SKYWORKS SKY13392

DATA SHEET
SKY13392-359LF: 0.02-4.0 GHz High Isolation SP4T
Absorptive Switch With Decoder
Applications
• GSM/CDMA/WCDMA/LTE cellular infrastructure
• Test and measurement systems
• Military communications
Features
• Broadband frequency range: 0.02 GHz to 4.0 GHz
• Low insertion loss: 1.0 dB @ 2 GHz
• Typical isolation: 54 dB @ 2 GHz
• Positive voltage control: 0/3 V to 0/5 V
• Isolated ports are absorptive from 500 MHz to 4 GHz
• Small, QFN (16-pin, 4 x 4 mm) package (MSL1, 260 °C per
JEDEC J-STD-020)
Figure 1. SKY13392-359LF Block Diagram
Description
The SKY13392-359LF is a symmetrical, single-pole, four-throw
(SP4T) switch. The switch is intended for GSM/CDMA/WCDMA/LTE
cellular infrastructure applications. The impedance of the RF ports
in isolation is 50 Ω at frequencies above 500 MHz.
The SKY13392-359LF is manufactured using Skyworks state-ofthe-art GaAs pHEMT process. The SKY13392-359LF features
integrated logic that uses only two control lines for switch
operation.
The SKY13392-359LF SP4T switch is provided in a compact Quad
Flat No-Lead (QFN) 4 x 4 mm package. A functional block diagram
is shown in Figure 1. The pin configuration and package are
shown in Figure 2. Signal pin assignments and functional pin
descriptions are provided in Table 1.
Figure 2. SKY13392-359LF Pinout – 16-Pin QFN
(Top View)
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201854B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 2, 2012
1
DATA SHEET • SKY13392-359LF SP4T SWITCH
Table 1. SKY13392-359LF Signal Descriptions
Pin #
Name
Description
Pin #
Name
Description
1
RF4
RF output 4. A DC blocking capacitor is required.
9
RF2
RF output 2. A DC blocking capacitor is required.
2
GND
Ground
10
GND
Ground
3
GND
Ground
11
GND
Ground
4
RF3
RF output 3. A DC blocking capacitor is required.
12
RF1
RF output 1. A DC blocking capacitor is required.
5
GND
Ground
13
GND
Ground
6
VDD
Supply voltage input
14
GND
Ground
7
VC1
Control signal 1. See Table 4.
15
RFC
RF common port. A DC blocking capacitor is
required.
8
VC2
Control signal 2. See Table 4.
16
GND
Ground
Table 2. SKY13392-359LF Absolute Maximum Ratings
Parameter
Symbol
Minimum
Maximum
Units
Supply voltage
VDD
5.5
V
Input power
PIN
+32
dBm
Control voltage (VC1, VC2)
VCTL
VDD
V
Operating temperature
TOP
–40
+85
°C
Storage temperature
TSTG
–40
+125
°C
Note:
Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other
parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device.
CAUTION: Although this device is designed to be as robust as possible, Electrostatic Discharge (ESD) can damage this device. This device
must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body
or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times.
Functional Description
Electrical and Mechanical Specifications
The SKY13392-359LF is comprised of a CMOS decoder that
enables two TTL-compatible DC lines to control four RF ports. The
decoder is internally connected to a GaAs pHEMT RF switch.
Depending on the logic voltage level applied to the control pins,
the RFC pin is connected to one of four switched RF outputs (RF1,
RF2, RF3, or RF4) by a low insertion loss path, while maintaining a
high isolation path to the alternate port.
The absolute maximum ratings of the SKY13392-359LF are
provided in Table 2. Electrical specifications are provided in
Table 3.
The CMOS decoder should have VDD applied before a logic high is
applied to one of the control lines.
The state of the SKY13392-359LF is determined by the logic
provided in Table 4.
Typical performance characteristics of the SKY13392-359LF are
illustrated in Figures 3 through 9.
The recommended startup sequence is:
Step 1: Apply VDD.
Step 2: Apply VC1 and VC2
Step 3: Apply RF input.
The device must be turned off in the reverse order.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
2
October 2, 2012 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201854B
DATA SHEET • SKY13392-359LF SP4T SWITCH
Table 3. SKY13392-359LF Electrical Specifications (1 of 2) (Note 1)
(VDD = 5 V, VC1 = VC2 = VDD, TOP = +25 °C, All Unused RF Ports are Terminated in a 50 Ω Load, Unless Otherwise Noted)
Parameter
Symbol
Test Condition
Min
Typical
Max
Units
0.9
1.0
1.1
1.5
1.1
1.2
1.3
1.9
dB
dB
dB
dB
RF Specifications
Insertion loss
IL
0.02 to 1.0 GHz
1.0 to 2.0 GHz
2.0 to 2.5 GHz
2.5 to 4.0 GHz
Isolation
ISO
0.02 to 1.0 GHz
1.0 to 2.0 GHz
2.0 to 2.5 GHz
2.5 to 4.0 GHz
Return loss (insertion loss state) (Note 2)
|S11|
55
50
48
40
60
54
51
46
dB
dB
dB
dB
0.02 to 2.5 GHz, all RF
ports
15
dB
2.5 to 4.0 GHz
9
dB
Return loss (isolation state)
|S22|
0.5 to 4.0 GHz
14
dB
1 dB Input Compression Point
P1dB
0.3 to 4.0 GHz, VDD = 5 V
+30
dBm
3rd Order Input Intercept Point
IIP3
Two tones, +7 dBm per
tone, 0.3 to 4.0 GHz,
1 MHz spacing
+47
dBm
Switching speed
TRISE, TFALL
10/90% RF rise/fall time
21
ns
TON, TOFF
50 % VCTL to 10/90%
on/off time
125
ns
DC/Control Specifications
Supply voltage
VDD
Supply current
IDD
Control voltage (VC1, VC2):
High
Low
VCTL
Control current:
High
Low
ICTL
3
5
V
μA
350
2.5
3.0
0
VDD
0.8
V
V
μA
μA
5
5
Note 1: Performance is guaranteed only under the conditions listed in this Table.
