GSM11 Instructions - SL Power Electronics

GSM11 SERIES
INSTALLATION INSTRUCTIONS
SL Power Electronics, Corp.
6050 King Dr. Unit A
Ventura, CA 93003 + 805-486-4565
Internet: www.condorpower.com
MODEL NUMBERS: GSM11-XYZ-XXXG, where X represents the output voltage which may be any number from 3.3 thru 28; Y
indicates the type of input connector used which may be the letters A, B, P or T; Z indicates the type of output connector used which may
be the letters A thru Z; Models may or may not be followed by –XXX, where XXX may be any number from 001 thru 999. The –XXX
suffix are used for value added configurations that have no impact on safety; and G indicates compliance to RoHS.
RATINGS:
Input:
Output:
100-240 V ac, 0.3 A, 50/60 Hz
2.2 A or 11 W maximum or see table for standard output voltage models.
MODEL
GSM11-3
GSM11-5
GSM11-12
GSM11-15
GSM11-24
GSM11-28
OUTPUT
3.3 V dc 2.2 A
5.1 V dc 2.2 A
12 V dc 0.92 A
15 V dc 0.74 A
24 V dc 0.46 A
28 V dc 0.0.4 A
Notes:
1.
Maximum Operating Ambient Temperature 50 °C, convection cooled.
2.
Maximum Operating Relative Humidity 96 %, no condensation.
3.
Storage: -40 to +85 °C. Units should be allowed to warm-up under non-condensing conditions before application of power.
4.
On GSM11-3(Y)A and GSM11.5(Y)A, a 24Ga or larger wire is required on the end product in order to meet current restrictions on the connector.
CERTIFICATION: All models are Certified to be in compliance with the applicable requirements of UL 60601-1, CSA 22.2 No. 601.1,
EN 60601-1, IEC 60601-1, UL 60950-1, CSA 60950-1 (L3M1), and EN 60950-1.
CLASSIFICATION:
(In accordance with
sub-clause 5
of IEC 60601-1)
(5.1) Protection against electric shock = Class II
(5.2) Degree of protection against electric shock = Signal output or intermediate
(5.3) Protection against harmful ingress of water = Ordinary (no protection)
(5.5) Have not been evaluated for use in the presence of a flammable anaesthetic mixture with air, oxygen, or
nitrous oxide. This evaluation is to be made on the end equipment by the OEM.
(5.6) Mode of operation = Continuous
SAFETY DECLARATION: Condor DC Power Supplies, Inc. declares under our sole responsibility that all models listed
above are in conformity with the applicable requirements of EN 60950-1 following the provisions of the Low Voltage
Directive 73/23/EEC.
OUTPUT: The output is not acceptable for direct patient connection without additional isolation. The DC output is SELV under normal
and single fault conditions.
OVERVOLTAGE PROTECTION: The output is monitored for an overvoltage condition. In some applications where an overvoltage
condition could result in a hazard as defined in applicable safety standards, redundant or additional overvoltage protection may be
required. Consult factory for details.
ISOLATION: The creepage distance between primary and secondary circuits is 8 mm minimum. The required creepage and clearance
distances from primary to secondary circuits must be maintained after installation to preserve the intended safety.
TEMPERATURES: The maximum operating temperatures of certain safety components, as defined in the applicable safety standards,
must not be exceeded after installation to preserve the intended safety. The output power, ambient air temperature and the availability,
amount, direction and/or restriction of airflow influence the temperatures of these components.
OVERCURRENT PROTECTION: There is only one internal fuse, located in the AC Line side, rated T 1A/250V.
WARNING! RISK OF FIRE! A blown internal fuse is an indication of catastrophic failure of circuit component(s). Repair must be
performed by Condor authorized personnel.
WARNING! SHOCK HAZARD! Dangerous voltages are present on some components and printed wiring traces.
CONNECTIONS
J1 Pin
AC Input
1
Line
3
Neutral
J3 Pin
J3 Pin
1
2
1
2
3
4
DC Output
Output (+)
Output (+)
Return
Return
MOUNTING & MATING INFORMATION
Refer to Condor Web site: www.condorpower.com
Condor DC Power Supplies Inc. will not be liable for the safety, reliability or performance of these power supplies if a) any changes, modifications or repairs are carried out by other
than authorized agents of Condor DC Power Supplies Inc., or b) the installation of the supply is not in accordance with these installation instructions and the applicable UL, CSA,
EN, and IEC safety standards.
41-35503-0001 Rev. D 05/10/06