omron.com

Picking Sensor
F3W-D
CSM_F3W-D_DS_E_2_1
Compact, Resistant to Mutual
Interference, and Ideal for Picking a
Variety of Parts.
• Mounts to a parts rack and uses indicators to show parts
picking procedures. Functions as a mistake-proofing
Sensor.
• Use either the built-in LED indicators or external picking
indicators.
Be sure to read Safety Precautions on
page 7.
Features
Sensing Distance of 3 m
Selectable Display Mode: All Lighting,
All Flashing, Elevator-like Lighting,
Accordion-like Lighting
External Picking Indicators Can Be
Connected
An external indicator can be directly connected to the Picking Sensor
and mounted in an easy-to-see location.
• Six picking indicators provide very clear displays.
• Selectable display speed (slow/fast)
All lit
All flashing
Elevator effect
Accordion effect
F3W-D052@P
External
indicator
1
F3W-D
Ordering Information
Sensors
Sensing
method
Infrared LED
Connection
method
(cable length)
Appearance
Sensing
distance
Beams
Gap
Qty
Sensing
width
(mm)
External
indicator
Output type
---
Model
F3W-D052A *1
Pre-wired (5 m)
Throughbeam
3 m 25 mm
5
100
Possible F3W-D052AP*1
NPN open
collector
---
Pre-wired
connector (2 m)
F3W-D052B *1, 2
Possible F3W-D052BP*1, 2
*1. Models with PNP outputs are also available. To order PNP Models, replace A with C in the model number for a Pre-wired Model and B with D in the model number
for a Pre-wired Connector Model (Example: F3W-D052C).
*2. The XS2F-D521-@G0 is the applicable connector cable. The colors of the external sheathes of the conductors, however, are different. Refer to the XS2.
Accessories (Order Separately)
Mounting Brackets
Appearance
Model
Qty
Remarks
2
L-shaped Mounting
Bracket
(mounting screws
included)
Y-shaped Joint Plugs and Sockets
(Cable with Connectors on Both Ends)
Appearance
F39-L10
F39-L11
2
Flat Mounting
Bracket
(mounting screws
included)
F39-L12
Qty
2m
XS2R-D526
-S001-2
1
5m
XS2R-D526
-S001-5
1
Appearance
Model
XS2R-D526
-S003
Model
Model
Y-shaped Joint Plugs and Sockets without Cable
Protective Bracket
Appearance
Overall
length
Qty
Qty
1
Remarks
Connecting cable:
• Cable with connectors
on both ends: XS2W
Series
• Cable with connector on
one end: XS2F Series
4-conductor models
One each for Emitter and
Receiver
(mounting screws
included)
2
2
F3W-D
Ratings and Specifications
Sensing method
Item
Through-beam
Model
F3W-D052A (P) *1
F3W-D052B (P) *1
Sensing distance
3 m, switchable between LONG mode (1 to 3 m) and SHORT mode: (0.05 to 1 m), factory-set to SHORT mode.
Beam gap
25 mm
Number of beams
5
Sensing width
100 mm
Standard sensing object Opaque, 35 mm dia. min.
Light source
(emission wavelength)
Infrared LED (860 nm)
Power supply voltage
12 to 24 VDC±10% (ripple (p-p): 10% max.)
Power consumption
Emitter: 0.6 W max., Receiver: 0.7 W max.
Control output
NPN open collector with 100 mA max. at 30 VDC
NPN open collector output type
Dark-ON or Light-ON (selectable)
Picking instruction
indicator input
Open collector with relay or transistor input
Indicator ON: Input voltage of 0 to 2 V
Indicator OFF: Open (with leakage current of 0.1 mA max.)
Protection circuits
Reverse-connection protection, output short protection, and mutual interference prevention function
(set with frequency switch)
Response time
Operate/Reset: 10 ms max.
Receiver
Operation indicator (orange), stability indicator (green), and 6 picking indicators (orange),
UNI-WIRE Direct Connection Models: Transmission indicator (orange) *2
Emitter
Power indicator (green), different frequency indicator (green), and 6 picking indicators (orange),
UNI-WIRE Direct Connection Models: Transmission indicator (orange) *2
Indicators
Ambient temperature
Operating: −10° to 55°C, Storage: −25° to 70°C (with no icing or condensation)
Ambient humidity
35% to 85% (with no condensation)
Insulation resistance
20 MΩ min. (at 500 VDC)
Dielectric strength
1,000 VAC 50/60 Hz for 1 min
Vibration resistance
(destruction)
10 to 50 Hz, 1.5-mm double-amplitude for 2 hours each in X, Y and Z directions
Shock resistance
(destruction)
500 m/s2, 3 times each in X, Y and Z directions
Degree of protection
IEC60529: IP62 (with the operation cover closed)
Connection method
Pre-wired
Standard cable length: 5 m *3
Pre-wired connector
(M12 5-pin connector)
Standard cable length: 2 m *3
Weight (packed state)
Approx. 360 g
Approx. 230 g
Materials
Case,
indicator
windows
ABS resin
Lens
Acrylic resin
Operation
cover
Nylon (PA6)
Accessories
Instruction manual
*1. The F3W-D052@P Emitters are provided with the external picking indicator output line shown in the following table.
