Reliability Data for Safety of Machinery Safety Components

Reliability Data for Safety of Machinery
Safety Components
OMRON Corporarion
23-May-2013
Contents of this document are subject to change without notice.
E-09 means *10-9.
Products
Model
Condition / Function
SIL
PFHd
PL
Category
MTTFd(Year)
DCavg (%)
B10d
E-STOP Switch
A22E series
Normally Closed contact
-
-
-
-
-
-
1.00E+05
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
E-STOP Switch
A165E series
Normally Closed contact
-
-
-
-
-
-
1.00E+05
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Door Switch
D4NS Series
Normally Closed contact
-
-
-
-
-
-
2.00E+06
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Door Switch
D4BS Series
Normally Closed contact
-
-
-
-
-
-
2.00E+06
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Door Switch
D4GS-N Series
Normally Closed contact
-
-
-
-
-
-
2.00E+06
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Door Switch
D4NL Series
Normally Closed contact
-
-
-
-
-
-
2.00E+06
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Door Switch
D4SL Series, D4SL-N
Series
Normally Closed contact
-
-
-
-
-
-
2.00E+06
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Door Switch
D4JL Series
Normally Closed contact
-
-
-
-
-
-
2.00E+06
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Door Switch
D4GL Series
Normally Closed contact
-
-
-
-
-
-
2.00E+06
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Door Switch
D4BL Series
Normally Closed contact
-
-
-
-
-
-
2.00E+06
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Door Hinge Switch
D4NH Series
Normally Closed contact
-
-
-
-
-
-
2.00E+07
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Limit Switch
D4N-**20
Normally Closed contact
-
-
-
-
-
-
2.00E+07
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Limit Switch
D4N-**22
Normally Closed contact
-
-
-
-
-
-
2.00E+07
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Limit Switch
D4N-**25
Normally Closed contact
-
-
-
-
-
-
2.00E+07
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Limit Switch
D4N-**26
Normally Closed contact
-
-
-
-
-
-
2.00E+07
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Limit Switch
D4N-**2G
Normally Closed contact
-
-
-
-
-
-
2.00E+07
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Limit Switch
D4N-**2H
Normally Closed contact
-
-
-
-
-
-
2.00E+07
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Limit Switch
D4N-**31
Normally Closed contact
-
-
-
-
-
-
2.00E+07
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Limit Switch
D4N-**32
Normally Closed contact
-
-
-
-
-
-
2.00E+07
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Limit Switch
D4N-**62
Normally Closed contact
-
-
-
-
-
-
2.00E+07
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Limit Switch
D4N-**72
Normally Closed contact
-
-
-
-
-
-
2.00E+07
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Limit Switch
D4B-**11N
Normally Closed contact
-
-
-
-
-
-
2.00E+07
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Limit Switch
D4B-**15N
Normally Closed contact
-
-
-
-
-
-
2.00E+07
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Limit Switch
D4B-**70N
Normally Closed contact
-
-
-
-
-
-
2.00E+07
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Limit Switch
D4B-**71N
Normally Closed contact
-
-
-
-
-
-
2.00E+07
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Limit Switch
D4F-*02
Normally Closed contact
-
-
-
-
-
-
2.00E+07
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Limit Switch
D4F-*20
Normally Closed contact
-
-
-
-
-
-
2.00E+07
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Limit Switch
D4N-**20R
Normally Closed contact
-
-
-
-
-
-
2.00E+07
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Limit Switch
D4N-**2GR
Normally Closed contact
-
-
-
-
-
-
2.00E+07
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Limit Switch
D4N-**2HR
Normally Closed contact
-
-
-
-
-
-
2.00E+07
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Limit Switch
D4N-**31R
Normally Closed contact
-
-
-
-
-
-
2.00E+07
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Limit Switch
D4N-**32R
Normally Closed contact
-
-
-
-
-
-
2.00E+07
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Limit Switch
D4N-**62R
Normally Closed contact
-
-
-
-
-
-
2.00E+07
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Limit Switch
D4N-**72R
Normally Closed contact
-
-
-
-
-
-
2.00E+07
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Enabling Switch
A4E
Enable output
-
-
-
-
-
-
1.00E+05
Enabling Grip Switch
A4EG
Built-in enabling switch (A4E) Enable Output
-
-
-
-
-
-
1.00E+05
Enabling Grip Switch
A4EG
Built-in E-Stop (A165E) NC contact *only A4EGBE2R041
-
-
-
-
-
-
1.00E+05
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Key Selector Switch
A22TK-2*L
Normally Closed contact
-
-
-
-
-
-
1.00E+05
Normally closed contact has a structure that conforms to IEC60947-5-1 (Direct opening mechanism) only when the key is turned to
right.
