omron.com

New Product
Digital Timer
H5CZ
Easy to Use and Easy to Read.
Basic Features
• Character height of 10 mm for better readability.
• Operation is simplified by the Up/Down Keys for each digit on 4-digit.
Safety and Reliability
• Power supply circuit and input circuits are isolated for safety and reliability.
• Set value limit function prevents unexpected operation of output devices
caused by setting mistakes.
• Output counter function helps in managing the service life of the Timer or
the load.
Other Features
• Models with instantaneous contact output.
• Waterproof, dust-proof structure (UL508 Type 4X and IP66).
• Key protection.
Refer to Safety Precautions on page 29.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Features
Basic Features
Set Value Limit
Better Readability
You can set an upper limit for the set value to prevent unexpected
operation of output devices caused by setting mistakes.
Character Height of 10 mm with a Wide Viewing Angle.
Easy to read from the top,
bottom, and sides.
10 mm (actual size)
Worry-free operation is
achieved with the H5CZ
by restricting the time
that can be set.
Clear
Confirmation
Output Counter
The output counter counts the number of times the output turns ON
(alarm display, count monitoring, count in increments of 1,000). This
counter is useful in managing the service life of the Timer or the load.
The Easiest Operation
Operation is simplified by the Up/Down
Keys for each digit on 4-digit.
Other Features
Models with Instantaneous Contact Output
Models with instantaneous contact outputs have been added for use
with self-holding circuits and as auxiliary relays. These models are
also convenient when replacing analog timers.
Safety and Reliability
Isolated Power Supply and Input Circuits *1
Power supply circuit and input circuits are isolated for safety and
reliability.
Previous non-isolated timers had wiring restrictions and could be damaged if
wired incorrectly. The H5CZ removes these worries.
COM terminal
+V
Note: When the Y92S-29 Waterproof Packing is used.
Select from any of seven protection patterns. Use the best one for the
application.
0-V terminal
–V
Worry-free application is possible in locations subject to water.
Key Protection
Output terminal on PLC
or other device
Input terminal
AC power
supply *2
Waterproof, Dust-proof Structure (UL508 Type
4X and IP66)
Forget These
Worries with the
H5CZ
New Modes
Modes, such as a stopwatch mode (Mode S), have been added.
Select any of 15 modes.
Stabilized DC
power supply
*2. The AC power supply ground is on the commercial power supply side.
*1. H5CZ with 100 to 240-VAC specifications.
1
H5CZ
Model Number Structure
Model Number Legend
H5CZ-L @@@
–––
1 2 3
1. External Connections
2. Output type
3. Supply voltage
Symbol
Meaning
Symbol
Meaning
Symbol
Meaning
8
8-pin socket
None
Contact output (time-limit SPDT)
None
100 to 240 VAC 50/60 Hz
E
Contact output (time-limit
SPDT + instantaneous SPDT) *
D
12 to 24 VDC/24 VAC 50/60 Hz
* Can be used as a time-limit DPDT output.
Ordering Information
List of Models
Type
H5CZ
Time specifications
0.001 to 9.999 s
0.01 to 99.99 s
0.1 to 999.9 s
1 to 9999 s
1 s to 99 min 59 s
0.1 to 999.9 min
1 to 9999 min
1 min to 99 h 59 min
0.1 to 999.9 h
1 to 9999 h
Operating modes
External
connections
Timer Mode
A: Signal ON Delay I
A-1: Signal ON Delay II
A-2: Power ON Delay I
A-3: Power ON Delay II
b: Repeat cycle 1
b-1: Repeat cycle 2
d: Signal OFF Delay
E: Interval
F: Cumulative
Z: ON/OFF-duty-adjustable flicker
S: Stopwatch
Twin Timer Mode
toff: Flicker OFF Start 1
ton: Flicker ON Start 1
toff-1: Flicker OFF Start 2
ton-1: Flicker ON Start 2
Timer Mode
A-2: Power ON Delay I
b: Repeat cycle 1
E: Interval
Z: ON/OFF-duty-adjustable flicker
Twin Timer Mode
toff: Flicker OFF Start 1
ton: Flicker ON Start 1
Inputs
Signal, Reset
(NPN inputs)
Outputs
100 to 240 VAC
H5CZ-L8
12 to 24 VDC/
24 VAC
H5CZ-L8D
Contact output
(time-limit SPDT 100 to 240 VAC
+ instantaneous
SPDT)
Models with
instantaneous
12 to 24 VDC/
contact outputs 24 VAC
*
Note: The functions that are provided depend on the model. Check detailed specifications before ordering.
* A time-limit DPDT output can also be used.
2
Models
Contact output
(time-limit
SPDT)
8-pin socket
None
Supply voltage
H5CZ-L8E
H5CZ-L8ED
H5CZ
Accessories (Order Separately)
Soft Cover
Models
Page
Y92A-48F1
9
Hard Cover
Models
Page
Y92A-48
9
Flush Mounting Adapter
Models
Page
Y92F-30
9
Waterproof Packing
Models
Page
Y92S-29
9
Connection Sockets
Models
Type
Remarks
P2CF-08
Front Connecting
Socket
---
P2CF-08-E
Front Connecting
Socket
(Finger-safe Type)
Round crimp terminals cannot be used on Finger-safe
Sockets. Use forked crimp terminals.
Back Connecting Socket
A Y92A-48G Terminal Cover can be used with the
Socket to create a finger-safe construction.
P3G-08
Page
10
Terminal Covers for P3G-08 Back-connecting Sockets
Models
Page
Y92A-48G
10
3
H5CZ
H5CZ Digital Timers
Specifications
Ratings
Item
Ratings
Models
H5CZ-L8@
Power supply
voltage *1
• 100 to 240 VAC 50/60 Hz
• 12 to 24 VDC/24 VAC 50/60 Hz
Operating voltage
fluctuation range
85% to 110% of rated supply voltage (90% to 110% at 12 to 24 VDC)
Power consumption
Approx. 6.2 VA at 100 to 240 VAC, Approx. 5.1 VA/2.4 W at 24 VAC/12 to 24 VDC *2
Mounting method
Flush mounting, Surface mounting, DIN track mounting
External connections
8-pin socket
Degree of protection
IEC IP66, UL508 Type 4X (indoors) for panel surface only and when Y92S-29 Waterproof Packing is used
4 digits
Digits
0.001 s to 9.999 s, 0.01 s to 99.99 s, 0.1 s to 999.9 s, 1 s to 9999 s, 1 s to 99 min 59 s
0.1 m to 999.9 min, 1 min to 9999 min, 1 min to 99 h 59 min, 0.1 h to 999.9 h, 1 h to 9999 h
Time ranges
Timer mode
Inputs
Elapsed time (Up), Remaining time (Down) (selectable)
Input signals
Signal, Reset
(no inputs on models with instantaneous contact outputs)
Input method
No-voltage Input
ON impedance: 1 kΩ max. (Leakage current: 12 mA when 0 Ω)
ON residual voltage: 3 V max.
OFF impedance: 100 kΩ min.
Signal, reset
Minimum input signal width: 1 or 20 ms (selectable, same for all input)
Reset system
Power reset (depending on output mode), External reset, Manual reset, Automatic reset (depending on output mode)
Power reset
Minimum power-opening time: 0.5 s (except for A-3, b-1, F, ton-1, and toff-1 mode)
Reset voltage
10% max. of rated supply voltage
Sensor waiting time
250 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.)