Item
F3W-D052AP, F3W-D052BP
Connection method
Pre-wired (standard cable length: 300 mm)
Electrical specifications
Output current: 50 mA max.
Output voltage: Fixed at Sensor power supply voltage
*2. The transmission indicator indicates bus transmission status.
*3. The following cable lengths are also available.
F3W-D052A (P): 2 m, 7 m
F3W-D052B (P): 1 m, 3.5 m
3
3
F3W-D
Engineering Data (Typical)
Parallel Operating Range
Angle Characteristics
LONG Mode
LONG Mode: Tilt
(1)
400
(2)
10
Angle θ (°)
Angle θ (°)
Distance Y (mm)
600
LONG Mode: Rotation
8
(2)
6
15
10
(2)
4
200
5
2
(1)
0
2
4
6
8
0
10
Distance X
(m)
−200
2
4
6
8
Distance X
(m)
−2
(1)
1
2
3
4
5
6
7
−5
−4
−6
−400
0
10
8
9
Distance X
(m)
−10
−8
−10
−600
(1)
150
SHORT Mode: Rotation
15
Angle θ (°)
200
Distance Y (mm)
−15
SHORT Mode: Tilt
Angle θ (°)
SHORT Mode
10
(2)
100
15
10
(2)
(2)
5
(1)
1
5
50
(1)
0
0.5
1
1.5
2
2.5
3
3.5
4
Distance X
(m)
−50
0
0.5
1
1.5
2
−5
2.5
3
3.5
Distance X
(m)
−100
−10
−150
−200
0.5
1
1.5
2
2.5
3
3.5
−5
Distance X
(m)
−10
−15
(1) Horizontal Movement (2) Vertical Movement
Characteristics
Characteristics
0
−15
(1) Emitter Angle Characteristics
X
(2) Receiver Angle Characteristics
X
or
Y
θ
θ
θ
θ
Y
X
or
Tilt
Rotation
X
X
Tilt
Rotation
X
4
4
F3W-D
I/O Circuits
NPN Open-collector Outputs
Operation
mode
Model
Timing chart
Mode
selector
switch
Output circuit
F3W-D052A@-L/B@-L
Six
picking
Power
indicators indicator
(orange) (green)
Dark-ON mode
F3W-D052A@-D/B@-D
Different
frequency
indicator
(green)
5
Orange/purple
stripe
Orange/purple
stripe
Stability Operation Six picking
indicator indicator indicators
(green) (orange) (orange)
5
(Sync line)
⎛
⎜
⎜
⎜
⎜
⎜
⎜
⎜
⎝
ON:
One beam
or more is
interrupted
OFF:
No beam is
interrupted
⎞
⎟
⎟
⎟
⎟
⎟
⎟
⎟
⎠
No beam is interrupted
Light
incident One beam or more is interrupted
Operation indicator
ON
(orange)
OFF
Control output
Load (relay, etc.)
ON
OFF
Operate
Reset
Brown
D-ON
(DARK
ON)
ON:
No beam is
interrupted
OFF:
One beam
or more is
interrupted
⎞
⎟
⎟
⎟
⎟
⎟
⎟
⎟
⎠
Emitter
main
circuit
1
External picking
indicator output
Load
12 to 24
VDC
5V
Pink
Brown
1
*2
2
50 mA max.
Blue
2
*2
Blue
F3W
-D052A
F3W
-D052AP
F3W
-D052B
F3W
-D052BP Light-ON mode
⎛
⎜
⎜
⎜
⎜
⎜
⎜
⎜
⎝
Brown
1
3
Picking
instruction
input
Load
(Control
Black
output)
4
100 mA
max.
Pink
2
Blue
Receiver
main
circuit
5V
3
*1
Note: The circled numbers represent the pin numbers for Pre-wired Connector
Models.
*1. The sections surrounded by single-dashed lines are applicable to the F3WD052AP-L/BP-L only.
