DATA SHEET SKY13374-397LF: 300 kHz to 6.0 GHz SPDT Switch Applications RF1 Dual-band wireless LANs (802.11 a/b/g/n) Diversity antenna switching WCDMA handsets and data cards RF3 RF2 Features Broadband frequency range: 300 kHz to 6.0 GHz Low insertion loss: 0.35 dB @ 1 GHz, 0.8 dB @ 6 GHz No external DC blocking capacitors required Positive low control voltage: 1.65 to 3.0 V (VCTRL), 2.5 to 4.8 V (VBATT) Small, QFN (12-pin, 2 x 2 mm) package (MSL1, 260 C per JEDEC J-STD-020) Decoder V1 V2 VBATT S2304 Figure 1. SKY13374-397LF Block Diagram Description GND RF2 GND Skyworks Green™ products are compliant with all applicable legislation and are halogen-free. For additional information, refer to Skyworks Definition of Green™, document number SQ04-0074. 12 11 10 The high 0.1 dB Input Compression Point (IP0.1dB) and advance proprietary fabrication process enable exceptional WCDMA harmonic and Adjacent Channel Power (ACP) performance. Excellent insertion loss and isolation is maintained over WCDMA bands 1 to 6 and 8 to 11. VBATT RF1 2 8 V2 GND 3 7 V1 5 6 GND 9 RF3 1 GND N/C 4 The SKY13374-397LF is a CMOS Silicon-on-Insulator (SOI) singlepole, double-throw (SPDT) WCDMA band switch. The high linearity performance and low insertion loss achieved by the device makes it an ideal choice for medium to high power WCDMA handset and data card applications. The SKY13374-397LF SPDT switch is provided in a compact Quad Flat No-Lead (QFN) 2 x 2 mm package with 0.5 mm lead pitch for ease of manufacturing. A functional block diagram is shown in Figure 1. The pin configuration and package are shown in Figure 2. Signal pin assignments and functional pin descriptions are provided in Table 1. S2303 Figure 2. SKY13374-397LF Pinout – 12-Pin QFN (Top View) Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 201447K • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 11, 2013 1 DATA SHEET • SKY13374-397LF SPDT SWITCH Table 1. SKY13374-397LF Signal Descriptions Pin # Description 1 N/C No connection 2 RF1 3 GND Pin # Name Description 7 V1 DC control voltage. See Table 4. RF port 1 8 V2 DC control voltage. See Table 4. Ground 9 VBATT DC power supply. 4 GND Ground 10 GND Ground 5 RF3 RF port 3 11 RF2 RF port 2 GND Ground 12 GND Ground 6 Note: Name Exposed pad must be properly grounded using a low impedance path. Table 2. SKY13374-397LF Absolute Maximum Ratings (Note 1) Minimum Maximum Units Supply voltage Parameter VBATT Symbol 2.5 4.8 V Control voltage VCTL 1.65 3.00 V Input power PIN +39 dBm Storage temperature TSTG –40 +125 C Operating temperature TOP –40 +85 C Note 1: Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device. CAUTION: Although this device is designed to be as robust as possible, Electrostatic Discharge (ESD) can damage this device. This device must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times. Functional Description Electrical and Mechanical Specifications Switching is controlled by two control voltage inputs (V1 and V2). Depending on the logic voltage level applied to these pins, the RF1 pin is connected to one of two switched RF outputs (RF2 or RF3) using a low insertion loss path, while the path between the RF1 pin and the other RF path is in a high isolation state. The absolute maximum ratings of the SKY13374-397LF are provided in Table 2. Electrical specifications are provided in Table 3. An internal negative voltage generator and decoder eliminate the need for external DC blocking capacitors on the RF ports. No external components are required for proper operation. DC decoupling capacitors may be added on the VBATT and control lines if necessary. The state of the SKY13374-397LF is determined by the logic provided in Table 4. Typical performance characteristics of the SKY13374-397LF are illustrated in Figures 3 through 5. Shutdown mode is enabled by connecting both control pins (V1 and V2) to logic low. This mode reduces the overall current consumption of the device to 5 μA typical. