Ten-X® - First Sensor

Ten-X®
10 mm switching solenoid valve
FEATURES
· 3-way, 2 position (NO, NC & Distributor)
· Optional ‘Hit and Hold’ drive electronics
using pulse width modulation (PWM)
for low power consumption
· Minimum flow of 8 lpm @ 6 psi and
22 lpm @ 30 psi
· Over 20 million cycles
· 10 mm single piece body design
· Barbed pressure ports allow for direct
tubing or manifold assemblies
· RoHS compliant
PHYSICAL PROPERTIES
MEDIA COMPATIBILITY
Non-reactive gases
Operating environment (continuous duty)
Storage temperature
WETTED MATERIALS
PBT (polybutylene terephthalate) glass filled;
430FR series stainless steel; 302 series stainless
steel; silicone, EPDM or Viton (FKM) elastomer
Voltage
Electrical connections
Porting
1.0 W
0.5 W
-40...70 °C
10 mm (centerline)
Barbs for 1.98 mm (0.078 in) I.D. tubing
or manifold mount with gasket
Weight
without electronics
with electronics
ELECTRICAL
Power
914...2... (Type 2), 914...6... (Type 6)
all other
Spacing
0...50 °C
Internal volume
10.7 g
12 g
0.131 cm3 (0.0080 in3)
5, 12, 24 VDC
PC pins
Ten-X is a registered trademark of Parker Hannifin Corporation.
E / 11260 / D
1/4
www.first-sensor.com
www.sensortechnics.com
Ten-X®
10 mm switching solenoid valve
PERFORMANCE CHARACTERISTICS
Part no.
Pressure Minimum flow
914-1...
(silicone elastomer)
0...6 psi
914-2...
(Viton & EPDM elastomer)
0...6 psi,
0...20 psi,
0...30 psi
Orifice siz es/
Equivalent CV1
8 lpm @ 6 psi, 0.060" (1.52 mm)/
22 lpm @ 30 psi
0.042 CV
Leak rate2 Response
≤0.016 sccm
<5 ms
cycling
≤0.2 sccm
<20 ms
cycling
FLOW CURVES (typical air flow at 24 °C)3
Flow (slpm)
6 psi devices
Pressure (psi)
Flow (slpm)
20 psi and 30 psi
devices
Pressure (psi)
Notes:
1
The CV value is the volume flow in US gallons/min under specific flow conditions and describes the relative flow capacity of a
valve. The equivalent european measure is the kV value expressed in m3/h (kV = 0.86 CV).
2
sccm denotes Standard Cubic Centimeters per Minute. It is a unit for the flow rate at standard conditions of temperature and
pressure. 1000 sccm = 1 slpm.
3
slpm denotes Standard Liters per Minute. It is a unit for the flow rate at standard conditions of temperature and pressure.
1 slpm = 1000 sccm.
E / 11260 / D
2/4
www.first-sensor.com
www.sensortechnics.com
Ten-X®
10 mm switching solenoid valve
OUTLINE DRAWING AND MANIFOLD MOUNT DIAGRAM
6 psi devices
1.139 (28.93)
0.020 (0.5)
sq. pins
0.077 (1.96)
0.575
0.375 (14.61)
Long
pin
(9.53)
Short pin
0.475
(12.07)
0.170
(4.32)
Normally open port
Common port
Normally closed port
0.148 (3.75)
Ø 0.120 (3.05)
0.030 (0.76)
for use with wire hold down
for PCB mounting
Barb fittings for
0.078 (1.98) I.D.
