New Product Digital Timer H5CZ Easy to Use and Easy to Read. Basic Features • Character height of 10 mm for better readability. • Operation is simplified by the Up/Down Keys for each digit on 4-digit. Safety and Reliability • Power supply circuit and input circuits are isolated for safety and reliability. • Set value limit function prevents unexpected operation of output devices caused by setting mistakes. • Output counter function helps in managing the service life of the Timer or the load. Other Features • Models with instantaneous contact output. • Waterproof, dust-proof structure (UL508 Type 4X and IP66). • Key protection. Refer to Safety Precautions on page 29. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Features Basic Features Set Value Limit Better Readability You can set an upper limit for the set value to prevent unexpected operation of output devices caused by setting mistakes. Character Height of 10 mm with a Wide Viewing Angle. Easy to read from the top, bottom, and sides. 10 mm (actual size) Worry-free operation is achieved with the H5CZ by restricting the time that can be set. Clear Confirmation Output Counter The output counter counts the number of times the output turns ON (alarm display, count monitoring, count in increments of 1,000). This counter is useful in managing the service life of the Timer or the load. The Easiest Operation Operation is simplified by the Up/Down Keys for each digit on 4-digit. Other Features Models with Instantaneous Contact Output Models with instantaneous contact outputs have been added for use with self-holding circuits and as auxiliary relays. These models are also convenient when replacing analog timers. Safety and Reliability Isolated Power Supply and Input Circuits *1 Power supply circuit and input circuits are isolated for safety and reliability. Previous non-isolated timers had wiring restrictions and could be damaged if wired incorrectly. The H5CZ removes these worries. COM terminal +V Note: When the Y92S-29 Waterproof Packing is used. Select from any of seven protection patterns. Use the best one for the application. 0-V terminal –V Worry-free application is possible in locations subject to water. Key Protection Output terminal on PLC or other device Input terminal AC power supply *2 Waterproof, Dust-proof Structure (UL508 Type 4X and IP66) Forget These Worries with the H5CZ New Modes Modes, such as a stopwatch mode (Mode S), have been added. Select any of 15 modes. Stabilized DC power supply *2. The AC power supply ground is on the commercial power supply side. *1. H5CZ with 100 to 240-VAC specifications. 1 H5CZ Model Number Structure Model Number Legend H5CZ-L @@@ ––– 1 2 3 1. External Connections 2. Output type 3. Supply voltage Symbol Meaning Symbol Meaning Symbol Meaning 8 8-pin socket None Contact output (time-limit SPDT) None 100 to 240 VAC 50/60 Hz E Contact output (time-limit SPDT + instantaneous SPDT) * D 12 to 24 VDC/24 VAC 50/60 Hz * Can be used as a time-limit DPDT output. Ordering Information List of Models Type H5CZ Time specifications 0.001 to 9.999 s 0.01 to 99.99 s 0.1 to 999.9 s 1 to 9999 s 1 s to 99 min 59 s 0.1 to 999.9 min 1 to 9999 min 1 min to 99 h 59 min 0.1 to 999.9 h 1 to 9999 h Operating modes External connections Timer Mode A: Signal ON Delay I A-1: Signal ON Delay II A-2: Power ON Delay I A-3: Power ON Delay II b: Repeat cycle 1 b-1: Repeat cycle 2 d: Signal OFF Delay E: Interval F: Cumulative Z: ON/OFF-duty-adjustable flicker S: Stopwatch Twin Timer Mode toff: Flicker OFF Start 1 ton: Flicker ON Start 1 toff-1: Flicker OFF Start 2 ton-1: Flicker ON Start 2 Timer Mode A-2: Power ON Delay I b: Repeat cycle 1 E: Interval Z: ON/OFF-duty-adjustable flicker Twin Timer Mode toff: Flicker OFF Start 1 ton: Flicker ON Start 1 Inputs Signal, Reset (NPN inputs) Outputs 100 to 240 VAC H5CZ-L8 12 to 24 VDC/ 24 VAC H5CZ-L8D Contact output (time-limit SPDT 100 to 240 VAC + instantaneous SPDT) Models with instantaneous 12 to 24 VDC/ contact outputs 24 VAC * Note: The functions that are provided depend on the model. Check detailed specifications before ordering. * A time-limit DPDT output can also be used. 2 Models Contact output (time-limit SPDT) 8-pin socket None Supply voltage H5CZ-L8E H5CZ-L8ED H5CZ Accessories (Order Separately) Soft Cover Models Page Y92A-48F1 9 Hard Cover Models Page Y92A-48 9 Flush Mounting Adapter Models Page Y92F-30 9 Waterproof Packing Models Page Y92S-29 9 Connection Sockets Models Type Remarks P2CF-08 Front Connecting Socket --- P2CF-08-E Front Connecting Socket (Finger-safe Type) Round crimp terminals cannot be used on Finger-safe Sockets. Use forked crimp terminals. Back Connecting Socket A Y92A-48G Terminal Cover can be used with the Socket to create a finger-safe construction. P3G-08 Page 10 Terminal Covers for P3G-08 Back-connecting Sockets Models Page Y92A-48G 10 3 H5CZ H5CZ Digital Timers Specifications Ratings Item Ratings Models H5CZ-L8@ Power supply voltage *1 • 100 to 240 VAC 50/60 Hz • 12 to 24 VDC/24 VAC 50/60 Hz Operating voltage fluctuation range 85% to 110% of rated supply voltage (90% to 110% at 12 to 24 VDC) Power consumption Approx. 6.2 VA at 100 to 240 VAC, Approx. 5.1 VA/2.4 W at 24 VAC/12 to 24 VDC *2 Mounting method Flush mounting, Surface mounting, DIN track mounting External connections 8-pin socket Degree of protection IEC IP66, UL508 Type 4X (indoors) for panel surface only and when Y92S-29 Waterproof Packing is used 4 digits Digits 0.001 s to 9.999 s, 0.01 s to 99.99 s, 0.1 s to 999.9 s, 1 s to 9999 s, 1 s to 99 min 59 s 0.1 m to 999.9 min, 1 min to 9999 min, 1 min to 99 h 59 min, 0.1 h to 999.9 h, 1 h to 9999 h Time ranges Timer mode Inputs Elapsed time (Up), Remaining time (Down) (selectable) Input signals Signal, Reset (no inputs on models with instantaneous contact outputs) Input method No-voltage Input ON impedance: 1 kΩ max. (Leakage current: 12 mA when 0 Ω) ON residual voltage: 3 V max. OFF impedance: 100 kΩ min. Signal, reset Minimum input signal width: 1 or 20 ms (selectable, same for all input) Reset system Power reset (depending on output mode), External reset, Manual reset, Automatic reset (depending on output mode) Power reset Minimum power-opening time: 0.5 s (except for A-3, b-1, F, ton-1, and toff-1 mode) Reset voltage 10% max. of rated supply voltage Sensor waiting time 250 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.) Output modes A: Signal ON Delay I, A-1: Signal ON Delay II, A-2: Power ON Delay I, A-3: Power ON Delay II, b: Repeat Cycle 1, b-1: Repeat Cycle 2, d: Signal OFF Delay, E: Interval, F: Cumulative, Z: ON/OFF-duty-adjustable flicker, S: Stopwatch, toff: Flicker OFF Start 1, ton: Flicker ON Start 1, toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2 One-shot output time 0.01 to 99.99 s Control output 5 A at 250 VAC/30 VDC, resistive load (cos =1) Minimum applied load: 10 mA at 5 VDC (failure level: P, reference value) Contact materials: AgSnIn Output Display method *3 LCD; Present value: 10-mm-high characters Set value: 6-mm-high characters Memory backup EEPROM (overwrites: 100,000 times min.) that can store data for 10 years min. Operating temperature range -10 to 55°C (-10 to 50°C if counters are mounted side by side) (with no icing or condensation) Storage temperature range -25 to 70°C (with no icing or condensation) Operating