DATA SHEET SKY13355-374LF: 0.1-6.0 GHz DPDT Switch Applications • Dual-band wireless LANs (802.11 a/b/g/n) • Diversity antenna switching Features • Broadband frequency range: 0.1 to 6.0 GHz • Positive control voltage range: 1.8 to 5.0 V • Low insertion loss: 0.6 dB typical @ 2.5 GHz • High isolation: 23.5 dB typical @ 2.5 GHz • P1dB: +33 dBm typical @ 3 V • Small, MLPD (6-pin, 1.5 x 1.5 mm) Pb-free package (MSL1, 260 °C per JEDEC J-STD-020) Figure 1. SKY13355-374LF Block Diagram Description The SKY13355-374LF is a pHEMT GaAs Double-Pole, DoubleThrow (DPDT) switch designed for 2.4 and 6.0 GHz, dual-band wireless LAN applications. The switch provides high linearity performance, low insertion loss, and high isolation in both frequency bands. Switching is controlled by two voltage inputs (V1 and V2). Depending on the logic voltage level applied to the control pins, the ANT1 and ANT2 pins connect to one of two switched RF outputs (RX or TX) through a low insertion loss path while maintaining a high isolation path to the alternate port. The switch is manufactured in a compact, 1.5 x 1.5 mm, 6-pin exposed pad plastic Micro Leadframe Package Dual (MLPD) package. A functional block diagram is shown in Figure 1. The pin configuration and package are shown in Figure 2. Signal pin assignments and functional pin descriptions are provided in Table 1. Figure 2. SKY13355-374LF Pinout – 6-Pin MLPD (Top View) Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 201341C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 11, 2011 1 DATA SHEET • SKY13355-374LF DPDT SWITCH Table 1. SKY13355-374LF Signal Descriptions Pin # Note: Name Description Pin # Name Description 1 ANT2 Antenna 2 RF port. Must be DC-blocked for proper operation. 4 TX Transmit RF port. Must be DC-blocked for proper operation. 2 V2 DC control voltage 2 5 V1 DC control voltage 1 3 RX Receive RF port. Must be DC-blocked for proper operation. 6 ANT1 Antenna 1 RF port. Must be DC-blocked for proper operation. Exposed backside ground pad must be properly grounded through a low impedance path. Table 2. SKY13355-374LF Absolute Maximum Ratings Parameter Symbol Minimum Typical Maximum Units Control voltage V1, V2 RF input power PIN Storage temperature TSTG –40 +125 °C Operating temperature TOP –40 +85 °C Note: 6 V +34 dBm Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device. CAUTION: Although this device is designed to be as robust as possible, Electrostatic Discharge (ESD) can damage this device. This device must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times. Table 3. SKY13355-374LF Recommended Operating Conditions Parameter Symbol Minimum Frequency f 0.1 Control voltage V1, V2 1.8 Electrical and Mechanical Specifications The absolute maximum ratings of the SKY13355-374LF are provided in Table 2. The recommended operating conditions are specified in Table 3 and electrical specifications are provided in Table 4. Typical 3.0 Maximum Units 6.0 GHz 5.0 V Typical performance characteristics of the SKY13355-374LF are illustrated in Figures 3 through 8. The state of the SKY13355-374LF is determined by the logic provided in Table 5. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 2 October 11, 2011 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201341C DATA SHEET • SKY13355-374LF DPDT SWITCH Table 4. SKY13355-374LF Electrical Specifications (Note 1) (VCTL = 0 V and +3.0 V, TOP = +25 °C, PIN = 0 dBm, Characteristic Impedance [ZO] = 50 Ω, Unless Otherwise Noted) Parameter Symbol Test Condition Min Typical Max Units 0.50 0.60 0.80 0.90 0.55 0.65 0.85 0.95 dB dB dB dB RF Specifications Insertion loss IL ANT1/ANT2 to RX/TX 0.1 to 1.0 GHz 1.0 to 2.5 GHz 2.5 to 4.9 GHz 4.9 to 6.0 GHz Isolation Iso ANT1/ANT2 to RX/TX, ANT1 to ANT2, TX to RX 0.1 to 1.0 GHz 1.0 to 2.5 GHz 2.5 to 4.9 GHz 4.9 to 6.0 GHz 30.0 22.0 15.0 13.0 31.0 23.5 17.0 15.0 dB dB dB dB Return loss (Note 2) |S11| ANT1/ANT2 to RX/TX, 0.1 to 6.0 GHz 20 dB 1 dB Input Compression Point IP1dB 0.1 to 6.0 GHz +33 dBm 0.1 dB Input Compression Point IP0.1dB 0.1 to 6.0 GHz +30 dBm Input IP3 IIP3 PIN = +20 dBm/tone, Δf = 1 MHz, 0.1 to 6.0 GHz +55 dBm 2nd harmonic 2fo PIN = +20 dBm, 0.1 to 6.0 GHz –65 dBc 3rd harmonic 3fo PIN = +20 dBm, 0.1 to 6.0 GHz –75 dBc 50% V1/V2 to 90/10% RF 30 ns 90/10% RF or 10/90% RF 20 ns Switching speed DC Specifications Control voltage: high low V1, V2 Control current ICC 1.8 –0.2 3.0 0 5.0 0.2 5 V V μA Note 1: Performance is guaranteed only under the conditions listed in this Table. Note 2: Lower frequency return loss is dependent on the DC blocking capacitor value. