G3VM-61PR1 MOS FET Relays Smallest Class in market, USOP Package MOS FET Relays with Low Output Capacitance and ON Resistance (CxR=7pF·Ω) • Dielectric strength of 500Vrms between I/O. Note: The actual product is marked differently from the image shown here. RoHS Compliant Refer to "Common Precautions". ■Application Examples ■Terminal Arrangement/Internal Connections • Communication • Semiconductor test OMRON mark • Data loggers • Test & measurement Model name 6P1 equipment equipment LOT No. 103 equipment Note: The actual product is marked differently from the image shown here. ■List of Models Package type USOP4 Contact form 1a (SPST-NO) Load voltage (peak value) (See note.) Terminals Minimum package quantity Model Number per tape & reel − G3VM-61PR1 Surface-mounting terminals 60V G3VM-61PR1(TR05) 500 G3VM-61PR1(TR) 1,500 Note 1. Ask you OMRON representative for orders under 1,500 pcs or 500 pcs. 2. Tape-cut USOPs are packaged without humidity resistance. Use manual soldering to mount them. Refer to common precautions. 3. The AC peak and DC value is given for the load voltages. ■Absolute Maximum Ratings (Ta = 25°C) LED forward current reduction rate LED reverse voltage Connection temperature Load voltage (AC peak/DC) Output G 3 V M I 6 1 P R 1 Item LED forward current Input U S O P Continuous load current (AC peak/DC) Symbol Rating Unit IF 50 mA ΔIF/°C −0.5 mA/°C VR 5 V °C TJ 125 VOFF 60 V IO 120 mA ΔIO/°C −1.2 mA/°C Pulse ON current lop 360 mA Connection temperature TJ 125 °C ON current reduction rate Measurement conditions Ta≥25°C Ta≥25°C t=100ms, Duty=1/10 Dielectric strength between I/O (See note 1.) VI-O 500 Vrms Ambient operating temperature Ta −40~+85 °C Tstg −40~+125 °C With no icing or condensation − 260 °C 10s Ambient storage temperature Soldering temperature AC for 1 min With no icing or condensation Note: 1.The dielectric strength between the input and output was checked by applying voltage between all pins as a group on the LED side and all pins as a group on the lightreceiving side. ■Electrical Characteristics (Ta = 25°C) Item Symbol Minimum Typical Maximum Unit Measurement conditions Input Output LED forward voltage VF 1.0 1.15 1.3 V IF=10mA Reverse current IR − − 10 μA VR=5V Capacity between terminals CT − 15 − pF V=0, f=1MHz Trigger LED forward current IFT − 1.0 3 mA IO=100mA Maximum resistance with output ON RON − 10 15 Ω IF=5mA, IO=120mA, t<1s Current leakage when the relay is open ILEAK − − 1 nA VOFF=60V Capacity between terminals V=0, f=100MHz, t<1s COFF − 0.7 1.3 pF Capacity between I/O terminals CI-O − 0.4 − pF f=1MHz, VS=0V Insulation resistance between I/O terminals RI-O 1000 − − MΩ VI-O=500VDC, ROH≤60% Turn-ON time tON − 0.04 0.2 ms Turn-OFF time tOFF − 0.12 0.2 ms IF=5mA, RL=200Ω, VDD=20V (See note 2.) 1 Note: 2.Turn-ON and Turn-OFF Times IF 1 4 2 3 RL VDD VOUT IF VOUT 10% t ON 90% t OFF G3VM-61PR1 MOS FET Relays ■Recommended Operating Conditions Use the G3VM under the following conditions so that the Relay will operate properly Item Symbol Minimum Typical Maximum VDD − − 48 V IF 5 7.5 20 mA Load voltage (AC peak/DC) Operating LED forward current Unit Continuous load current (AC peak/DC) IO − − 120 mA Ambient operating temperature Ta −20 − 65 °C ■Engineering Data Continuous load current vs. Ambient temperature LED forward current vs. Ambient temperature IO - Ta 60 50 40 30 20 IF - VF 150 LED forward current IF (mA) Continuous load current IO (mA) IF - Ta LED forward current IF (mA) LED forward current vs. LED forward voltage 100 50 100 Ta = 25°C 10 1 10 0 -40 -20 0 20 40 60 80 Continuous load current vs. On-state voltage -40 -20 0 20 IO - VON 60 80 100 IF=5mA t<1s 50 0 -50 Io=120mA IF=5mA t<1s 10 5 0.5 1 1.5 -40 -20 0 20 On-state voltage VON (V) Turn ON, Turn OFF time vs. LED forward current 1 100 -20 0 t OFF 100 10 t ON RL=200Ω Ta=25°C 1 10 100 20 40 60 80 100 Ambient temperature Ta (°C) U S O P Current leakage vs. Load voltage tON, tOFF - Ta Turn ON, Turn OFF time tON, tOFF (μs) Turn ON, Turn OFF time tON, tOFF (μs) 80 Io=100mA t<1s Ambient temperature Ta (°C) tON, tOFF - IF 1 60 Turn ON, Turn OFF time vs. Ambient temperature 1000 VDD=20V 40 ILEAK - VOFF Current leakage ILEAK (pA) 0 2 0 -40 0 -0.5 1.6 IFT - Ta 20 15 1.4 Trigger LED forward current vs. Ambient temperature -100 -1 1.2 LED forward voltage VF (V) Trigger LED forward current IFT (mA) Ta = 25°C -150 -1.5 1 RON - Ta On-state resistance RON (Ω) Continuous load current IO (mA) 40 Ambient temperature Ta (°C) On-state resistance vs. Ambient temperature 150 100 0.1 0.8 0 100 Ambient temperature Ta (°C) 1000 t OFF 100 t ON 10 100 Ta = 25°C 80 G 3 V M I 6 1 P R 1 60 40 VDD=20V 20 RL = 200Ω IF=5mA 1 -40 -20 LED forward current IF (mA) 0 20 40 60 80 100 Ambient temperature Ta (°C) 0 0 10 20 30 40 50 60 Load voltage VOFF(v) Output terminal capacitance COFF/COFF(ov) vs. Load voltage Output terminal capacitance COFF/COFF(ov) COFF - VOFF 1 Ta = 25°C 0.8 0.6 0.4 0.2 0 0 10 20 30 40 Load voltage VOFF(v) ■Safety Precautions • Refer to "Common Precautions" for all G3VM models. 2 Apperance/Dimensions USOP4 ■Appearance USOP (Ultra Small Outline Package) USOP4 6P1 Model name OMRON mark 103 LOT No. Note: The actual product is marked differently from the image shown here. ■Dimensions 6P1 (Unit: mm) Surface-mounting Terminals 103 Actual Mounting Pad Dimensions Weight: 0.03g (Recommended Value, Top View) 3.25 2.05 0.85 2.9 0.15 1.65 (0.4) 1.27 2.2 0.8 0.2 2.85 1.27 (0.35) Note: The actual product is marked differently from the image shown here. • Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. • Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation ELECTRONIC AND MECHANICAL COMPONENTS COMPANY Contact: www.omron.com/ecb Cat. No. K212-E1-02 1112(0912)(O)