Output modes
A: Signal ON Delay I, A-1: Signal ON Delay II, A-2: Power ON Delay I, A-3: Power
ON Delay II, b: Repeat Cycle 1, b-1: Repeat Cycle 2, d: Signal OFF Delay, E:
Interval, F: Cumulative, Z: ON/OFF-duty-adjustable flicker, S: Stopwatch, toff:
Flicker OFF Start 1, ton: Flicker ON Start 1, toff-1: Flicker OFF Start 2, ton-1:
Flicker ON Start 2
One-shot output time
0.01 to 99.99 s
Control output
5 A at 250 VAC/30 VDC, resistive load (cos =1)
Minimum applied load: 10 mA at 5 VDC (failure level: P, reference value)
Contact materials: AgSnIn
Output
Display method *3
LCD; Present value: 10-mm-high characters
Set value:
6-mm-high characters
Memory backup
EEPROM (overwrites: 100,000 times min.) that can store data for 10 years min.
Operating temperature range
-10 to 55°C (-10 to 50°C if counters are mounted side by side) (with no icing or condensation)
Storage temperature range
-25 to 70°C (with no icing or condensation)
Operating humidity range
25% to 85%
Front panel color
Light gray (5Y7/1)
*1. Do not use the output from an inverter as the power supply. The ripple must be 20% maximum for DC power.
*2. Inrush current will flow for a short time when the power supply is turned ON.
Inrush Current (Reference Values)
Voltage
100 to 240 VAC
12 to 24 VDC/24 VAC
Applied voltage
Inrush current (peak value)
Time
264 VAC
5.3 A
0.4 ms
26.4 VAC
6.4 A
1.4 ms
26.4 VDC
4.4 A
1.7 ms
*3. The display is lit only when the power is ON. Settings and changes are not possible if the power supply is not ON.
4
Models with Instantaneous Contact Outputs
A-2: Power ON Delay I, b: Repeat Cycle 1,
E: Interval, Z: ON/OFF-duty-adjustable
flicker, toff: Flicker OFF Start 1, ton: Flicker
ON Start 1
H5CZ
Characteristics
Power-ON start: ±0.01% ±50 ms max. (See note)
Signal start: ±0.005%±0.03 ms max. (See note)
If the set value is within the sensor waiting time at startup the control
output of the H5CZ will not turn ON until the sensor waiting time passes.
Note: The values are based on the set value.
Insulation resistance
100 MΩ min. (at 500 VDC) between current-carrying terminal and
exposed non-current-carrying metal parts, and between non-continuous
contacts
Dielectric strength
2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and
non-current-carrying metal parts
2,000 VAC, 50/60 Hz for 1 min between power supply and input circuits
for all models except H5CZ-@D
2,000 VAC, 50/60 Hz for 1 min between control output, power supply,
and input circuits
1,000 VAC, 50/60 Hz for 1 min between non-continuous contacts
Impulse withstand voltage
Noise immunity
Static immunity
Malfunction: 8 kV
Destruction: 15 kV
Shock
resistance
Life
expectancy
Destruction
10 to 55 Hz with 0.75-mm single amplitude each in three directions for
2 h each
Malfunction
10 to 55 Hz with 0.35-mm single amplitude each in three directions for
10 min each
Destruction
300 m/s2 in three directions, three cycles
Malfunction
100 m/s2 in three directions, three cycles
Mechanical
10,000,000 operations min. (under no load at 1,800 operations/h and
ambient temperature of 23°C)
Electrical
100,000 operations min. (5 A at 250 VAC, resistive load at 1,800
operations/h and ambient temperature of 23°C) *
Weight
1,000
500
100
DC30V L/R=7ms
50
AC250V/DC30V
cosφ =1
5 kV (between power terminals) for 100 to 240 VAC, 1 kV for 24 VAC/12
to 24 VDC
5 kV (between current-carrying terminal and exposed non-currentcarrying metal parts) for 100 to 240 VAC 1.5 kV for 24 VAC/12 to 24 VDC
±1.5 kV (between power terminals) and ±600 V (between input
terminals), square-wave noise by noise simulator (pulse width: 100 ns/
1 µs, 1-ns rise)
Vibration
resistance
Life-test Curve (Reference
Values)
Switching operations (× 104)
Accuracy of operating time
and setting error (including
temperature and voltage
influences)
10
AC250V cosφ =0.4
0
1
2
3
4
5
Load current (A)
A maximum current of 0.15 A can be switched at
125 VDC (cosφ =1) and a maximum current of 0.1
A can be switched if L/R is 7 ms. In both cases, a
life of 100,000 operations can be expected.
Approx. 105 g (Timer only)
* Refer to Life-test Curve.
Applicable Standards
Approved safety standards
UL508/Listing, UL50 Type 4X for indoor use (enclosure rating), CSA C22.2 No. 14 *,
conforms to EN61812-1 (Pollution degree 2/overvoltage category III)
B300 PILOT DUTY
1/4 HP 120 VAC, 1/3 HP, 240 VAC, 5 A resistive load
VDE0106/P100
CCC: Pollution degree 2, Overvoltage category II
EMC
(EMI)
Emission Enclosure:
Emission AC mains:
(EMS)
Immunity ESD:
Immunity RF-interference:
Immunity Burst:
Immunity Surge:
Immunity Conducted Disturbance:
Immunity Voltage Dip/Interruption:
EN61812-1
EN55011 Group 1 class A
EN55011 Group 1 class A
EN61812-1
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-5
IEC61000-4-6
IEC61000-4-11
* The following safety standards apply to H5CZ.
cUL (Listing): Applicable when an OMRON P2CF (-E) Socket is used.
cUR (Recognition): Applicable when any other socket is used.
I/O Functions
For details, refer to the timing charts on page 16 and page 25.
Start signal
Normally functions to start timing.
In modes A-2 and A-3, disable timing. In mode S, starts and stops timing.
Reset
• Resets present value. (In elapsed time mode, the present value returns to 0; in remaining time mode,
the present value returns to the set value.)
• Count inputs are not accepted and control output turns OFF while reset input is ON.
• Reset indicator is lit while reset input is ON.
Control output (OUT)
Outputs take place according to designated operating mode when timer reaches corresponding set value.
Inputs *
Outputs
* The H5CZ-L8E@ does not have an input.
5
H5CZ
Connections
Block Diagram
(Basic insulation)
Output circuit
Power supply
circuit
(See note.)
(Basic insulation)
Display circuit
Internal control
circuit
Input circuits
Key switch circuit
Note: Basic insulation is provided between the power supply circuit and the input circuits. However, basic insulation is not provided in the
H5CZ-@D.
Terminal Arrangement
Confirm that the power supply meets specifications before use.
H5CZ-L8/-L8D
H5CZ-L8E/-L8ED
Internal circuit
Internal circuit
Internal circuit
Signal
4
Reset
4
5
3
6
2
7
1
Instantaneous
contact output
OUT1
Contact
output
5
3
6
2
7
8
1
8
(–)
(+)
Time-limit
contact output
OUT2
0V
(-)
Terminals 1 and 2 of the H5CZ-L8D
are connected internally.
(+)
OUT1 can also be used as a time-limit
contact output.
Note: Do not connect unused terminals as relay terminals.
Input Circuits
Signal and Reset Input
No-voltage Inputs (NPN Inputs)
+14 V
1 kΩ
Internal
circuit
IN
Input Connections
The inputs are no-voltage (closed or open). (The H5CZ-L8E@ does not have an input.)
No-voltage Inputs (NPN Inputs)
Open Collector
Voltage Output
PLC or
sensor
Contact Input
3
4
1
3
4
Note: Operate with transistor ON
No-voltage Input Signal Levels
No-contact
input
Short-circuit level Transistor ON
• Residual voltage: 3 V max.
• Impedance when ON: 1 kΩ max.
(The leakage current is approx. 12 mA when the
impedance is 0 Ω.)
Open level Transistor OFF
• Impedance when OFF: 100 kΩ min.
Contact input
Use contacts which can adequately switch 5 mA at 10 V
Note: The DC voltage must be 30 VDC max.
