Reliability Data for Safety of Machinery Safety Components

Reliability Data for Safety of Machinery
Safety Components
OMRON Corporarion
4-Jul-11
Contents of this document are subject to change without notice.
Products
Model
Condition / Function
SIL
PFHd
PL
Category
MTTFd(Year)
DCavg (%)
B10d
Note
E-STOP Switch
A22E series
Normally Closed contact
-
-
-
-
-
-
1.00E+05
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
E-STOP Switch
A165E series
Normally Closed contact
-
-
-
-
-
-
1.00E+05
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Door Switch
D4NS Series
Normally Closed contact
-
-
-
-
-
-
2.00E+06
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Door Switch
D4BS Series
Normally Closed contact
-
-
-
-
-
-
2.00E+06
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Door Switch
D4GS-N Series
Normally Closed contact
-
-
-
-
-
-
2.00E+06
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Door Switch
D4NL Series
Normally Closed contact
-
-
-
-
-
-
2.00E+06
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Door Switch
D4SL Series
Normally Closed contact
-
-
-
-
-
-
2.00E+06
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Door Switch
D4JL Series
Normally Closed contact
-
-
-
-
-
-
2.00E+06
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Door Switch
D4GL Series
Normally Closed contact
-
-
-
-
-
-
2.00E+06
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Door Switch
D4BL Series
Normally Closed contact
-
-
-
-
-
-
2.00E+06
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Door Hinge Switch
D4NH Series
Normally Closed contact
-
-
-
-
-
-
2.00E+07
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Limit Switch
D4N-**20
Normally Closed contact
-
-
-
-
-
-
2.00E+07
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Limit Switch
D4N-**22
Normally Closed contact
-
-
-
-
-
-
2.00E+07
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Limit Switch
D4N-**25
Normally Closed contact
-
-
-
-
-
-
2.00E+07
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Limit Switch
D4N-**26
Normally Closed contact
-
-
-
-
-
-
2.00E+07
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Limit Switch
D4N-**2G
Normally Closed contact
-
-
-
-
-
-
2.00E+07
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Limit Switch
D4N-**2H
Normally Closed contact
-
-
-
-
-
-
2.00E+07
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Limit Switch
D4N-**31
Normally Closed contact
-
-
-
-
-
-
2.00E+07
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Limit Switch
D4N-**32
Normally Closed contact
-
-
-
-
-
-
2.00E+07
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Limit Switch
D4N-**62
Normally Closed contact
-
-
-
-
-
-
2.00E+07
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Limit Switch
D4N-**72
Normally Closed contact
-
-
-
-
-
-
2.00E+07
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Limit Switch
D4B-**11N
Normally Closed contact
-
-
-
-
-
-
2.00E+07
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Limit Switch
D4B-**15N
Normally Closed contact
-
-
-
-
-
-
2.00E+07
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Limit Switch
D4B-**70N
Normally Closed contact
-
-
-
-
-
-
2.00E+07
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Limit Switch
D4B-**71N
Normally Closed contact
-
-
-
-
-
-
2.00E+07
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Limit Switch
D4F-*02
Normally Closed contact
-
-
-
-
-
-
2.00E+07
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Limit Switch
D4F-*20
Normally Closed contact
-
-
-
-
-
-
2.00E+07
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Limit Switch
D4N-**20R
Normally Closed contact
-
-
-
-
-
-
2.00E+07
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Limit Switch
D4N-**2GR
Normally Closed contact
-
-
-
-
-
-
2.00E+07
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Limit Switch
D4N-**2HR
Normally Closed contact
-
-
-
-
-
-
2.00E+07
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Limit Switch
D4N-**31R
Normally Closed contact
-
-
-
-
-
-
2.00E+07
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Limit Switch
D4N-**32R
Normally Closed contact
-
-
-
-
-
-
2.00E+07
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Limit Switch
D4N-**62R
Normally Closed contact
-
-
-
-
-
-
2.00E+07
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Normally closed contact conforms to IEC60947-5-1 (Direct Opening Mechanism).