Key Selector Switch
A22TK-2*R
Normally Closed contact
-
-
-
-
-
-
1.00E+05
Normally closed contact has a structure that conforms to IEC60947-5-1 (Direct opening mechanism) only when the key is turned to left.
1 / 3 page
Note
The enabling output has a structure that conforms to IEC60947-5-8 (Three-position enabling switch).
The enabling output has a structure that conforms to IEC60947-5-1 (Direct Opening Mechanism) only when the switch is gripped.
The enabling output has a structure that conforms to IEC60947-5-8 (Three-position enabling switch).
Enabling outputs conform to IEC60947-5-1 (Direct Opening Mechanism) only when the switch is gripped.
Reliability Data for Safety of Machinery
Safety Components
OMRON Corporarion
23-May-2013
Products
Model
Condition / Function
SIL
PFHd
Contents of this document are subject to change without notice.
E-09 means *10-9.
PL
Category
MTTFd(Year)
DCavg (%)
B10d
Non-conntact Door Switch
D40Z
Safety Output
SIL3
1.50E-10
e
4
-
-
-
Non-conntact Door Switch
D40A
Safety Output
SIL2
2.40E-09
d
3
-
-
-
SIL3
1.70E-08
e
4
-
-
-
SIL3
2.50E-08
e
4
-
-
-
SIL3
3.30E-08
e
4
-
-
-
SIL3
4.00E-08
e
4
-
-
-
SIL3
4.50E-08
e
4
-
-
-
SIL3
2.00E-08
e
4
-
-
-
SIL3
2.70E-08
e
4
-
-
-
SIL3
3.50E-08
e
4
-
-
-
SIL3
1.70E-08
e
4
-
-
-
SIL3
2.50E-08
e
4
-
-
-
SIL3
3.30E-08
e
4
-
-
-
SIL3
4.00E-08
e
4
-
-
-
SIL3
2.00E-08
e
4
-
-
-
SIL3
2.70E-08
e
4
-
-
-
SIL3
3.50E-08
e
4
-
-
-
SIL3
4.30E-08
e
4
-
-
-
SIL3
1.70E-08
e
4
-
-
-
SIL3
2.50E-08
e
4
-
-
-
SIL3
3.30E-08
e
4
-
-
-
SIL3
2.00E-08
e
4
-
-
-
SIL3
2.70E-08
e
4
-
-
-
SIL3
3.50E-08
e
4
-
-
-
SIL3
1.70E-08
e
4
-
-
-
SIL3
2.50E-08
e
4
-
-
-
SIL3
2.00E-08
e
4
-
-
-
SIL3
2.70E-08
e
4
-
-
-
SIL3
1.70E-08
e
4
-
-
-
SIL3
2.00E-08
e
4
-
-
-
SIL3
1.20E-08
e
4
-
-
-
SIL3
1.80E-08
e
4
-
-
-
SIL3
1.20E-08
e
4
-
-
-
SIL3
1.90E-08
e
4
-
-
-
SIL3
1.20E-08
e
4
-
-
-
SIL3
1.20E-08
e
4
-
-
-
SIL3
1.40E-08
e
4
-
-
-
SIL3
2.10E-08
e
4
-
-
-
SIL3
5.90E-08
e
4
-
-
-
Safety Light Curtain
Safety Light Curtain
Safety Light Curtain
Safety Light Curtain
Safety Light Curtain
Safety Light Curtain
Safety Light Curtain
Safety Light Curtain
Safety Light Curtain
Safety Light Curtain
Safety Light Curtain
Safety Light Curtain
Safety Light Curtain
Safety Light Curtain
Safety Light Curtain
Safety Light Curtain
Safety Light Curtain
Safety Light Curtain
Safety Light Curtain
Safety Light Curtain
Safety Light Curtain
Safety Light Curtain
Safety Light Curtain
Safety Light Curtain
Safety Light Curtain
Safety Light Curtain
Safety Light Curtain
Safety Light Curtain
Safety Light Curtain
Safety Light Curtain
Safety Light Curtain
Safety Light Curtain
Safety Light Curtain
Safety Light Curtain
Safety Light Curtain