1
3
4
Note: Operate with contacts ON.
1
Reset input
3
Signal input
0 V for inputs
Signal input
Reset input
0 V for inputs
Signal input
Reset input
0 V for inputs
Reset input
0 V for inputs
1
Signal input
Sensor
Note: Operate with transistor ON
6
DC Two-wire Sensor
4
Note: Operate with transistor ON
Applicable Two-wire Sensor
• Leakage current: 1.5 mA max.
• Switching capacity: 5 mA min.
• Residual voltage: 3.0 VDC max.
• Operating voltage: 10 VDC
H5CZ
Nomenclature
Operation Key
Display Section
4
1. Key Protect Indicator
2. Control Output Indicator
3. Reset Indicator
4. Present Value Display (Main display)
(Character height: 10 mm)
(Changes modes and setting items)
1
5
2
6
3
8
7
10. Up Keys 1 to 4
10
11
11. Down Keys 1 to 4
5. Time Unit Indicators
(If the time range is 0 min, 0 h, 0.0 h, or 0 h
0 min, these indicators flash to indicate
timing operation.)
9
Front View
6. Set Value Display (Sub-display)
(Character height: 6 mm)
Character Size
for Present
Value Display
10 mm
9. Reset Key
(Resets present value and output)
Switches
12. Key-protect Switch
12
7. Set Value 1, 2 Indicator
8. Mode Key
(Default setting)
OFF
(Disabled)
ON
(Enabled)
Character Size
for Set Value
Display
6 mm
7
H5CZ
Dimensions
(unit: mm)
Digital Timers
Digital Timers
Panel Cutouts
Panel cutouts areas shown below. (according
to DIN43700).
H5CZ-L8@ (Flush Mounting/Surface Mounting Models)
60 min.
48×48
6
45+0.6
0
14.2
63.7
45+0.6
0
15 min.
60 min.
44.8×44.8
Dimensions with Flush Mounting Adapter
H5CZ-L8@ (Adapter and Waterproof Packing Ordered Separately)
Y92S-29 (order separately) Panel Y92F-30 (order separately)
P3G-08 (order
Waterproof Packing
Flush Mounting Adapter
separately)
Back-connecting
Socket
Note: 1. The mounting panel thickness
should be 1 to 5 mm.
2. To allow easier operation, it is
recommended that Adapters be
mounted so that the gap between
sides with hooks is at least 15 mm
(i.e., with the panel cutouts
separated by at least 60 mm).
3. It is possible to horizontally mount
Timers side by side. Attach the
Flush Mounting Adapters so that
the surfaces without hooks are on
the sides of the Timers. (However,
if Timers are mounted side by side,
water resistance will be lost.)
n Units mounted side-by-side
(51)
58
A
A=(48n-2.5)
48
7.5
84.8
Dimensions with Front Connecting Socket
*
92.3
H5CZ
-L8@
90
P2CF-08(-E) (order separately)
Front Connecting Socket
8
* These dimensions vary with the type of DIN track (reference value).
+1
–0
With Y92A-48F1 attached.
A={48n-2.5+(n-1)×4} +1
–0
With Y92A-48 attached.
+1
A = (51n - 5.5) –0
H5CZ
Accessories (Order Separately)
Note:
Depending on the operating environment, the condition of
resin products may deteriorate, and may shrink or become
harder. Therefore, it is recommended that resin products are
replaced regularly.
Soft Cover
Hard Cover
Waterproof Packing
Y92A-48F1
Y92A-48
Y92S-29
Protecting the Timer in Environments Subject to Oil
The H5CZ's panel surface is water-resistive (IP@6, UL Type 4X)
and so even if drops of water penetrate the gaps between the keys,
there will be no adverse effect on internal circuits. If, however, there
is a possibility of oil being present on the operator's hands, use the
Soft Cover. The Soft Cover ensures protection equivalent to IP54
against oil. Do not, however, use the H5CZ in locations where it
would come in direct contact with oil.
Order this Waterproof Packing
separately if it is required.
The Waterproof Packing can be used
to achieve IP66 protection.
The Waterproof Packing will deteriorate, harden, and shrink
depending on the application environment. To ensure maintaining the
IP@6, UL Type 4X waterproof level, periodically replace the
Waterproof Packing. The periodic replacement period will depend on
the application environment. You must confirm the proper
replacement period. Use 1 year or less as a guideline. If the
Waterproof Packing is not replaced periodically, the waterproof level
will not be maintained.
It is not necessary to mount the Waterproof Packing if waterproof
construction is not required.
Flush Mounting Adapter
Y92F-30
Order this Flush Mounting Adapter separately
if it is required.
9
H5CZ
Connection Sockets
Front-connecting Sockets
Model
Terminal arrangement
and internal connections
Dimensions
P2CF-08
Mounting hole
dimensions
20.3 max.
50 max.
Two, 4.5-dia. holes
70 max.
35.4
4
6
7.8
Eight, M3.5 x 7.5 sems screws
3
P2CF-08-E
(Finger Safe Terminal)
5
4
3
Two, M4 or 4.5-dia. holes
4.5
40±0.2
21.5 max.
20.3
50 max.
40±0.2
19
7
8
1
2
(Top View)
Two, 4.5-dia. holes
6
5
4
3
3
P2CF-08-E
70 max.
1.3
35.4
10A250VAC
RESISTIVE
7
8
1
2
4
7.8
Eight, M3.5 x 7.5 set screws
5
4.5
Note: Round crimp terminals cannot be used on Finger-safe Sockets. Use forked crimp terminals.
Back-connecting Sockets
Model
Terminal arrangement
and internal connections
Dimensions
P3G-08
27 dia
3
4
5
6
2
1
8
7
45
4.9
45
17
(Bottom View)
Note: A Y92A-48G Terminal Cover can be used with the Socket to create a finger-safe construction.
Terminal Covers for P3G-08 Back-connecting Sockets
Model
Dimensions
Y92A-48G
Twelve, 6.4 dia
34
Y92A-48G
UP
47.7×47.7
48×48
P C
16.5
24.6 27.6
47.4
Note: The Terminal Cover can be used with a Back-mounting Socket (P3G-08) to create a finger-safe construction.
10
Note: The Socket can
also be mounted
to DIN track.
H5CZ
Optional Products for Track Mounting
Mounting Track
PFP-100N
PFP-50N
7.3±0.15
4.5
27±0.15
35±0.3
15
25
10
25
1,000 (500) *
25
10
15 (5) *
25
1
* The values shown in parentheses are for the PFP-50N.
Mounting Track
PFP-100N2
16
4.5
35±0.3 27
25 10
15
25
1,000
25
End Plate
10
25
29.2
24
1
15
1.5
10
6.2
PFP-M
1.8
M4 x 8 pan
head screw
1
50
35.5 35.3
1.8
11.5
10
1.3
4.8
M4 spring washer
Spacer
PFP-S
16
12
5
34.8
44.3
16.5
Note: Order Spacers in increments of 10.
11
H5CZ
Timer
Operating Procedures
Setting Procedure Guide
Settings for Timer Operation *
Use the following settings.
Settings for Twin Timer Operation *
Refer to page 22.
* At the time of delivery, the H5CZ is set to the Timer configuration. Refer to page 25 for information on switching models.
Operating Procedures for Timer Function
• Change to Function Setting Mode.
Power ON
3 s min.
Run mode
*1
For details on operations in run mode, refer to page 15.
Function setting mode
3 s min.
*2
*1. If the mode is switched to the function setting mode during operation, operation will continue.
*2. Changes made to settings in function setting mode are enabled for the first time when the mode is changed to run mode.
Also, when settings are changed, the timer is reset (time initialized and output turned OFF).
The characters displayed in reverse video are the default settings.
Set the time range using the
keys.