Safety Limit Switch
D4N-**72R
Normally Closed contact
-
-
-
-
-
-
2.00E+07
Enabling Switch
A4E
Enable output
-
-
-
-
-
-
1.00E+05
Enabling Grip Switch
A4EG
Built-in enabling switch (A4E) Enable Output
-
-
-
-
-
-
1.00E+05
Enabling Grip Switch
A4EG
Built-in E-Stop (A165E) NC contact *only A4EGBE2R041
-
-
-
-
-
-
1.00E+05
Normally closed contact conforms to IEC60947-5-1 (Direct opening Mechanism).
Key Selector Switch
A22TK-2*L
Normally Closed contact
-
-
-
-
-
-
1.00E+05
Normally closed contact has a structure that conforms to IEC60947-5-1 (Direct opening mechanism) only when the key is turned to right.
Normally closed contact has a structure that conforms to IEC60947-5-1 (Direct opening mechanism) only when the key is turned to left.
Key Selector Switch
A22TK-2*R
Normally Closed contact
-
-
-
-
-
-
1.00E+05
Non-conntact Door Switch
D40Z
Safety Output
SIL3
1.50E-10
e
4
-
-
-
Non-conntact Door Switch
D40A
Safety Output
SIL2
2.40E-09
d
3
-
-
-
Safety Light Curtain
MS4800 series
SIL3
5.90E-08
e
4
-
-
-
Safety Mat System
MC3 / UM
Safety Edge and Edge Controller SGE / CC
The enabling output has a structure that conforms to IEC60947-5-8 (Three-position enabling switch).
The enabling output has a structure that conforms to IEC60947-5-1 (Direct opening mechanism) only when the switch is gripped
The enabling output has a structure that conforms to IEC60947-5-8 (Three-position enabling switch).
Enabling outputs conform to IEC60947-5-1 (Direct opening) only when the switch is gripped
A non-contact door switch alone conforms as a subsystem to IEC61508 SIL3. The reliability of the whole system is determined upon it
being combined with a connected dedicated controller (G9SX-NS* or G9SP series)
A non-contact door switch alone conforms as a subsystem to IEC61508 SIL2. The reliability of the whole system is determined upon it
being combined with a connected dedicated controller (G9SX-NS* or G9SP series)
It comforms to IEC61508 SIL3 and IEC 61496-1 TYPE4
Integrated system of mats and controller
-
-
d
3
93
90
-
When combined with a connected dedicated controller, it conforms to both ISO 13849-1 PLd and EN1760-1.
Integrated system of edge sensor and controller
-
-
e
3
100
97
-
When combined with a connected dedicated controller, it conforms to both ISO 13849-1 PLe and EN1760-2.
1 / 2 page
Reliability Data for Safety of Machinery
Safety Components
OMRON Corporarion
4-Jul-11
Products
Model
Safety Laser Scanner
OS32C
Safety Relay Unit
Safety Relay Unit
Condition / Function
Contents of this document are subject to change without notice.
SIL
PFHd
PL
Category
MTTFd(Year)
DCavg (%)
B10d
SIL2
8.30E-08
d
3
-
-
-
As a subsystem, it conforms to IEC61508 SIL2.
G9SA-301
-
-
e
4
100
99
-
As a subsystem, it conforms to ISO13849-1 PLe.
G9SA-300-SC
-
-
e
4
100
99
-
As a subsystem, it conforms to ISO13849-1 PLe.
Safety Relay Unit
G9SA-501
-
-
e
4
100
99
-
As a subsystem, it conforms to ISO13849-1 PLe.
Safety Relay Unit
G9SA-321-T
Instantaneous Safety Output
-
-
e
4
100
99
-
As a subsystem, it conforms to ISO13849-1 PLe.
Safety Relay Unit
G9SA-321-T
Release delayed safety output
-
-
d
3
68
99
-
As a subsystem, it conforms to ISO13849-1 PLd.
Safety Relay Unit
G9SA-TH301
-
-
e
4
86
99
-
It has a structure of a controller, when combined with the Two-Hand Control Device that conforms to EN574 Type III.
