DATA SHEET
SKY13472-460LF: 0.1-3.0 GHz SP2T Switch
Applications
• WCDMA band and mode switching
• Antenna switch for multimode systems
• 802.11a/b/g/n WLANs
Features
• Broadband frequency range: 0.1 to 3.0 GHz
• Low insertion loss: 0.45 dB @ 2.5 GHz
• High isolation: 30 dB up to 2.5 GHz
• No external DC blocking capacitors required
• Positive low voltage control: VCTL = 1.65 to 3.00 V,
VDD = 2.5 to 4.8 V
• Small, QFN (12-pin, 2 x 2 mm) package (MSL1, 260 °C per
JEDEC J-STD-020)
Figure 1. SKY13472-460LF Block Diagram
Description
The SKY13472-460LF is a CMOS silicon-on-insulator (SOI),
single-pole, double-throw (SP2T) switch. The high linearity
performance and low insertion loss makes the device an ideal
choice for WCDMA handset and data card applications.
The SKY13472-460LF SP2T switch is provided in a compact Quad
Flat No-Lead (QFN) 2 x 2 mm package. A functional block diagram
is shown in Figure 1. The pin configuration and package are
shown in Figure 2. Signal pin assignments and functional pin
descriptions are provided in Table 1.
Figure 2. SKY13472-460LF Pinout – 12-Pin QFN
(Top View)
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201887C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • May 24, 2013
1
DATA SHEET • SKY13472-460LF SP2T SWITCH
Table 1. SKY13472-460LF Signal Descriptions
Pin #
1
J1
2
3
Description
Pin #
Name
GND
Description
RF port 1.
7
GND
Ground
8
GND
Ground
N/C
No connect. May be grounded with no
change in performance.
9
J2
RF port 2.
4
V1
DC control voltage 1. See Table 4.
10
GND
Ground
5
V2
DC control voltage 2. See Table 4.
11
RFC
RF common (antenna) port.
VDD
DC power supply.
12
GND
Ground
6
Note:
Name
Ground
Exposed pad must be grounded.
Table 2. SKY13472-460LF Absolute Maximum Ratings (Note 1)
Parameter
Symbol
Minimum
Maximum
Units
V
Supply voltage
VDD
2.5
4.8
Control voltage (Note 2)
VCTL
1.65
3.00
V
Input power
PIN
+39
dBm
Storage temperature
TSTG
–40
+125
°C
Operating temperature
TOP
–40
+85
°C
Note 1: Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other
parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device.
Note 2: Any bias voltage applied to the V1 or V2 pins may damage the device if there is no bias voltage also present on the VDD pin. Maximum control voltage cannot exceed VDD.
CAUTION: Although this device is designed to be as robust as possible, Electrostatic Discharge (ESD) can damage this device. This device
must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body
or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times.
Functional Description
The SKY13472-460LF includes an internal negative voltage
generator and decoder that eliminate the need for external DC
blocking capacitors on the RF ports. No external components are
required for proper operation. DC decoupling capacitors may be
added on the VDD and control lines if necessary.
Switching is controlled by two control voltage inputs, V1 and V2.
Depending on the logic voltage level applied to the control pins,
the RFC (RF common) pin is connected to one of two switched RF
outputs (J1 or J2) through a low insertion path, while the path
between the RFC pin and the other RF pins is in a high isolation
state.
to logic low for at least 20 μs. When exiting shutdown mode, the
switch as a 10.5 μs startup time before switching occurs.
Electrical and Mechanical Specifications
The absolute maximum ratings of the SKY13472-460LF are
provided in Table 2. Electrical specifications are provided in
Table 3.
The state of the SKY13472-460LF is determined by the logic
provided in Table 4.
Typical performance characteristics of the SKY13472-460LF are
illustrated in Figures 3 through 5.
Shutdown mode is enabled by connecting all control pins to logic
low. This mode reduces the overall current consumption of the
device to 5 μA, typical. To prevent the switch from accidentally
entering shutdown mode during switching, all states must be set
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
2
May 24, 2013 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201887C
DATA SHEET • SKY13472-460LF SP2T SWITCH
Table 3. SKY13472-460LF Electrical Specifications (Note 1)
(VDD = 2.3 V to 4.8 V, V1 = V2 = 0 to 1.8 V, TOP = +25 °C, PIN = 0 dBm, Characteristic Impedance [ZO] = 50 Ω, Unless Otherwise Noted)
Parameter
Symbol
Test Condition
Min
Typical
Max
Units
0.30
0.35
0.40
0.45
0.55
0.60
dB
dB
dB
RF Specifications
Insertion loss
IL
0.8 to 1.0 GHz
1.0 to 2.2 GHz
2.2 to 3.0 GHz
Isolation
ISO
0.8 to 1.0 GHz
1.0 to 2.2 GHz
2.2 to 3.0 GHz
Return loss
|S11|
0.8 to 3.0 GHz
3 Order Input Intercept Point
IIP3
0.8 to 3.0 GHz,
ΔF = 1 MHz,
PIN = +20 dBm/tone
Input 0.1 dB compression point
P0.1dB
2nd harmonic
3rd harmonic
40
33
30
dB
dB
dB
22
dB
+68
dBm
0.8 to 3.0 GHz,
RFC to J1 and J2
+39
dBm
2fo
0.8 to 3.0 GHz,
PIN = +26 dBm
+85
dBc
3fo
0.8 to 3.0 GHz,
PIN = +26 dBm
+85
dBc
Switching on time
50% VCTL to 10/90% RF
1600
ns
Switching off time
50% VCTL to 90/10% RF
1600
ns
Startup time
Shutdown state to any RF
switch state
20
μs
rd
35
28
25
+60
DC Specifications
Control voltage:
High
Low
VCTL_HIGH
VCTL_LOW
1.65
0
Supply voltage
VDD
2.5
Supply current
IDD
VDD = 3.5 V
60
μA
Control current
Ictl
V1 = V2 = 1.8 V
2
μA
Shutdown mode supply current
Ioff
VDD = 3.5 V,
V1 = V2 = 0 V
5
μA
1.80
3.00 (Note 2)
0.4
V
V
4.8
V
Note 1: Performance is guaranteed only under the conditions listed in this Table.