Time range
Time Range List
……
Display
For details, refer to the Time Range List.
Timer mode
Set the timer mode using the
up
keys.
1 s to 9999 s
(DOWN)
Function setting mode
Set the output mode using the
Output modes
0.1 s to 999.9 s
down
(UP)
0 min 01 s to
99 min 59 s
keys.
a
a-1
a-2
a-3
b
b-1
d
e
f
z
s
(A)
(A-1)
(A-2)
(A-3)
(b)
(b-1)
(d)
(E)
(F)
(Z)
(S)
Note: Only modes A-2, b, E, and Z can be selected for models with instantaneous
contact outputs.
Set each digit for the output time using the corresponding
One-shot
Output time
Set Value
0.01 s to 99.99 s
(default setting)
hold
keys.
0.01 ~ 99.99
(Output hold) (0.01s)
0.1 min to
999.9 min
1 min to
9999 min
0 h 01 min to
99 h 59 min
0.1 h to 999.9 h
(99.99s)
(If the one-shot output time is set to 0.00, hold is displayed.)
1 h to 9999 h
Note: Displayed for modes A, A-1, A-2, A-3, b, b-1 and S only.
Input signal
width
Set the input signal width using the
20ms
(20ms)
keys.
1ms
(1ms)
Note: Not displayed for models with instantaneous contact outputs.
Instantaneous/
time-limit
Set the function (instantaneous or time-limit operation) for the instantaneous output (output 1)
using the
Keys.
1c1c
2c
(Instantaneous) (Time-limit)
Note: Displayed only for models with instantaneous contact outputs.
From next page To next page
12
0.001 s to
9.999 s
H5CZ
Timer
From previous
page
To previous
page
Function setting mode
Set value
upper limit
Key protect
level
Set the digits for the set value limit using the corresponding
1
9999
(1)
(9999)
Set the key protect level using the
keys.
keys.
kp-1
kp-2
kp-3
kp-4
kp-5
kp-6
kp-7
(KP-1)
(KP-2)
(KP-3)
(KP-4)
(KP-5)
(KP-6)
(KP-7)
*1
Output ON
count alarm
set value/
monitor value
*1. Set each digit for the output time using the corresponding
keys.
• Models without Instantaneous Contact Outputs
Output ON
count alarm
set value
Output ON
count monitor
value
0
~
9999
(0 x 1000 times) (9999 x 1000 times)
Note: The monitor value is only displayed.
It cannot be set.
• Models with Instantaneous Contact Outputs
Instantaneous
output 1
(OUT1) ON
count alarm
set value
Instantaneous
output 2
(OUT2) ON
count alarm
set value
Instantaneous
output 1
(OUT1) ON
count monitor
value
Instantaneous
output 2
(OUT2) ON
count monitor
value
0
~
9999
(0 x 1000 times) (9999 x 1000 times)
0
~
9999
(0 x 1000 times) (9999 x 1000 times)
Note: The monitor value is only displayed.
It cannot be set.
Note: The monitor value is only displayed.
It cannot be set.
13
H5CZ
Timer
Explanation of Functions
Operating Procedures for Timer Function
Time Range (timr)
Set Value Upper Limit (sl-h)
Set the range to be timed in the range 0.001 s to 9,999 h.
Set the upper limit for the set value when it is set in Run Mode.
The limit can be set to between 1 and 9999.
This setting does not apply to the ON duty in Z mode.
Timer Mode (timm)
Set either the elapsed time (UP) or remaining time (DOWN) mode.
In UP mode, the elapsed time is displayed, and in DOWN mode, the
remaining time is displayed.
Output Mode (outm)
Set the output mode.
The possible settings are A, A-1, A-2, A-3, b, b-1, d, E, F, Z and S.
(For details on output mode operation, refer to “Timing Charts” on
page 16.)
Output Time (otim)
When using one-shot output, set the output time for one-shot output
(0.01 to 99.99 s).
One-shot output can be used only if the selected output mode is A,
A-1, A-2, A-3, b, b-1 or S.
If the output time is set to 0.00, hold is displayed, and the output is
held.
Input Signal Width (iflt)
Set the minimum signal input width (20 ms or 1 ms) for signal and
reset inputs.
The same setting is used for all external inputs (signal and reset
inputs).
If contacts are used for the input signal, set the input signal width to
20 ms.
Processing to eliminate chattering is performed for this setting.
Key Protect Level (kypt)
Set the key protect level.
Refer to “Key Protect Level” on page 28.
Instantaneous/Time-limit (otmd)
Set the contact output to time-limit SPDT + instantaneous SPDT or
time-limit SPDT operation.
14
Output ON Count Alarm Set Value (on-a)
Set the alarm value for the output ON count.
The limit can be set to between 0 x 1000 (0 times) and 9999 x 1000
(9,999,000 times). Only the underlined values are set. The alarm will
be disabled if 0 is set.
If the total ON count of the output exceeds the alarm set value, e3 will
be displayed on the Timer to indicate that the output ON count alarm
value was exceeded. Refer to “Self-diagnostic Function” on page
28 for information on the e3 display.
ON Count Alarm Set Values for Outputs 1 and 2 (OUT1
and OUT2) (on1a and on2a)
Set the ON count alarm values for the outputs 1 and 2.
The limit can be set to between 0 x 1000 (0 times) and 9999 x 1000
(9,999,000 times). Only the underlined values are set. The alarm will
be disabled if 0 is set.
If the total ON count of instantaneous output 1 or 2 exceeds the alarm
set value, e3 will be displayed on the Timer to indicate that the output
ON count alarm value was exceeded. Refer to “Self-diagnostic
Function” on page 28 for information on the e3 display.
Output ON Count Monitor Value (on-c)
The monitor value is only displayed. It cannot be set.
The output ON count will be 1,000 times the displayed value.
ON Count Monitor Values for Outputs 1 and 2 (OUT1 and
OUT2) (on1c and on2c)
The monitor value for output 1 or 2 is only displayed. It cannot be set.
The output ON count will be 1,000 times the displayed value.
H5CZ
Timer
Operation in Run Mode
Operating Procedures for Timer Function
Present value
Set each digit for the output time using the corresponding
keys.
Set value
Note: H5CZ-L8E@ Precautions
Set the Timer’s set value before using the Timer in a self-holding circuit.
When Output Mode Z Is Selected
Present value
Set each digit for the output time using the corresponding
(The
keys for the 4th digit cannot be used.)
keys.
Set each digit for the output time using the corresponding
keys.
ON duty ratio
Present value
Cycle time
15
H5CZ
Timer
Timing Charts
Operating Procedures for Timer Function
Models without Instantaneous Contact Outputs
Either one-shot output or sustained output can be selected.
Mode A: Signal ON delay 1 (Timer resets when power comes ON.)
Basic operation
Detailed operation
Power
Power
*
Start signal
input
Start signal
Timing
Reset
Output
t
Timing starts when the start signal goes ON.
While the start signal is ON, the timer starts when the
power comes ON or when the reset input goes OFF.
The control output is controlled using a sustained or
one-shot time period.
Note: Output is instantaneous when setting is 0.
t
Control output
Timing diagram
* Start signal input is disabled during timing.
Set value
UP
0
Set value
DOWN
0
Mode A-1: Signal ON delay 2 (Timer resets when power comes ON.)
Basic operation
Detailed operation
Power
Power
Start signal
Start signal
input
Timing
Reset
Output
t
Control output
Timing diagram
Timing starts when the start signal goes ON, and
resets when the start signal goes OFF.
While the start signal is ON, the timer starts when the
power comes ON or when the reset input goes OFF.
The control output is controlled using a sustained or
one-shot time period.
Note: Output is instantaneous when setting is 0.
Set value
UP
0
Set value
DOWN
0
Mode A-2: Power ON delay 1 (Timer resets when power comes ON.)