*2. The circled numbers represent external picking indicator output pin
numbers.
No beam is interrupted
Light
incident One beam or more is interrupted
Operation indicator
ON
(orange)
OFF
Control output
Load (relay, etc.)
ON
OFF
Operate
Reset
L-ON
(LIGHT
ON)
The following diagram shows the relationship between the picking instruction input, picking indicator status, and external picking indicator
output. DIP switch 1 is used to switch the picking display mode between all lighting, all flashing, elevator-like lighting, and accordionlike lighting. It is also possible to switch the external picking indicator
display mode between lighting and flashing.
Picking instruction Open
input
0V
ON
Picking indicator
(orange)
OFF
External picking
ON
indicator output
OFF
5
5
F3W-D
Setting Method
NPN Open-collector Output Models
DIP Switch 1 Mode Switching
Emitters
DIP
switch 1
1
2
3
4
5
6
Receivers
OFF (left)
(
)
Function
ON (right)
(
)
1 Flash Pattern
2 (picking display mode setting)
See table below. *1
Flash Time *2
3 (picking indicator flashing speed
setting)
Slow
Fast
External Flash Pattern
4 (external picking display mode
setting) *3
Lit
Flashing
5 Not used.
---
6 Frequency Setting *4
DIP
switch 1
1
2
3
4
5
6
---
OFF (left)
(
)
ON (right)
(
)
1 Flash Pattern
2 (picking display mode setting)
See table below. *1
Flash Time *2
3 (picking indicator flashing speed
setting)
Slow
Fast
Dark-ON
Light-ON
LONG
mode
(1 to 3 m)
SHORT
mode
(0.05 to 1 m)
---
---
4 Operation mode setting
5
A
B
(frequency A) (frequency B)
Function
Sensing distance (sensitivity)
setting
6 NC
*1. DIP Switch 1 Picking Display Mode Setting
DIP
switch 1
1
2
3
4
5
6
SW
1-1
SW
1-2
OFF
OFF
All lighting
(All six indicators light.)
ON
OFF
All flashing
(All six indictors flash simultaneously.)
OFF
ON
Elevator-like lighting
(Two adjacent indicators simultaneously
light so that lighting moves up and down.)
ON
ON
Accordion-like lighting
(Some or all indicators simultaneously light
so that lighting moves like an accordion.)
Display mode
• Elevator-like Lighting Mode
Changes in Indicators
LED1
LED2
LED3
LED4
LED5
LED6
Not lit
Lit
• Accordion-like Lighting Mode
Changes in Indicators
LED1
LED2
LED3
LED4
LED5
LED6
*2. The flashing speed can be changed in picking display mode (all flashing,
elevator-like lighting, or accordion-like lighting) or in external picking display
mode. The flashing speed varies with each display mode.
*3. This setting is supported for F3W-D052@P-L Emitters only.
*4. Mutual Interference Prevention Function:
The frequency selector is used to switch the emitting frequency between A
and B. Making the emitting frequencies of two Sensors different helps
prevent malfunction caused by mutual interference.
6
6
F3W-D
Nomenclature
NPN Open Collector Output Models
Emitter
F3W-D052A(P)-L
F3W-D052B(P)-L
Receiver
F3W-D052A(P)-D
F3W-D052B(P)-D
Picking
indicators
(orange)
Detection
side
Operation
cover
Operation
cover
DIP switch 1
mode setting
switch
Operation
indicator
(orange)
Power
indicator
(green)
Different
frequency
indicator (green)
Stability
indicator
(green)
Safety Precautions
Refer to Warranty and Limitations of Liability.
Precautions for Correct Use
WARNING
Do not use the product in atmospheres or environments that exceed
product ratings.
Do not apply the F3W-D as safety mechanisms used
in pressing machines or any other safety
mechanisms for protecting the human body from
danger.
● System Design
Mutual Interference Prevention Function
(1) Two Sets of Sensors:
Set these Sensors to different frequencies with the frequency
selector. Refer to DIP Switch 1 Mode Switching on page 6.
If the mutual interference prevention function is not used, and there
are two Sensors with the same frequency setting, a beam from the
Emitter of one Sensor may hit the Receiver of the other Sensor,
resulting in malfunction.
This function cannot prevent mutual interference between the F3W-D
Sensor and a Photoelectric Sensor of a different model.
(2) Three or More Sets of Sensors:
When 3 or more sets of Sensors are used in parallel, mutual
interference may result in malfunction. Take the following measures
to prevent mutual interference, and check for mutual interference.
While in LONG mode, the Sensors are more easily affected by
interference. Therefore, if the distance between the Emitter and
Receiver of a Sensor is 1 m or less, use the SHORT mode.