Safety Light Curtain
Safety Light Curtain
F3SJ-A0245P14 to
A0461P14
F3SJ-A0533P14 to
A0875P14
F3SJ-A0983P14 to
A1271P14
F3SJ-A1487P14 to
A1631P14
F3SJ-A1784P14
F3SJ-A0245N14 to
A0461N14
F3SJ-A0551N14 to
A0911N14
F3SJ-A0983N14 to
A1271N14
F3SJ-A0245P20 to
A0755P20
F3SJ-A0785P20 to
A1505P20
F3SJ-A1565P20 to
A2255P20
F3SJ-A2405P20 to
A2495P20
F3SJ-A0245N20 to
A0755N20
F3SJ-A0785N20 to
A1505N20
F3SJ-A1655N20 to
A2255N20
F3SJ-A2405N20 to
A2495N20
F3SJ-A0260P25 to
A0940P25
F3SJ-A1020P25 to
A1900P25
F3SJ-A2060P25 to
A2500P25
F3SJ-A0260N25 to
A0940N25
F3SJ-A1020N25 to
A1900N25
F3SJ-A2060N25 to
A2500N25
F3SJ-A0245P30 to
A1195P30
F3SJ-A1270P30 to
A2495P30
F3SJ-A0245N30 to
A1195N30
F3SJ-A1270N30 to
A2495N30
F3SJ-A0270P55 to
A2470P55
F3SJ-A0270N55 to
A2470N55
F3SJ-B0185P25 to
B1025P25
F3SJ-B1105P25 to
B2065P25
F3SJ-B0185N25 to
B1025N25
F3SJ-B1105N25 to
B2065N25
F3SJ-E0185P25 to
E1105P25
F3SJ-E0185N25 to
E1105N25
F3SR-430B0190 to
430B0990
F3SR-430B1070 to
430B2270
MS4800 series
2 / 3 page
Note
A non-contact door switch alone conforms as a subsystem to IEC61508 SIL3. The reliability of the whole system is determined upon it
being combined with a connected dedicated controller (G9SX-NS* or G9SP series).
A non-contact door switch alone conforms as a subsystem to IEC61508 SIL2. The reliability of the whole system is determined upon it
being combined with a connected dedicated controller (G9SX-NS* or G9SP series).
The data is applicable for the models with a protective hight from 245 to 461mm.
It comforms to IEC 61496-1 TYPE4. As subsystem, it conforms to IEC61508 SIL3 and ISO13849-1 PLe.
The data is applicable for the models with a protective hight from 533 to 875mm.
It comforms to IEC 61496-1 TYPE4. As subsystem, it conforms to IEC61508 SIL3 and ISO13849-1 PLe.
The data is applicable for the models with a protective hight from 983 to 1271mm.
It comforms to IEC 61496-1 TYPE4. As subsystem, it conforms to IEC61508 SIL3 and ISO13849-1 PLe.
The data is applicable for the models with a protective hight from 1487 to 1631mm.
It comforms to IEC 61496-1 TYPE4. As subsystem, it conforms to IEC61508 SIL3 and ISO13849-1 PLe.
The data is applicable for the models with a protective hight 1784mm.
It comforms to IEC 61496-1 TYPE4. As subsystem, it conforms to IEC61508 SIL3 and ISO13849-1 PLe.
The data is applicable for the models with a protective hight from 245 to 461mm.
It comforms to IEC 61496-1 TYPE4. As subsystem, it conforms to IEC61508 SIL3 and ISO13849-1 PLe.
The data is applicable for the models with a protective hight from 551 to 911mm.
It comforms to IEC 61496-1 TYPE4. As subsystem, it conforms to IEC61508 SIL3 and ISO13849-1 PLe.
