OMRON Y92S-29-ND

Digital Timer
H5CL
Easy-to-see and Easy-to-operate
DIN 48 x 48 mm Digital Timer with
IP66/NEMA 4 Protection
Water- and dust-protected for severe environments.
Large, high-visibility LED displays with a height of
12 mm.
Simple setting with Increment and Decrement
Keys.
Conforms to EMC standards.
Six-language instruction manual provided.
RC
Ordering Information
Outputs
Supply voltage
Model
Without Finger Safe Terminal Cover
Contact output
Transistor
a s s o ou
output
u
(Ph t
(Photocoupler)
l )
With Finger Safe Terminal Cover
100 to 240 VAC
H5CL-A
---
12 to 24 VDC
H5CL-AD
H5CL-AD-500
100 to 240 VAC
H5CL-AS
---
12 to 24 VDC
H5CL-ADS
---
Model Number Legend:
H5CL-A
1 2
3
1. Fixed
2. D: DC Supply Voltage
3. S: Transistor output
Accessories (Order Separately)
Name
Model
Hard cover
Y92A-48
Soft cover
Y92A-48F1
Track
ac Mounting/Front
ou
g/ o Connecting
Co ec g Socket
Soc e (for
( o AC
C
models
d l only)
l )
---
P2CF-11
Finger safe type
P2CF-11-E
Back
ac Connecting
Co ec g Socket
Soc e (for
( o AC
C models
ode s only)
o y)
---
P3GA-11
Finger safe type
P3GA-11 with Y92A-48G (see note 1)
Finger Safe Terminal Cover for DC models
Y92A-48T
Flush Mounting Adapter (see note 2)
Y92F-30
Note:
1. Y92A-48G is a finger safe terminal cover which is attached to the P3GA-11 Socket.
2. Supplied with each Unit.
1
H5CL
H5CL
Specifications
Item
H5CL-Aj (AC models)
H5CL-ADj (DC models)
Classification
Digital timer
Mounting
DIN track, surface, and flush mounting
(common)
Flush mounting
External connections
Socket
Screw terminals
Enclosure ratings
Panel surface: IEC IP66 and NEMA Type 4 (indoors) when Y92S-29 rubber packing is used.
Digits
4 digits (zero suppress method)
Max. time settings
9.999 s (0.001-s unit), 99.99 s (0.01-s unit), 999.9 s (0.1-s unit), 9999 s (1-s unit),
99 min 59 s (1-s unit), 999.9 min (0.1-min unit), 99 h 59 min (1-min unit), 999.9 h (0.1-h unit)
Display modes
Up (increment) and Down (decrement) (selectable)
Input signals
Start, gate, reset, and key protection
Input method
No-voltage input: via NPN transistor or switching of contact
Operating modes
A (signal ON-delay), F (accumulative operation) (selectable)
Reset system
Power reset (A (signal ON-delay) mode only), external, manual resets
Sensor waiting time
216 ms typ., 250 ms max. (Control output is turned OFF and no input is accepted during
sensor waiting time.)
External power supply
50 mA at 12 VDC (±10%)
Display
7-segment LEDs (12 mm high, red LEDs for the present value, and 8 mm high, green LEDs for
the set value)
Memory backup
EEP-ROM (overwritten 200,000 times min.), which can store data for 20 years min.
Mounting method
DIN track mounting, surface mounting, and
flush mounting
Approved standards
UL 508, CSA C22.2 No.14
Conforms to EN61010-1
---
Flush mounting
Ratings
Item
H5CL-Aj (AC models)
H5CL-ADj (DC models)
Rated supply voltage
100 to 240 VAC, 50/60 Hz
12 to 24 VDC (permissible ripple: 20% (p-p) max.)
Operating voltage range
85 to 264 VAC, 50/60 Hz
10.8 to 26.4 VDC
Power consumption
Approx. 10 VA
Approx. 3 W
Start, reset, gate inputs
Min. pulse width: 1 ms/20 ms (selectable, same for all three inputs)
Key protection input
Response time: 1 s max.
