File E135803 Vol. 1 Sec. 35 and Report *Page 1 Issued: Revised: 11-08-96 07-24-02 DESCRIPTION: PRODUCT COVERED: USR - Switching Power Supply, Model GLC75, followed by suffix A, B, C, D, E, F, J, P, may or may not be followed by -CV, -L, -LC, or -V, Model GLC75-X where X may be any number from 5 thru 28, may or may not be followed by suffix –L, Model GLC75-24-102, Model SP1583A, and Model SP1663. ELECTRICAL RATINGS: Input: 100-240 V ac, 50/60 Hz, 3.1 A (GLC75 Multi-Output Models) Outputs: Maximum output power is 75 W with convection cooling; 65 W with chassis/cover option with convection cooling; 110 W with airflow specified below. Model SP1663 maximum output power is 50 W with convection cooling. Output #1 Model 0 cfm GLC75A GLC75B GLC75C GLC75D GLC75E GLC75F GLC75J GLC75P SP1663 +5.1 8 A +5.1 8 A +5.1 8 A +5.1 8 A +5.1 8 A +5.1 8 A +5.1 8 A +5.1 8 A +5.1 6 A Input: 26 cfm V 10 A V 10 A V 10 A V 10 A V 10 A V 10 A V 10 A V 10 A V -- Output #2 0 cfm +12 2.5 +12 2.5 +12 2.5 +24 2.5 +24 2.5 +15 2.5 +12 2.5 +24 4.0 +12 1.5 V A V A V A V A V A V A V A V A V A 26 cfm 3.0 A 3.0 A 3.0 A 2.5 A 2.5 A 3.0 A 3.0 A 4.0 A -- Output #3 0 cfm -12 1.0 -5 1.0 -15 1.0 -12 1.0 -15 1.0 -5 1.0 -12 1.0 -12 1.0 -12 1.0 V A V A V A V A V A V A V A V A V A 26 cfm Output #4 0 cfm 1.0 A 12 V 2.5 A 12 V 2.5 A 15 V 2.5 V 12 V 2.5 A 15 V 2.5 V 15 V 2.5 V 5 V 2.0 V 12 V 2.5 A -- -- 1.0 A 1.0 A 1.0 A 1.0 A 1.0 A 1.0 A 1.0 A 26 cfm 3.0 A 3.0 A 3.0 A 3.0 A 3.0 A 3.0 A 3.0 A 3.0 A -- 100-240 V ac, 50/60 Hz, 3.0 A (GLC75 Single-Output Models) Output: 5 thru 28 V, 20 thru 4 A Power Ratings for 5 thru 11 V 70 W maximum, convection cooled. 100 W maximum, with a minimum of 26 CFM airflow. Power Ratings for 12 thru 28 V 75 W maximum, convection cooled. 110 W maximum, with a minimum of 26 CFM airflow. File E135803 Vol. 1 Sec. 35 and Report Page 3 Issued: Revised: 11-08-96 07-24-02 CONSTRUCTION DETAILS: See Section General for additional details. Operating/Instruction/Safety Manual - Provided with each unit. ILL. 2. See Printed Wiring Board - See Section General for details. General appearance of trace layout same as in ILLS. 1 and 6. rated 130°C. Board Model Differences - All models are the same, except for output ratings and differences in secondary low-voltage circuitry. Suffix -CV indicates chassis, cover, and voltage adjust options are installed. Suffix -L indicates chassis option is installed. Suffix -LC indicates chassis and cover options are installed. Suffix -V indicates voltage adjust option is installed. Model SP1663 is the same as above, except for printed wiring board size and alternate secondary layout. Provided with an L-bracket chassis. * Model GLC75-24-102 is identical to Model GLC75-22. Statement of Compliance Condor Re port: 239 Master Contract: 150684 (LR 46516C) Edition: 1 Date Issued: July 25, 2002 Issued by: Condor D.C. Power Supplies Inc. 2311 Statham Parkway Oxnard, CA 93033 USA The products listed below are eligible to bear the CSA Mark shown Issued by: David Hemphill Signature: PRODUCTS CLASS 5311 03 - POWER SUPPLIES - Component Type Component power supplies for use with Information Technology Equipment, where the suitability of the combination is to be determined by CSA International. MODEL NUMBERS: Model SP1583A, GLC75-24-102, and GLC75–X where X represents the output voltage, which may be any number from 5 thru 28. Models may be followed by suffix –L for chassis bracket. Models may or may not