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 201341C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 11, 2011 3 DATA SHEET • SKY13355-374LF DPDT SWITCH Typical Performance Characteristics (VCTL = 0 V and +3.0 V, TOP = +25 °C, PIN = 0 dBm, Characteristic Impedance [ZO] = 50 Ω, Unless Otherwise Noted) Figure 3. Insertion Loss vs Frequency Figure 4. Isolation vs Frequency, ANT2-TX/ANT1-RX Insertion Loss Mode Figure 5. Isolation vs Frequency, ANT2-RX/ANT1-TX Insertion Loss Mode Figure 6. Return Loss vs Frequency, Figure 7. Insertion Loss vs Input Power @ 2.5 GHz and 5.5 GHz Figure 8. P1dB and P0.1dB vs Control Voltage @ 5.5 GHz Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 4 October 11, 2011 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201341C DATA SHEET • SKY13355-374LF DPDT SWITCH Table 5. SKY13355-374LF Truth Table V1 (Pin 5) Note: V2 (Pin 2) ANT1 (Pin 6) to TX (Pin 4) ANT1 (Pin 6) to RX (Pin 3) ANT2 (Pin 1) to TX (Pin 4) ANT2 (Pin 1) to RX (Pin 3) High Low Isolation state Insertion loss state Insertion loss state Isolation state Low High Insertion loss state Isolation state Isolation state Insertion loss state High = +1.8 V to +5 V. Low = –0.2 V to +0.2 V. Evaluation Board Description Package and Handling Information The SKY13355-374LF Evaluation Board is used to test the performance of the SKY13355-374LF SPDT Switch. An Evaluation Board schematic diagram is provided in Figure 9. An assembly drawing for the Evaluation Board is shown in Figure 10. Instructions on the shipping container label regarding exposure to moisture after the container seal is broken must be followed. Otherwise, problems related to moisture absorption may occur when the part is subjected to high temperature during solder assembly. The SKY13355-374LF is rated to Moisture Sensitivity Level 1 (MSL1) at 260 °C. It can be used for lead or lead-free soldering. Package Dimensions The PCB layout footprint for the SKY13355-374LF is provided in Figure 11. Typical case markings are shown in Figure 12. Package dimensions for the 6-pin MLPD are shown in Figure 13, and tape and reel dimensions are provided in Figure 14. Care must be taken when attaching this product, whether it is done manually or in a production solder reflow environment. Production quantities of this product are shipped in a standard tape and reel format. Figure 9. SKY13355-374LF Evaluation Board Schematic Table 6. SKY13355-374LF Evaluation Board Bill of Materials Component Value Size Manufacturer Characteristic CBL 47 pF 0402 Murata GRM Series DC blocking capacitor CBYP 10 pF 0402 Murata GRM Series Decoupling capacitor Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 201341C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 11, 2011 5 DATA SHEET • SKY13355-374LF DPDT SWITCH Figure 10. SKY13355-374LF Evaluation Board Assembly Diagram Figure 11. SKY13355-374LF PCB Layout Footprint (Top View) Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 6 October 11, 2011 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201341C DATA SHEET • SKY13355-374LF DPDT SWITCH Figure 12. Typical Part Markings (Top View) Figure 13. SKY13355-374LF 6-Pin QFN Package Dimensions Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 201341C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 11, 2011 7 DATA SHEET • SKY13355-374LF DPDT SWITCH Figure 14. SKY13355-374LF Tape and Reel Dimensions Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 8 October 11, 2011 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201341C DATA SHEET • SKY13355-374LF DPDT SWITCH Ordering Information Model Name SKY13355-374LF SPDT Switch Manufacturing Part Number SKY13355-374LF Evaluation Board Part Number SKY13355-374LF-EVB Copyright © 2010 Skyworks Solutions, Inc. All Rights Reserved. Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes. No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions of Sale. THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury, death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any damages resulting from such improper use or sale. Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters. Skyworks, the Skyworks symbol, and “Breakthrough Simplicity” are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are incorporated by reference. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 201341C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 11, 2011 9