Power reset
Min. power opening time: 0.5 s (excluding F (accumulative operation) mode)
Control output
Contact output:
2
SPDT, 3 A at 250 VAC, resistive load (cosφ =1)
Min. applicable load: 10 mA at 5/24 VDC (P level, for reference value)
Transistor output: NPN open collector, 100 mA max. at 30 VDC max.,
residual voltage 1.5 VDC max.
H5CL
H5CL
Characteristics
Item
H5CL-Aj (AC models)
H5CL-ADj (DC models)
Deviation of operating time and
setting error (including temperature
and voltage influences)
Power start: ±0.01% ±0.05 s max. (see note 1)
Signal start: ±0.005% ±0.03 s max. (see note 1)
Signal start, at transistor output model: ±0.005% ±3 ms max. (see note 1 and 2)
If the set value is within the sensor waiting time (250 ms max.) in the case of power start, the
control output of the H5CL will not be turned ON until the sensor waiting time passes.
Insulation resistance
100 MΩ min. (at 500 VDC) (between current-carrying terminal and exposed
non-current-carrying metal parts, and between non-continuous contacts)
Dielectric strength
2,000 VAC, 50/60 Hz for 1 min (between
current-carrying terminal and exposed
non-current-carrying metal parts)
1,000 VAC, 50/60 Hz for 1 min (between
non-continuous contacts)
1,000 VAC, 50/60 Hz for 1 min (between
current-carrying terminal and exposed
non-current-carrying metal parts, and
between non-continuous contacts)
Impulse withstand voltage
3.0 kV (between power terminals)
4.5 kV (between current-carrying terminal and
exposed non-current-carrying metal parts)
1.0 kV (between power terminals)
1.5 kV (between current-carrying terminal and
exposed non-current-carrying metal parts)
Noise immunity
±1.5 kV (between power terminals)
±600 V (between input terminals),
square-wave noise by noise simulator (pulse
width: 100 ns/1 µs, 1-ns rise)
±480 kV (between power terminals)
±600 V (between input terminals),
square-wave noise by noise simulator (pulse
width: 100 ns/1 µs, 1-ns rise)
Static immunity
Destruction:
Malfunction:
15 kV
8 kV
Vibration resistance
Destruction:
Malfunction:
10 to 55 Hz, 0.75-mm single amplitude each in three directions
10 to 55 Hz, 0.5-mm single amplitude each in three directions
Shock resistance
Destruction:
Malfunction:
294 m/s2 (30G) each in three directions
98 m/s2 (10G) each in three directions
Ambient temperature
Operating:
Storage:
Ambient humidity
Operating: 35% to 85%
Life expectancy
Mechanical:
Electrical:
EMC
(EMI):
Emission Enclosure:
Emission AC Mains:
(EMS):
Immunity ESD:
Case color
Light gray (Munsell 5Y7/1)
Weight
Approx. 130 g
Note:
–10 to 55 °C (–10 to 50 °C if timers are mounted side by side) (with no icing)
–25 to 65 °C (with no icing)
10,000,000 operations min.
100,000 operations min. (3 A at 250 VAC, resistive load)
EN50081-2
EN55011 Group 1 class A
EN55011 Group 1 class A
EN50082-2
EN61000-4-2:4 kV contact discharge (level 2)
8 kV air discharge (level 3)
Immunity RF-interference:
ENV50140: 10 V/m (80 MHz to 1 GHz) (level 3)
Immunity Conducted Disturbance: ENV50141: 10 V (0.15 to 80 MHz) (level 3)
Immunity Burst:
EN61000-4-4:2 kV power-line (level 3)
2 kV I/O signal-line (level 4)
Approx. 110 g
1. The values are based on the set value.
2. The value is applied for a minimum pulse width of 1 ms.
3
H5CL
H5CL
Nomenclature
Indicator
Stick the enclosed label here.