include a chassis bracket and have any output as described below. Input: Output: 100-240 V ac, 3.0 A, 50/60 Hz 5 thru 28 V, 20 thru 4 A (L3M1) 70 W maximum for output voltages from 5 thru 11 V with convection cooling 75 W maximum for output voltages from 12 thru 28 V with convection cooling 100 W maximum for output voltages from 5 thru 11 V with 26 CFM forced air cooling 110 W maximum for output voltages from 12 thru 28 V with 26 CFM forced air cooling Notes: 1. Maximum Operating Ambient Temperature 50 °C. 2. Maximum Operating Relative Humidity 96 %, no condensation. 3. Storage: -40 to +85 °C. Units should be allowed to warm-up under non-condensing conditions before application of power. APPLICABLE REQUIREMENTS CAN/CSA-C22.2 No. 60950-00 - Safety of Information Technology Equipment, Including Electrical Business Equipment This is to certify that the equipment indicated above has been tested, evaluated and found to comply to all relevant CSA International requirements. This equipment is eligible to bear the CSA Mark as authorized by the CSA Category Certification Program under Master Contract No. 150684 (LR 46516C). Page 1 Condor Re port: 239 Edition: 1 Master Contract: 150684 (LR 46516C) Date: July 25, 2002 CONDITIONS OF ACCEPTABILITY 1. This component has been judged on the basis of the required spacings in the Standard for Safety of Information Technology Equipment, CAN/CSA-C22.2 No. 60950-00, which covers the end-use product for which the component is designed. 2. The enclosure provided with this equipment does not meet the applicable requirements for Fire or Electrical enclosures. Suitable enclosure to be provided in the end-use equipment. 3. The input/output connectors are not acceptable for field connections, they are only intended for connection to mating connectors of internal wiring inside the end-use equipment. 4. The main isolation transformer (T3) is provided with Class F insulation. 5. The power supply was evaluated for Reinforced insulation between primary and secondary, and Basic insulation between primary and ground, based on min 250 V ac. 6. The power supply was evaluated as Class I equipment, continuous operation, pollution degree 2. 7. Under normal and single fault conditions, the outputs do not exceed SELV limits. Page 2 Certificate of Compliance Certificate: 1298171 Master Contract: 150684 (LR 46516C) Edition: 2 Date Issued: August 19, 2002 Issued to: Condor D.C. Power Supplies Inc. 2311 Statham Parkway Oxnard, CA 93033 USA The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' Issued by: Vincent Un, B.Sc. Authorized by: Terry Nagy Operations Manager PRODUCTS CLASS 5311 03 - POWER SUPPLIES - Component Type CLASS 5311 83 - POWER SUPPLIES - Component Type - Certified to US Standards Component power supplies for use with Information Technology Equipment, where the suitability of the combination is to be determined by CSA International. Input: 100-240 V ac, 3.1 A, 50/60 Hz Output: Maximum Continuous Power, total of all outputs at ambient of 50°C. Standard & -L option 26 CFM 0 CFM 110 Watts 75 Watts With Chassis/Cover (Note 5) 26 CFM 0 CFM 110 Watts 65 Watts The 'C' and 'US' indicators adjacent to the CSA Mark signify that the product has been evaluated to the applicable CSA and ANSI/UL Standards, for use in Canada and the U.S., respectively. This 'US' indicator includes products eligible to bear the 'NRTL' indicator. NRTL, i.e. National Recognized Testing