The data is applicable for the models with a protective hight from 983 to 1271mm.
It comforms to IEC 61496-1 TYPE4. As subsystem, it conforms to IEC61508 SIL3 and ISO13849-1 PLe.
The data is applicable for the models with a protective hight from 245 to 755mm.
It comforms to IEC 61496-1 TYPE4. As subsystem, it conforms to IEC61508 SIL3 and ISO13849-1 PLe.
The data is applicable for the models with a protective hight from 770 to 1505mm.
It comforms to IEC 61496-1 TYPE4. As subsystem, it conforms to IEC61508 SIL3 and ISO13849-1 PLe.
The data is applicable for the models with a protective hight from 1565 to 2255mm.
It comforms to IEC 61496-1 TYPE4. As subsystem, it conforms to IEC61508 SIL3 and ISO13849-1 PLe.
The data is applicable for the models with a protective hight from 2405 to 2495mm.
It comforms to IEC 61496-1 TYPE4. As subsystem, it conforms to IEC61508 SIL3 and ISO13849-1 PLe.
The data is applicable for the models with a protective hight from 245 to 755mm.
It comforms to IEC 61496-1 TYPE4. As subsystem, it conforms to IEC61508 SIL3 and ISO13849-1 PLe.
The data is applicable for the models with a protective hight from 785 to 1505mm.
It comforms to IEC 61496-1 TYPE4. As subsystem, it conforms to IEC61508 SIL3 and ISO13849-1 PLe.
The data is applicable for the models with a protective hight from 1655 to 2255mm.
It comforms to IEC 61496-1 TYPE4. As subsystem, it conforms to IEC61508 SIL3 and ISO13849-1 PLe.
The data is applicable for the models with a protective hight from 2405 to 2495mm.
It comforms to IEC 61496-1 TYPE4. As subsystem, it conforms to IEC61508 SIL3 and ISO13849-1 PLe.
The data is applicable for the models with a protective hight from 260 to 940mm.
It comforms to IEC 61496-1 TYPE4. As subsystem, it conforms to IEC61508 SIL3 and ISO13849-1 PLe.
The data is applicable for the models with a protective hight from 1020 to 1900mm.
It comforms to IEC 61496-1 TYPE4. As subsystem, it conforms to IEC61508 SIL3 and ISO13849-1 PLe.
The data is applicable for the models with a protective hight from 2060 to 2500mm.
It comforms to IEC 61496-1 TYPE4. As subsystem, it conforms to IEC61508 SIL3 and ISO13849-1 PLe.
The data is applicable for the models with a protective hight from 260 to 940mm.
It comforms to IEC 61496-1 TYPE4. As subsystem, it conforms to IEC61508 SIL3 and ISO13849-1 PLe.
The data is applicable for the models with a protective hight from 1020 to 1900mm.
It comforms to IEC 61496-1 TYPE4. As subsystem, it conforms to IEC61508 SIL3 and ISO13849-1 PLe.
The data is applicable for the models with a protective hight from 2060 to 2500mm.
It comforms to IEC 61496-1 TYPE4. As subsystem, it conforms to IEC61508 SIL3 and ISO13849-1 PLe.
The data is applicable for the models with a protective hight from 245 to 1195mm.
It comforms to IEC 61496-1 TYPE4. As subsystem, it conforms to IEC61508 SIL3 and ISO13849-1 PLe.
The data is applicable for the models with a protective hight from 1270 to 2495mm.
It comforms to IEC 61496-1 TYPE4. As subsystem, it conforms to IEC61508 SIL3 and ISO13849-1 PLe.
The data is applicable for the models with a protective hight from 245 to 1195mm.
It comforms to IEC 61496-1 TYPE4. As subsystem, it conforms to IEC61508 SIL3 and ISO13849-1 PLe.
The data is applicable for the models with a protective hight from 1270 to 2495mm.
It comforms to IEC 61496-1 TYPE4. As subsystem, it conforms to IEC61508 SIL3 and ISO13849-1 PLe.
The data is applicable for the models with a protective hight from 270 to 2470mm.
It comforms to IEC 61496-1 TYPE4. As subsystem, it conforms to IEC61508 SIL3 and ISO13849-1 PLe.
