GLC75 Multiple O/P Instructions

GLC75 MULTI-OUTPUT SERIES
INSTALLATION INSTRUCTIONS
SL POWER ELECTRONICS CORP.
6050 King Drive, Bldg. A
Ventura, CA 93003 + 805-486-4565
Internet: www.slpower.com
MODEL NUMBERS: GLC75X where X may be the letter A, B, C, D, E, F, H, J or P. Models may be followed by -CV,
-L, -LC, -V, -XXX and/or G. Suffix –CV indicates optional voltage adjust for output #1 and bracket/cover; -L indicates
optional L bracket; -LC indicates bracket/cover; -V indicates output adjust for output #1; -XXX indicates value added
configurations that have no impact on safety which may be any number from 001 thru 999; and/or G indicates compliance to
RoHS.
RATINGS:
Input: 100-240 V ac, 3.1 A, 50/60 Hz
Output: Maximum Continuous Power,
total of all outputs at ambient of 50 °C.
Output #1
MODEL
GLC75A
GLC75B
GLC75C
GLC75D
GLC75E
GLC75F
GLC75H
GLC75J
GLC75P
Notes:
+5.1 V
+5.1 V
+5.1 V
+5.1 V
+5.1 V
+5.1 V
+5.1 V
+5.1 V
+5.1 V
1.
2.
3.
4.
5.
Standard
26 CFM
0 CFM
110 Watts
75 Watts
Output #2
Note 1
Note 2
8A
8A
8A
8A
8A
8A
8A
8A
8A
10 A
10 A
10 A
10 A
10 A
10 A
10 A
10 A
10 A
+12 V
+12 V
+12 V
+24 V
+24 V
+15 V
+15 V
+12 V
+24 V
With Chassis/Cover (Note 3)
26 CFM
0 CFM
110 Watts
65 Watts
Output #3
Note 1
Note 2
2.5 A
2.5 A
2.5 A
2.5 A
2.5 A
2.5 A
2.5 A
2.5 A
4.0 A
3.0 A
3.0 A
3.0 A
2.5 A
2.5 A
3.0 A
3.0 A
3.0 A
4.0 A
-12 V
-5 V
-15 V
-12 V
-15 V
-5 V
-15 V
-12 V
-12 V
Output #4
Note 1
Note 2
1.0 A
1.0 A
1.0 A
1.0 A
1.0 A
1.0 A
1.0 A
1.0 A
1.0 A
1.0 A
1.0 A
1.0 A
1.0 A
1.0 A
1.0 A
1.0 A
1.0 A
1.0 A
+12 V
+12 V
+15 V
+12 V
+15 V
-15 V
+15 V
5V
+12 V
Note 1
Note 2
2.5 A
2.5 A
2.5 A
2.5 A
2.5 A
2.5 A
2.5 A
2.0 A
2.5 A
3.0 A
3.0 A
3.0 A
3.0 A
3.0 A
3.0 A
3.0 A
3.0 A
3.0 A
Maximum ratings for 0 CFM airflow without chassis/cover.
Maximum ratings for 26 CFM airflow.
Contact SL Power Electronics Corp Technical Support for airflow requirements when using chassis/cover option.
Maximum Operating Relative Humidity 96 %, no condensation.
Storage: -40 to +85 °C. Units should be allowed to warm-up under non-condensing conditions before application of power.
SAFETY DECLARATION: SL Power Electronics Corp. declares under our sole responsibility that all
models listed above are in conformity with the applicable requirements of EN 60950-1 following the provisions
of the Low Voltage Directive 73/23/EEC. All models are Certified to be in compliance with the applicable
requirements of UL 1950, CSA 22.2 No. 950-95 (Level 3), and EN 60950-1 for Pollution Degree 2 environment
and Class I TN-S power systems. The outputs of the supplies meet the requirements for SELV and are not an energy hazard.
GROUNDING: The Earth (ground) terminal J1, pin 1, must be bonded to Protective Earth in the end application to preserve
the intended safety. Using the Earth terminal on the supply for grounding the end product’s protective earthing terminal is
not recommended. A separate dedicated protective earthing point should be used.
SPACINGS: The required creepage and clearance distances from primary circuits to ground and secondary circuits must be
maintained after installation to preserve the intended safety.
TEMPERATURES: The maximum operating temperatures of certain safety components, as defined in the applicable safety
standards, must not be exceeded after installation to preserve the intended safety. The output power, ambient air temperature
and the availability, amount, direction and/or restriction of airflow influence the temperatures of these components.
WARNING! RISK OF FIRE! A blown internal fuse is an indication of catastrophic failure of circuit component(s).
Repair must be performed by SL Power Electronics Corp. authorized personnel. Refer to fuse marking on the supply for type
and rating.
WARNING! SHOCK HAZARD!
heatsinks.
Dangerous voltages are present on some components, printed wiring traces and
CONNECTIONS
J1 Pin
1
3
5
AC Input
Ground
Neutral
Line
J2 Pin
1,2,3
4,5,6,7
8,9
10
DC Output
Output #1 +
Common
Output #2 +
Power Fail
J2 Pin
11
12
13
DC Output
Output #3 Output #4 Output #4 +
MATING CONNECTORS
J1 - Amp Housing 640250-5
Pin 770522-1
J2 - Amp Housing 1-640250-3
Pin 770522-1
CAUTION: Do not exceed 5 A per contact.
SL Power Electronics Corp. will not be liable for the safety, reliability or performance of these power supplies if a) any changes, modifications or repairs are carried out by other than authorized agents of SL
Power Electronics Corp., or b) the installation of the supply is not in accordance with these installation instructions and the applicable UL, CSA, EN/IEC safety standards.
41-34203-0001 Rev. K 09/14/06