humidity range 25% to 85% Front panel color Light gray (5Y7/1) *1. Do not use the output from an inverter as the power supply. The ripple must be 20% maximum for DC power. *2. Inrush current will flow for a short time when the power supply is turned ON. Inrush Current (Reference Values) Voltage 100 to 240 VAC 12 to 24 VDC/24 VAC Applied voltage Inrush current (peak value) Time 264 VAC 5.3 A 0.4 ms 26.4 VAC 6.4 A 1.4 ms 26.4 VDC 4.4 A 1.7 ms *3. The display is lit only when the power is ON. Settings and changes are not possible if the power supply is not ON. 4 Models with Instantaneous Contact Outputs A-2: Power ON Delay I, b: Repeat Cycle 1, E: Interval, Z: ON/OFF-duty-adjustable flicker, toff: Flicker OFF Start 1, ton: Flicker ON Start 1 H5CZ Characteristics Power-ON start: ±0.01% ±50 ms max. (See note) Signal start: ±0.005%±0.03 ms max. (See note) If the set value is within the sensor waiting time at startup the control output of the H5CZ will not turn ON until the sensor waiting time passes. Note: The values are based on the set value. Insulation resistance 100 MΩ min. (at 500 VDC) between current-carrying terminal and exposed non-current-carrying metal parts, and between non-continuous contacts Dielectric strength 2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and non-current-carrying metal parts 2,000 VAC, 50/60 Hz for 1 min between power supply and input circuits for all models except H5CZ-@D 2,000 VAC, 50/60 Hz for 1 min between control output, power supply, and input circuits 1,000 VAC, 50/60 Hz for 1 min between non-continuous contacts Impulse withstand voltage Noise immunity Static immunity Malfunction: 8 kV Destruction: 15 kV Shock resistance Life expectancy Destruction 10 to 55 Hz with 0.75-mm single amplitude each in three directions for 2 h each Malfunction 10 to 55 Hz with 0.35-mm single amplitude each in three directions for 10 min each Destruction 300 m/s2 in three directions, three cycles Malfunction 100 m/s2 in three directions, three cycles Mechanical 10,000,000 operations min. (under no load at 1,800 operations/h and ambient temperature of 23°C) Electrical 100,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h and ambient temperature of 23°C) * Weight 1,000 500 100 DC30V L/R=7ms 50 AC250V/DC30V cosφ =1 5 kV (between power terminals) for 100 to 240 VAC, 1 kV for 24 VAC/12 to 24 VDC 5 kV (between current-carrying terminal and exposed non-currentcarrying metal parts) for 100 to 240 VAC 1.5 kV for 24 VAC/12 to 24 VDC ±1.5 kV (between power terminals) and ±600 V (between input terminals), square-wave noise by noise simulator (pulse width: 100 ns/ 1 µs, 1-ns rise) Vibration resistance Life-test Curve (Reference Values) Switching operations (× 104) Accuracy of operating time and setting error (including temperature and voltage influences) 10 AC250V cosφ =0.4 0 1 2 3 4 5 Load current (A) A maximum current of 0.15 A can be switched at 125 VDC (cosφ =1) and a maximum current of 0.1 A can be switched if L/R is 7 ms. In both cases, a life of 100,000 operations can be expected. Approx. 105 g (Timer only) * Refer to Life-test Curve. Applicable Standards Approved safety standards UL508/Listing, UL50 Type 4X for indoor use (enclosure rating), CSA C22.2 No. 14 *, conforms to EN61812-1 (Pollution degree 2/overvoltage category III) B300 PILOT DUTY 1/4 HP 120 VAC, 1/3 HP, 240 VAC, 5 A resistive load VDE0106/P100 CCC: Pollution degree 2, Overvoltage category II EMC (EMI) Emission Enclosure: Emission AC mains: (EMS) Immunity ESD: Immunity RF-interference: Immunity Burst: Immunity Surge: Immunity Conducted Disturbance: Immunity Voltage Dip/Interruption: EN61812-1 EN55011 Group 1 class A EN55011 Group 1 class A EN61812-1 IEC61000-4-2 IEC61000-4-3 IEC61000-4-4 IEC61000-4-5 IEC61000-4-6 IEC61000-4-11 * The following safety standards apply to H5CZ. cUL (Listing): Applicable when an OMRON P2CF (-E) Socket is used. cUR (Recognition): Applicable when any other socket is used. I/O Functions For details, refer to the timing charts on page 16 and page 25. Start signal Normally functions to start timing. In modes A-2 and A-3, disable timing. In mode S, starts and stops timing. Reset • Resets present value. (In elapsed time mode, the present value returns to 0; in remaining time mode, the present value returns to the set value.) • Count inputs are not accepted and control output turns OFF while reset input is ON. • Reset indicator is lit while reset input is ON. Control output (OUT) Outputs take place according to designated operating mode when timer reaches corresponding set value. Inputs * Outputs * The H5CZ-L8E@ does not have an input. 5 H5CZ Connections Block Diagram (Basic insulation) Output circuit Power supply circuit (See note.) (Basic insulation) Display circuit Internal control circuit Input circuits Key switch circuit Note: Basic insulation is provided between the power supply circuit and the input circuits. However, basic insulation is not provided in the H5CZ-@D. Terminal Arrangement Confirm that the power supply meets specifications before use. H5CZ-L8/-L8D H5CZ-L8E/-L8ED Internal circuit Internal circuit Internal circuit Signal 4 Reset 4 5 3 6 2 7 1 Instantaneous contact output OUT1 Contact output 5 3 6 2 7 8 1 8 (–) (+) Time-limit contact output OUT2 0V (-) Terminals 1 and 2 of the H5CZ-L8D are connected internally. (+) OUT1 can also be used as a time-limit contact output. Note: Do not connect unused terminals as relay terminals. Input Circuits Signal and Reset Input No-voltage Inputs (NPN Inputs) +14 V 1 kΩ Internal circuit IN Input Connections The inputs are no-voltage (closed or open). (The H5CZ-L8E@ does not have an input.) No-voltage Inputs (NPN Inputs) Open Collector Voltage Output PLC or sensor Contact Input 3 4 1 3 4 Note: Operate with transistor ON No-voltage Input Signal Levels No-contact input Short-circuit level Transistor ON • Residual voltage: 3 V max. • Impedance when ON: 1 kΩ max. (The leakage current is approx. 12 mA when the impedance is 0 Ω.) Open level Transistor OFF • Impedance when OFF: 100 kΩ min. Contact input Use contacts which can adequately switch 5 mA at 10 V Note: The DC voltage must be 30 VDC max. 1 3 4 Note: Operate with contacts ON. 1 Reset input 3 Signal input 0 V for inputs Signal input Reset input 0 V for inputs Signal input Reset input 0 V for inputs Reset input 0 V for inputs 1 Signal input Sensor Note: Operate with transistor ON 6 DC Two-wire Sensor 4 Note: Operate with transistor ON Applicable Two-wire Sensor • Leakage current: 1.5 mA max. • Switching capacity: 5 mA min. • Residual voltage: 3.0 VDC max. • Operating voltage: 10 VDC H5CZ Nomenclature Operation Key Display Section 4 1. Key Protect Indicator 2. Control Output Indicator 3. Reset Indicator 4. Present Value Display (Main display) (Character height: 10 mm) (Changes modes and setting items) 1 5 2 6 3 8 7 10. Up Keys 1 to 4 10 11 11. Down Keys 1 to 4 5. Time Unit Indicators (If the time range is 0 min, 0 h, 0.0 h, or 0 h 0 min, these indicators flash to indicate timing operation.) 