(1) Do not apply the F3W-D as safety mechanisms used in pressing
machines, shears, rolling machines, spinning machines, cotton
mill machines, or robots for the protection of an operator’s hands
and body.
(2) The F3W-D is designed for detection of the human body or moving
objects in the detection area but not for protection against danger.
(3) The F3W-D or any product incorporating the F3W-D may be
exported to any country. Should the F3W-D cause any problem
conflicting with local laws or related to product liability locally,
however, OMRON shall, without exception, assume no
responsibility for it.
CAUTION
Before using more than one F3W-D Sensor in parallel or series, take
necessary countermeasures against mutual interference so that the
Sensors will not malfunction. Refer to Mutual Interference Prevention
Function on the right.
Precautions for Safe Use
● Operating Environment
• Do not use the Sensor in an environment containing flammable or
volatile gases.
• Do not use the Sensor underwater.
• Do not disassemble, repair, or modify the Sensor.
• Always turn OFF the system power before installing or replacing the
Sensor.
7
7
F3W-D
• Install the Emitter and Receiver in the same orientation as shown in
the following figure. (The cables must be in the same direction.)
• The distance between two adjacent sets of Sensors must be at
least l1 or l2, which does not cause mutual interference between two
Sensors with the same frequency setting. l1 or l2 is at least 1.5 times
the distance shown in Parallel Operating Range of the Engineering
Data.
Vertical Installation
Emitter
Receiver
Emitter
Receiver
Horizontal Installation
Receiver
Emitter
l1
Emitter
• Use M4 screws to secure the Sensor body.
• Secure the case to a tightening torque of 1.2 N·m or less.
Receiver
Reflection from Wall or Floor
Emitter
l2
Receiver
Emitter
If the Emitter and Receiver are installed as shown in the following
illustration, all the axes may not be interrupted due to light reflection
from the floor or wall. Make sure that the Emitter and Receiver detect
the sensing object properly before using the F3W-D in actual
operation.
Receiver
Distance X
Side View
Sensing object
Floor
n
ectio
t refl
Ligh
Emitter
Receiver
Receiver
Wall
Emitter
Receiver
Emitter
● Adjustment
Operation and Stability Status Display
Receiver
• The following illustration shows the indicator status corresponding
to each incident level.
• Install the Receiver so that the green stability indicators are both
ON in light receiving status.
Baffle
Baffle
Emitter
Receiver
Wall
• Install a baffle so that there will not be mutual interference between
Sensors with the same frequency setting. (See Figure 1.)
A light reflection from the wall or floor may go around a baffle and
reach the Receivers. Install a baffle so that it will also block any light
reflection. (See Figure 2.)
Emitter
Top View
Emitter
Distance X
Wall
Receiver
Emitter
Receiver
Emitter
Amount of
light received
Receiver
*
Stable lightreceiving area
Baffle
Figure 1
Unstable lightreceiving area
Figure 2
Light-shielded area
● Wiring Precautions
Connection
Stability indicator
(green)
Operation indicator (orange)
Light-ON
Dark-ON
ON
ON
OFF
OFF
ON
Operating level
× 1.2
Operating level
OFF
* If the Receiver is set to the stable light-receiving area, it will become more
resistant to environmental fluctuations such as temperature, voltage, dust, and
setting deviation after installation. For applications where a stable light-receiving
area is not obtained, attention must be paid to environmental fluctuations.
• Before turning ON the power, make sure that the supply voltage is
within the maximum allowable voltage range.
• Always connect the sync lines.
• Be very careful not to get metal chips in the connector, especially
during wiring.
• Incorrect wiring may damage the equipment. Make sure that the
cable length and routing are appropriate to prevent the connectors
and cables from getting disconnected.
• Always leave the operation cover closed during operation.
• Applying excessive force to the mode switch may result in damage.
Do not apply a force of more than 5 N.
Error Display
F3W-D052 Picking Sensors are provided with only
one error display mode.
If an error occurs, the indicator on the Sensor’s
Receiver, as indicated by the arrow in the diagram
on the right, will flash.
The error indicated in this example is a
synchronization error.
Cables
The possible causes are as follows:
1. The sync line is not connected.
2. The sync line is shorted with another line.
Make sure that the bending radius is 25 mm or more.
● Installation Precautions
Installation
• Install the Sensor so that its sensing face will not receive light from
the sun, fluorescent lamps, incandescent lamps, and other light
sources.
• Do not strike the Sensor with a hammer or any other tool during
installation, otherwise the internal circuits of the Sensor may be
damaged.
