NX-Series Modular I/O System Connecting to Open Industrial Network Standards » Choice of functionality and performance. » Integration of Standard I/O and Safety » Intuitive and efficient safety programming with PLCopen functions 2 Choice of networks The NX-series Communication Coupler Units support global open networks. Select the network that best suits your needs. Lineup of Communication Coupler Units EtherNet/IP Communication Coupler Unit EtherNet/IP uses the Common Industrial NX-EIC202 Protocol (CIP TM) over a standard Ethernet infrastructure. The EtherNet/IP Coupler has a built-in Ethernet switch and two RJ45 ports, to daisy-chain I/O stations without additional hardware. Data exchange over EtherNet/IP uses data links with configurable update cycles, allowing a trade-off between performance and data capacity for each individual link. For details on EtherNet/IP, refer to the EtherNet/IP Catalog (R150). EtherCAT Communication Coupler Unit NX-ECC202 EtherCAT uses Ethernet as a dedicated control network. With a pure MasterSlave architecture and on-the-fly data exchange, it offers unparalleled communication efficiency. EtherCAT's distributed real-time clock and time-stamping of I/O data help to achieve multi-axis synchronised machine control with less than 1 us jitter. *For details, refer to the Sysmac Catalog (P072). Windows is registered trademarks of Microsoft Corporation in the USA and other countries. EtherCAT® is registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany. EtherNet/IPTM is the trademarks of ODVA. Other company names and product names in this document are the trademarks or registered trademarks of their respective companies. Microsoft product screen shots reprinted with permission from Microsoft Corporation. 3 NX Series The NX Series is a range of modular designed units that integrate standard I/O and safety and connect to the EtherNet/IP network via Communication Coupler Units. INDE X Features 1. Integrated control Standard I/O and safety units can be mixed within an I/O station. 2. Integrated design environment Machine and safety control can be >P >P IEC 61131-3 function blocks for safety control, as recommended by PLCopen, are supported. 4. Saving space Modular design allows the minimum width of the standard I/O unit to be 12 mm. >P 8 One I/O system for various controllers >P 10 System Configuration/ Configuration Unit Space can be reduced by 70% compared to the existing terminal blocks. (OMRON investigation) 6 The Safety solution for any application designed using one software. 3. Conforming to IEC 61131-3 standard 4 Distributed I/O: the choice is yours >P 12 EtherNet/IP Coupler Unit 4 Distributed I/O: the choice is yours. The modern remote I/O demands increasing levels of flexibility. The EtherNet/IP Communication Unit enables connection between the CJ-series or other Programmable Controller and NX-series I/O through EtherNet/IP, which expands system configuration possibilities. Modular remote I/O systems offer flexibility in I/O configuration and a wide choice of signal types and performance levels so that every I/O station can be assembled with just the right combination without changing the control architecture. By using standard Ethernet cables and connectors, only basic tools are required to install and maintain networks. Features Wide choice : More than 100 types of I/O unit, from 2 to 32 points in one unit. Compact design : Up to 16 digital signals in 12 mm width. Safety integrated : Mix safety controllers and safety I/O's with standard I/O's. EtherNet/IP EtherNet/IP is supported by many control system vendors, and its specification is governed by the Open DeviceNet Vendors Association (ODVA). The CIP protocol has proven its reliability in DeviceNet and CompoNet installations worldwide. 