9 Front View 6. Set Value Display (Sub-display) (Character height: 6 mm) Character Size for Present Value Display 10 mm 9. Reset Key (Resets present value and output) Switches 12. Key-protect Switch 12 7. Set Value 1, 2 Indicator 8. Mode Key (Default setting) OFF (Disabled) ON (Enabled) Character Size for Set Value Display 6 mm 7 H5CZ Dimensions (unit: mm) Digital Timers Digital Timers Panel Cutouts Panel cutouts areas shown below. (according to DIN43700). H5CZ-L8@ (Flush Mounting/Surface Mounting Models) 60 min. 48×48 6 45+0.6 0 14.2 63.7 45+0.6 0 15 min. 60 min. 44.8×44.8 Dimensions with Flush Mounting Adapter H5CZ-L8@ (Adapter and Waterproof Packing Ordered Separately) Y92S-29 (order separately) Panel Y92F-30 (order separately) P3G-08 (order Waterproof Packing Flush Mounting Adapter separately) Back-connecting Socket Note: 1. The mounting panel thickness should be 1 to 5 mm. 2. To allow easier operation, it is recommended that Adapters be mounted so that the gap between sides with hooks is at least 15 mm (i.e., with the panel cutouts separated by at least 60 mm). 3. It is possible to horizontally mount Timers side by side. Attach the Flush Mounting Adapters so that the surfaces without hooks are on the sides of the Timers. (However, if Timers are mounted side by side, water resistance will be lost.) n Units mounted side-by-side (51) 58 A A=(48n-2.5) 48 7.5 84.8 Dimensions with Front Connecting Socket * 92.3 H5CZ -L8@ 90 P2CF-08(-E) (order separately) Front Connecting Socket 8 * These dimensions vary with the type of DIN track (reference value). +1 –0 With Y92A-48F1 attached. A={48n-2.5+(n-1)×4} +1 –0 With Y92A-48 attached. +1 A = (51n - 5.5) –0 H5CZ Accessories (Order Separately) Note: Depending on the operating environment, the condition of resin products may deteriorate, and may shrink or become harder. Therefore, it is recommended that resin products are replaced regularly. Soft Cover Hard Cover Waterproof Packing Y92A-48F1 Y92A-48 Y92S-29 Protecting the Timer in Environments Subject to Oil The H5CZ's panel surface is water-resistive (IP@6, UL Type 4X) and so even if drops of water penetrate the gaps between the keys, there will be no adverse effect on internal circuits. If, however, there is a possibility of oil being present on the operator's hands, use the Soft Cover. The Soft Cover ensures protection equivalent to IP54 against oil. Do not, however, use the H5CZ in locations where it would come in direct contact with oil. Order this Waterproof Packing separately if it is required. The Waterproof Packing can be used to achieve IP66 protection. The Waterproof Packing will deteriorate, harden, and shrink depending on the application environment. To ensure maintaining the IP@6, UL Type 4X waterproof level, periodically replace the Waterproof Packing. The periodic replacement period will depend on the application environment. You must confirm the proper replacement period. Use 1 year or less as a guideline. If the Waterproof Packing is not replaced periodically, the waterproof level will not be maintained. It is not necessary to mount the Waterproof Packing if waterproof construction is not required. Flush Mounting Adapter Y92F-30 Order this Flush Mounting Adapter separately if it is required. 9 H5CZ Connection Sockets Front-connecting Sockets Model Terminal arrangement and internal connections Dimensions P2CF-08 Mounting hole dimensions 20.3 max. 50 max. Two, 4.5-dia. holes 70 max. 35.4 4 6 7.8 Eight, M3.5 x 7.5 sems screws 3 P2CF-08-E (Finger Safe Terminal) 5 4 3 Two, M4 or 4.5-dia. holes 4.5 40±0.2 21.5 max. 20.3 50 max. 40±0.2 19 7 8 1 2 (Top View) Two, 4.5-dia. holes 6 5 4 3 3 P2CF-08-E 70 max. 1.3 35.4 10A250VAC RESISTIVE 7 8 1 2 4 7.8 Eight, M3.5 x 7.5 set screws 5 4.5 Note: Round crimp terminals cannot be used on Finger-safe Sockets. Use forked crimp terminals. Back-connecting Sockets Model Terminal arrangement and internal connections Dimensions P3G-08 27 dia 3 4 5 6 2 1 8 7 45 4.9 45 17 (Bottom View) Note: A Y92A-48G Terminal Cover can be used with the Socket to create a finger-safe construction. Terminal Covers for P3G-08 Back-connecting Sockets Model Dimensions Y92A-48G Twelve, 6.4 dia 34 Y92A-48G UP 47.7×47.7 48×48 P C 16.5 24.6 27.6 47.4 Note: The Terminal Cover can be used with a Back-mounting Socket (P3G-08) to create a finger-safe construction. 10 Note: The Socket can also be mounted to DIN track. H5CZ Optional Products for Track Mounting Mounting Track PFP-100N PFP-50N 7.3±0.15 4.5 27±0.15 35±0.3 15 25 10 25 1,000 (500) * 25 10 15 (5) * 25 1 * The values shown in parentheses are for the PFP-50N. Mounting Track PFP-100N2 16 4.5 35±0.3 27 25 10 15 25 1,000 25 End Plate 10 25 29.2 24 1 15 1.5 10 6.2 PFP-M 1.8 M4 x 8 pan head screw 1 50 35.5 35.3 1.8 11.5 10 1.3 4.8 M4 spring washer Spacer PFP-S 16 12 5 34.8 44.3 16.5 Note: Order Spacers in increments of 10. 11 H5CZ Timer Operating Procedures Setting Procedure Guide Settings for Timer Operation * Use the following settings. Settings for Twin Timer Operation * Refer to page 22. * At the time of delivery, the H5CZ is set to the Timer configuration. Refer to page 25 for information on switching models. Operating Procedures for Timer Function • Change to Function Setting Mode. Power ON 3 s min. Run mode *1 For details on operations in run mode, refer to page 15. Function setting mode 3 s min. *2 *1. If the mode is switched to the function setting mode during operation, operation will continue. *2. Changes made to settings in function setting mode are enabled for the first time when the mode is changed to run mode. Also, when settings are changed, the timer is reset (time initialized and output turned OFF). The characters displayed in reverse video are the default settings. Set the time range using the keys. Time range Time Range List …… Display For details, refer to the Time Range List. Timer mode Set the timer mode using the up keys. 1 s to 9999 s (DOWN) Function setting mode Set the output mode using the Output modes 0.1 s to 999.9 s down (UP) 0 min 01 s to 99 min 59 s keys. a a-1 a-2 a-3 b b-1 d e f z s (A) (A-1) (A-2) (A-3) (b) (b-1) (d) (E) (F) (Z) (S) Note: Only modes A-2, b, E, and Z can be selected for models with instantaneous contact outputs. Set each digit for the output time using the corresponding One-shot Output time Set Value 0.01 s to 99.99 s (default setting) hold keys. 0.01 ~ 99.99 (Output hold) (0.01s) 0.1 min to 999.9 min 1 min to 9999 min 0 h 01 min to 99 h 59 min 0.1 h to 999.9 h (99.99s) (If the one-shot output time is set to 0.00, hold is displayed.) 1 h to 9999 h Note: Displayed for modes A, A-1, A-2, A-3, b, b-1 and S only. Input signal width Set the input signal width using the 20ms (20ms) keys. 1ms (1ms) Note: Not displayed for models with instantaneous contact outputs. Instantaneous/ time-limit Set the function (instantaneous or time-limit operation) for the instantaneous output (output 1) using the Keys. 1c1c 2c (Instantaneous) (Time-limit) Note: Displayed only for models with instantaneous contact outputs. From next page To next page 12 0.001 s to 9.999 s H5CZ Timer From previous page To previous page Function setting mode Set value upper limit Key protect level Set the digits for the set value limit using the corresponding 1 9999 (1) (9999) Set the key protect level using the keys. keys. kp-1 kp-2 kp-3 kp-4 kp-5 kp-6 kp-7 (KP-1) (KP-2) (KP-3) (KP-4) (KP-5) (KP-6) (KP-7) *1 Output ON count alarm set value/ monitor value *1. Set each digit for the output time using the corresponding keys. • Models without Instantaneous Contact Outputs Output ON count alarm set value Output ON count monitor value 0 ~ 9999 (0 x 1000 times) (9999 