OV-12/24 SERIES INSTALLATION INSTRUCTIONS

OV-12/24 SERIES
INSTALLATION INSTRUCTIONS
2311 STATHAM PKWY
OXNARD, CA 93033 + 805-486-4565
Internet: www.condorpower.com
VOLTAGE ADJUSTMENT RANGE: 6.2 – 33VDC
ADJUSTMENT PROCEDURE:
1.
2.
3.
4.
5.
REFER TO CHART 1 FOR SUGGESTED OVP TRIGGER VOLTAGES.
CONNECT TEST CIRCUIT AS SHOWN IN FIGURE A. TEST VOLTAGE SOURCE MAY BE ANY
POWER SUPPLY WITH A SHORT CIRCUIT LIMIT OF LESS THAN 8 AMPS (OVP-12) OR 20 AMPS
(OVP-24).
ENERGIZE AND ADJUST THE TEST VOLTAGE SOURCE TO THE DESIRED OVP VOLTAGE.
ROTATE THE OVP ADJUSTMENT POT CCW (FROM ITS MAXIMUM CW POSITON) UNTIL THE OVP
FIRES AS INDICATED BY A BY A 1 VOLT READING ON M1. LEAVE THE POT IN THIS POSITION,
UNIT IS NOW READY FOR INSTALLATION INTO POWER SUPPLY.
BOLT THE OVP ONTO THE POWER SUPPLY USING THE MOUNTING HOLES PROVIDE. CONNECT
THE WHITE (+) LEAD TO THE POSITIVE OUTPUT AND THE BLACK (-) LEAD TO THE NEGATIVE
OUTPUT.
MODEL
OVP-12
OVP-24
INTERMITTENT
12A
30A
CONTINUOUS
8A
20A
CHART 1
POWER SUPPLY
OUTPUT VOLTAGE
5 VDC
6 VDC
12 VDC
15 VDC
18 VDC
20 VDC
24 VDC
DUAL +/-12 VDC
DUAL +/- 15 VDC
SUGGESTED OVP
TRIGGER VOLTAGE
6.2+/-0.4V
7V
14V
17V
21V
23V
27V
27V
33V
FIGURE A
CURRENT
LIMITED
POWER
SUPPLY
+
+
OVP-12
OR
OVP-24
M1
-
-
Condor DC Power Supplies Inc. will not be liable for the safety, reliability or performance of these power supplies if a) any changes, modifications or repairs are carried out by other