5 Various PLC vender like CJ series Up to 63 Units per communication ation coupl coupler Ty Types of standard NX I/O Units N • Digital Input/Output Units Input/Output Units • Temperature Input Units • Encoder/Positioning Units • Power supply and connection Units • Analog Quick connections • Detachable screwless terminal block for easy commissioning and maintenance • Push-in connections speed up installation • MIL connectors for high-density I/O Safety Integrated The NX-series safety controller and I/O units can be mixed with standard I/O's to create a complete modular safety control system. 6 The Safety solution for any application As machine automation evolves the need for diversity in configurations will increase. OEM’s and end-users need the ability to design highly flexibly system that have safety and can integrate with a variety of PLC’s to meet the demands of evolving automation. Features Realize safety-related system of all machine Automation Software Sysmac Studio NX I/O Edition of customer • Flexible hardware • Flexible Programming • Standardization • Simplify • Ensure and reuse safety system safety system trouble shooting Simulate Safety System Offline simulator to debug safety system including feedback monitoring of safety output circuits Various PLC vender like CJ series Standardization Flexible Programming Easy design to cover various safety options. Powerful safety logic editor. Ensure trouble shooting Deliver problem analysis as Why, What, Where and Navigate How to fix. 7 Safety Control Units • EN ISO13849-1 (PLe/Safety Category 4), IEC 61508 (SIL3) certified. • 4 or 8 points per Safety Input Unit. 2 or 4 points per Safety Output Unit. • The Safety Units can be freely allocated in any combination with standard NX I/O. Modular design • Small system size allows space savings in the cabinet. ISO 13849-1, PLe • Direct Diagnostic with LED's. IEC 61508, SIL3 • Easy wiring and easy to maintain. Flexible layout with safety and standard units Connecting directly to most safety components 8 One I/O system for various controllers. While different machines may require different levels of controller performance, NX-series is the only remote I/O system you will need. This will unify wiring and Low-end Machine installation techniques, and simplify spare parts stock. Safety control programs that are created using the NX I/O Edition can be standardized and reused throughout the machine portfolio, which will reduce the time required for development, testing and certification. FA Integrated Tool Package CX-One Various PLC vender like CJ series Stand Alone Safety System Automation Software Sysmac Studio NX I/O Edition 9 Same Manner for Safety Design Common Software & Common Hardware High-performance Machine Automation Software Sysmac Studio Full edition Machine Automation Controller NJ series Integrated Safety System AC Servo motor/Driver NX-series EtherNet/IP Coupler Unit NX-EIC Connecting to open industrial network standard EtherNet/IP • The EtherNet/IP Coupler Unit is the link between the EtherNet/IP multivendor network and the NX-series I/O Units and Safety Units. With wide variety of the I/O Units and Safety Units, the NX-series is the perfect match for the CJ-series and multivendor Controllers. Features • Up to 63 NX-IO Units can be connected to one EtherNet/IP Coupler Unit. Standard and high-performance units can be mixed.