x 1000 times) Note: The monitor value is only displayed. It cannot be set. • Models with Instantaneous Contact Outputs Instantaneous output 1 (OUT1) ON count alarm set value Instantaneous output 2 (OUT2) ON count alarm set value Instantaneous output 1 (OUT1) ON count monitor value Instantaneous output 2 (OUT2) ON count monitor value 0 ~ 9999 (0 x 1000 times) (9999 x 1000 times) 0 ~ 9999 (0 x 1000 times) (9999 x 1000 times) Note: The monitor value is only displayed. It cannot be set. Note: The monitor value is only displayed. It cannot be set. 13 H5CZ Timer Explanation of Functions Operating Procedures for Timer Function Time Range (timr) Set Value Upper Limit (sl-h) Set the range to be timed in the range 0.001 s to 9,999 h. Set the upper limit for the set value when it is set in Run Mode. The limit can be set to between 1 and 9999. This setting does not apply to the ON duty in Z mode. Timer Mode (timm) Set either the elapsed time (UP) or remaining time (DOWN) mode. In UP mode, the elapsed time is displayed, and in DOWN mode, the remaining time is displayed. Output Mode (outm) Set the output mode. The possible settings are A, A-1, A-2, A-3, b, b-1, d, E, F, Z and S. (For details on output mode operation, refer to “Timing Charts” on page 16.) Output Time (otim) When using one-shot output, set the output time for one-shot output (0.01 to 99.99 s). One-shot output can be used only if the selected output mode is A, A-1, A-2, A-3, b, b-1 or S. If the output time is set to 0.00, hold is displayed, and the output is held. Input Signal Width (iflt) Set the minimum signal input width (20 ms or 1 ms) for signal and reset inputs. The same setting is used for all external inputs (signal and reset inputs). If contacts are used for the input signal, set the input signal width to 20 ms. Processing to eliminate chattering is performed for this setting. Key Protect Level (kypt) Set the key protect level. Refer to “Key Protect Level” on page 28. Instantaneous/Time-limit (otmd) Set the contact output to time-limit SPDT + instantaneous SPDT or time-limit SPDT operation. 14 Output ON Count Alarm Set Value (on-a) Set the alarm value for the output ON count. The limit can be set to between 0 x 1000 (0 times) and 9999 x 1000 (9,999,000 times). Only the underlined values are set. The alarm will be disabled if 0 is set. If the total ON count of the output exceeds the alarm set value, e3 will be displayed on the Timer to indicate that the output ON count alarm value was exceeded. Refer to “Self-diagnostic Function” on page 28 for information on the e3 display. ON Count Alarm Set Values for Outputs 1 and 2 (OUT1 and OUT2) (on1a and on2a) Set the ON count alarm values for the outputs 1 and 2. The limit can be set to between 0 x 1000 (0 times) and 9999 x 1000 (9,999,000 times). Only the underlined values are set. The alarm will be disabled if 0 is set. If the total ON count of instantaneous output 1 or 2 exceeds the alarm set value, e3 will be displayed on the Timer to indicate that the output ON count alarm value was exceeded. Refer to “Self-diagnostic Function” on page 28 for information on the e3 display. Output ON Count Monitor Value (on-c) The monitor value is only displayed. It cannot be set. The output ON count will be 1,000 times the displayed value. ON Count Monitor Values for Outputs 1 and 2 (OUT1 and OUT2) (on1c and on2c) The monitor value for output 1 or 2 is only displayed. It cannot be set. The output ON count will be 1,000 times the displayed value. H5CZ Timer Operation in Run Mode Operating Procedures for Timer Function Present value Set each digit for the output time using the corresponding keys. Set value Note: H5CZ-L8E@ Precautions Set the Timer’s set value before using the Timer in a self-holding circuit. When Output Mode Z Is Selected Present value Set each digit for the output time using the corresponding (The keys for the 4th digit cannot be used.) keys. Set each digit for the output time using the corresponding keys. ON duty ratio Present value Cycle time 15 H5CZ Timer Timing Charts Operating Procedures for Timer Function Models without Instantaneous Contact Outputs Either one-shot output or sustained output can be selected. Mode A: Signal ON delay 1 (Timer resets when power comes ON.) Basic operation Detailed operation Power Power * Start signal input Start signal Timing Reset Output t Timing starts when the start signal goes ON. While the start signal is ON, the timer starts when the power comes ON or when the reset input goes OFF. The control output is controlled using a sustained or one-shot time period. Note: Output is instantaneous when setting is 0. t Control output Timing diagram * Start signal input is disabled during timing. Set value UP 0 Set value DOWN 0 Mode A-1: Signal ON delay 2 (Timer resets when power comes ON.) Basic operation Detailed operation Power Power Start signal Start signal input Timing Reset Output t Control output Timing diagram Timing starts when the start signal goes ON, and resets when the start signal goes OFF. While the start signal is ON, the timer starts when the power comes ON or when the reset input goes OFF. The control output is controlled using a sustained or one-shot time period. Note: Output is instantaneous when setting is 0. Set value UP 0 Set value DOWN 0 Mode A-2: Power ON delay 1 (Timer resets when power comes ON.) Basic operation Detailed operation Power Power Timing Start signal Output Reset t Control output Timing diagram Timing starts when the reset input goes OFF. The start signal disables the timing function. The control output is controlled using a sustained or one-shot time period. Note: Output is instantaneous when setting is 0. Set value UP 0 Set value DOWN 0 Mode A-3: Power ON delay 2 (Timer does not reset when power comes ON.) Basic operation Detailed operation Power Power Timing Start signal Sustained Output Reset 16 t Control output Timing diagram Timing starts when the reset input goes OFF. The start signal disables the timing function. The control output is controlled using a sustained or one-shot time period. Note: Output is instantaneous when setting is 0. Set value UP 0 Set value DOWN 0 t t H5CZ Timer Mode b: Repeat cycle 1 (Timer resets when power comes ON.) Basic operation Detailed operation Sustained Output Power Power * Start signal input Timing Timing Timing Timing Start signal Output Reset * Start signal input is disabled during timing. Control output Timing diagram Timing starts when the start signal goes ON. The status of the control output is reversed when time is up (OFF at start). While the start signal is ON, the timer starts when the power comes ON or when the reset input goes OFF. Note: Normal output operation will not be possible if the set time is too short. Set the value to at least 100 ms (contact output type). Set value UP 0 Set value DOWN 0 One-shot Output Power Power * Start signal input Timing Timing Timing Start signal Timing Output Reset * Start signal input is disabled during timing. t t Control output Timing diagram Timing starts when the start signal goes ON. The control output is turned ON when time is up. While the start signal is ON, the timer starts when the power comes ON or when the reset input goes OFF. Note: Normal output operation will not be possible if the set time is too short. Set the value to at least 100 