XSU Series - First Sensor

XSU Series
Miniature basic pressure sensors
FEATURES
· 1 to 100 psi absolute or gage
· Wide operating temperature range
from -40 ... 85 °C
· Miniature SMT housings
· Low cost
· Quality Management System according
to ISO 13485:2003 and ISO 9001:2008
MEDIA COMPATIBILITY
To be used with non-corrosive, non-ionic working
fluids such as clean dry air, dry gases and the like.
EQUIVALENT CIRCUIT
SPECIFICATIONS
Maximum ratings
Supply voltage, VS
Supply current, IS
15 VDC
3 mA
Temperature ranges
Operating
Storage
-40 ... +85°C
-40 ... +125°C
Humidity limits (non-condensing)
15 ... 85 %RH
Overpressure1
-Vout
+Vs
-Vs
2 x rated pressure
+Vout
E / 11662 / E
1/4
www.first-sensor.com
www.sensortechnics.com
XSU Series
Miniature basic pressure sensors
PRESSURE SENSOR CHARACTERISTICS
(VS = 5 V or IS = 1 mA, TA = 25 ±3 °C, pressure applied to high pressure port)
Part number
Operating pressure
XSUP001...
Full-scale span2
Min.
Typ.
Max.
0...1 psi
18 mV
30 mV
42 mV
XSUP006...
0...5.8 psi
45 mV
75 mV
105 mV
XSUP015...
0...15 psi
64 mV
100 mV
136 mV
XSUP030...
0...30 psi
74 mV
110 mV
146 mV
XSUP100...
0...100 psi
60 mV
120 mV
180 mV
Max.
Unit
+30
mV
PERFORMANCE CHARACTERISTICS5
(VS = 5 V or IS = 1 mA, TA = 25 ±3 °C, pressure applied to high pressure port)
Characteristics
Min.
Zero pressure offset
Temperature effects
-30
Offset
(0...50 °C)
3
Span
1 psi devices
±0.22
all others
±0.08
for VS = 5 V
-0.16 ... -0.26
for IS = 1 mA
±0.05
Bridge impedance
4
Non-linearity
Bridge resistance
Typ.
%FSS/°C
0.2
1 psi devices
±0.7
all others
±0.3
3.8
5
%/°C
%FSS
6.2
kΩ
Specification notes:
1.
2.
3.
4.
If the overpressure is exceeded, even momentarily, the package may leak or burst, or the pressure sensing die may fracture.
Span is the algebraic difference between the output voltage at full-scale pressure and the output at zero pressure.
For constant current excitation at 1 mA the temperature coefficient of span is typ. ±0.05 %FSS/°C
Non-linearity is the maximum deviation of measure output at constant temperature (25°C) from "Best Straight Line" determined by
three points, offset, full scale pressure and half full scale pressure.
5. These values are only tested on a sample basis, therefore only typ. values can be given by First Sensor.
E / 11662 / E
2/4
www.first-sensor.com
www.sensortechnics.com
XSU Series
Miniature basic pressure sensors
PHYSICAL DIMENSIONS AND ELECTRICAL CONNECTIONS
XSU...GY
2.54
0.8
3
2
1
Pin
1
2
3
4
5
6
Projections
4
5
6
Connection
-Vout
+Vs
+Vout
N/C
-Vs
-Vout
first angle projection
6.0
0.4 x 45 °
dimensions in mm
3.5
10.0
1.55
Ø 3.0
2.0
Projections
10.3
1.4
2.54
4
5
6
Ø 1.0
Vent hole
3
2
7.0
E / 11662 / E
1
6.0
3.0
3.0
3.85
9.4
7.0
0.7
6.0
0.33
1.7
0.25
Pad layout
Index
Landing pads
Ø 1.0
(holes for projections)
3/4
www.first-sensor.com
www.sensortechnics.com
XSU Series
Miniature basic pressure sensors
PHYSICAL DIMENSIONS AND ELECTRICAL CONNECTIONS (cont.)
XSU...AY
2.54
0.8
4
5
6
Pin
1
2
3
4
5
6
Index
3
2
1
Connection
-Vout
-Vs
+Vout
N/C
+Vs
-Vout
0.3 x 45 °
5.88
Ø 3.0
5.25
dimensions in mm
Pad layout
3.5
0.4 x 45 °
9.25
first angle projection
10.4-10.5
1.7
1.4
0.45
0.25
0.33
2.54
3
2
1
Ø 1.0
3.85
9.4
7.0
0.7
4
5
6
Landing pads
7.0
ORDERING INFORMATION
Pressure range
0...1
0...5.8
0...15
0...30
0...100
p si
p si
p si
p si
p si
Absolute
Gage
XSUP015AY
XSUP030AY
XSUP100AY
XSUP001GY
XSUP006GY
XSUP015GY
XSUP030GY
XSUP100GY
Note: Other options are available on request. Please contact First Sensor.
First Sensor reserves the right to make changes to any products herein.
First Sensor does not assume any liability arising out of the application
or use of any product or circuit described herein, neither does it convey
any license under its patent rights nor the rights of others.
E / 11662 / E
4/4
www.first-sensor.com
www.sensortechnics.com