* • Each Coupler plus its I/O form just a single EtherCAT node on the network. • I/O control and safety control can be integrated by connecting Units for safety. • The IP address can be found on the label on the Unit, without using software. • Slave configuration by Sysmac Studio can be done centrally via the controller, or on-the-spot using the Coupler's built-in USB port. * Input per Coupler Unit: Maximum 504 bytes, Output per Coupler Unit: Maximum 504 bytes System Configuration EtherNet/IP master CJ-series CPU Unit or master from another manufacturer EtherNet/IP port Communications cable Ethernet cables NX-series EtherNet/IP Coupler Unit NX-EIC202 Network Configurator Peripheral USB port Industrial Switching Hubs W4S1 End Cover NX Units Sysmac Studio Support Software Connection to peripheral USB port on EtherNet/IP Coupler Unit Refer to page17 for the NX Units that can be connected to the NX-series EtherNet/IP Coupler Unit. 10 NX-EIC Ordering Information International Standards • The standards are abbreviated as follows: U: UL, U1: UL(Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, CE: EC Directives, and KC: KC Registration. • Contact your OMRON representative for further details and applicable conditions for these standards. Unit type Product Name Current consumption Maximum I/O power supply current Model Standards NX-EIC202 UC1, CE, KC EtherNet/IP Coupler Unit NX Series EtherCAT Coupler Unit 1.50 W or lower 10 A Automation Software Sysmac Studio Please purchase a DVD and required number of licenses the first time you purchase the Sysmac Studio. DVDs and licenses are available individually. Each model of licenses does not include any DVD. Product name Sysmac Studio NX-I/O Edition Ver.1.@@ *1 *2 Specifications Sysmac Studio NX-I/O Edition is a limited license that provides selected functions required for EtherNet/IP Coupler settings. Because this product is a license only, you need the Sysmac Studio Standard Edition DVD media to install it. Number of licenses 1 license Model Standards --- SYSMAC-NE001L --- DVD SYSMAC-SE200D --- Media The Sysmac Studio is the software that provides an integrated environment for setting, programming, debugging and maintenance of machine automation controllers including the NJ Series, EtherCat Slave, and the HMI. Sysmac Studio Standard Edition Ver.1.@@ *2 Sysmac Studio runs on the following OS. --Windows XP (Service Pack 3 or higher, 32-bit version)/ (Media only) Windows Vista (32-bit version)/Windows 7 (32-bit/64bit version)/Windows 8 (32-bit/64-bit version)/ Windows 8.1 (32-bit/64-bit version) This software provides functions of the Vision Edition. Refer to Sysmac Catalog (P072) for details such as supported models and functions. *1. The Sysmac Studio Standard Edition with license(s) (SYSMAC-SE@@@L) provides functions of the NX-I/O Edition (SYSMAC-NE001L). *2. With the Sysmac Studio Standard Edition with license(s) (SYSMAC-SE@@@L) version 1.10 or higher, you can use the setup functions for the EtherNet/IP Coupler. 11 NX-EIC Recommended EtherNet/IP Communications Cables Use STP (shielded twisted-pair) cable of category 5 or higher for EtherNet/IP. Cabel with Connectors Item Recommended manufacturer Appearance Standard type Cable with Connectors on Both Ends (RJ45/RJ45) Wire Gauge and Number of Pairs: AWG27, 4-pair Cable Cable Sheath material: LSZH *2 Cable color: Yellow *3 Cable length(m) *1 OMRON Rugged type Cable with Connectors on Both Ends (RJ45/RJ45) Wire Gauge and Number of Pairs: AWG22, 2-pair Cable OMRON Rugged type Cable with Connectors on Both Ends (M12 Straight/RJ45) Wire Gauge and Number of Pairs: AWG22, 2-pair Cable OMRON Rugged type Cable with Connectors on Both Ends (M12 Right-angle/RJ45) Wire Gauge and Number of Pairs: AWG22, 2-pair Cable OMRON Model 0.3 XS6W-6LSZH8SS30CM-Y 0.5 XS6W-6LSZH8SS50CM-Y 1 XS6W-6LSZH8SS100CM-Y 2 XS6W-6LSZH8SS200CM-Y 3 XS6W-6LSZH8SS300CM-Y 5 XS6W-6LSZH8SS500CM-Y 0.3 XS5W-T421-AMD-K 0.5 XS5W-T421-BMD-K 1 XS5W-T421-CMD-K 2 XS5W-T421-DMD-K 5 XS5W-T421-GMD-K 10 XS5W-T421-JMD-K 0.3 XS5W-T421-AMC-K 0.5 XS5W-T421-BMC-K 1 XS5W-T421-CMC-K 2 XS5W-T421-DMC-K 5 XS5W-T421-GMC-K 10 XS5W-T421-JMC-K 0.3 XS5W-T422-AMC-K 0.5 XS5W-T422-BMC-K 1 XS5W-T422-CMC-K 2 XS5W-T422-DMC-K 5 XS5W-T422-GMC-K 10 XS5W-T422-JMC-K Note: For details, refer to Cat.No.G019. *1 Standard type cables length 0.2, 0.3, 0.5, 1, 1.5, 2, 3, 