ms (contact output type). Set value UP 0 Set value DOWN 0 Mode b-1: Repeat cycle 2 (Timer does not reset when power comes ON.) Basic operation Detailed operation Sustained Output Power * Start signal input Power TimingTiming Sustained Timing Timing Timing Start signal Output Reset * Start signal input is disabled during timing. Control output Timing diagram Timing starts when the start signal goes ON. The status of the control output is reversed when time is up (OFF at start). While the start signal is ON, the timer starts when the power comes ON or when the reset input goes OFF. Note: Normal output operation will not be possible if the set time is too short. Set the value to at least 100 ms (contact output type). Set value UP 0 Set value DOWN 0 One-shot Output Power Power * Start signal input TimingTiming Sustained Timing Timing Start signal Timing Output Reset * Start signal input is disabled during timing. t t t t Control output Timing diagram Timing starts when the start signal goes ON. The control output is turned ON when time is up. While the start signal is ON, the timer starts when the power comes ON or when the reset input goes OFF. Note: Normal output operation will not be possible if the set time is too short. Set the value to at least 100 ms (contact output type). Set value UP 0 Set value DOWN 0 17 H5CZ Timer Mode d: Signal OFF delay (Timer resets when power comes ON.) Basic operation Detailed operation Power Power Start signal * Start signal input Timing Reset Output * Start signal input is enabled during timing. Timing diagram Control output The control output is ON when the start signal is ON (except when the power is OFF or the reset is ON). The timer resets when the time is up. Note: Output functions only during start signal input when setting is 0. Set value UP 0 Set value DOWN 0 Mode E: Interval (Timer resets when power comes ON.) Basic operation Detailed operation Power Power Start signal * Start signal input Timing Reset Output Timing starts when the start signal comes ON. The timer resets when the time is up. While the start signal is ON, the timer starts when the power comes ON or when the reset input goes OFF. Note: Output is disabled when the setting is 0. Control output Timing diagram * Start signal input is enabled during timing. Set value UP 0 Set value DOWN 0 Mode F: Cumulative (Timer does not reset when power comes ON.) Basic operation Detailed operation Power Power Start signal input Timing Sustained Start signal Timing Output When the H5CZ is used with power start in mode F (i.e., cumulative operation with output on hold), there will be a timer error (approximately 100 ms each time the H5CZ is turned ON) due to the characteristics of the internal circuitry. Use the H5CZ with signal start if timer accuracy is required. Reset Control output Timing diagram Start signal enables timing (timing is stopped when the start signal is OFF or when the power is OFF). A sustained control output is used. Note: Output is instantaneous when setting is 0. Set value UP 0 Set value DOWN 0 Mode Z: ON/OFF-duty-adjustable flicker (Timer resets when power comes ON.) Basic operation Detailed operation Power * Start signal input Power Start signal Timing (cycle time) Timing (cycle time) Timing Timing ON duty (%) ON duty (%) Output Reset Control output Timing starts when the start signal goes ON. The status of the control output is reversed when time is up (ON at start). While the start signal is ON, the timer starts when power comes ON or when the reset input goes OFF. Note: Normal output operation will not be possible if the set time is too short. Set the value to at least 100 ms (contact output type). 18 Timing diagram * Start signal input is disabled during timing. Cycle time UP ON duty setting (%) ON time 0 Cycle time ON duty setting (%) ON time DOWN 0 H5CZ Timer Mode S: Stopwatch (Timer resets when power comes ON.) Basic operation Detailed operation Power Power Start signal Start signal input Timing Reset Reset 9999 Display (for elapsed time) * * RST flashes The signal starts and stops timing. The display is held and timing is continued if the reset is received during timing operation. The timer resets if the reset is received when the timing operation is stopped. Timing diagram Set time UP 0 Set time DOWN 0 Output Note: Output is instantaneous when setting is 0. 19 H5CZ Timer Models with Instantaneous Contact Outputs Either one-shot output or sustained output can be selected. Mode A-2: Power ON delay (Timer resets when power comes ON.) Basic operation Detailed operation t-a t Rt t t-a Rt t-a Power Power Timing Time-limit output Reset Key Instantaneous output Time-limit contacts, NC The Timer starts when the power comes ON or when the reset input goes OFF. Note: Output is instantaneous when setting is 0. Time-limit contacts, NO Instantaneous contacts, NC Instantaneous contacts, NO t = Set time, Rt = Reset time (0.5 s min.), t – a < t (Indicates the time is less than the set time.) Mode b: Repeat cycle 1 (Timer resets when power comes ON.) Basic operation Detailed operation t-a t t t t-a Rt t t t t-a t-a Rt t-a Power t (time) t (time) t (time) t (time) Time-limit output Instantaneous output The Timer starts when the power comes ON or when the reset input goes OFF. Note: Normal output operation will not be possible if the set time is too short. Set the value to at least 100 ms. Power Reset Key Time-limit contacts, NC Sustained Output Time-limit contacts, NO Time-limit contacts, NC One-shot Output Time-limit contacts, NO Instantaneous contacts, NC Instantaneous contacts, NO t = Set time, Rt = Reset time (0.5 s min.), t – a < t (Indicates the time is less than the set time.) Note: H5CZ-L8E@ Precautions Set the Timer’s set value before using the Timer in a self-holding circuit. 20 H5CZ Timer Mode E: Interval (Timer resets when power comes ON.) Basic operation Detailed operation t-a t Rt t t-a Rt t-a Power Power Timing Time-limit output Reset Key Instantaneous output Time-limit contacts, NC The Timer starts when the power comes ON or when the reset input goes OFF. Time-limit contacts, NO Note: Output is not instantaneous when setting is 0. Instantaneous contacts, NC Instantaneous contacts, NO t = Set time, Rt = Reset time (0.5 s min.), t – a < t (Indicates the time is less than the set time.) Mode Z: ON/OFF-duty adjustable flicker (Timer resets when power comes ON.) Basic operation Detailed operation t t-a dty Power Timing (cycle time) Timing (cycle time) Time-limit output Timing Timing (ON duty) (ON duty) Instantaneous output t-a dty t Rt dty t-a t-a Rt t-a dty Power Reset Key Time-limit contacts, NC The Timer starts when the power comes ON or when the reset input goes OFF. Time-limit contacts, NO Note: Normal output operation will not be possible if the set time is too short. Set the value to at least 100 ms. Instantaneous contacts, NC Instantaneous contacts, NO t = Set time, dty = ON duty time, Rt = Reset time (0.5 s min.), t – a < t (Indicates the time is less than the set time.) Note: H5CZ-L8E@ Precautions Set the Timer’s set value before using the Timer in a self-holding circuit. 