The data is applicable for the models with a protective hight from 270 to 2470mm.
It comforms to IEC 61496-1 TYPE4. As subsystem, it conforms to IEC61508 SIL3 and ISO13849-1 PLe.
The data is applicable for the models with a protective hight from 185 to 1025mm.
It comforms to IEC 61496-1 TYPE4. As subsystem, it conforms to IEC61508 SIL3 and ISO13849-1 PLe.
The data is applicable for the models with a protective hight from 1105 to 2065mm.
It comforms to IEC 61496-1 TYPE4. As subsystem, it conforms to IEC61508 SIL3 and ISO13849-1 PLe.
The data is applicable for the models with a protective hight from 185 to 1025mm.
It comforms to IEC 61496-1 TYPE4. As subsystem, it conforms to IEC61508 SIL3 and ISO13849-1 PLe.
The data is applicable for the models with a protective hight from 1105 to 2065mm.
It comforms to IEC 61496-1 TYPE4. As subsystem, it conforms to IEC61508 SIL3 and ISO13849-1 PLe.
The data is applicable for all models.
It comforms to IEC 61496-1 TYPE4. As subsystem, it conforms to IEC61508 SIL3 and ISO13849-1 PLe.
The data is applicable for all models.
It comforms to IEC 61496-1 TYPE4. As subsystem, it conforms to IEC61508 SIL3 and ISO13849-1 PLe.
The data is applicable for the models with a protective hight from 190 to 990mm.
It comforms to IEC 61496-1 TYPE4. As subsystem, it conforms to IEC61508 SIL3 and ISO13849-1 PLe.
The data is applicable for the models with a protective hight from 1070 to 2270mm.
It comforms to IEC 61496-1 TYPE4. As subsystem, it conforms to IEC61508 SIL3 and ISO13849-1 PLe.
It comforms to IEC61508 SIL3 and IEC 61496-1 TYPE4
Reliability Data for Safety of Machinery
Safety Components
OMRON Corporarion
23-May-2013
Contents of this document are subject to change without notice.
E-09 means *10-9.
Products
Model
Condition / Function
SIL
PFHd
PL
Category
MTTFd(Year)
DCavg (%)
B10d
Safety Mat System
UM / MC3
Integrated system of mats and controller
SIL2
4.80E-08
d
3
-
-
-
When combined with a connected dedicated controller, it conforms to both ISO 13849-1 PLd and EN1760-1.
-
-
e
3
100
97
-
When combined with a connected dedicated controller, it conforms to both ISO 13849-1 PLe and EN1760-2.
SIL2
8.30E-08
d
3
-
-
-
As a subsystem, it conforms to IEC61508 SIL2.
Safety Edge and Edge Controller SGE / SCC
Integrated system of edge sensor and controller
Note
Safety Laser Scanner
OS32C
Safety Relay Unit
G9SA-301
-
-
e
4
100
99
-
As a subsystem, it conforms to ISO13849-1 PLe.
Safety Relay Unit
G9SA-300-SC
-
-
e
4
100
99
-
As a subsystem, it conforms to ISO13849-1 PLe.
Safety Relay Unit
G9SA-501
-
-
e
4
100
99
-
As a subsystem, it conforms to ISO13849-1 PLe.
Safety Relay Unit
G9SA-321-T
Instantaneous Safety Output
-
-
e
4
82
99
-
As a subsystem, it conforms to ISO13849-1 PLe.
Safety Relay Unit
G9SA-321-T
Release delayed safety output
-
-
d
3
62
60
-
As a subsystem, it conforms to ISO13849-1 PLd.
Safety Relay Unit
G9SA-TH301
-
-
e
4
86
99
-
It has a structure of a controller, when combined with the Two-Hand Control Device that conforms to EN574 Type III.
As a subsystem, it conforms to ISO13849-1 PLe.
Safety Relay Unit
G9SB series (except G9SB3010)
-
-
e
4
100
99
-
As a subsystem, it conforms to ISO13849-1 PLe.
Safety Relay Unit
G9SB-3010
-
-
d
3
100
99
-
As a subsystem, it conforms to ISO13849-1 PLd.
Flexible Safety Unit
G9SX-BC
SIL3
4.10E-09
e
4
-
-
-
As a subsystem, it conforms to IEC61508 SIL3.