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 2 November 11, 2013 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201447K DATA SHEET • SKY13374-397LF SPDT SWITCH Table 3. SKY13374-397LF Electrical Specifications (Note 1) (VBATT = 2.5 to 4.8 V, V1/V2 = 0/1.65 to 3.0 V, TOP = +25 C, PIN = 0 dBm, Characteristic Impedance [ZO] = 50 Ω, Unless Otherwise Noted) Parameter Symbol Test Condition Min Typical Max Units 0.35 0.45 0.50 0.8 0.40 0.55 0.60 1.00 dB dB dB dB RF Specifications Insertion loss IL RF1 to RF2/RF3: 300 kHz to 1.0 GHz 1.0 to 2.2 GHz 2.2 to 3.0 GHz 4.9 to 6.0 GHz Isolation Iso RF1 to RF2/RF3: 300 kHz to 2.2 GHz 2.2 to 3.0 GHz 4.9 to 6.0 GHz 30 25 18 34 28 22 dB dB dB 16 dB 17 dB Shutdown isolation Iso_SHUTDOWN Return loss |S11| RF1 to RF2/RF3, 300 kHz to 6.0 GHz 0.1 dB Input Compression Point IP0.1dB RF1 to RF2/RF3, 0.5 to 6.0 GHz +39 dBm 3rd Order Input Intercept Point IIP3 0.8 to 3.0 GHz, Δf = 1 MHz, PIN = +26 dBm/tone +68 dBm 50% VCTL to 90% RF 1200 ns 50% VCTL to 10% RF 1200 ns 10% RF to 90% RF rise 200 ns 90% RF to 10% RF fall 150 ns Shutdown to any RF switch state 20 μs Switching Speed Specifications Switching speed @ 2.45 GHz Startup time DC Specifications Control voltage: high low V1, V2 Supply voltage VBATT Supply current IBATT VBATT = 3 V 40 μA Control current ICTL V1/V2 = 1.8 V 2 μA Shutdown mode supply current IOFF V1/V2 = 0 V, VBATT = 1.8 V 5 μA 1.65 0 3.00 0.30 V V 2.5 4.8 V Note 1: Performance is guaranteed only under the conditions listed in this Table. Table 4. SKY13374-397LF Truth Table Note: V1 V2 State 0 0 Shutdown mode 1 0 RF1 to RF2 0 1 RF1 to RF3 1 = 1.65 to 3.0 V 0 = –0.1 to 0 V Any state other than described in this Table places the switch into an undefined state. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 201447K • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 11, 2013 3 DATA SHEET • SKY13374-397LF SPDT SWITCH Typical Performance Characteristics (VCTL = 0 V and +3.0 V, TOP = +25 C, PIN = 0 dBm, Characteristic Impedance [ZO] = 50 Ω, Unless Otherwise Noted) 0 0 RF1 to RF2 RF1 to RF3 –0.1 –10 –20 –0.3 Isolation (dB) Insertion Loss (dB) –0.2 –0.4 –0.5 –0.6 –30 –40 –50 –0.7 –0.8 –60 –0.9 –1.0 –70 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 Figure 4. Typical Isolation vs Frequency (RF1 to RF2 Insertion Loss State) Figure 3. Typical Insertion Loss vs Frequency 0 –10 Isolation (dB) –20 –30 –40 –50 –60 –70 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 Frequency (GHz) Figure 5. Typical Isolation vs Frequency (RF1 to RF3 Insertion Loss State) Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 4 5.0 Frequency (GHz) Frequency (GHz) November 11, 2013 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201447K 5.5 6.0 DATA SHEET • SKY13374-397LF SPDT SWITCH Evaluation Board Description Package and Handling Information The SKY13374-397LF Evaluation Board is used to test the performance of the SKY13374-397LF SPDT Switch. Instructions on the shipping container label regarding exposure to moisture after the container seal is broken must be followed. Otherwise, problems related to moisture absorption may occur when the part is subjected to high temperature during solder assembly. An Evaluation Board schematic diagram is provided in Figure 6. An assembly drawing for the Evaluation Board is shown in Figure 7. THE SKY13374-397LF is rated to Moisture Sensitivity Level 1 (MSL1) at 260 C. It can be used for lead or lead-free soldering. For additional information, refer to the Skyworks Application Note, Solder Reflow Information, document number 200164. Package Dimensions The PCB layout footprint for the SKY13374-397LF is provided in Figure 8. Typical case