Reliability Data for Safety of Machinery Safety Components OMRON Corporarion 4-Jul-11 Contents of this document are subject to change without notice. Products Model Condition / Function SIL PFHd PL Category MTTFd(Year) DCavg (%) B10d Note E-STOP Switch A22E series Normally Closed contact - - - - - - 1.00E+05 Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism). E-STOP Switch A165E series Normally Closed contact - - - - - - 1.00E+05 Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism). Safety Door Switch D4NS Series Normally Closed contact - - - - - - 2.00E+06 Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism). Safety Door Switch D4BS Series Normally Closed contact - - - - - - 2.00E+06 Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism). Safety Door Switch D4GS-N Series Normally Closed contact - - - - - - 2.00E+06 Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism). Safety Door Switch D4NL Series Normally Closed contact - - - - - - 2.00E+06 Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism). Safety Door Switch D4SL Series Normally Closed contact - - - - - - 2.00E+06 Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism). Safety Door Switch D4JL Series Normally Closed contact - - - - - - 2.00E+06 Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism). Safety Door Switch D4GL Series Normally Closed contact - - - - - - 2.00E+06 Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism). Safety Door Switch D4BL Series Normally Closed contact - - - - - - 2.00E+06 Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism). Safety Door Hinge Switch D4NH Series Normally Closed contact - - - - - - 2.00E+07 Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism). Safety Limit Switch D4N-**20 Normally Closed contact - - - - - - 2.00E+07 Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism). Safety Limit Switch D4N-**22 Normally Closed contact - - - - - - 2.00E+07 Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism). Safety Limit Switch D4N-**25 Normally Closed contact - - - - - - 2.00E+07 Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism). Safety Limit Switch D4N-**26 Normally Closed contact - - - - - - 2.00E+07 Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism). Safety Limit Switch D4N-**2G Normally Closed contact - - - - - - 2.00E+07 Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism). Safety Limit Switch D4N-**2H Normally Closed contact - - - - - - 2.00E+07 Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism). Safety Limit Switch D4N-**31 Normally Closed contact - - - - - - 2.00E+07 Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism). Safety Limit Switch D4N-**32 Normally Closed contact - - - - - - 2.00E+07 Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism). Safety Limit Switch D4N-**62 Normally Closed contact - - - - - - 2.00E+07 Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism). Safety Limit Switch D4N-**72 Normally Closed contact - - - - - - 2.00E+07 Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism). Safety Limit Switch D4B-**11N Normally Closed contact - - - - - - 2.00E+07 Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism). Safety Limit Switch D4B-**15N Normally Closed contact - - - - - - 2.00E+07 Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism). Safety Limit Switch D4B-**70N Normally Closed contact - - - - - - 2.00E+07 Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism). Safety Limit Switch D4B-**71N Normally Closed contact - - - - - - 2.00E+07 Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism). Safety Limit Switch D4F-*02 Normally Closed contact - - - - - - 2.00E+07 Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism). Safety Limit Switch D4F-*20 Normally Closed contact - - - - - - 2.00E+07 Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism). Safety Limit Switch D4N-**20R Normally Closed contact - - - - - - 2.00E+07 Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism). Safety Limit Switch D4N-**2GR Normally Closed contact - - - - - - 2.00E+07 Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism). Safety Limit Switch D4N-**2HR Normally Closed contact - - - - - - 2.00E+07 Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism). Safety Limit Switch D4N-**31R Normally Closed contact - - - - - - 2.00E+07 Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism). Safety Limit Switch D4N-**32R Normally Closed contact - - - - - - 2.00E+07 Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism). Safety Limit Switch D4N-**62R Normally Closed contact - - - - - - 2.00E+07 Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism). Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism). Safety Limit Switch D4N-**72R Normally Closed contact - - - - - - 2.00E+07 Enabling Switch A4E Enable output - - - - - - 1.00E+05 Enabling Grip Switch A4EG Built-in enabling switch (A4E) Enable Output - - - - - - 1.00E+05 Enabling Grip Switch A4EG Built-in E-Stop (A165E) NC contact *only A4EGBE2R041 - - - - - - 1.00E+05 Normally closed contact conforms to IEC60947-5-1 (Direct opening Mechanism). Key Selector Switch A22TK-2*L Normally Closed contact - - - - - - 1.00E+05 Normally closed contact has a structure that conforms to IEC60947-5-1 (Direct opening mechanism) only when the key is turned to right. Normally closed contact has a structure that conforms to IEC60947-5-1 (Direct opening mechanism) only when the key is turned to left. Key Selector Switch A22TK-2*R Normally Closed contact - - - - - - 1.00E+05 Non-conntact Door Switch D40Z Safety Output SIL3 1.50E-10 e 4 - - - Non-conntact Door Switch D40A Safety Output SIL2 2.40E-09 d 3 - - - Safety Light Curtain MS4800 series SIL3 5.90E-08 e 4 - - - Safety Mat System MC3 / UM Safety Edge and Edge Controller SGE / CC The enabling output has a structure that conforms to IEC60947-5-8 (Three-position enabling switch). The enabling output has a structure that conforms to IEC60947-5-1 (Direct opening mechanism) only when the switch is gripped The enabling output has a structure that conforms to IEC60947-5-8 (Three-position enabling switch). Enabling outputs conform to IEC60947-5-1 (Direct opening) only when the switch is gripped A non-contact door switch alone conforms as a subsystem to IEC61508 SIL3. The reliability of the whole system is determined upon it being combined with a connected dedicated controller (G9SX-NS* or G9SP series) A non-contact door switch alone conforms as a subsystem to IEC61508 SIL2. The reliability of the whole system is determined upon it being combined with a connected dedicated controller (G9SX-NS* or G9SP series) It comforms to IEC61508 SIL3 and IEC 61496-1 TYPE4 Integrated system of mats and controller - - d 3 93 90 - When combined with a connected dedicated controller, it conforms to both ISO 13849-1 PLd and EN1760-1. Integrated system of edge sensor and controller - - e 3 100 97 - When combined with a connected dedicated controller, it conforms to both ISO 13849-1 PLe and EN1760-2. 1 / 2 page Reliability Data for Safety of Machinery Safety Components OMRON Corporarion 4-Jul-11 Products Model Safety Laser Scanner OS32C Safety Relay Unit Safety Relay Unit Condition / Function Contents of this document are subject to change without notice. SIL PFHd PL Category MTTFd(Year) DCavg (%) B10d SIL2 8.30E-08 d 3 - - - As a subsystem, it conforms to IEC61508 SIL2. G9SA-301 - - e 4 100 99 - As a subsystem, it conforms to ISO13849-1 PLe. G9SA-300-SC - - e 4 100 99 - As a subsystem, it conforms to ISO13849-1 PLe. Safety Relay Unit G9SA-501 - - e 4 100 99 - As a subsystem, it conforms to ISO13849-1 PLe. Safety Relay Unit G9SA-321-T Instantaneous Safety Output - - e 4 100 99 - As a subsystem, it conforms to ISO13849-1 PLe. Safety Relay Unit G9SA-321-T Release delayed safety output - - d 3 68 99 - As a subsystem, it conforms to ISO13849-1 PLd. Safety Relay Unit G9SA-TH301 - - e 4 86 99 - It has a structure of a controller, when combined with the Two-Hand Control Device that conforms to EN574 Type III. As a subsystem, it conforms to ISO13849-1 PLe. Safety Relay Unit G9SB series (except G9SB3010) - - e 4 100 99 - As a subsystem, it conforms to ISO13849-1 PLe. Safety Relay Unit G9SB-3010 - - d 3 100 99 - As a subsystem, it conforms to ISO13849-1 PLd. Flexible Safety Unit G9SX-BC SIL3 4.10E-09 e 4 - - - As a subsystem, it conforms to IEC61508 SIL3. Flexible Safety Unit G9SX-AD SIL3 5.70E-09 e 4 - - - As a subsystem, it conforms to IEC61508 SIL3. Flexible Safety Unit G9SX-ADA SIL3 5.70E-09 e 4 - - - As a subsystem, it conforms to IEC61508 SIL3. Flexible Safety Unit G9SX-EX SIL3 5.80E-11 e 4 - - - As a subsystem, it conforms to IEC61508 SIL3. Flexible Safety Unit G9SX-SM SIL3 4.80E-09 e 4 - - - As a subsystem, it conforms to IEC61508 SIL3. Flexible Safety Unit G9SX-GS SIL3 9.00E-09 e 4 - - - As a subsystem, it conforms to IEC61508 SIL3. Flexible Safety Unit G9SX-NS Noncontact switch input (D40A or D40Z) SIL3 4.20E-09 e 4 - - - Flexible Safety Unit G9SX-NSA Noncontact switch input (D40A or D40Z) SIL3 5.50E-09 e 4 - - - Safety Network Controller G9SP-N10S SIL3 9.40E-11 e 4 - - - As a subsystem, it conforms to IEC61508 SIL3. Safety Network Controller G9SP-N10D SIL3 1.20E-10 e 4 - - - As a subsystem, it conforms to IEC61508 SIL3. Safety Network Controller G9SP-N20S SIL3 1.10E-10 e 4 - - - As a subsystem, it conforms to IEC61508 SIL3. Safety Network Controller NE1A-SCPU01-V1 SIL3 5.10E-10 e 4 - - - As a subsystem, it conforms to IEC61508 SIL3. Safety Network Controller NE1A-SCPU02 SIL3 6.50E-10 e 4 - - - As a subsystem, it conforms to IEC61508 SIL3. Safety Network Controller DST1-ID12SL-1 SIL3 2.40E-10 e 4 - - - As a subsystem, it conforms to IEC61508 SIL3. Safety Network Controller DST1-MD16SL-1 SIL3 2.40E-10 e 4 - - - As a subsystem, it conforms to IEC61508 SIL3. Safety Network Controller DST1-XD0808SL-1 SIL3 2.40E-10 e 4 - - - As a subsystem, it conforms to IEC61508 SIL3. Safety Network Controller DST1-MRD08SL-1 SIL3 5.10E-09 e 4 - - - As a subsystem, it conforms to IEC61508 SIL3. AC Servo Driver G5 Series R88D-KT/KN STO function (STO input and EDM output) SIL2 2.80E-08 d 3 - - - It has a structure that conforms to IEC61800-5-2 STO function. As a subsystem, it conforms to IEC61508 SIL2. Frequency Inverter MX2 Series 3G3MX2 Stop function in conformity to Stop Category 0 - - d 3 100 71 - It has a structure that conforms to IEC60204-1 Stop Category 0. As a subsystem, it comforms to ISO13849-1 PLd. - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2 / 2 page Note As a subsystem, it conforms to IEC61508 SIL3. The PL of the whole system is determined upon it being combined with a non-contact switch (D40Z or D40A). As a subsystem, it conforms to IEC61508 SIL3. The PL of the whole system is determined upon it being combined with a non-contact switch (D40Z or D40A).