1. Present Value
Red LEDs with a character height of 12 mm
Note: The decimal point will flash on the present value during the timing operation in the following ranges:
0.1 to 999.9 min, 0 h 01 min to 99 h 59 min, and
0.1 to 999.9 h.
2. Preset Value
Green LEDs with a character height of 8 mm
3. Reset Indicator (orange)
4. Key Protection Indicator (orange)
5. Time Unit Display (orange)
6. Control Output Indicator (orange)
1
6
2
3
5
7
8
9
Operation Key
7. Reset (RST) Key
The RST Key initializes the present value and control output.
8. Increment Keys (1 to 4)
Up Keys 1 to 4 increment the preset value.
9. Decrement Keys (1 to 4)
Down Keys 1 to 4 decrement the preset value.
4
Operation
DIP Switch Setting
Pin no.
1, 2, 3
Item
OFF
ON
Time ranges
See table below.
4
Display modes
Up (Increment)
Down (Decrement)
5
Min. pulse width of inputs
20 ms
1 ms
6
Operating modes
A (signal ON-delay)
F (accumulative operation)
Note:
Set the DIP switch before installation and operation of the Unit. DIP switch setting changes are not effective while the power is on.
Time Ranges
1
2
3
Time range
ON
ON
ON
0.001 to 9.999 s
OFF
OFF
OFF
0.01 to 99.99 s
ON
OFF
OFF
0.1 to 999.9 s
OFF
ON
OFF
1 to 9999 s
ON
ON
OFF
0 min 01 s to 99 min 59 s
OFF
OFF
ON
0.1 to 999.9 min
ON
OFF
ON
0 h 01 min to 99 h 59 min
ON
ON
0.1 to 999.9 h
OFF
Note:
Switches 1 to 6 are all set to OFF before shipping.
(The same switch settings apply to AC and DC models)
Timer Control with Power Start
When using the H5CL with power start, short-circuit the start input and input 0-V terminals.
4
H5CL
H5CL
Operating Modes
A Mode
Signal ON-delay
Power
Start
Gate
Reset
Display
mode
Control output
Set value
0
Set value
DOWN
0
UP
F Mode
Accumulative Operation
Power
Start
Gate
Reset
Display
mode
Control output
Set value
0
Set value
DOWN
0
UP
Dimensions
Note:
All units are in millimeters unless otherwise indicated.
H5CL-Aj
DIN Track/Surface/Flush Mounting
48
6
72.5
14.4
44.8 x 44.8
48
H5CL-ADj
Flush Mounting
(70)
48
48
6
64
44.8 x 44.8
5
H5CL
H5CL
H5CL-Aj
With Flush Mounting Adapter
Panel
Y92S-29 rubber packing
(provided)
Y92F-30 flush mounting
adapter (provided)
P3GA-11 back connecting
socket (sold separately)
Panel Cutouts
(51)
58
Panel cutouts are as shown below.
(according to DIN43700).
60 min.
48
7.5
98.7
45
+0.6
–0
H5CL-ADj
45
With Flush Mounting Adapter
Panel
Y92S-29 rubber packing
(provided)
Y92F-30 flush mounting
adapter (provided)
60 min.
44.8 x 44.8
(51)
58
+0.6
–0
48
7.5
62.5
n side by side mounting
A
A = (48n–2.5)
Note:
1. The mounting panel thickness should be 1 to 4 mm.
2. It is possible to mount timers side by side, but only in one direction.
3. When the Timers are mounted closely side by side, the Timers will
not be water-resistive.
DIN Track Mounting
H5CL-Aj
120
P2CF-11
H5CL-ADj-500
The cover conforms to finger protection standard against electric shock. (VDE 0106/P100)
47.5
58
64.5
48
7.5
6
+1
–0
H5CL
H5CL
Accessories (Order Separately)
Track Mounting/
Front Connecting Socket
P2CF-11
Eleven,
3
M3.5 x 7.5 sems
4.5
7.8
70 max.
35.4
Two, 4.5 dia.
holes
Terminal Arrangement/
Internal Connections
(Top View)
Surface Mounting Holes
Two, 4.5 dia. mounting holes
4
50 max.