5, 7.5, 10, 15 and 20m are available. Rugged type cables length 0.3, 0.5, 1, 2, 3, 5, 10 and 15m are available. *2 The lineup features Low Smoke Zero Halogen cables for in-cabinet use and PUR cables for out-of-cabinet use. *3 Cables colors are available in blue, yellow, or Green Optional Products Product name Specification Model Pins for 10 Units Unit/Terminal Block Coding Pins (30 terminal block pins and 30 Unit pins) NX-AUX02 Standards --- Specification Product Name Terminal Block 12 No. of terminals Terminal number indications Ground terminal mark Terminal current capacity 8 A/B Provided 10 A Model NX-TBC082 Standards --- NX-EIC Accessories End Cover (NX-END01) One End Cover is provided together with the EtherNet/IP Coupler Unit. Protrusions for removing the Unit Unit hookup guide Unit hookup guide Protrusions for removing the Unit General Specification Item Enclosure Specification Mounted in a panel Grounding method Ground to 100 Ω or less Ambient operating temperature 0 to 55°C Operating environment Ambient operating humidity 10% to 95% (with no condensation or icing) Atmosphere Must be free from corrosive gases. Ambient storage temperature −25 to 70°C (with no condensation or icing) Altitude 2,000 m max. Pollution degree Pollution degree 2 or less: Conforms to JIS B 3502 and IEC 61131-2. Noise immunity Conforms to IEC 61000-4-4. 2 kV (power supply line) Overvoltage category Category II: Conforms to JIS B 3502 and IEC 61131-2. EMC immunity level Zone B Vibration resistance Conforms to IEC 60068-2-6. 5 to 8.4 Hz with 3.5-mm amplitude, 8.4 to 150 Hz, acceleration of 9.8 m/s2, 100 min each in X, Y, and Z directions (10 sweeps of 10 min each = 100 min total) Shock resistance Conforms to IEC 60068-2-27. 147 m/s2, 3 times each in X, Y, and Z directions Applicable standards cULus: Listed UL508 and ANSI/ISA 12.12.01 EC: EN 61131-2 and C-Tick 13 NX-EIC EtherNet/IP Coupler Unit Specifications Item Specification Model NX-EIC202 Number of connectable NX Units 63 Units max.*1 EtherNet/IP Number of buffers (sockets): • 8 message buffers for server • No message buffers for client • Shared buffers for UDP/IP messages and TCP/IP messages Communications protocols UDP/IP and TCP/IP (Message Services) Maximum message size: • Request: 492 bytes • Response: 496 bytes Maximum NX output data size: • 490 bytes Maximum NX input data size: • 496 bytes Modulation Baseband Link speed 100 Mbps Physical layer 100BASE-TX (IEEE 802.3) Number of connections 8 Received Packet Interval (RPI, refresh cycle) 4 to 1,000 ms Allowed communications bandwidth per Unit 1,000 pps Topology Line, Tree, Star Transmission media Category 5 or higher twisted-pair cable (Recommended cable: double-shielded cable with aluminum tape and braiding) Transmission distance Distance between nodes: 100 m or less NX bus I/O data size Input: 512 bytes max. (including input data, status, and unused areas) Output: 512 bytes max. (including output data and unused areas) EtherNet/IP I/O connection size Input: 504 bytes max. (including input data, status, and unused areas) Output: 504 bytes max. (including output data and unused areas) Refreshing methods Free-Run refreshing Power supply voltage 24 VDC (20.4 to 28.8 VDC) NX Unit power supply capacity 10 W max. Unit power supply I/O power supply NX Unit power supply efficiency 70% Isolation method No isolation between NX Unit power supply and Unit power supply terminals Current capacity of power supply terminals 4 A max. Power supply voltage 5 to 24 VDC (4.5 to 28.8 VDC) *2 Maximum I/O power supply current 10 A Current capacity of power supply terminals 10 A max. NX Unit power consumption 1.60 W max. Current consumption from I/O power supply 10 mA max. (for 24 VDC) Dielectric strength 510 VAC for 1 min, leakage current: 5 mA max. (between isolated circuits) Insulation resistance 100 VDC, 