21 H5CZ Twin Timer Setting Procedure Guide Operating Procedures for Twin Timer Function Step1 Switching to a Twin Timer Power ON Timer/twin timer selection mode 1 + Hold down for 1 s min. Run mode Press the or Key to switch to a Twin Timer. tim twn Timer Twin timer 1 + Hold down for 1 s min. To switch to twin timer operation, use the procedure given below. For details, refer to page 27. Step2 • Change to Function Setting Mode. For details on operations in run mode, refer to page 24. Power ON 3 s min. Run mode *1 Function setting mode 3 s min. *2 *1. If the mode is switched to the function setting mode during operation, operation will continue. *2. Changes made to settings in function setting mode are enabled for the first time when the mode is changed to run mode. Also, when settings are changed, the timer is reset (time initialized and output turned OFF). The characters displayed in reverse video are the default settings. OFF time range Set the OFF time range using the keys. Time Range List …… Display For details, refer to Time Range List. ON time range Set the ON time range using the keys. 0.1 s to 999.9 s Function setting mode …… 1 s to 9999 s For details, refer to Time Range List. Set the timer mode using the 0 min 01 s to 99 min 59 s keys. 0.1 min to 999.9 min Timer mode up (UP) Twin timer output mode down 1 min to 9999 min (DOWN) Set the twin timer output mode using the keys. ton tof1 ton1 Flicker Flicker Flicker ( OFFFlicker start 1) ( On Start 1 ) ( OFF start 2 ) ( On Start 2 ) Note: Only Flicker OFF Start 1 or Flicker ON Start 1 can be selected for the H5CZ-L8E@. Set the input signal width using the 20ms (20 ms) keys. 1ms (1 ms) Note: Not displayed for models with instantaneous contact outputs. To next page From next page 22 0 h 01 min to 99 h 59 min 0.1 h to 999.9 h toff Input signal width Set Value 0.01 s to 99.99 s (default setting) 1 h to 9999 h 0.001 s to 9.999 s H5CZ Twin Timer From previous page To previous page Instantaneous/ time-limit Set the function (instantaneous or time-limit operation) for the instantaneous output (output 1) using the Keys. 1c1c 2c (Instantaneous) (Time-limit) Note: Displayed only for models with instantaneous contact outputs. Function setting mode Set value upper limit 1 Set value upper limit 2 Key protect level Set the digits for the set value limit using the corresponding 1 9999 (1) (9999) Set the digits for the set value limit using the corresponding 1 9999 (1) (9999) Set the key protect level using the keys. keys. keys. kp-1 kp-2 kp-3 kp-4 kp-5 kp-6 kp-7 (KP-1) (KP-2) (KP-3) (KP-4) (KP-5) (KP-6) (KP-7) *1 Output ON count alarm set value/ monitor value *1. Set the digits for the output ON alarm set value using the corresponding keys. • Models without Instantaneous Contact Outputs Output ON count alarm set value Output ON count monitor value 0 ~ 9999 (0 x 1000 times) (9999 x 1000 times) Note: The monitor value is only displayed. It cannot be set. • Models with Instantaneous Contact Outputs Instantaneous output 1 (OUT1) ON count alarm set value Instantaneous output 2 (OUT2) ON count alarm set value 0 ~ 9999 (0 x 1000 times) (9999 x 1000 times) 0 ~ 9999 (0 x 1000 times) (9999 x 1000 times) Instantaneous output 1 (OUT1) ON count monitor value Note: The monitor value is only displayed. It cannot be set. Instantaneous output 2 (OUT2) ON count monitor value Note: The monitor value is only displayed. It cannot be set. 23 H5CZ Twin Timer Explanation of Functions Operating Procedures for Twin Timer Function OFF Time Range (oftr) Input Signal Width (iflt) Set the time range for the OFF time in the range 0.000 s to 9,999 h. Set the minimum signal input width (20 ms or 1 ms) for signal and reset inputs. The same setting is used for all external inputs (signal and reset inputs). If contacts are used for the input signal, set the input signal width to 20 ms. Processing to eliminate chattering is performed for this setting. ON Time Range (ontr) Set the time range for the ON time in the range 0.001 s to 9,999 h. Timer Mode (timm) Set either the elapsed time (UP) or remaining time (DOWN) mode. In UP mode, the elapsed time is displayed, and in DOWN mode, the remaining time is displayed. Twin Timer Output Mode (totm) Set the output mode. Set either flicker OFF start or flicker ON start. (For details on output mode operation, refer to "Timing Charts" on page 25.) Key Protect Level (kypt) Set the key protect level. Refer to “Key Protect Level” on page 28. Operation in Run Mode Operating Procedures for Twin Timer Function Present value Set the digits for the OFF set time using the corresponding keys. OFF set time Present value Set the digits for the OFF set time using the corresponding keys. ON set time Note: 1. The display will automatically show the OFF set time when the OFF time is being timed and the ON set time when the ON time is being timed. Note: 2. H5CZ-L8E@ Precautions Set the Timer’s set value before using the Timer in a self-holding circuit. Present Value and OFF Set Time Present Value and ON Set Time The present value is displayed in the main display and the OFF set time is displayed in the sub-display. Set the OFF time. The present value is displayed in the main display and the ON set time is displayed in the sub-display. Set the ON time. 24 H5CZ Twin Timer Timing Charts Operating Procedures for Timer Function Models without Instantaneous Contact Outputs Mode toff: Flicker OFF start 1 (Timer resets when power comes ON.) Basic operation Detailed operation Power Power * Start signal input Start signal Timing OFF Timing ON Timing OFF Timing ON Reset Output Timing starts when the start signal goes ON. The status of the control output is reversed when time is up (OFF at start). While the start signal is ON, the timer starts when the power comes ON or when the reset input goes OFF. Note: Normal output operation will not be possible if the set time is too short. Set the value to at least 100 ms (contact output type). Timing diagram Control output * Start signal input is disabled during timing. OFF time UP ON time 0 OFF time DOWN ON time 0 Mode ton: Flicker OFF start 1 (Timer resets when power comes ON.) Basic operation Detailed operation Power Power * Start signal input Start signal Timing ON Timing OFF Timing ON Timing OFF Reset Output Timing starts when the start signal goes ON. The status of the control output is reversed when time is up (ON at start). While the start signal is ON, the timer starts when the power comes ON or when the reset input goes OFF. Note: Normal output operation will not be possible if the set time is too short. Set the value to at least 100 ms (contact output type). Timing diagram Control output * Start signal input is disabled during timing. OFF time UP ON time 0 OFF time DOWN ON time 0 Mode toff-1: Flicker OFF start 2 (Timer does not reset when power comes ON.) Basic operation Detailed operation Power Power * Start signal input Start signal Timing OFF Timing ON Timing OFF a b Reset Output (a + b = ON time) Timing starts when the start signal goes ON. The status of the control output is reversed when time is up (OFF at start). While the start signal is ON, the timer starts when the power comes ON or when the reset input goes OFF. Note: Normal output operation will not be possible if the set time is too short. Set the value to at least 100 ms (contact output type). Control output Timing diagram * Start signal input is disabled during timing. OFF time UP ON time 0 OFF time DOWN ON time 0 25 H5CZ Twin Timer Mode ton-1: Flicker ON start 2 (Timer does not reset when