Basic operation
Detailed operation
Power
Power
Timing
Start signal
Output
Reset
t
Control output
Timing diagram
Timing starts when the reset input goes OFF.
The start signal disables the timing function.
The control output is controlled using a sustained or
one-shot time period.
Note: Output is instantaneous when setting is 0.
Set value
UP
0
Set value
DOWN
0
Mode A-3: Power ON delay 2 (Timer does not reset when power comes ON.)
Basic operation
Detailed operation
Power
Power
Timing
Start signal
Sustained
Output
Reset
16
t
Control output
Timing diagram
Timing starts when the reset input goes OFF.
The start signal disables the timing function.
The control output is controlled using a sustained or
one-shot time period.
Note: Output is instantaneous when setting is 0.
Set value
UP
0
Set value
DOWN
0
t
t
H5CZ
Timer
Mode b: Repeat cycle 1 (Timer resets when power comes ON.)
Basic operation
Detailed operation
Sustained Output
Power
Power
*
Start signal
input
Timing
Timing
Timing
Timing
Start signal
Output
Reset
* Start signal input is disabled during timing.
Control output
Timing diagram
Timing starts when the start signal goes ON.
The status of the control output is reversed when time
is up (OFF at start).
While the start signal is ON, the timer starts when the
power comes ON or when the reset input goes OFF.
Note: Normal output operation will not be possible if
the set time is too short.
Set the value to at least 100 ms (contact
output type).
Set value
UP
0
Set value
DOWN
0
One-shot Output
Power
Power
*
Start signal
input
Timing
Timing
Timing
Start signal
Timing
Output
Reset
* Start signal input is disabled during timing.
t
t
Control output
Timing diagram
Timing starts when the start signal goes ON.
The control output is turned ON when time is up.
While the start signal is ON, the timer starts when the
power comes ON or when the reset input goes OFF.
Note: Normal output operation will not be possible if
the set time is too short.
Set the value to at least 100 ms (contact
output type).
Set value
UP
0
Set value
DOWN
0
Mode b-1: Repeat cycle 2 (Timer does not reset when power comes ON.)
Basic operation
Detailed operation
Sustained Output
Power
*
Start signal
input
Power
TimingTiming Sustained Timing Timing
Timing
Start signal
Output
Reset
* Start signal input is disabled during timing.
Control output
Timing diagram
Timing starts when the start signal goes ON.
The status of the control output is reversed when time
is up (OFF at start).
While the start signal is ON, the timer starts when the
power comes ON or when the reset input goes OFF.
Note: Normal output operation will not be possible if
the set time is too short.
Set the value to at least 100 ms (contact
output type).
Set value
UP
0
Set value
DOWN
0
One-shot Output
Power
Power
*
Start signal
input
TimingTiming Sustained Timing Timing
Start signal
Timing
Output
Reset
* Start signal input is disabled during timing.
t
t
t
t
Control output
Timing diagram
Timing starts when the start signal goes ON.
The control output is turned ON when time is up.
While the start signal is ON, the timer starts when the
power comes ON or when the reset input goes OFF.
Note: Normal output operation will not be possible if
the set time is too short.
Set the value to at least 100 ms (contact
output type).
Set value
UP
0
Set value
DOWN
0
17
H5CZ
Timer
Mode d: Signal OFF delay (Timer resets when power comes ON.)
Basic operation
Detailed operation
Power
Power
Start signal
*
Start signal
input
Timing
Reset
Output
* Start signal input is enabled during timing.
Timing diagram
Control output
The control output is ON when the start signal is ON
(except when the power is OFF or the reset is ON).
The timer resets when the time is up.
Note: Output functions only during start signal input
when setting is 0.
Set value
UP
0
Set value
DOWN
0
Mode E: Interval (Timer resets when power comes ON.)
Basic operation
Detailed operation
Power
Power
Start signal
*
Start signal
input
Timing
Reset
Output
Timing starts when the start signal comes ON.
The timer resets when the time is up.
While the start signal is ON, the timer starts when the
power comes ON or when the reset input goes OFF.
Note: Output is disabled when the setting is 0.
Control output
Timing diagram
* Start signal input is enabled during timing.
Set value
UP
0
Set value
DOWN
0
Mode F: Cumulative (Timer does not reset when power comes ON.)
Basic operation
Detailed operation
Power
Power
Start signal
input
Timing
Sustained
Start signal
Timing
Output
When the H5CZ is used with power start in mode F (i.e.,
cumulative operation with output on hold), there will be
a timer error (approximately 100 ms each time the
H5CZ is turned ON) due to the characteristics of the
internal circuitry. Use the H5CZ with signal start if timer
accuracy is required.
Reset
Control output
Timing diagram
Start signal enables timing (timing is stopped when the
start signal is OFF or when the power is OFF).
A sustained control output is used.
Note: Output is instantaneous when setting is 0.
Set value
UP
0
Set value
DOWN
0
Mode Z: ON/OFF-duty-adjustable flicker (Timer resets when power comes ON.)
Basic operation
Detailed operation
Power
*
Start signal
input
Power
Start signal
Timing
(cycle time)
Timing
(cycle time)
Timing
Timing
ON duty
(%)
ON duty
(%)
Output
Reset
Control output
Timing starts when the start signal goes ON.
The status of the control output is reversed when time is
up (ON at start).
While the start signal is ON, the timer starts when power
comes ON or when the reset input goes OFF.
Note: Normal output operation will not be possible if
the set time is too short.
Set the value to at least 100 ms (contact output
type).
18
Timing diagram
* Start signal input is disabled during timing.
Cycle time
UP
ON duty setting
(%) ON time
0
Cycle time
ON duty setting
(%) ON time
DOWN
0
H5CZ
Timer
Mode S: Stopwatch (Timer resets when power comes ON.)
Basic operation
Detailed operation
Power
Power
Start signal
Start signal
input
Timing
Reset
Reset
9999
Display
(for elapsed
time)
*
* RST flashes
The signal starts and stops timing.
The display is held and timing is continued if the reset
is received during timing operation.
The timer resets if the reset is received when the
timing operation is stopped.
Timing diagram
Set time
UP
0
Set time
DOWN
0
Output
Note: Output is instantaneous when setting is 0.
19
H5CZ
Timer
Models with Instantaneous Contact Outputs
Either one-shot output or sustained output can be selected.
Mode A-2: Power ON delay (Timer resets when power comes ON.)
Basic operation
Detailed operation
t-a
t
Rt
t
t-a
Rt
t-a
Power
Power
Timing
Time-limit
output
Reset Key
Instantaneous
output
Time-limit
contacts, NC
The Timer starts when the power comes ON or when
the reset input goes OFF.
Note: Output is instantaneous when setting is 0.
Time-limit
contacts, NO
Instantaneous
contacts, NC
Instantaneous
contacts, NO
t = Set time, Rt = Reset time (0.5 s min.), t – a < t (Indicates the time is less than the set time.)
Mode b: Repeat cycle 1 (Timer resets when power comes ON.)
Basic operation
Detailed operation
t-a
t
t
t
t-a
Rt
t
t
t
t-a
t-a
Rt
t-a
Power
t (time)
t (time)
t (time)
t (time)
Time-limit
output
Instantaneous
output
The Timer starts when the power comes ON or when
the reset input goes OFF.
Note: Normal output operation will not be possible if
the set time is too short.
Set the value to at least 100 ms.
Power
Reset Key
Time-limit
contacts, NC
Sustained Output
Time-limit
contacts, NO
Time-limit
contacts, NC
One-shot Output
Time-limit
contacts, NO
Instantaneous
contacts, NC
Instantaneous
contacts, NO
t = Set time, Rt = Reset time (0.5 s min.), t – a < t (Indicates the time is less than the set time.)
