GPFM600 Medical 600 Watt Global Performance Switchers FEATURES: • • • • • Small package (12.00” x 5.50” x 3.09”) Power factor corrected to EN61000-3-2 Class A Full load rating to 60°C 85 to 264 Vac Input Medically Approved to UL2601-1, IEC601-1, CSA C22.2 No. 601.1.2 • 2 year warranty • marked to LVD SPECIFICATIONS: Ac Input 85-264 Vac, 47-63 Hz single phase. Output Power Continuous output power, 600 watts. Hold-upTime 20 ms minimum from loss of ac input until output reaches 3% below nominal. Line and Load Regulation ±1% over the entire input voltage and frequency range, and over the entire output current range. Minimum Load No minimum load required. Overload Protection Current limit 105% minimum, 125% maximum of the specified full load current. Output Noise 50 mV pk-pk maximum. Transient Response Maximum of 5% change in Vout for a load change of 1.25 A. Recovers to ±1% within 500u sec. Overvoltage Protection Built in on all models. OVP crowbar reduces output voltage below nominal rating in less than 50 ms. Output voltage decay is dependent upon loading. Inrush Current Limit inrush current to 125% of maximum operating current. Turn on time of the power supply not to exceed 3 seconds over the full input voltage and frequency range. EMI/EMC Compliance All models include built-in EMI filtering to meet emissions requirements: EMI SPECIFICATIONS Conducted Emissions Static Discharge RF Field Susceptibility Fast Transients/Bursts Surge Susceptibility COMPLIANCE LEVEL EN55011 Class B; FCC Class B EN61000-4-2, 6 kV contact, 8 kV air EN61000-4-3, 3 V/meter EN61000-4-4, 2 kV, 5 kHz EN61000-4-5, 1 kV diff., 2 kV com. Vibration and Shock All models are to meet MIL-STD 810E, method 514.4 Category. Environmental Designed for 0 to 60°C operation at full rated output power; derate output current and total output power by 2.5% per °C above 50°C. Medical Leakage Current 150 µA under normal conditions. Maximum under single fault conditions, 250 µA. Patient sink leakage with 120 Vac, 60 Hz applied to any output with respect to the chassis will be less than 500 µA. Medical Safety Agency Approved to UL2601-1, EN60601-1-2, CSA C22.2 No. 601.1.2. DC Power Good Optocoupler isolated output indicates that the DC output is equal to or greater than 21.6 (-0 + 0.25) volts. This signal shall be driven when in the active ‘DC Good’ state. Efficiency Minimum of 75% under full load and input of 120 Vac 60 Hz. 112 Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 • 805-486-4565 • FAX 805-487-8911 • www.condorpower.com GPFM600 Medical 600 Watt Global Performance Switchers Commercial Model Output GPFM600-24 24 Vac Output Maximum(A) 25 A OVP Setpoint Total Regulation Noise P-P 25.8 ± 0.6 V 1% 100 mV GPFM600 MECHANICAL SPECIFICATIONS INPUT: J1 MOLEX P/N 43160-31-3 PIN 1: AC LINE PIN 2: AC NEUTRAL PIN 3: EARTH GROUND OUTPUT: J2 MOLEX P.N. 39-29-1147 14 PIN RIGHT ANGLE HEADER PIN 1: +24 V PIN 2: +24 V PIN 3: +24 V RETURN PIN 4: +24 V RETURN PIN 5: N/A PIN 6: AC GOOD PIN 7: AC GOOD RETURN PIN 8: +24 V PIN 9: +24 V PIN 10: +24 V RETURN PIN 11: +24 V RETURN PIN 12: N/A PIN 13: DC GOOD PIN 14: DC GOOD RETURN Environmental Specification Operating Non-operating Temperature (A) 0 to 60ºC -18 to +60ºC 0 to 97% RH 0 to 97% RH 20 gpk 40 gpk Humidity (A) Shock (B) Altitude Vibration (C) Dimensions: -500 to 10,000 ft 2 1.5 grms, 0.003 g /Hz -500 to 40,000 ft 5 grms, 0.026 g2/Hz Inches Millimeters A. Units should be allowed to warm up/operate under non-condensing conditions before application of power. Cooling provided by internal fan— heatsink temperatures should not exceed 90ºC for extended periods in the installation. B. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating. C. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogonal axes, total 6 shocks. Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 • 805-486-4565 • FAX 805-487-8911 • www.condorpower.com 113