power comes ON.) Basic operation Detailed operation Power Power * Start signal input Start signal Timing ON Timing OFF Timing ON a b Reset Output (a + b = OFF time) Timing starts when the start signal goes ON. The status of the control output is reversed when time is up (ON at start). While the start signal is ON, the timer starts when the power comes ON or when the reset input goes OFF. Note: Normal output operation will not be possible if the set time is too short. Set the value to at least 100 ms (contact output type). Control output Timing diagram * Start signal input is disabled during timing. OFF time UP ON time 0 OFF time DOWN ON time 0 Models with Instantaneous Contact Outputs Mode toff: Flicker OFF start 1 (Timer resets when power comes ON.) Basic operation Detailed operation t-a Power Toff time Ton time Toff time Ton time Time-limit output t-off t-on t-off t-b Rt t-off t-on t-off t-b t-a Rt t-a Power Reset Key Time-limit contacts, NC Instantaneous output The Timer starts when the power comes ON or when the reset input goes OFF. Time-limit contacts, NO Note: Normal output operation will not be possible if the set time is too short. Set the ON time and OFF time to at least 100 ms. Instantaneous contacts, NC Instantaneous contacts, NO t-on = ON time, t-off = OFF time, Rt = Reset time (0.1 s min.), t – a < t-off and t – b < t-on (Indicates the time is less than the set time.) Mode ton: Flicker ON start 1 (Timer resets when power comes ON.) Basic operation Detailed operation t-b Power Ton time Toff time Ton time Toff time Time-limit output Instantaneous output t-on t-off t-on t-a Rt t-on t-off t-on t-a t-b Rt Power Reset Key Time-limit contacts, NC The Timer starts when the power comes ON or when the reset input goes OFF. Time-limit contacts, NO Note: Normal output operation will not be possible if the set time is too short. Set the ON time and OFF time to at least 100 ms. Instantaneous contacts, NC Instantaneous contacts, NO t-on = ON time, t-off = OFF time, Rt = Reset time (0.1 s min.), t – a < t-off and t – b < t-on (Indicates the time is less than the set time.) Note: H5CZ-L8E@ Precautions Set the Timer’s set value before using the Timer in a self-holding circuit. 26 t-b H5CZ Timer/Twin Timer Selection Mode (Configuration Selection) Select whether the H5CZ is used as a timer or a twin timer in timer/twin timer selection mode. Power ON Key 1 Key Run mode Caution *2 Timer/Twin Timer Selection Mode + 1 1 s min. To change the mode to timer/twin timer selection mode, 1 key for 1 s min. with the hold down the key held down. The 1 key must be pressed before the key. If the key is pressed first, the mode will not change. *1 Timer/Twin timer selection Select either tim timer operation or twn twin timer operation using the keys. Note: The H5CZ is factory-set for timer operation. *1. When the mode is changed to timer/twin timer selection mode, the present value is reset and output turns OFF. Timing operation is not performed in timer/twin timer selection mode. *2. Setting changes made in timer/twin timer selection mode are enabled when the mode is changed to run mode. If settings are changed, the HC5Z is automatically reset (present value initialized, output turned OFF). 27 H5CZ Key Protect Level When the key-protect switch is set to ON, it is possible to prevent setting errors by prohibiting the use of certain operation keys by specifying the key protect level (KP-1 to KP-7). The key protect indicator is lit while the key-protect switch is set to ON. OFF * (Disabled) ON (Enabled) * Factory-set to OFF Key protect indicator Details Level Meaning Changing mode* Switching display during operation Reset Key Up/down key KP-1 (default setting) Invalid Valid Valid Valid KP-2 Invalid Valid Invalid Valid KP-3 Invalid Valid Valid Invalid KP-4 Invalid Valid Invalid Invalid KP-5 Invalid Invalid Invalid Invalid KP-6 Invalid Invalid Valid Valid KP-7 Invalid Invalid Invalid Valid * Changing mode to Timer/Twin Timer Selection Mode or Function Setting Mode. Self-diagnostic Function The following displays will appear if an error occurs. Main display Sub-display Error Output status Correction method Set value after reset e1 Not lit CPU OFF Either press the reset key or reset the power supply. e2 Not lit Memory error (RAM) OFF Reset the power supply. e2 sum Memory error EEPROM *1 OFF Reset Key Factory setting No change Output ON count alarm set value exceeded No change Reset Key No change e3 *2 No change No change *1. This includes times when the life of the EEPROM has expired. *2. The normal display and e3 will appear alternately. When the Reset Key is pressed, e3 will no longer be displayed even if the alarm set value is exceeded. (Monitoring is possible, however, because the Timer will continue without clearing the output ON count.) 28 H5CZ Safety Precautions for All H5CZ Series (Common) CAUTION Do not allow pieces of metal, wire clippings, or fine metallic shavings or fillings from installation to enter the product. Doing so may occasionally result in electric shock, fire, or malfunction. Minor injury due to explosion may occasionally occur. Do not use the Timer where subject to flammable or explosive gas. Fire may occasionally occur. Tighten the terminal screws to the rated torque. P2CF Socket terminals: 4.4 lb-in (0.5 N m) • Minor injury due to electric shock may occasionally occur. Do not touch any of the terminals while power is being supplied. Be sure to mount the terminal cover after wiring. The life expectancy of the output relay varies considerably according to its usage. Use the output relay within its rated load and electrical life expectancy. If the output relay is used beyond its life expectancy, its contacts may become fused or there may be a risk of fire. Also, be sure that the load current does not exceed the rated load current and when using a heater, be sure to use a thermal switch in the load circuit. Minor electric shock, fire, or malfunction may occasionally occur. Do not disassemble, modify, or repair the Timer or touch internal components. Precautions for Safe Use • The panel surface of the H5CZ is water-resistant (conforming to NEMA4, IP66, UL Type 4X (Indoor Use Only). To protect the internal circuits from water penetration through the space between the H5CZ and operating panel, waterproof packing is included. Attach the Y92F-30 Adapter with sufficient pressure with the reinforcing screws so that water does not penetrate the panel. 