20 MΩ min. (between isolated circuits) Communications Connector For EtherNet/IP communications. • RJ45 × 2 (shielded) External connection terminals Screwless Clamping Terminal Block For Unit power supply, I/O power supply, and grounding. Removable. Peripheral USB Port For Sysmac Studio connection. • Physical layer: USB 2.0-compliant, B-type connector • Transmission distance: 5 m max. Dimensions 46 × 100 × 71 mm (W×H×D) Weight 150 g max. *1. Refer to the NX-series Safety Control Unit User's Manual (Cat. No. Z930) for the number of Safety Control Units that can be connected. *2. Use a voltage that is appropriate for the I/O circuits of the NX Units and the connected external devices. 14 NX-EIC Item Specification Installation orientation: 6 possible orientations Restrictions: • Used in the upright installation orientation. Unit power supply [W] 10 W output, 40°C 12 10 8.5 W output, 55°C 8 6 4 2 0 0 10 20 30 40 45 50 55 60 Ambient temperature [°C] • Used in any other orientation than the upright installation orientation. Unit power supply [W] 10 W output, 40 °C 12 10 Installation orientation and restrictions 8 6.0 W output, 55°C 6 4 2 0 0 10 20 30 40 45 50 55 60 Ambient temperature [°C] I/O power supply [A] 10 A current, 45°C 12 10 8 6 A current, 55°C 6 4 2 0 0 10 20 30 40 45 50 55 60 Ambient temperature [°C] 15 NX-EIC Item Specification Peripheral USB port Internal circuits IN communications connector OUT communications connector UV UV UG Circuit layout Terminal block UG UNIT PWR LED Non-isolated power supply circuits NX Unit power supply − I/O power supply + IOV IOG NX Unit power supply + NX bus connector I/O power supply − I/O PWR LED DIN Track contact plate A1 B1 UV UV UG UG IOV IOG Unit power supply (24 VDC) Terminal arrangement I/O power supply (5 to 24 VDC) Ground to 100 Ω or less. Accessory 16 End Cover (NX-END01): 1 A8 B8 Through-wiring for unwired terminals. NX-EIC Configuration Unit Refer to the user's manuals for information on the NX Units that can be connected to the NX-series EtherNet/IP Coupler Unit. EtherNet/IP Coupler Unit Unit EtherNet/IP Coupler Unit Model NX-EIC202 I/O Units Model Unit 2-point Units − Digital Input Unit NX-OC2633 NX-OC2733 Digital Output Unit 4-point Units 16-point Units 32-point Units NX-ID3317 NX-ID3343 NX-ID3417 NX-ID3443 NX-IA3117 NX-ID4342 NX-ID4442 NX-ID5142-5 NX-ID5342 NX-ID5442 NX-ID6142-5 NX-OD3121 NX-OD3153 NX-OD3256 NX-OD3257 NX-OD4121 NX-OD4256 NX-OD5121 NX-OD5121-5 NX-OD5256 NX-OD5256-5 NX-OD6121-5 NX-OD6256-5 − Digital Mixed I/O Unit 8-point Units − Analog Input Unit NX-AD2603 NX-AD2604 NX-AD2608 NX-AD2203 NX-AD2204 NX-AD2208 NX-AD3603 NX-AD3604 NX-AD3608 NX-AD3203 NX-AD3204 NX-AD3208 Analog Output Unit NX-DA2603 NX-DA2605 NX-DA2203 NX-DA2205 NX-DA3603 NX-DA3605 NX-DA3203 NX-DA3205 Temperature Input Unit NX-TS2101 NX-TS2102 NX-TS2104 NX-TS2201 NX-TS2202 NX-TS2204 NX-TS3101 NX-TS3102 NX-TS3104 NX-TS3201 NX-TS3202 NX-TS3204 NX-MD6121-5 NX-MD6256-5 − NX-AD4603 NX-AD4604 NX-AD4608 NX-AD4203 NX-AD4204 NX-AD4208 − − − − − − − − − Position Interface Unit Model Unit 1CH 2CH Incremental Encoder Input Unit NX-EC0112 NX-EC0122 NX-EC0132 NX-EC0142 NX-EC0212 NX-EC0222 SSI Input Unit NX-ECS112 NX-ECS212 Pulse Output Unit NX-PG0122 − System Units Unit Model Additional NX Unit Power Supply Unit NX-PD1000 Additional I/O Power Supply Unit NX-PF0630 NX-PF0730 I/O Power Supply Connection Unit NX-PC0010 NX-PC0020 NX-PC0030 Shield Connection Unit NX-TBX01 Safety Control Units Unit Model Safety CPU Unit NX-SL3300 *1 Safety Input Unit NX-SIH400 *2 NX-SID800 Safety Output Unit NX-SOH200 NX-SOD400 *1 Safety CPU Unit Ver.1.1 or higher. *2 Safety Input Unit Ver.1.1 or higher. Version Information NX-series EtherNet/IP Coupler Unit and Sysmac Studio Model NX-EIC202 NX Units Unit Version Ver.1.0 version Sysmac Studio Version 1.10 or later 17 NX-EIC External