Laboratory, is a designation granted by the U.S. Occupational Safety and Health Administration (OSHA) to laboratories which have been recognised to perform certification to U.S. Standards. FF02 DQD 507WD 2002/03/01 Certificate: Edition: 1298171 2 Master Contract: 150684 (LR 46516C) Date: August 19, 2002 Output #1 MODEL Output #2 Note 2 Note 3 Output #3 Note 2 Note 3 Output #4 Note 2 Note 3 Note 2 Note 3 GLC75A +5.1 V 8A 10 A +12 V 2.5 A 3.0 A -12 V 1.0 A 1.0 A +12 V 2.5 A 3.0 A GLC75B +5.1 V 8A 10 A +12 V 2.5 A 3.0 A -5 V 1.0 A 1.0 A +12 V 2.5 A 3.0 A GLC75C +5.1 V 8A 10 A +12 V 2.5 A 3.0 A -15 V 1.0 A 1.0 A +15 V 2.5 A 3.0 A GLC75D +5.1 V 8A 10 A +24 V 2.5 A 2.5 A -12 V 1.0 A 1.0 A +12 V 2.5 A 3.0 A GLC75E +5.1 V 8A 10 A +24 V 2.5 A 2.5 A -15 V 1.0 A 1.0 A +15 V 2.5 A 3.0 A GLC75F +5.1 V 8A 10 A +15 V 2.5 A 3.0 A -5 V 1.0 A 1.0 A -15 V 2.5 A 3.0 A GLC75H +5.1 V 8A 10 A +15 V 2.5 A 3.0 A -15 V 1.0 A 1.0 A +15 V 2.5 A 3.0 A GLC75J +5.1 V 8A 10 A +12 V 2.5 A 3.0 A -12 V 1.0 A 1.0 A 5V 2.0 A 3.0 A GLC75P +5.1 V 8A 10 A +24 V 4.0 A 4.0 A -12 V 1.0 A 1.0 A +12 V 2.5 A 3.0 A Model SP1663, input rated 100-240 V ac, 2.9 A, 50/60 Hz; dc outputs rated +5.1 V/6 A, +12 V/1.5 A, -12 V/1.0 A (L3M1); 50 W maximum total output power. Notes: 1. Model may be followed by –L for chassis bracket, –C or –LC for chassis/cover, or –V for Voltage Adj. Pot (+5.1 V). 2. Maximum ratings for 0 CFM airflow without chassis/cover. 3. Maximum ratings for 26 CFM airflow. 4. Maximum Operating Relative Humidity 96%, no condensation. 5. Contact Condor Technical Support for airflow requirements when using chassis/cover option. 6. Storage: -40 to +85°C. Units should be allowed to warm-up under non-condensing conditions before application of power. APPLICABLE REQUIREMENTS CAN/CSA C22.2 No. 950-95 - ANSI/UL 1950-1997 - DQD 507WD 2002/03/01 Safety of Information Technology Equipment, Including Electrical Business Equipment Safety of Information Technology Equipment, Including Electrical Business Equipment Certificate: Edition: 1298171 2 Master Contract: 150684 (LR 46516C) Date: August 19, 2002 CONDITIONS OF ACCEPTABILITY 1. The enclosure provided with this equipment does not meet the applicable requirements for Fire or Electrical enclosures. Suitable enclosure to be provided in the end-use equipment. 2. The input/output connectors are not acceptable for field connections , they are only intended for connection to mating connectors of internal wiring inside the end-use equipment. 3. The main isolation transformer (T3) is provided with Class F insulation. 4. The temperature tests were performed in a raised ambient of 50°C. 5. The power supply was evaluated for Reinforced insulation between primary and secondary, and Basic insulation between primary and ground, based on min 250 V ac. 6. Under normal and single fault conditions, the outputs do not exceed SELV limits. DQD 507WD 2002/03/01 Supplement to Certificate of Compliance Certificate: 1298171 Master Contract: 150684 (LR 46516C) The products listed, including the latest revision described below, are eligible to be marked in accordance with the referenced Certificate. Product Certification History Edition Date 1 March 13, 2002 2 August 19, 2002 DQD 507WD 2002/03/01 Description Original Certification. (Re-issued Report LR 46516-244C as Report 1298171 and updated to add Models GLC75F, GLC75H and GLC75J). Updated to add Model SP1663 and minor corrections to report. (Project 1350492)