0.5 to 1 mm It is recommended that the space between the screw head and the Adapter be 0.5 to 1 mm. • When mounting the Timer to a panel, tighten the two mounting screws alternately, a little at a time, so as to keep them at an equal tightness. If the panel screws are tightened unequally, water may enter the panel. • Store the Timer at the specified temperature. If the Time has been stored at a temperature of less than -10°C, allow the Time to stand at room temperature for at least 3 hours before use. • Mounting the Timer side-by-side may reduce the life expectancies of internal components. • Use the Timer within the specified ranges for the ambient operating temperature and humidity. • Do not use in the following locations: • Locations subject to sudden or extreme changes in temperature. • Locations where high humidity may result in condensation. • Do not use the Timer outside of the rated ranges for vibration, shock, water exposure, and oil exposure. • Do not use this Timer in dusty environments, in locations where corrosive gasses are present, or in locations subject to direct sunlight. • Install the Timer well away from any sources of static electricity, such as pipes transporting molding materials, powders, or liquids. • Internal elements may be destroyed if a voltage outside the rated voltage range is applied. • Be sure that polarity is correct when wiring the terminals. • Separate the Timer from sources of noise, such as devices with input signals from power lines carrying noise, and wiring for I/O signals. • Do not connect more than two crimp terminals to the same terminal. • Up to two wires of the same size and type can be inserted into a single terminals. • Use the specified wires for wiring. Applicable Wires: AWG 18 to AWG 22, solid or twisted, copper. • Install a switch or circuit breaker that allows the operator to immediately turn OFF the power, and label it to clearly indicate its function. • Approximately 14 V is output from the input terminals. Use a sensor that contains a diode. Sensor Diode 0V Input • Use a switch, relay, or other contact so that the rated power supply voltage will be reached within 0.1 seconds. If the power supply voltage is not reached quickly enough, the Timer may malfunction or outputs may be unstable. • Use a switch, relay, or other contact to turn the power supply OFF instantaneously. Outputs may malfunction and memory errors may occur if the power supply voltage is decreased gradually. • When changing the set value during a timing operation, the output will turn ON if the set value is changed as follows because of the use of a constant read-in system: Elapsed time (UP) mode: Present value ≥ Set value Remaining time (DOWN) mode: Elapsed time ≥ Set value (The present value is set to 0.) When in the remaining time mode, the amount the set value is changed is added to or subtracted from the present value. Operation with a set value of 0 will vary with the output mode. Refer to the timing charts on page 16. • Do not use organic solvents (such as paint thinners or benzine), strong alkali, or strong acids. They will damage the external finish. • Confirm that indications are working normally, including the LCD. The indicator LCD, and resin parts may deteriorate more quickly depending on the application environment, preventing normal indications. Periodic inspection and replacement are required. • The waterproof packing may deteriorate, shrink, or harden depending on the application environment. Periodic inspection and replacement are required. 29 H5CZ Precautions for Correct Use • H5CZ models with a 24-VDC/12 to 24-VDC power supply use a transformer-free power supply method in which the power supply terminals are not isolated from the signal input terminals. If a nonisolating DC power supply is used, unwanted current paths may occasionally burn or destroy internal components depending on the wiring. Always check the wiring sufficiently before use. • An inrush current of approx. 10 A will flow for a short time when the power supply is turned ON. If the capacity of the power supply is not sufficient, the Timer may not start. Be sure to use a power supply with sufficient capacity. • Maintain voltage fluctuations in the power supply within the specified operating voltage range. • When turning the power ON and OFF, input signal reception is possible, unstable, or impossible as shown in the diagram below. Power ON supply OFF 200ms 0 to 50 ms Input Impossible Unstable 5ms Possible 0 to 500 ms Unstable Impossible • To allow for the startup time of peripheral devices (sensors, etc.), the Timer starts timing operation between 200 to 250 ms after power is turned ON. For this reason, in operations where timing starts from power ON, the time display will actually start from 249 ms. If the set value is 249 ms or less, the time until output turns ON will be a fixed value between 200 and 250. The present value display will start from 250 ms. (Normal operation is possible for set values of 250 ms or more.) In applications where a set value of 249 ms or less is required, use start timing with signal input. • Inrush current generated by turning ON or OFF the power supply may deteriorate contacts on the power supply circuit. Turn ON or OFF to a device with the rated current of more than 10 A. • Make sure that all settings are appropriate for the application. Unexpected operation resulting in property damage or accidents may occur if the settings are not appropriate. • Do not leave the Timer for long periods at a high temperature with output current in the ON state. Doing so may result in the premature deterioration of internal components (e.g., electrolytic capacitors). • EEPROM is used as backup memory when the power is interrupted. The write life of the EEPROM is 100,000 writes. The EEPROM is written at the following times: • When the power supply is turned OFF • When switching from Timer/Twin Timer Selection Mode or Function Setting Mode to Run Mode • Dispose of the product according to local ordinances as they apply. 30 Conformance to EN/IEC Standards • When conforming to EMC standards, refer to the information provided in this datasheet for cable selection and other conditions. • This is a class A product. In residential areas it may cause radio interference, in which case the user may be required to take adequate measures to reduce interference. • Basic insulation is provided between the power supply and input terminals. (No insulation is provided between the power supply and input terminals for the H5CZ-L8D.) Basic insulation is provided between power supply and output terminals, and between input and output terminals. • When double insulation or reinforced insulation is required, apply double insulation or reinforced insulation as defined in IEC 60664 that is suitable for the maximum operating voltage with clearances or solid insulation. • Connect the input and output terminals to devices that do not have any exposed charged parts. Warranty and Application Considerations Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will be used. Know and observe all prohibitions of use applicable to this product. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Disclaimers PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. Consult with your OMRON representative at any time to confirm actual specifications of purchased product. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. OMRON Corporation Industrial Automation Company Authorized Distributor: Tokyo, JAPAN Contact: www.ia.omron.com Regional Headquarters OMRON EUROPE B.V. Wegalaan 67-69-2132 JD Hoofddorp The Netherlands Tel: (31)2356-81-300/Fax: (31)2356-81-388 OMRON ELECTRONICS LLC One Commerce Drive Schaumburg, IL 60173-5302 U.S.A. Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 OMRON ASIA PACIFIC PTE. LTD. No. 438A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore 119967 Tel: (65) 6835-3011/Fax: (65) 6835-2711 OMRON (CHINA) CO., LTD. Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 200120, China Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 © OMRON Corporation 2009 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. Printed in Japan CSM_6_1_0614 Cat. No. L116-E1-01 0709