Note: H5CZ-L8E@ Precautions
Set the Timer’s set value before using the Timer in a self-holding circuit.
20
H5CZ
Timer
Mode E: Interval (Timer resets when power comes ON.)
Basic operation
Detailed operation
t-a
t
Rt
t
t-a
Rt
t-a
Power
Power
Timing
Time-limit
output
Reset Key
Instantaneous
output
Time-limit
contacts, NC
The Timer starts when the power comes ON or when
the reset input goes OFF.
Time-limit
contacts, NO
Note: Output is not instantaneous when setting is 0.
Instantaneous
contacts, NC
Instantaneous
contacts, NO
t = Set time, Rt = Reset time (0.5 s min.), t – a < t (Indicates the time is less than the set time.)
Mode Z: ON/OFF-duty adjustable flicker (Timer resets when power comes ON.)
Basic operation
Detailed operation
t
t-a
dty
Power
Timing (cycle time) Timing (cycle time)
Time-limit
output
Timing
Timing
(ON duty)
(ON duty)
Instantaneous
output
t-a
dty
t
Rt
dty
t-a
t-a
Rt
t-a
dty
Power
Reset Key
Time-limit
contacts, NC
The Timer starts when the power comes ON or when
the reset input goes OFF.
Time-limit
contacts, NO
Note: Normal output operation will not be possible if
the set time is too short.
Set the value to at least 100 ms.
Instantaneous
contacts, NC
Instantaneous
contacts, NO
t = Set time, dty = ON duty time, Rt = Reset time (0.5 s min.), t – a < t (Indicates the time is less than the set time.)
Note: H5CZ-L8E@ Precautions
Set the Timer’s set value before using the Timer in a self-holding circuit.
21
H5CZ
Twin Timer
Setting Procedure Guide
Operating Procedures for Twin Timer Function
Step1
Switching to a Twin Timer
Power ON
Timer/twin timer
selection mode
1
+
Hold down for 1 s min.
Run mode
Press the
or
Key to
switch to a Twin Timer.
tim
twn
Timer
Twin timer
1
+
Hold down for 1 s min.
To switch to twin timer operation, use the procedure given below. For details, refer to page 27.
Step2
• Change to Function Setting Mode.
For details on operations in run mode, refer to page 24.
Power ON
3 s min.
Run mode
*1
Function setting mode
3 s min.
*2
*1. If the mode is switched to the function setting mode during operation, operation will continue.
*2. Changes made to settings in function setting mode are enabled for the first time when the mode is changed to run mode.
Also, when settings are changed, the timer is reset (time initialized and output turned OFF).
The characters displayed in reverse video are the default settings.
OFF time
range
Set the OFF time range using the
keys.
Time Range List
……
Display
For details, refer to Time Range List.
ON time
range
Set the ON time range using the
keys.
0.1 s to 999.9 s
Function setting mode
……
1 s to 9999 s
For details, refer to Time Range List.
Set the timer mode using the
0 min 01 s to
99 min 59 s
keys.
0.1 min to
999.9 min
Timer mode
up
(UP)
Twin timer
output mode
down
1 min to
9999 min
(DOWN)
Set the twin timer output mode using the
keys.
ton
tof1
ton1
Flicker
Flicker
Flicker
( OFFFlicker
start 1) ( On Start 1 ) ( OFF start 2 ) ( On Start 2 )
Note: Only Flicker OFF Start 1 or Flicker ON Start 1 can be selected for the H5CZ-L8E@.
Set the input signal width using the
20ms
(20 ms)
keys.
1ms
(1 ms)
Note: Not displayed for models with instantaneous contact outputs.
To next page From next page
22
0 h 01 min to
99 h 59 min
0.1 h to 999.9 h
toff
Input signal
width
Set Value
0.01 s to 99.99 s
(default setting)
1 h to 9999 h
0.001 s to
9.999 s
H5CZ
Twin Timer
From previous
page
To previous
page
Instantaneous/
time-limit
Set the function (instantaneous or time-limit operation) for the instantaneous output (output 1)
using the
Keys.
1c1c
2c
(Instantaneous) (Time-limit)
Note: Displayed only for models with instantaneous contact outputs.
Function setting mode
Set value
upper limit 1
Set value
upper limit 2
Key protect
level
Set the digits for the set value limit using the corresponding
1
9999
(1)
(9999)
Set the digits for the set value limit using the corresponding
1
9999
(1)
(9999)
Set the key protect level using the
keys.
keys.
keys.
kp-1
kp-2
kp-3
kp-4
kp-5
kp-6
kp-7
(KP-1)
(KP-2)
(KP-3)
(KP-4)
(KP-5)
(KP-6)
(KP-7)
*1
Output ON
count alarm
set value/
monitor value
*1. Set the digits for the output ON alarm set value using the corresponding
keys.
• Models without Instantaneous Contact Outputs
Output ON
count alarm
set value
Output ON
count monitor
value
0
~
9999
(0 x 1000 times) (9999 x 1000 times)
Note: The monitor value is only displayed.
It cannot be set.
• Models with Instantaneous Contact Outputs
Instantaneous
output 1
(OUT1) ON
count alarm
set value
Instantaneous
output 2
(OUT2) ON
count alarm
set value
0
~
9999
(0 x 1000 times) (9999 x 1000 times)
0
~
9999
(0 x 1000 times) (9999 x 1000 times)
Instantaneous
output 1
(OUT1) ON
count monitor
value
Note: The monitor value is only displayed.
It cannot be set.
Instantaneous
output 2
(OUT2) ON
count monitor
value
Note: The monitor value is only displayed.
It cannot be set.
23
H5CZ
Twin Timer
Explanation of Functions
Operating Procedures for Twin Timer Function
OFF Time Range (oftr)
Input Signal Width (iflt)
Set the time range for the OFF time in the range 0.000 s to 9,999 h.
Set the minimum signal input width (20 ms or 1 ms) for signal and
reset inputs.
The same setting is used for all external inputs (signal and reset
inputs).
If contacts are used for the input signal, set the input signal width to
20 ms.
Processing to eliminate chattering is performed for this setting.
ON Time Range (ontr)
Set the time range for the ON time in the range 0.001 s to 9,999 h.
Timer Mode (timm)
Set either the elapsed time (UP) or remaining time (DOWN) mode.
In UP mode, the elapsed time is displayed, and in DOWN mode, the
remaining time is displayed.
Twin Timer Output Mode (totm)
Set the output mode.
Set either flicker OFF start or flicker ON start. (For details on output
mode operation, refer to "Timing Charts" on page 25.)
Key Protect Level (kypt)
Set the key protect level.
Refer to “Key Protect Level” on page 28.
Operation in Run Mode
Operating Procedures for Twin Timer Function
Present value Set the digits for the OFF set time using the corresponding
keys.
OFF set time
Present value Set the digits for the OFF set time using the corresponding
keys.
ON set time
Note: 1. The display will automatically show the OFF set time when the OFF time is being timed and the ON set time when the ON time is being timed.
Note: 2. H5CZ-L8E@ Precautions
Set the Timer’s set value before using the Timer in a self-holding circuit.
Present Value and OFF Set Time
Present Value and ON Set Time
The present value is displayed in the main display and the OFF set
time is displayed in the sub-display. Set the OFF time.
The present value is displayed in the main display and the ON set
time is displayed in the sub-display. Set the ON time.
24
H5CZ
Twin Timer
Timing Charts
Operating Procedures for Timer Function
Models without Instantaneous Contact Outputs
Mode toff: Flicker OFF start 1 (Timer resets when power comes ON.)
Basic operation
Detailed operation
Power
Power
*
Start signal
input
Start signal
Timing
OFF
Timing
ON
Timing
OFF
Timing
ON
Reset
Output
Timing starts when the start signal goes ON.