31.2 max.
40±0.2
P2CF-11-E (Finger Safe Terminal Type)
Conforming to VDE0106/P100
Eleven,
M3.5 x 7.5 sems
5
7.8
4.5
3
1.2
70 max.
35.4
Two, 4.5 dia.
holes
4
40±0.2
50 max.
30
31.2 max.
Back Connecting Socket
P3GA-11
Terminal Arrangement/
Internal Connections
(Bottom View)
27 dia.
45
25.6
45
4.5
6.2
16.3
7
H5CL
H5CL
Finger Safe Terminal Cover
Conforming to VDE0106/P100
Twelve, 6.4 dia. holes
Y92A-48G
(Attachment for P3GA-11 Socket)
34
47.7 x 47.7
16.5
Y92A-48T
48 x 48
24.6 27.6
47.4
(Attachment for H5CL DC models)
Hard Cover
Y92A-48
Soft Cover
Y92A-48F1
Installation
Terminal Arrangement
AC Models
Reset
Start
Contact output
Gate
6
5
Key protection
4
9
2
10
1
External power supply
12 VDC (50 mA max.)
8
9
8
3
Input common (0 V)
(+)
Load
(Sensor)
(–)
Transistor output
7
11
11
100 to 240 VAC
Note:
DC Models
Reset
0V
Start
Gate
6
7
1
2
–
+
Power supply circuit is insulated from the internal
circuit (or I/O).
Key protection
8
9
10
3
4
5
Transistor output
3
4
5
Contact output
12 to 24 VDC
Note:
8
1 and 6 are connected to each other internally.
H5CL
H5CL
Input Circuits
Start, Reset, and Gate Input
Key Protection Input
H5CL-ADj (DC Models)
H5CL-Aj (AC Models)
Vin – 3.5V
(16V max.)
+12 V
1 kΩ
+5 V
4.7 kΩ
1 kΩ
IN
IN
Internal circuit
IN
Internal circuit
Vin: Supply voltage
Internal circuit
Note:
No key input is effective while
key protection input is ON.
Input Connections
Open Collector Output
Voltage Output
Contact input
PC or sensor
PC or sensor
0V
12 VDC
6
7
1
AC models
3
5
6
7
1
AC models
3
5
6
7
8
9
7
–
DC models
6
8
9
7
–
DC models
6
8
9
7
Start input
Reset input
12 VDC output
Start input
Reset input
12 VDC output
Gate input
5
6
0V
3
DC models
Gate input
AC models
Start input
Output
Reset input
12 VDC
Gate input
Output
0V
0V
Start, Reset, and Gate Input Specification
ON impedance:
500 Ω max. (the leakage current is 5 to 20 mA when the impedance is 0 Ω.)
ON residual voltage:
2 V max.
OFF impedance:
100 kΩ min.
Maximum applicable voltage: 30 VDC max.
Key Protection Input
Two-wire Sensor
Sensor
Open collector
or
contact
5
6
7
DC models
6
8
9
7
Gate input
Start input
Reset input
Applicable Two-wire Sensor
Leakage current:
1.5 mA max.
Switching capacity: 5 mA min.
Residual voltage: 3 V max.
Operating voltage: 10 VDC
Note: When connecting a two-wire sensor to a DC models, supply 24 VDC (21.6 to 26.4 VDC) to the timer.
AC models
3
4
DC models
6
10
Key protection
input
3
0V
AC models
0V
0V
Key Protection Input
ON impedance:
1 kΩ max.
(the leakage current is approx. 1 mA when the impedance is 0 Ω.)
ON residual voltage:
0.5 V max.
100 kΩ min.
OFF impedance:
Maximum applicable voltage: 30 VDC max.
Note: The used contact should switch 1 mA at 5 V.
9
H5CL
H5CL
Precautions
Power Supplies
When turning the power ON and OFF, input signal reception is possible, unstable, or impossible as shown in the diagram below.