Interface EtherNet/IP Coupler Unit NX-EIC202 (A) (B) (D) NX-EIC202 (C) (E) F 012 789A 3456 D BC E F 012 789A 3456 (F) D BC E NET (C) (G) Letter (A) Name Function NX bus connector This connector is used to connect the EtherNet/IP Coupler Unit to the NX Unit on the right of the Coupler Unit. The indicators show the current operating status of the Unit and the status of the power supply. (B) Indicators (C) Communications connectors These connectors are connected to the communications cables of the EtherNet/IP network. (D) Peripheral USB port This port is used to connect to the Sysmac Studio. (E) Terminal block The terminal block is used to connect to the power supply cables and ground wire. (F) Rotary switches The rotary switches are used to set the last octet of the IP address of the EtherNet/IP Coupler Unit as an EtherNet/IP Slave. The address is set in hexadecimal. (G) DIP switch The DIP switch is used to set the default node address of the EtherNet/IP Coupler Unit as an EtherNet/IP slave. Terminal Block (A) (B) A1 B1 A2 B2 A3 B3 A4 B4 A5 B5 A6 B6 A7 B7 A8 B8 (C) Eight-terminal Block Symbol Name Function The terminal numbers (A1 to A8 and B1 to B8) are displayed. Terminal number indications The terminal number indicators are the same regardless of the number of terminals on the terminal block, as shown above. (B) Release holes Insert a flat-blade screwdriver into these holes to connect and remove the wires. (C) Terminal holes The wires are inserted into these holes. (A) 18 NX-EIC Applicable Wires Using Ferrules If you use ferrules, attach the twisted wires to them. Observe the application instructions for your ferrules for the wire stripping length when attaching ferrules. Always use plated one-pin ferrules. Do not use unplated ferrules or two-pin ferrules. The applicable ferrules, wires, and crimping tool are given in the following table. Terminal types Manufacturer Terminals other than ground terminals Phoenix Contact Applicable wire (mm2 (AWG)) Ferrule model AI0,34-8 0.34 (#22) AI0,5-8 0.5 (#20) Crimping tool Phoenix Contact (The figure in parentheses is the applicable wire size.) CRIMPFOX 6 (0.25 to 6 mm2, AWG 24 to 10) AI0,5-10 AI0,75-8 0.75 (#18) AI0,75-10 AI1,0-8 1.0 (#18) AI1,0-10 AI1,5-8 1.5 (#16) AI1,5-10 Ground terminals Terminals other than ground terminals Weidmuller AI2,5-10 2.0 *1 H0.14/12 0.14 (#26) H0.25/12 0.25 (#24) H0.34/12 0.34 (#22) H0.5/14 0.5 (#20) Weidmueller (The figure in parentheses is the applicable wire size.) PZ6 Roto (0.14 to 6 mm2, AWG 26 to 10) H0.5/16 H0.75/14 0.75 (#18) H0.75/16 H1.0/14 1.0 (#18) H1.0/16 H1.5/14 1.5 (#16) H1.5/16 *1. Some AWG 14 wires exceed 2.0 mm2 and cannot be used in the screwless clamping terminal block. When you use any ferrules other than those in the above table, crimp them to the twisted wires so that the following processed dimensions are achieved. 8 to 10 mm 1.6 mm max. (Terminals other than ground terminals) 2.4 mm max. (Terminals other than ground terminals) 2.7 mm max. (Ground terminals) 2.0 mm max. (Ground terminals) Using Twisted Wires/Solid Wires If you use the twisted wires or the solid wires, use the following table to determine the correct wire specifications. Terminals Classification Current capacity Wire type Twisted wires Plated 2 A max. All terminals except ground terminals Ground terminals Greater than 2 A and 4 A or less Possible Greater than 4A Possible *1 --- Possible Solid wire Unplated Plated Unplated Possible Possible Possible Not Possible Possible Possible *1 Not Possible Possible *2 Not Possible Possible *2 Wire size Conductor length (stripping length) 0.08 to 1.5 mm2 AWG28 to 16 8 to 10 mm 2.0 mm2 9 to 10 mm *1 Secure wires to the screwless clamping terminal block. Refer to the Securing Wires in the USER'S MANUAL for how to secure wires. *2 With the NX-TB@@@1 Terminal Block, use twisted wires to connect the ground terminal. Do not use a solid wire. Conductor length (stripping length) <Additional Information> If more than 2 A will flow on the wires, use plated wires or use ferrules. 