The status of the control output is reversed when time is
up (OFF at start).
While the start signal is ON, the timer starts when the
power comes ON or when the reset input goes OFF.
Note: Normal output operation will not be possible if
the set time is too short.
Set the value to at least 100 ms (contact output
type).
Timing diagram
Control output
* Start signal input is disabled during timing.
OFF time
UP
ON time
0
OFF time
DOWN
ON time
0
Mode ton: Flicker OFF start 1 (Timer resets when power comes ON.)
Basic operation
Detailed operation
Power
Power
*
Start signal
input
Start signal
Timing
ON
Timing
OFF
Timing
ON
Timing
OFF
Reset
Output
Timing starts when the start signal goes ON.
The status of the control output is reversed when time is
up (ON at start).
While the start signal is ON, the timer starts when the
power comes ON or when the reset input goes OFF.
Note: Normal output operation will not be possible if
the set time is too short.
Set the value to at least 100 ms (contact output
type).
Timing diagram
Control output
* Start signal input is disabled during timing.
OFF time
UP
ON time
0
OFF time
DOWN
ON time
0
Mode toff-1: Flicker OFF start 2 (Timer does not reset when power comes ON.)
Basic operation
Detailed operation
Power
Power
*
Start signal
input
Start signal
Timing
OFF
Timing
ON
Timing
OFF
a
b
Reset
Output
(a + b = ON time)
Timing starts when the start signal goes ON.
The status of the control output is reversed when time is
up (OFF at start).
While the start signal is ON, the timer starts when the
power comes ON or when the reset input goes OFF.
Note: Normal output operation will not be possible if
the set time is too short.
Set the value to at least 100 ms (contact output
type).
Control output
Timing diagram
* Start signal input is disabled during timing.
OFF time
UP
ON time
0
OFF time
DOWN
ON time
0
25
H5CZ
Twin Timer
Mode ton-1: Flicker ON start 2 (Timer does not reset when power comes ON.)
Basic operation
Detailed operation
Power
Power
*
Start signal
input
Start signal
Timing
ON
Timing
OFF
Timing
ON
a
b
Reset
Output
(a + b = OFF time)
Timing starts when the start signal goes ON.
The status of the control output is reversed when time is
up (ON at start).
While the start signal is ON, the timer starts when the
power comes ON or when the reset input goes OFF.
Note: Normal output operation will not be possible if
the set time is too short.
Set the value to at least 100 ms (contact output
type).
Control output
Timing diagram
* Start signal input is disabled during timing.
OFF time
UP
ON time
0
OFF time
DOWN
ON time
0
Models with Instantaneous Contact Outputs
Mode toff: Flicker OFF start 1 (Timer resets when power comes ON.)
Basic operation
Detailed operation
t-a
Power
Toff time
Ton time
Toff time
Ton time
Time-limit
output
t-off
t-on
t-off
t-b
Rt
t-off
t-on
t-off
t-b
t-a
Rt
t-a
Power
Reset Key
Time-limit
contacts, NC
Instantaneous
output
The Timer starts when the power comes ON or when
the reset input goes OFF.
Time-limit
contacts, NO
Note: Normal output operation will not be possible if
the set time is too short.
Set the ON time and OFF time to at least 100
ms.
Instantaneous
contacts, NC
Instantaneous
contacts, NO
t-on = ON time, t-off = OFF time, Rt = Reset time (0.1 s min.), t – a < t-off and t – b < t-on
(Indicates the time is less than the set time.)
Mode ton: Flicker ON start 1 (Timer resets when power comes ON.)
Basic operation
Detailed operation
t-b
Power
Ton time
Toff time Ton time Toff time
Time-limit
output
Instantaneous
output
t-on
t-off
t-on
t-a
Rt
t-on
t-off
t-on
t-a
t-b
Rt
Power
Reset Key
Time-limit
contacts, NC
The Timer starts when the power comes ON or when
the reset input goes OFF.
Time-limit
contacts, NO
Note: Normal output operation will not be possible if
the set time is too short.
Set the ON time and OFF time to at least 100
ms.
Instantaneous
contacts, NC
Instantaneous
contacts, NO
t-on = ON time, t-off = OFF time, Rt = Reset time (0.1 s min.), t – a < t-off and t – b < t-on
(Indicates the time is less than the set time.)
Note: H5CZ-L8E@ Precautions
Set the Timer’s set value before using the Timer in a self-holding circuit.
26
t-b
H5CZ
Timer/Twin Timer Selection Mode (Configuration Selection)
Select whether the H5CZ is used as a timer or a twin timer in timer/twin timer selection mode.
Power ON
Key
1 Key
Run mode
Caution
*2
Timer/Twin Timer
Selection Mode
+
1
1 s min.
To change the mode to timer/twin timer selection mode,
1 key for 1 s min. with the
hold down the
key held
down. The
1 key must be pressed before the key. If the
key is pressed first, the mode will not change.
*1
Timer/Twin
timer selection
Select either tim timer operation or twn twin timer operation using the
keys.
Note: The H5CZ is factory-set for timer operation.
*1. When the mode is changed to timer/twin timer selection mode, the present value is reset and output turns OFF.
Timing operation is not performed in timer/twin timer selection mode.
*2. Setting changes made in timer/twin timer selection mode are enabled when the mode is changed to run mode.
If settings are changed, the HC5Z is automatically reset (present value initialized, output turned OFF).
27
H5CZ
Key Protect Level
When the key-protect switch is set to ON, it is possible to prevent setting errors by prohibiting the use of certain operation keys by specifying the
key protect level (KP-1 to KP-7).
The key protect indicator is lit while the key-protect switch is set to ON.
OFF *
(Disabled)
ON
(Enabled)
* Factory-set to OFF
Key protect indicator
Details
Level
Meaning
Changing mode*
Switching display
during operation
Reset Key
Up/down key
KP-1
(default setting)
Invalid
Valid
Valid
Valid
KP-2
Invalid
Valid
Invalid
Valid
KP-3
Invalid
Valid
Valid
Invalid
KP-4
Invalid
Valid
Invalid
Invalid
KP-5
Invalid
Invalid
Invalid
Invalid
KP-6
Invalid
Invalid
Valid
Valid
KP-7
Invalid
Invalid
Invalid
Valid
* Changing mode to Timer/Twin Timer Selection Mode or Function Setting Mode.
Self-diagnostic Function
The following displays will appear if an error occurs.
Main display
Sub-display
Error
Output status
Correction method
Set value after reset
e1
Not lit
CPU
OFF
Either press the reset key or
reset the power supply.
e2
Not lit
Memory error (RAM)
OFF
Reset the power supply.
e2
sum
Memory error EEPROM *1
OFF
Reset Key
Factory setting
No change
Output ON count alarm set
value exceeded
No change
Reset Key
No change
e3 *2
No change
No change
*1. This includes times when the life of the EEPROM has expired.
*2. The normal display and e3 will appear alternately.
When the Reset Key is pressed, e3 will no longer be displayed even if the alarm set value is exceeded. (Monitoring is possible, however, because the Timer will
continue without clearing the output ON count.)
28
H5CZ
Safety Precautions for All H5CZ Series (Common)
CAUTION
Do not allow pieces of metal, wire clippings, or fine
metallic shavings or fillings from installation to enter
the product. Doing so may occasionally result in
electric shock, fire, or malfunction.
Minor injury due to explosion may occasionally occur.
Do not use the Timer where subject to flammable or
explosive gas.
Fire may occasionally occur. Tighten the terminal
screws to the rated torque.
P2CF Socket terminals: 4.4 lb-in (0.5 N m)
•
Minor injury due to electric shock may occasionally
occur. Do not touch any of the terminals while power
is being supplied. Be sure to mount the terminal cover
after wiring.