polyurethane tubing
Ø 0.093 (2.36)
0.976 (24.79)
0.212 (5.38)
2-56
UNC-2B
0.766 (19.46)
dimensions in inches (mm)
0.871
(22.12)
0.197
(5.0)
0.394
(10.01)
0.394
(10.01)
0.390
(9.91) 0.195
(4.95)
0.174 (4.42)
0.236 (6.00)
Feature for
2-56 screw for
valve mounting
0.870 (22.10)
0.766
(19.46)
0.976
(24.79)
0.207 (5.26)
1.25 (31.78)
Ø 0.090
Ø 0.132 ±0.001 x 0.180
Ø 0.154 ±0.003 x 0.055 ±0.002
c'drill 40° to Ø 0.132
(Ø 2.29
Ø 3.35 ±0.025 x 4.57
Ø 3.91 ±0.076 x 1.4 ±0.05
c'drill 40° to Ø 3.35)
20 psi and 30 psi devices with electronics
1.303 (33.10)
0.025 (0.64)
sq. pins
1.174 (29.81)
0.212
(5.38)
0.100
(2.54)
0.361
(9.17)
0.619
(15.72)
Normally open port
Common port
Normally closed port
0.170
(4.32)
Ø 0.120 (3.05)
0.035 (0.89)
Ø 0.093 (2.36)
0.976 (24.79)
0.267 (6.78)
0.766 (19.46)
2-56
UNC-2B
0.871
(22.12)
Feature for
2-56 screw for
valve mounting
0.870 (22.10)
0.262 (6.65)
0.197
(5.0)
0.394
(10.01)
0.394
(10.01)
0.390
(9.91) 0.195
(4.95)
E / 11260 / D
dimensions in inches (mm)
Barb fittings for
0.078 I.D.
polyurethane tubing
0.766
(19.46)
0.976
(24.79)
Ø 0.090
Ø 0.132 ±0.001 x 0.180
Ø 0.154 ±0.003 x 0.055 ±0.002
c'drill 40° to Ø 0.132
(Ø 2.29
Ø 3.35 ±0.025 x 4.57
Ø 3.91 ±0.076 x 1.4 ±0.05
c'drill 40° to Ø 3.35)
3/4
www.first-sensor.com
www.sensortechnics.com
Ten-X®
10 mm switching solenoid valve
ORDERING INFORMATION
6 psi devices
Series
Options
914
Elastomer
1 Silicone
Type
1* 2 way, NO, 6 psi
2
Viton (FKM) 2** 2/3 way, NC, 6 psi
3
EPD M
Model
1 Standard
(without
electronics)
6** Distributor, 6 psi
Voltage
05
5 VDC
12 12 V D C
Electical
1 Short pins
2
Accessories*
000
none
Long pins
24 24 V D C
7* 3 way, NO, 6 psi
* Silicone & EPDM only
** Viton (FKM) only
Example:
914
1
1
* please order
separately
1
05
1
000
20 psi and 30 psi devices with electronics
Series
Options
914
Elastomer
Type
Model
2
Integrated
electronics
Voltage
2
Viton (FKM)
3
2/3 way, NC, 30 psi
05
5 VDC
3
EPD M
4
2/3 way, NO, 30 psi
12 12 V D C
5
Distributor, 20 psi
24 24 V D C
Electical
3
Pins
(2.54 mm)
Accessories*
000
none
* please order
separately
Example:
914
2
3
2
05
3
000
Note: Not all combinations might be available. Please contact First Sensor for further information.
Accessories
(please order separately using the following order numbers)
Order No.
Description
191-000112-010 (extra charge)
Mounting screws for 6 psi devices (2 screws per valve)
191-000112-012 (extra charge)
Mounting screw for 20 psi and 30 psi devices (2 screws per valve)
195-000211-001 (extra charge)
Manifold gasket (FKM) (1 gasket per valve)
195-000242-001 (extra charge)
Manifold gasket (EPDM) (1 gasket per valve)
590-000073-001 (extra charge)
18 " leads w/ connector (only for devices with integrated electronics)
First Sensor reserves the right to make changes to any products herein. First Sensor does not assume any liability arising out of the application
or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
E / 11260 / D
4/4
www.first-sensor.com
www.sensortechnics.com