8
8
F3W-D
Dimensions
(Unit: mm)
Sensors
F3W-D
Emitter
F3W-D052A(P)-L
F3W-D052B(P)-L
F3W-D052@P-L
30
14
Vinyl-insulated round
cable, 4 dia.
Standard length: 300 mm
30
1
Two, M4 nut holes (Depth: 1 mm)
Six picking indicators (orange)
Two, 4.5 dia.
Two, M4 nut holes
(Depth: 3.5 mm)
Mounting Hole
Dimensions
Two, M4 holes
Five lenses,
6.5 dia.
45
Five
beams
9
140
100 130
130±0.15
77.5
25
F3W-D052B(P)-L:
4.5
4.5
15
8.5
5
Vinyl-insulated round
cable with four conductors,
4 dia.
Conductor: 0.2 mm2
Insulation: 1.1 mm dia.
Standard length: 5 m
Vinyl-insulated
round cable,
4 dia.
Standard
length: 2 m
Power indicator (green)
Different frequency indicator (green)
45°
2
18±0.1
15.75
6
18
4.7 10
44.7
5 poles
M12 × 1
14.9 dia.
Receiver
F3W-D052A(P)-D
F3W-D052B(P)-D
Two, M4 nut holes (Depth: 1 mm)
Two, 4.5 dia.
Two, M4 nut holes
(Depth: 3.5 mm)
30
1
Six picking indicators (orange)
Mounting Hole
Dimensions
Two, M4 holes
Five lenses,
6.5 dia.
45
Five
beams
9
140
130 100
130±0.15
77.5
25
F3W-D052B(P)-D:
4.5
4.5
15
8.5
5
45°
Vinyl-insulated round
cable with five conductors,
4 dia.
Conductor: 0.2 mm2
Insulation: 1.1 mm dia.
Standard length: 5 m
Vinyl-insulated
round cable,
4 dia.
Standard
length: 2 m
44.7
5 poles
2
15.75
18
Operation indicator (orange)
Stability indicator (green)
18±0.1
6
104.7
M12 × 1
14.9 dia.
9
9
F3W-D
Accessories (Sold Separately)
Mounting Brackets
F39-L10 (L-shaped)
Mounting Bracket Attached
30
110 130
140 130 114
Four
mounting
holes
15
4.8
10.8
Material: Iron
(Thickness: 2 mm)
Mounting screws provided.
110 130
100
Four, 4.8 dia.
13
22
18
42
18
20.25
10
Five
5
beams
23
5
2
Mounting Brackets
F39-L11 (Flat)
Mounting Bracket Attached
75
45
30
140 130 114
80
Four
mounting
holes
100
100
80
4.8
10
15
Material: Iron
(Thickness: 2 mm)
Mounting screws provided.
10.8
Four, 4.8 dia.
6
18
21
20
2
20
23.25
Five 5
optical
axes
10
10
F3W-D
Protective Bracket
F39-L12 (Receiver)
Mounting Bracket Attached
Five, 10 dia. 10.6
8.1
14
45
144 130 100
100
6
130
40.5
77.5
6
7.6
47
13
15
15
14
7
Five
beams
12.7
4.5
7
Material: Iron
(Thickness: 1.6 mm)
Mounting screws provided.
15.75
8.1
Two, 9.5 dia.
8.6
18
15.75
18
Installation panel
14.2
Note: The Emitter and Receiver are axially
symmetrical.
35.2
1.6
Y-shaped Joint Plugs and Sockets (Cable with Connectors on Both Ends)
XS2R-D526-S001-2 (L=2,000 mm)
4.6 dia.
XS2R-D526-S001-5 (L=5,000 mm)
15
1 2
5
4 3
35
Wiring Diagram
Flameproof cable (UL2464)
with four conductors, 6 dia.
(110/0.08 dia.)
Nominal wire diameter:
AWG20
CN0
45.5
CN1
4
1
18
1 2
5
4 3
1
2
CN2 3
4
5
8.5 dia.
CN2
44.7
13.6
L
3
2
1
2
3
4
CN0
1
2
CN1 3
4
5
Blue marking
Y-shaped Joint Plugs and Sockets without Cable
XS2R-D526-S003
Wiring Diagram
1
2
CN2 3
4
5
27
7
15
1 2
5
4 3
(37)
4.5 dia.
CN2
CN0
24.5
18
2
1
5
4 3
2
3
4 1
12.5
CN1
58.3
Blue marking
1
2
CN1 3
4
5
1
2
3
4
CN0
11
11
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
 Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
 Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
 Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2012.4
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/