SKY13355-374LF - Skyworks Solutions, Inc.

DATA SHEET
SKY13355-374LF: 0.1-6.0 GHz DPDT Switch
Applications
• Dual-band wireless LANs (802.11 a/b/g/n)
• Diversity antenna switching
Features
• Broadband frequency range: 0.1 to 6.0 GHz
• Positive control voltage range: 1.8 to 5.0 V
• Low insertion loss: 0.6 dB typical @ 2.5 GHz
• High isolation: 23.5 dB typical @ 2.5 GHz
• P1dB: +33 dBm typical @ 3 V
• Small, MLPD (6-pin, 1.5 x 1.5 mm) Pb-free package (MSL1,
260 °C per JEDEC J-STD-020)
Figure 1. SKY13355-374LF Block Diagram
Description
The SKY13355-374LF is a pHEMT GaAs Double-Pole, DoubleThrow (DPDT) switch designed for 2.4 and 6.0 GHz, dual-band
wireless LAN applications. The switch provides high linearity
performance, low insertion loss, and high isolation in both
frequency bands.
Switching is controlled by two voltage inputs (V1 and V2).
Depending on the logic voltage level applied to the control pins,
the ANT1 and ANT2 pins connect to one of two switched RF
outputs (RX or TX) through a low insertion loss path while
maintaining a high isolation path to the alternate port.
The switch is manufactured in a compact, 1.5 x 1.5 mm, 6-pin
exposed pad plastic Micro Leadframe Package Dual (MLPD)
package.
A functional block diagram is shown in Figure 1. The pin
configuration and package are shown in Figure 2. Signal pin
assignments and functional pin descriptions are provided in
Table 1.
Figure 2. SKY13355-374LF Pinout – 6-Pin MLPD
(Top View)
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201341C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 11, 2011
1
DATA SHEET • SKY13355-374LF DPDT SWITCH
Table 1. SKY13355-374LF Signal Descriptions
Pin #
Note:
Name
Description
Pin #
Name
Description
1
ANT2
Antenna 2 RF port. Must be DC-blocked for
proper operation.
4
TX
Transmit RF port. Must be DC-blocked for
proper operation.
2
V2
DC control voltage 2
5
V1
DC control voltage 1
3
RX
Receive RF port. Must be DC-blocked for
proper operation.
6
ANT1
Antenna 1 RF port. Must be DC-blocked for
proper operation.
Exposed backside ground pad must be properly grounded through a low impedance path.
Table 2. SKY13355-374LF Absolute Maximum Ratings
Parameter
Symbol
Minimum
Typical
Maximum
Units
Control voltage
V1, V2
RF input power
PIN
Storage temperature
TSTG
–40
+125
°C
Operating temperature
TOP
–40
+85
°C
Note:
6
V
+34
dBm
Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other
parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device.
CAUTION: Although this device is designed to be as robust as possible, Electrostatic Discharge (ESD) can damage this device. This device
must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body
or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times.
Table 3. SKY13355-374LF Recommended Operating Conditions
Parameter
Symbol
Minimum
Frequency
f
0.1
Control voltage
V1, V2
1.8
Electrical and Mechanical Specifications
The absolute maximum ratings of the SKY13355-374LF are
provided in Table 2. The recommended operating conditions are
specified in Table 3 and electrical specifications are provided in
Table 4.
Typical
3.0
Maximum
Units
6.0
GHz
5.0
V
Typical performance characteristics of the SKY13355-374LF are
illustrated in Figures 3 through 8.
The state of the SKY13355-374LF is determined by the logic
provided in Table 5.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
2
October 11, 2011 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201341C
DATA SHEET • SKY13355-374LF DPDT SWITCH
Table 4. SKY13355-374LF Electrical Specifications (Note 1)
(VCTL = 0 V and +3.0 V, TOP = +25 °C, PIN = 0 dBm, Characteristic Impedance [ZO] = 50 Ω, Unless Otherwise Noted)
Parameter
Symbol
Test Condition
Min
Typical
Max
Units
0.50
0.60
0.80
0.90
0.55
0.65
0.85
0.95
dB
dB
dB
dB
RF Specifications
Insertion loss
IL
ANT1/ANT2 to RX/TX
0.1 to 1.0 GHz
1.0 to 2.5 GHz
2.5 to 4.9 GHz
4.9 to 6.0 GHz
Isolation
Iso
ANT1/ANT2 to RX/TX,
ANT1 to ANT2, TX to RX
0.1 to 1.0 GHz
1.0 to 2.5 GHz
2.5 to 4.9 GHz
4.9 to 6.0 GHz
30.0
22.0
15.0
13.0
31.0
23.5
17.0
15.0
dB
dB
dB
dB
Return loss (Note 2)
|S11|
ANT1/ANT2 to RX/TX,
0.1 to 6.0 GHz
20
dB
1 dB Input Compression Point
IP1dB
0.1 to 6.0 GHz
+33
dBm
0.1 dB Input Compression Point
IP0.1dB
0.1 to 6.0 GHz
+30
dBm
Input IP3
IIP3
PIN = +20 dBm/tone,
Δf = 1 MHz,
0.1 to 6.0 GHz
+55
dBm
2nd harmonic
2fo
PIN = +20 dBm,
0.1 to 6.0 GHz
–65
dBc
3rd harmonic
3fo
PIN = +20 dBm,
0.1 to 6.0 GHz
–75
dBc
50% V1/V2 to 90/10% RF
30
ns
90/10% RF or 10/90% RF
20
ns
Switching speed
DC Specifications
Control voltage:
high
low
V1, V2
Control current
ICC
1.8
–0.2
3.0
0
5.0
0.2
5
V
V
μA
Note 1: Performance is guaranteed only under the conditions listed in this Table.
