V2 Valve - First Sensor

V2 Valve
Value squared switching solenoid valve
FEATURES
· 2-way or 3-way, 2 position valve
(NO, NC & Distributor)
· Meets performance characteristics for
a minimum of 25 million cycles
· Cost-effective, unique PBT body
· Manifold mount design or molded
barbed fittings to fit a range of needs
PHYSICAL PROPERTIES
MEDIA COMPATIBILITY
Non-corrosive gases
Operating environment
Storage temperature
0 to 70 °C
-40 to 70 °C
WETTED MATERIALS
Length
43.9 mm (1.73 in)
Width
15.9 mm (0.625 in)
Stem base:
360 HO2 brass
Height
17 mm (0.67 in)
All others:
FKM; 430 FR series stainless steel (passivated);
302 series stainless steel; Loctite® 290
Porting
Barb fittings for 1/8 in I.D. tubing
or manifold mount
Weight
34 g (1.2 oz)
Body:
PBT (Polybutylene Terephthalate)
ELECTRICAL
Power
Voltage
0.016 cm3 (nominal)
Internal volume
0.5, 1.0 or 2.0 W
5, 12, 24 VDC ± 10%
Filtration (recommended)
Lubrication
40 µm
None required
Loctite® is a registered trademark of Henkel Consumer Adhesives, Inc.
E / 11252 / A
1/4
www.first-sensor.com
www.sensortechnics.com
V2 Valve
Value squared switching solenoid valve
PERFORMANCE CHARACTERISTICS
Part no.
Pressure
V210...
0...100 psig
V213...
0...50 psig
V214...
0...30 psig
V217...
0...15 psig
V220...
0...6 psig
Vacuum
Orifice siz es/
Equivalent CV1
Leak rate2
<30 msec cycling
(2 Watt)
0.030" (0.762 mm)/
0.017 CV
0...27 "Hg
(0...13 psi)
R esp o n se
≤0.2 sccm
<30 msec cycling
(2 Watt)
0.050" (1.270 mm)/
0.035 CV
FLOW CURVES (typical air flow)3
Notes:
1
The CV value is the volume flow in US gallons/min under specific flow conditions and describes the relative flow capacity of a
valve. If several valves with the same nominal diameter are compared, the valve with the highest CV value has the best flow
dynamics design. The equivalent european measure is the kV value expressed in m3/h (kV = 0.86 CV).
2
sccm denotes Standard Cubic Centimeters per Minute. It is a unit for the flow rate at standard conditions of temperature and
pressure. 1000 sccm = 1 slpm.
3
slpm denotes Standard Liters per Minute. It is a unit for the flow rate at standard conditions of temperature and pressure.
1 slpm = 1000 sccm.
E / 11252 / A
2/4
www.first-sensor.com
www.sensortechnics.com
V2 Valve
Value squared switching solenoid valve
VALVE TYPE
Type 1
Type 3
Type 4
E / 11252 / A
3/4
www.first-sensor.com
www.sensortechnics.com
V2 Valve
Value squared switching solenoid valve
COIL STYLES
V2...P...
(PC mount, 4 PC pins)
V2...F...
(Wire leads,
no terminals)
V2...8...
(1/8" I.D. tubing)
V2...0...
(Manifold mount)
BODY STYLES
STEM BARB STYLES
V2...0
(Type 1 top seat, plugged)
V2...8
(0.125" top seat, 1/8" I.D. tubing)
ORDERING INFORMATION
Model no.
Series
Options
V2
Max.
pressure
Orifice
size
10: 0...100 psi 0.030"
Material
C oi l
wattage
Type
2W
1: 2-way NC
1W
2W
3: 3-way NC
or
distributor
1W
4: 3-way NO
B ody
PV: PBT
Plunger
& se a l
FK M
5:
(0.762 mm)
13:
0...50 psi 0.030"
(0.762 mm)
14:
0...30 psi 0.050"
0...15 psi 0.050"
B ody
styles
Topseat
barbs
5 V DC
P: PC mount,
4 PC pins
0: manifold
0: none
(manifold
mount)
F: Wire leads,
18"
8: 1/8"
barbs
8: 1/8"
barbs
12: 12 V D C
24: 24 V D C
(1.270 mm)
17:
Coil type
Voltage
(1.270 mm)
20:
0...6 psi 0.050"
0.5 W
(1.270 mm)
Example:
V2
14
3
PV
12
P
8
8
Note: Not all combinations might be available. Please contact First Sensor for further information.
First Sensor reserves the right to make changes to any products herein. First Sensor does not assume any liability arising out of the application
or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
E / 11252 / A
4/4
www.first-sensor.com
www.sensortechnics.com