Power
supply
ON
OFF
Input
160 ms 0 to 90ms
0 to 500 ms
DC: 5 ms
AC: 10 ms
Impossible
Possible
Unstable Impossible
Unstable
Apply the power supply voltage through a relay or switch in such a
way that the voltage reaches a fixed value immediately.
Turn the power ON and OFF with relay with a rated capacity of 10 A
minimum to prevent contact deterioration due to inrush current
caused by turning the power ON and OFF.
Timer Control with Power Start
The timer cannot take measurements until 160 to 250 ms have
elapsed after the power is turned ON (refer to the above chart). The
control output will be delayed for any set value less than 250 ms.
When the H5CL is used with power start in F mode (i.e., accumulative operation with output on hold), there will be a timer error
(approximately 100 ms each time the H5CL is turned on) due to the
characteristics of the internal circuitry.
Use the H5CL with signal start if timer accuracy is required.
Transistor Output
The transistor output of the H5CL is insulated from the internal circuitry by a photocoupler, so the transistor output can be used as
both NPN and PNP output.
The diode connected to the collector of the output transistor is used
to absorb inverted voltage that is generated when an inductive load
is connected to the H5CL.
Timer
Power for load
Self-diagnostic Function
The following displays will appear if an error occurs.
Error
e1
CPU
e2
Memory
(see note)
Output
status
OFF
Correction
Set value
after
correction
Press RST
Key or turn
power off
and then
ON
No change
0
This includes times when the life of the EEPROM has expired.
Operating Environment
When using the Timer in an area with excess electronic noise, separate the Timer, wiring, and the equipment which generates the input
signals as far as possible from the noise sources. It is also recommended to shield the input signal wiring to prevent electronic interference.
Organic solvents (such as paint thinner), as well as very acidic or
basic solutions can damage the outer casing of the Timer.
10
Reset with a Preset Value of 0
The output will go ON when the start signal is input. The output will
be OFF while the reset key is pressed or the reset input is ON.
Power Failure Backup
All data is stored in the EEPROM when there is power failure. The
EEPROM can be overwritten more than 200,000 times.
Operating
mode
Overwriting timing
A mode
When the H5CL is turned off after changing
the set value.
F mode
When the H5CL is turned off after changing
the set value, turning the start input, or the
reset input ON.
Flush Mounting
The H5CL’s panel surface is water-resistive (conforming to NEMA 4
(indoors) and IP66). In order to prevent the internal circuit from water penetration through the space between the timer and operating
panel, attach a rubber packing (provided with the H5CL) between
the timer and operating panel and secure the rubber packing with
the Y92F-30 flush-mounting adapter.
0.5 to 1 mm
Inductive load
Power for load
Note:
When changing the preset value during a timing operation, output
will turn ON if the preset value is changed as follows, since the constant read-in system is in use:
Display mode UP:
Present value ≥ preset value
Display mode DOWN: Elapse time ≥ preset value
(Present value = 0)
Note: When in down mode, the changed amount of preset value
is added to or subtracted from the present value.
Timer
Load
Display
Preset Value Change
Other
É
It is recommended that the space between
the screw head and the adapter should be
0.5 to 1 mm.
In case of performing a dielectric strength test, etc., on the H5CL
mounted to a control panel, disconnect the H5CL from the connecting circuit, or short-circuit all the terminals of the H5CL.
Otherwise the H5CL may be damaged.
Terminal 1 (power supply terminal) and terminal 6 (input common:
0 V for input) of DC model H5CL are internally connected to each
other.
DIP Switch Selection
DIP switch setting while the H5CL is turned on will not be valid until
the H5CL is turned off and on.
H5CL
H5CL
11
H5CL
H5CL
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. L085-E1-3
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
Measuring and Supervisory Controls Division
28th Fl., Crystal Tower Bldg.,
1-2-27, Shiromi, Chuo-ku,
Osaka 540-6028 Japan
Tel: (81)6-6949-6035 Fax: (81)6-6949-6069
12
Printed in Japan
1099-0.1M (0696)