Note 2: Return loss in the insertion loss state is dependent on the value of DC blocking capacitors.
Table 4. SKY13392-359LF Truth Table
Note:
State
VC1
(Pin 7)
VC2
(Pin 8)
RF Path
1
VLOW
VLOW
RFC to RF1
2
VLOW
VHIGH
RFC to RF2
3
VHIGH
VLOW
RFC to RF3
4
VHIGH
VHIGH
RFC to RF4
VHIGH = 2.5 V to VDD
VLOW = 0 to 0.8 V
Any state other than described in this Table places the switch into an undefined state.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201854B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 2, 2012
3
DATA SHEET • SKY13392-359LF SP4T SWITCH
Typical Performance Characteristics
(VDD = 5 V, CTRL1 = CTRL2 = VDD, TOP = +25 °C, PIN = 0 dBm, Blocking Capacitors = 100 pF, Unless Otherwise Noted)
Figure 3. Insertion Loss vs Frequency
Figure 4. Isolation vs Frequency
(RFC to RF1 “On”)
Figure 5. Isolation vs Frequency
(RFC to RF2 “On”)
Figure 6. Isolation vs Frequency
(RFC to RF3 “On”)
Figure 7. Isolation vs Frequency
(RFC to RF4 “On”)
Figure 8. Return Loss vs Frequency
(Insertion Loss States)
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
4
October 2, 2012 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201854B
DATA SHEET • SKY13392-359LF SP4T SWITCH
Figure 9. Return Loss vs Frequency
(Isolation States)
Evaluation Board Description
Package and Handling Information
The SKY13392-359LF Evaluation Board is used to test the
performance of the SKY13392-359LF SP4T Switch. An Evaluation
Board schematic diagram is provided in Figure 10. An assembly
drawing for the Evaluation Board is shown in Figure 11.
Instructions on the shipping container label regarding exposure to
moisture after the container seal is broken must be followed.
Otherwise, problems related to moisture absorption may occur
when the part is subjected to high temperature during solder
assembly.
Package Dimensions
The PCB layout footprint for the SKY13392-359LF is provided in
Figure 12. Typical case markings are shown in Figure 13.
Package dimensions for the 16-pin QFN are shown in Figure 14,
and tape and reel dimensions are provided in Figure 15.
THE SKY13392-359LF is rated to Moisture Sensitivity Level 1
(MSL1) at 260 °C. It can be used for lead or lead-free soldering.
For additional information, refer to the Skyworks Application Note,
Solder Reflow Information, document number 200164.
Care must be taken when attaching this product, whether it is
done manually or in a production solder reflow environment.
Production quantities of this product are shipped in a standard
tape and reel format.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201854B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 2, 2012
5
DATA SHEET • SKY13392-359LF SP4T SWITCH
Figure 10. SKY13392-359LF Evaluation Board Schematic
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
6
October 2, 2012 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201854B
DATA SHEET • SKY13392-359LF SP4T SWITCH
Figure 11. SKY13392-359LF Evaluation Board Assembly Diagram
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201854B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 2, 2012
7
DATA SHEET • SKY13392-359LF SP4T SWITCH
Figure 12. SKY13392-359LF PCB Layout Footprint
(Top View)
Figure 13. Typical Case Markings
(Top View)
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
8
October 2, 2012 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201854B
DATA SHEET • SKY13392-359LF SP4T SWITCH
Figure 14. SKY13392-359LF 16-Pin QFN Package Dimensions
Figure 15. SKY13392-359LF Tape and Reel Dimensions
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201854B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 2, 2012
9
DATA SHEET • SKY13392-359LF SP4T SWITCH
Ordering Information
Model Name
SKY13392-359LF SP4T Switch
Manufacturing Part Number
SKY13392-359LF
Evaluation Board Part Number
SKY13392-359LF-EVB
Copyright © 2012 Skyworks Solutions, Inc. All Rights Reserved.
Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by
Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the
information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to
update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes.
No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or
information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions of
Sale.
THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A
PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY
DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS
SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION,
LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGE.
Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury,
death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any
damages resulting from such improper use or sale.
Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of
products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for
applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters.
Skyworks, the Skyworks symbol, and “Breakthrough Simplicity” are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands
and names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com,
are incorporated by reference.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
10
October 2, 2012 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201854B