Number 101568
Skyworks Application Note: PCB Design and SMT Assembly/Rework, Document Number 101752
JEDEC Standard J–STD–020
© 2007–2008 Skyworks Solutions, Inc. All Rights Reserved.
Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by
Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the
information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to
update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes.
No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or
information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions of
Sale.
THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A
PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY
DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS
SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION,
LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGE.
Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury,
death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any
damages resulting from such improper use or sale.
Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of
products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for
applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters.
Skyworks, the Skyworks symbol, “Breakthrough Simplicity,” DCR, Helios, HIP3, Innovation to Go, Intera, iPAC, LIPA, Polar Loop, and System Smart are trademarks or registered trademarks of
Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and names are for identification purposes only, and are the property of their respective owners. Additional
information, including relevant terms and conditions, posted at www.skyworksinc.com, are incorporated by reference.