Flexible Safety Unit
G9SX-AD
SIL3
5.70E-09
e
4
-
-
-
As a subsystem, it conforms to IEC61508 SIL3.
Flexible Safety Unit
G9SX-ADA
SIL3
5.70E-09
e
4
-
-
-
As a subsystem, it conforms to IEC61508 SIL3.
Flexible Safety Unit
G9SX-EX
SIL3
5.80E-11
e
4
-
-
-
As a subsystem, it conforms to IEC61508 SIL3.
-
-
d
3
50
86
-
As a subsystem integrated with the E2E (E2E-X1R5F1, -X2MF1, -X2F1, -X5MF1, -X5F1, -X10MF1), it conforms to ISO13849-1 PLd.
SIL3
1.20E-08
d
3
-
-
-
As a subsystem, the G9SX-LM alone conforms to ISO13849-1 PLd. The DC of the proximity sensor to be connected to the rotation
detection input is 90%.
Low-speed Monitoring Unit
G9SX-LM
Integrated system of G9SX-LM and E2E proximity
sensor
Low-speed Monitoring Unit
G9SX-LM
Without proximity sensor
Standstill Monitoring Unit
G9SX-SM
SIL3
4.80E-09
e
4
-
-
-
As a subsystem, it conforms to IEC61508 SIL3.
Flexible Safety Unit
G9SX-GS
SIL3
9.00E-09
e
4
-
-
-
As a subsystem, it conforms to IEC61508 SIL3.
Flexible Safety Unit
G9SX-NS
Noncontact switch input (D40A or D40Z)
SIL3
4.20E-09
e
4
-
-
-
Flexible Safety Unit
G9SX-NSA
Noncontact switch input (D40A or D40Z)
SIL3
5.50E-09
e
4
-
-
-
Safety Network Controller
G9SP-N10S
SIL3
9.40E-11
e
4
-
-
-
As a subsystem, it conforms to IEC61508 SIL3.
Safety Network Controller
G9SP-N10D
SIL3
1.20E-10
e
4
-
-
-
As a subsystem, it conforms to IEC61508 SIL3.
Safety Network Controller
G9SP-N20S
SIL3
1.10E-10
e
4
-
-
-
As a subsystem, it conforms to IEC61508 SIL3.
Safety Network Controller
NE1A-SCPU01-V1
SIL3
5.10E-10
e
4
-
-
-
As a subsystem, it conforms to IEC61508 SIL3.
Safety Network Controller
NE1A-SCPU02
SIL3
6.50E-10
e
4
-
-
-
As a subsystem, it conforms to IEC61508 SIL3.
Safety Network Controller
DST1-ID12SL-1
SIL3
2.40E-10
e
4
-
-
-
As a subsystem, it conforms to IEC61508 SIL3.
Safety Network Controller
DST1-MD16SL-1
SIL3
2.40E-10
e
4
-
-
-
As a subsystem, it conforms to IEC61508 SIL3.
Safety Network Controller
DST1-XD0808SL-1
SIL3
2.40E-10
e
4
-
-
-
As a subsystem, it conforms to IEC61508 SIL3.
Safety Network Controller
DST1-MRD08SL-1
SIL3
5.10E-09
e
4
-
-
-
As a subsystem, it conforms to IEC61508 SIL3.
AC Servo Driver G5 Series
R88D-KT/KN
STO function (STO input and EDM output)
SIL2
2.80E-08
d
3
-
-
-
It has a structure that conforms to IEC61800-5-2 STO function. As a subsystem, it conforms to IEC61508 SIL2.
Frequency Inverter MX2 Series
3G3MX2
Stop function in conformity to Stop Category 0
-
-
d
3
100
71
-
It has a structure that conforms to IEC60204-1 Stop Category 0. As a subsystem, it comforms to ISO13849-1 PLd.
3 / 3 page
As a subsystem, it conforms to IEC61508 SIL3. The PL of the whole system is determined upon it being combined with a non-contact
switch (D40Z or D40A).
As a subsystem, it conforms to IEC61508 SIL3. The PL of the whole system is determined upon it being combined with a non-contact
switch (D40Z or D40A).