Note 2: Lower frequency return loss is dependent on the DC blocking capacitor value.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201341C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 11, 2011
3
DATA SHEET • SKY13355-374LF DPDT SWITCH
Typical Performance Characteristics
(VCTL = 0 V and +3.0 V, TOP = +25 °C, PIN = 0 dBm, Characteristic Impedance [ZO] = 50 Ω, Unless Otherwise Noted)
Figure 3. Insertion Loss vs Frequency
Figure 4. Isolation vs Frequency,
ANT2-TX/ANT1-RX Insertion Loss Mode
Figure 5. Isolation vs Frequency,
ANT2-RX/ANT1-TX Insertion Loss Mode
Figure 6. Return Loss vs Frequency,
Figure 7. Insertion Loss vs Input Power
@ 2.5 GHz and 5.5 GHz
Figure 8. P1dB and P0.1dB vs Control Voltage
@ 5.5 GHz
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
4
October 11, 2011 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201341C
DATA SHEET • SKY13355-374LF DPDT SWITCH
Table 5. SKY13355-374LF Truth Table
V1 (Pin 5)
Note:
V2 (Pin 2)
ANT1 (Pin 6) to
TX (Pin 4)
ANT1 (Pin 6) to
RX (Pin 3)
ANT2 (Pin 1) to
TX (Pin 4)
ANT2 (Pin 1) to
RX (Pin 3)
High
Low
Isolation state
Insertion loss state
Insertion loss state
Isolation state
Low
High
Insertion loss state
Isolation state
Isolation state
Insertion loss state
High = +1.8 V to +5 V. Low = –0.2 V to +0.2 V.
Evaluation Board Description
Package and Handling Information
The SKY13355-374LF Evaluation Board is used to test the
performance of the SKY13355-374LF SPDT Switch. An Evaluation
Board schematic diagram is provided in Figure 9. An assembly
drawing for the Evaluation Board is shown in Figure 10.
Instructions on the shipping container label regarding exposure to
moisture after the container seal is broken must be followed.
Otherwise, problems related to moisture absorption may occur
when the part is subjected to high temperature during solder
assembly.
The SKY13355-374LF is rated to Moisture Sensitivity Level 1
(MSL1) at 260 °C. It can be used for lead or lead-free soldering.
Package Dimensions
The PCB layout footprint for the SKY13355-374LF is provided in
Figure 11. Typical case markings are shown in Figure 12.
Package dimensions for the 6-pin MLPD are shown in Figure 13,
and tape and reel dimensions are provided in Figure 14.
Care must be taken when attaching this product, whether it is
done manually or in a production solder reflow environment.
Production quantities of this product are shipped in a standard
tape and reel format.
Figure 9. SKY13355-374LF Evaluation Board Schematic
Table 6. SKY13355-374LF Evaluation Board Bill of Materials
Component
Value
Size
Manufacturer
Characteristic
CBL
47 pF
0402
Murata GRM Series
DC blocking capacitor
CBYP
10 pF
0402
Murata GRM Series
Decoupling capacitor
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201341C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 11, 2011
5
DATA SHEET • SKY13355-374LF DPDT SWITCH
Figure 10. SKY13355-374LF Evaluation Board Assembly Diagram
Figure 11. SKY13355-374LF PCB Layout Footprint
(Top View)
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
6
October 11, 2011 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201341C
DATA SHEET • SKY13355-374LF DPDT SWITCH
Figure 12. Typical Part Markings
(Top View)
Figure 13. SKY13355-374LF 6-Pin QFN Package Dimensions
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201341C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 11, 2011
7
DATA SHEET • SKY13355-374LF DPDT SWITCH
Figure 14. SKY13355-374LF Tape and Reel Dimensions
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
8
October 11, 2011 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201341C
DATA SHEET • SKY13355-374LF DPDT SWITCH
Ordering Information
Model Name
SKY13355-374LF SPDT Switch
Manufacturing Part Number
SKY13355-374LF
Evaluation Board Part Number
SKY13355-374LF-EVB
Copyright © 2010 Skyworks Solutions, Inc. All Rights Reserved.
Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by
Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the
information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to
update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes.
No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or
information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions of
Sale.
THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A
PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY
DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS
SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION,
LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGE.
Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury,
death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any
damages resulting from such improper use or sale.
Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of
products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for
applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters.
Skyworks, the Skyworks symbol, and “Breakthrough Simplicity” are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands
and names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com,
are incorporated by reference.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201341C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 11, 2011
9