As a subsystem, it conforms to ISO13849-1 PLe.
Safety Relay Unit
G9SB series (except G9SB3010)
-
-
e
4
100
99
-
As a subsystem, it conforms to ISO13849-1 PLe.
Safety Relay Unit
G9SB-3010
-
-
d
3
100
99
-
As a subsystem, it conforms to ISO13849-1 PLd.
Flexible Safety Unit
G9SX-BC
SIL3
4.10E-09
e
4
-
-
-
As a subsystem, it conforms to IEC61508 SIL3.
Flexible Safety Unit
G9SX-AD
SIL3
5.70E-09
e
4
-
-
-
As a subsystem, it conforms to IEC61508 SIL3.
Flexible Safety Unit
G9SX-ADA
SIL3
5.70E-09
e
4
-
-
-
As a subsystem, it conforms to IEC61508 SIL3.
Flexible Safety Unit
G9SX-EX
SIL3
5.80E-11
e
4
-
-
-
As a subsystem, it conforms to IEC61508 SIL3.
Flexible Safety Unit
G9SX-SM
SIL3
4.80E-09
e
4
-
-
-
As a subsystem, it conforms to IEC61508 SIL3.
Flexible Safety Unit
G9SX-GS
SIL3
9.00E-09
e
4
-
-
-
As a subsystem, it conforms to IEC61508 SIL3.
Flexible Safety Unit
G9SX-NS
Noncontact switch input (D40A or D40Z)
SIL3
4.20E-09
e
4
-
-
-
Flexible Safety Unit
G9SX-NSA
Noncontact switch input (D40A or D40Z)
SIL3
5.50E-09
e
4
-
-
-
Safety Network Controller
G9SP-N10S
SIL3
9.40E-11
e
4
-
-
-
As a subsystem, it conforms to IEC61508 SIL3.
Safety Network Controller
G9SP-N10D
SIL3
1.20E-10
e
4
-
-
-
As a subsystem, it conforms to IEC61508 SIL3.
Safety Network Controller
G9SP-N20S
SIL3
1.10E-10
e
4
-
-
-
As a subsystem, it conforms to IEC61508 SIL3.
Safety Network Controller
NE1A-SCPU01-V1
SIL3
5.10E-10
e
4
-
-
-
As a subsystem, it conforms to IEC61508 SIL3.
Safety Network Controller
NE1A-SCPU02
SIL3
6.50E-10
e
4
-
-
-
As a subsystem, it conforms to IEC61508 SIL3.
Safety Network Controller
DST1-ID12SL-1
SIL3
2.40E-10
e
4
-
-
-
As a subsystem, it conforms to IEC61508 SIL3.
Safety Network Controller
DST1-MD16SL-1
SIL3
2.40E-10
e
4
-
-
-
As a subsystem, it conforms to IEC61508 SIL3.
Safety Network Controller
DST1-XD0808SL-1
SIL3
2.40E-10
e
4
-
-
-
As a subsystem, it conforms to IEC61508 SIL3.
Safety Network Controller
DST1-MRD08SL-1
SIL3
5.10E-09
e
4
-
-
-
As a subsystem, it conforms to IEC61508 SIL3.
AC Servo Driver G5 Series
R88D-KT/KN
STO function (STO input and EDM output)
SIL2
2.80E-08
d
3
-
-
-
It has a structure that conforms to IEC61800-5-2 STO function. As a subsystem, it conforms to IEC61508 SIL2.
Frequency Inverter MX2 Series
3G3MX2
Stop function in conformity to Stop Category 0
-
-
d
3
100
71
-
It has a structure that conforms to IEC60204-1 Stop Category 0. As a subsystem, it comforms to ISO13849-1 PLd.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2 / 2 page
Note
As a subsystem, it conforms to IEC61508 SIL3. The PL of the whole system is determined upon it being combined with a non-contact
switch (D40Z or D40A).
As a subsystem, it conforms to IEC61508 SIL3. The PL of the whole system is determined upon it being combined with a non-contact
switch (D40Z or D40A).