The life expectancy of the output relay varies
considerably according to its usage. Use the output
relay within its rated load and electrical life
expectancy. If the output relay is used beyond its life
expectancy, its contacts may become fused or there may be a
risk of fire. Also, be sure that the load current does not exceed
the rated load current and when using a heater, be sure to use a
thermal switch in the load circuit.
Minor electric shock, fire, or malfunction may
occasionally occur. Do not disassemble, modify, or
repair the Timer or touch internal components.
Precautions for Safe Use
• The panel surface of the H5CZ is water-resistant (conforming to
NEMA4, IP66, UL Type 4X (Indoor Use Only). To protect the
internal circuits from water penetration through the space between
the H5CZ and operating panel, waterproof packing is included.
Attach the Y92F-30 Adapter with sufficient pressure with the
reinforcing screws so that water does not penetrate the panel.
0.5 to 1 mm
It is recommended that the
space between the screw
head and the Adapter be 0.5
to 1 mm.
• When mounting the Timer to a panel, tighten the two mounting
screws alternately, a little at a time, so as to keep them at an equal
tightness. If the panel screws are tightened unequally, water may
enter the panel.
• Store the Timer at the specified temperature. If the Time has been
stored at a temperature of less than -10°C, allow the Time to stand
at room temperature for at least 3 hours before use.
• Mounting the Timer side-by-side may reduce the life expectancies
of internal components.
• Use the Timer within the specified ranges for the ambient operating
temperature and humidity.
• Do not use in the following locations:
• Locations subject to sudden or extreme changes in
temperature.
• Locations where high humidity may result in condensation.
• Do not use the Timer outside of the rated ranges for vibration,
shock, water exposure, and oil exposure.
• Do not use this Timer in dusty environments, in locations where
corrosive gasses are present, or in locations subject to direct
sunlight.
• Install the Timer well away from any sources of static electricity,
such as pipes transporting molding materials, powders, or liquids.
• Internal elements may be destroyed if a voltage outside the rated
voltage range is applied.
• Be sure that polarity is correct when wiring the terminals.
• Separate the Timer from sources of noise, such as devices with
input signals from power lines carrying noise, and wiring for I/O
signals.
• Do not connect more than two crimp terminals to the same
terminal.
• Up to two wires of the same size and type can be inserted into a
single terminals.
• Use the specified wires for wiring. Applicable Wires: AWG 18 to
AWG 22, solid or twisted, copper.
• Install a switch or circuit breaker that allows the operator to
immediately turn OFF the power, and label it to clearly indicate its
function.
• Approximately 14 V is output from the input terminals. Use a
sensor that contains a diode.
Sensor
Diode
0V
Input
• Use a switch, relay, or other contact so that the rated power supply
voltage will be reached within 0.1 seconds. If the power supply
voltage is not reached quickly enough, the Timer may malfunction
or outputs may be unstable.
• Use a switch, relay, or other contact to turn the power supply OFF
instantaneously. Outputs may malfunction and memory errors may
occur if the power supply voltage is decreased gradually.
• When changing the set value during a timing operation, the output
will turn ON if the set value is changed as follows because of the
use of a constant read-in system:
Elapsed time (UP) mode: Present value ≥ Set value
Remaining time (DOWN) mode: Elapsed time ≥ Set value (The
present value is set to 0.)
When in the remaining time mode, the amount the set value is
changed is added to or subtracted from the present value.
Operation with a set value of 0 will vary with the output mode. Refer
to the timing charts on page 16.
• Do not use organic solvents (such as paint thinners or benzine),
strong alkali, or strong acids. They will damage the external finish.
• Confirm that indications are working normally, including the LCD.
The indicator LCD, and resin parts may deteriorate more quickly
depending on the application environment, preventing normal
indications. Periodic inspection and replacement are required.
• The waterproof packing may deteriorate, shrink, or harden
depending on the application environment. Periodic inspection and
replacement are required.
29
H5CZ
Precautions for Correct Use
• H5CZ models with a 24-VDC/12 to 24-VDC power supply use a
transformer-free power supply method in which the power supply
terminals are not isolated from the signal input terminals. If a nonisolating DC power supply is used, unwanted current paths may
occasionally burn or destroy internal components depending on
the wiring. Always check the wiring sufficiently before use.
• An inrush current of approx. 10 A will flow for a short time when the
power supply is turned ON. If the capacity of the power supply is
not sufficient, the Timer may not start. Be sure to use a power
supply with sufficient capacity.
• Maintain voltage fluctuations in the power supply within the
specified operating voltage range.
• When turning the power ON and OFF, input signal reception is
possible, unstable, or impossible as shown in the diagram below.
Power ON
supply OFF
200ms 0 to 50 ms
Input
Impossible
Unstable
5ms
Possible
0 to 500 ms
Unstable Impossible
• To allow for the startup time of peripheral devices (sensors, etc.),
the Timer starts timing operation between 200 to 250 ms after
power is turned ON. For this reason, in operations where timing
starts from power ON, the time display will actually start from 249
ms. If the set value is 249 ms or less, the time until output turns ON
will be a fixed value between 200 and 250. The present value
display will start from 250 ms. (Normal operation is possible for set
values of 250 ms or more.) In applications where a set value of 249
ms or less is required, use start timing with signal input.
• Inrush current generated by turning ON or OFF the power supply
may deteriorate contacts on the power supply circuit. Turn ON or
OFF to a device with the rated current of more than 10 A.
• Make sure that all settings are appropriate for the application.
Unexpected operation resulting in property damage or accidents
may occur if the settings are not appropriate.
• Do not leave the Timer for long periods at a high temperature with
output current in the ON state. Doing so may result in the
premature deterioration of internal components (e.g., electrolytic
capacitors).
• EEPROM is used as backup memory when the power is
interrupted. The write life of the EEPROM is 100,000 writes.
The EEPROM is written at the following times:
• When the power supply is turned OFF
• When switching from Timer/Twin Timer Selection Mode or
Function Setting Mode to Run Mode
• Dispose of the product according to local ordinances as they apply.
30
Conformance to EN/IEC Standards
• When conforming to EMC standards, refer to the information
provided in this datasheet for cable selection and other conditions.
• This is a class A product. In residential areas it may cause radio
interference, in which case the user may be required to take
adequate measures to reduce interference.
• Basic insulation is provided between the power supply and input
terminals. (No insulation is provided between the power supply and
input terminals for the H5CZ-L8D.)
Basic insulation is provided between power supply and output
terminals, and between input and output terminals.
• When double insulation or reinforced insulation is required, apply
double insulation or reinforced insulation as defined in IEC 60664
that is suitable for the maximum operating voltage with clearances
or solid insulation.
• Connect the input and output terminals to devices that do not have
any exposed charged parts.
Warranty and Application Considerations
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or
other period if specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT,
MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER
ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET
THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR
IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS,
OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON
CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE
PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED,
INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE
MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of
products in the customer's application or use of the products.
Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will
be used.
Know and observe all prohibitions of use applicable to this product.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT
ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON
PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR
SYSTEM.
Disclaimers
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a
warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application
requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability.
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons. Consult with
your OMRON representative at any time to confirm actual specifications of purchased product.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON Corporation
Industrial Automation Company
Authorized Distributor:
Tokyo, JAPAN
Contact: www.ia.omron.com
Regional Headquarters
OMRON EUROPE B.V.
Wegalaan 67-69-2132 JD Hoofddorp
The Netherlands
Tel: (31)2356-81-300/Fax: (31)2356-81-388
OMRON ELECTRONICS LLC
One Commerce Drive Schaumburg,
IL 60173-5302 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
© OMRON Corporation 2009 All Rights Reserved.
In the interest of product improvement,
specifications are subject to change without notice.
Printed in Japan