Note 2: Control voltage should not exceed supply voltage.
Table 4. SKY13472-460LF Truth Table
Note:
V1
(Pin 4)
V2
(Pin 5)
State
0
0
Shutdown
1
0
RFC to J2
0
1
RFC to J1
1 = 1.65 to 3.00 V; 0 = 0 to 0.4 V. Any state other than described in this Table places the switch into an undefined state.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201887C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • May 24, 2013
3
DATA SHEET • SKY13472-460LF SP2T SWITCH
Typical Performance Characteristics
(VDD = 2.3 V to 4.8 V, V1 = V2 = 0 to 1.8 V, TOP = +25 °C, PIN = 0 dBm, Characteristic Impedance [ZO] = 50 Ω, Unless Otherwise Noted)
Figure 3. Typical Insertion Loss vs Frequency
Figure 4. Typical Isolation vs Frequency
(RFC to J1 Insertion Loss State)
Figure 5. Typical Isolation vs Frequency
(RFC to J2 Insertion Loss State)
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
4
May 24, 2013 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201887C
DATA SHEET • SKY13472-460LF SP2T SWITCH
Evaluation Board Description
Package and Handling Information
The SKY13472-460LF Evaluation Board is used to test the
performance of the SKY13472-460LF SP2T Switch. The board is
made from a two-layer construction with ½ oz. copper cladding
on top and bottom. The first layer material is 12-mil Rogers
4003C. The second layer material is 49-mil of FR4 for a total
board thickness of about 62 mils. The impedance of all RF traces
is 50 Ω.
Instructions on the shipping container label regarding exposure to
moisture after the container seal is broken must be followed.
Otherwise, problems related to moisture absorption may occur
when the part is subjected to high temperature during solder
assembly.
An Evaluation Board schematic diagram is provided in Figure 6.
An assembly drawing for the Evaluation Board is shown in
Figure 7.
Package Dimensions
The PCB layout footprint for the SKY13472-460LF is provided in
Figure 8. Typical case markings are shown in Figure 9. Package
dimensions for the 12-pin QFN are shown in Figure 10, and tape
and reel dimensions are provided in Figure 11.
THE SKY13472-460LF is rated to Moisture Sensitivity Level 1
(MSL1) at 260 °C. It can be used for lead or lead-free soldering.
For additional information, refer to the Skyworks Application Note,
Solder Reflow Information, document number 200164.
Care must be taken when attaching this product, whether it is
done manually or in a production solder reflow environment.
Production quantities of this product are shipped in a standard
tape and reel format.
Figure 6. SKY13472-460LF Evaluation Board Schematic
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201887C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • May 24, 2013
5
DATA SHEET • SKY13472-460LF SP2T SWITCH
Figure 7. SKY13472-460LF Evaluation Board Assembly Diagram
Figure 8. SKY13472-460LF PCB Layout Footprint
(Top View)
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
6
May 24, 2013 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201887C
DATA SHEET • SKY13472-460LF SP2T SWITCH
Figure 9. Typical Case Markings
(Top View)
Figure 10. SKY13472-460LF 12-Pin QFN Package Dimensions
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201887C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • May 24, 2013
7
DATA SHEET • SKY13472-460LF SP2T SWITCH
Figure 11. SKY13472-460LF Tape and Reel Dimensions
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
8
May 24, 2013 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201887C
DATA SHEET • SKY13472-460LF SP2T SWITCH
Ordering Information
Model Name
SKY13472-460LF SP2T Switch
Manufacturing Part Number
SKY13472-460LF
Evaluation Board Part Number
SKY13472-460LF-EVB
Copyright © 2012, 2013 Skyworks Solutions, Inc. All Rights Reserved.
Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by
Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the
information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to
update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes.
No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or
information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions of
Sale.
THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A
PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY
DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS
SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION,
LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGE.
Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury,
death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any
damages resulting from such improper use or sale.
Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of
products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for
applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters.
Skyworks, the Skyworks symbol, and “Breakthrough Simplicity” are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands
and names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com,
are incorporated by reference.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201887C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • May 24, 2013
9