Condor Application Note 5/00 SAFETY AGENCY INFORMATION - MEDICAL AN-114 SAFETY AGENCY INFORMATION Medical Equipment, Including Dental Equipment Standard IEC/EN/CSA 60601-1 UL 60601-1 Earth Leakage Electric Strength Creepage Distance N.C. = 500 µA (6) Input to Ground = 1500 V ac (1) Input to Ground = 4 mm (2) Input to Output = 4000 V ac (1,3) Input to Output = 8 mm (2,3) N.C. = 300 µA (6) IEC ELECTROMAGNETIC COMPATIBILITY (EMC) DISTURBANCE Fundamental Definitions and Terms Description of Environment Compatibility Levels for Systems Radiated and Conducted Phenomena Compatibility Levels in Industrial Plants Limits for Harmonic Current Limitation Voltage Fluctuation/Flicker High Current Voltage Fluctuation/Flicker General Specification - Overview Electrostatic Discharge Test Radiated RFI Immunity Electrical Fast Transients/Burst Mains Surges Conducted RFI Harmonics and Inter-Harmonics Mains Frequency Magnetic Field Pulsed Magnetic Field Damped Oscillatory Magnetic Field Supply Voltage Dips and Interruptions Oscillatory Waves Immunity GENERAL IEC1000-1-1 IEC1000-2-1 IEC1000-2-2 IEC1000-2-3 IEC1000-2-4 IEC1000-3-2 IEC1000-3-3 IEC1000-3-5 IEC1000-4-1 IEC1000-4-2 IEC1000-4-3 IEC1000-4-4 IEC1000-4-5 IEC1000-4-6 IEC1000-4-7 IEC1000-4-8 IEC1000-4-9 IEC1000-4-10 IEC1000-4-11 IEC1000-4-12 Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 • Tel: 805-486-4565 • Fax: 805-487-8911• www.condorpower.com Condor Application Note 5/00 Information Technology Equipment, Including Electrical Business Equipment Standard Touch Current Electric Strength Creepage Distance IEC/EN/UL/CSA Handheld=0.75mA Input to Ground=1500Vac(4) Input to Ground=2.5mm(5) Movable = 3.5 mA Input to Output = 3000 V ac (3,4) Input to Output = 6.4 mm (3,5) 60950-1 Stationary = 3.5 mA NOTES 1. For measured voltages up to 250 V rms or dc. 2. For measured voltages up to 250 V rms or 300 V dc. 3. For SELV outputs. 4. For measured voltages up to 354 Vpk or dc. 5. For measured voltages up to 300 V rms or dc and based on Pollution Degree 2, Material Group III. 6. For single fault condition, maximum = 1 mA. HIPOT TESTING All Condor power supplies receive a hipot test to the following limits: Test Location Input to Ground Input to Output Output to Ground Test Voltage 1800 Vac or 1800 Vac or 500 Vdc 2500 2500 Vdc Vdc Note: Hipot tests can be a destructive test; especially when very high voltages are used. A catastrophic failure of the unit may result if a test voltage greater than 1800 Vac is applied between input and output circuits. The components providing the isolation from input to output cannot be tested while installed in the power supply without risk of damage to the unit. All components providing input to output isolation are tested using a minimum of 5000 V ac. Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 • Tel: 805-486-4565 • Fax: 805-487-8911• www.condorpower.com