19 NX-EIC Dimensions (Unit: mm) ● EtherCAT Coupler Unit Only 48.1 46 0.55 1.5 NX-EIC202 F 012 789A 3456 D BC E 789A F 012 104.5 100 3456 D BC E NET 1.5 65.2 71 80 ● With Cables Connected *1 100 to 120 *2 5.8 71 USB cable Communications cable *1. This dimension depends on the specifications of the commercially available USB cable. Check the specifications of the USB cable that is used. *2. This is the dimension from the back of the Unit to the communications cables. • 100 mm: When an MPS588-C Connector is used. • 120 mm: When an XS6G-T421-1 Connector is used. 20 NX-EIC ● End Cover 12 1.5 100 1.5 71 Related Manuals Man. No Model Manual Application Description Learning how to use an NXseries Ether-Net/IP Coupler Unit and EtherNet/IP Slave Terminals Introduces the system, configuration methods, Unit hardware, setting methods, and functions of EtherNet/IP Slave Terminals that consist of an EtherNet/IP Coupler Unit and NX Units. W536 NX-EIC@@@ NX-series EtherNet/IP Coupler Unit User’s Manual W525 NX- NX-series Data Reference Manual Referencing lists of the data that is required to configure systems with NX-series Units Lists of the power consumptions, weights, and other NX Unit data that is required to configure systems with NX-series Units are provided. W521 NX-ID NX-IA NX-OC NX-OD NX-MD NX-series Digital I/O Units User’s Manual Learning how to use NXseries Digital I/O Units The hardware, setup methods, and functions of the NX-series Digital I/O Units are described. W522 NX-AD NX-DA NX-TS Learning how to use NXNX-series Analog I/O Units series Analog I/O Units User’s Manual and Temperature Input Units The hardware, setup methods, and functions of the NX-series Analog I/O Units and Temperature Input Units are described. W523 NX-PD1 NX-PF0 NX-PC0 NX-TBX01 NX-series System Units User’s Manual Learning how to use NXseries System Units The hardware and functions of the NX-series System Units are described. W524 NX-EC0 NX-ECS NX-PG0 NX-series Position Interface Units User’s Manual Learning how to use NXseries Position Interface Units The hardware, setup methods, and functions of the NX-series Incremental Encoder Input Units, SSI Input Units, and Pulse Output Unit are described. Z930 NX-SL NX-SI NX-SO NX-series Safety Control Unit User’s Manual Learning how to use NX- The hardware, setup methods, and functions of the series Safety Control Units NX-series Safety Control Units are described. NX-SL Learning about the NX-series Safety Control specifications of Unit Instructions Reference instructions for the Safety Manual CPU Unit. Z931 The instructions for the Safety CPU Unit are described. When programming, use this manual together with the NX-series Safety Control Unit User’s Manual (Cat. No. Z930). 21 MEMO 22 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. Note: Do not use this document to operate the Unit. OMRON Corporation Industrial Automation Company Authorized Distributor: Tokyo, JAPAN Contact: www.ia.omron.com Regional Headquarters OMRON EUROPE B.V. Wegalaan 67-69, 2132 JD Hoofddorp The Netherlands Tel: (31)2356-81-300/Fax: (31)2356-81-388 OMRON ELECTRONICS LLC 2895 Greenspoint Parkway, Suite 200 Hoffman Estates, IL 60169 U.S.A Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 OMRON ASIA PACIFIC PTE. LTD. No. 438A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore 119967 Tel: (65) 6835-3011/Fax: (65) 6835-2711 OMRON (CHINA) CO., LTD. Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 200120, China Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 © OMRON Corporation 2014 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. CSM_4_1_0615 Cat. No. R183-E1-01 1214 (1214)