markings are shown in Figure 9. Package dimensions for the 12-pin QFN are shown in Figure 10, and tape and reel dimensions are provided in Figure 11. Care must be taken when attaching this product, whether it is done manually or in a production solder reflow environment. Production quantities of this product are shipped in a standard tape and reel format. RF Port 2 RF Port 1 1 2 RF2 VBATT RF1 V2 GND V1 4 RF3 GND 3 N/C 5 9 8 7 DC Power Supply DC Control 2 DC Control 1 GND × 10 GND 11 GND 12 6 RF Port 3 S2568 Figure 6. SKY13374-397LF Evaluation Board Schematic Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 201447K • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 11, 2013 5 DATA SHEET • SKY13374-397LF SPDT SWITCH S3357 Figure 7. SKY13374-397LF Evaluation Board Assembly Diagram 12X 0.710 Part Outline Pin 12 12X 0.440 R0.20 Pin 1 Indicator 12X 0.200 Pin 1 2X 0.380 0.500 Pitch Exposed Solder Area 2X 0.380 All measurements in millimeters S3580 Figure 8. SKY13374-397LF PCB Layout Footprint (Top View) Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 6 November 11, 2013 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201447K DATA SHEET • SKY13374-397LF SPDT SWITCH Pin 1 Indicator Skyworks Part Number Y0328 Figure 9. Typical Case Markings (Top View) Seating Plane –C– 2.00 0.92 +0.10/–0.15 –A– (0.460) 0.02 +0.03/–0.02 R0.20 Pin 1 Indicator –B– Pin 1 Indicator Detail A Pin 1 2.00 0.92 +0.10/–0.15 (0.460) 0.05 C 2X 0.55 + 0.05/–0.04 2X 0.05 C 12X 3 0.05 C 0.05 C Top View Exposed Pad 0.50 12X 0.15 Min. Side View Bottom View 0.29 ± 0.075 0.2 ± 0.05 5 0.10 M C A B All measurements are in millimeters. Dimensioning and tolerancing according to ASME Y14.5M-1994. Coplanarity applies to the terminals and all other bottom surface metalization. Dimension applies to metalized terminal. If the terminal has a radius on its end, the width dimension should not be measured in that radius area. Detail B S1985 Figure 10. SKY13374-397LF 12-Pin QFN Package Dimensions Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 201447K • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 11, 2013 7 DATA SHEET • SKY13374-397LF SPDT SWITCH ∅1.50+ 0.10/–0.00 0.30 ± 0.05 (T) Pin #1 4.00 ± 0.10 2.00 ± 0.05 4.00 (see Note 4) 1.75 ± 0.10 2.30 (Bo) A B 1.00 (Ko) 2.30 (Ao) 8.00 +0.30/–0.10 A 3.50 ± 0.05 B ∅1.00 Min. R0.30 Typ. B Notes: 1. Carrier tape: black conductive polystyrene. 2. Cover tape material: transparent conductive HSA. 3. Cover tape size: 5.40 mm width. 4. Ten sprocket hole pitch cumulative tolerance = ±0.20 mm. 5. ESD surface resistivity is ≤1 x 108 Ohms/square per EIA, JEDEC tape and reel specification. 6. Ao and Bo measurement point to be 0.30 mm from bottom pocket. 7. All measurements are in millimeters. A Figure 11. SKY13374-397LF Tape and Reel Dimensions Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 8 November 11, 2013 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201447K S1601 DATA SHEET • SKY13374-397LF SPDT SWITCH Ordering Information Model Name SKY13374-397LF SPDT Switch Manufacturing Part Number SKY13374-397LF Evaluation Board Part Number SKY13374-397LF-EVB Copyright © 2010-2013 Skyworks Solutions, Inc. All Rights Reserved. Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes. No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions of Sale. THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury, death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any damages resulting from such improper use or sale. Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters. Skyworks, the Skyworks symbol, and “Breakthrough Simplicity” are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are incorporated by reference. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 201447K • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 11, 2013 9