E3X-DA-S/MDA

Digital Fiber Amplifier Unit
E3X-DA-S/MDA
CSM_E3X-DA-S_MDA_DS_E_15_2
Advanced Fiber Amplifier Units
• Features a Power Tuning function that optimizes light reception at
the press of a button.
• APC circuits to suppress LED aging degradation used with 4element LEDs.
• 2-channel models achieve the thinnest* profile in the industry, at
only 5 mm per channel.
• 2-channel models also offer AND/OR control output.
• The E3X-MDA0 with two channels supports an EtherCAT Sensor
Communications Unit or CompoNet Sensor Communications Unit.
* (Based on July 2012 OMRON investigation.)
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Be sure to read Safety Precautions on
page 15.
Features
Models available for a wide variety of applications at manufacturing sites
Industry Leading Two Amplifiers Loaded in a Small Body
. . . . 2-channel models
Two amplifiers are loaded in a 10 mm-wide body.
Space usability can be approximately doubled.
In addition, approximately 40% of the energy can be
saved.
(compared to the value per channel of the former
model)
Checking LCD substrates seating and alignment
20mm
10mm
2-channel models
E3X-MDA
High-speed and High-resolution Analog Output Supports Wide Variety of Applications . . . .Advanced Analog
Output Models
Analog Control Output
High-speed and High Resolution
The voltage in the range of 1 to 5 V is output according to the incident
level (digital display). Wide variety of applications is possible including
positioning control or difference detection with multiple levels.
Detection modes can be switched in accordance with applications.
High-speed response of 80 μs (super-high-speed mode) supports the
positioning controls that require high-speed control.
Sheet Displacement
ON/OFF
Analog
1
E3X-DA-S/MDA
Ordering Information
Fiber Amplifier Units
Amplifier Units with Cables (2 m) [Refer to Dimensions on page 17.]
Item
Remote setting, counter, differential operation
Area output, self-diagnosis, differential operation
ATC (Threshold value automatic correction)
Analog output models
Model
NPN output
PNP output
E3X-DA11SE-S 2M E3X-DA41SE-S 2M
E3X-DA11-S 2M
E3X-DA41-S 2M
E3X-DAG11-S 2M
E3X-DAG41-S 2M
E3X-DAB11-S 2M
E3X-DAB41-S 2M
E3X-DAH11-S 2M
E3X-DAH41-S 2M
E3X-DA11RM-S 2M E3X-DA41RM-S 2M
E3X-DA11TW-S 2M E3X-DA41TW-S 2M
E3X-DA11AT-S 2M E3X-DA41AT-S 2M
E3X-DA11AN-S 2M E3X-DA41AN-S 2M
AND/OR output
E3X-MDA11 2M
Appearance
Functions
Single-function models
Standard models
Mark-detecting models
(multiple color light
sources)
Advanced models
--Green LED
Blue LED
Infrared LED
External-input models
Twin-output models
ATC function models
Analog output models
Timer, Response speed change
2-channel models
E3X-MDA41 2M
Amplifier Units with Wire-saving Connectors [Refer to Dimensions on page 18.]
Item
Appearance
Remote setting, counter, differential operation
Area output, self-diagnosis, differential operation
ATC (Threshold value automatic correction)
NPN output
E3X-DA6SE-S
E3X-DA6-S *
E3X-DAG6-S *
E3X-DAB6-S *
E3X-DAH6-S *
E3X-DA6RM-S *
E3X-DA6TW-S *
E3X-DA6AT-S
PNP output
E3X-DA8SE-S
E3X-DA8-S *
E3X-DAG8-S *
E3X-DAB8-S *
E3X-DAH8-S *
E3X-DA8RM-S *
E3X-DA8TW-S *
E3X-DA8AT-S
AND/OR output
E3X-MDA6 *
E3X-MDA8 *
Single-function models
Standard models
Mark-detecting models
(multiple color light
sources)
Advanced models
Model
Functions
---
Green LED
Blue LED
Infrared LED
External-input models
Twin-output models
ATC function models
Timer, Response speed change
2-channel models
* These models allow you to use an E3X-DRT21-S VER.3 Sensor Communications Unit. When using the E3X-DRT21-S VER.3, use an E3X-CN02 Connector without
a Cable for the Wire-saving Connector.
Amplifier Units with Connectors for EtherCAT or CompoNet Sensor Communications Units [Refer to Dimensions on page 19.]
Item
Appearance
Functions
Applicable Sensor
Communications Unit
Model
E3X-ECT
2-channel model
E3X-MDA0
AND/OR output
E3X-CRT
Ratings and Specifications
Control output/input
Type
Light source
Single-function models
Standard models
Markdetecting
models
Advanced
models
E3X-DA@G-S
3X-DA@B-S
E3X-DA@H-S
Twin-output
models
External-input
models
ATC function
models
ON/OFF
output
Input
Analog
output
Power
tuning
Timer
---
---
Functions
InterferDifferenence pretial detecvention
tion
counter
ATC
Red LED
1 ms
50 μs to
4 ms
Only
main
---
---
---
---
---
Green LED
Blue LED
Infrared LED
50 μs to
4 ms
Only
main
---
---
---
---
---
Only
main
(1 line)
Red LED
50 μs to
4 ms
80 μs to
4 ms
130 μs to
4 ms
80 μs to
4 ms
Analog output
2-channel models
Response
time
Red LED
130 μs to
4 ms
Main +
sub
(2 lines)
Only
main
Main +
main
(2 independent
lines)
-----
---
--(1 line)
---
---
---
---
---
---
---
2
E3X-DA-S/MDA
Accessories (Order Separately)
Amplifier Unit Connectors (Required for models for Wire-saving Connectors.)
Note: Protector seals are provided as accessories. [Refer to Dimensions on page 19.]
Item
Cable
length
Appearance
No. of conductors
Model
3
E3X-CN11
4
E3X-CN21
1
E3X-CN12
2
E3X-CN22
Master Connector
2m
Slave Connector
Ordering Precaution for Amplifier Units with Wire-saving Connectors
Amplifier Units and Connectors are sold separately. Refer to the following tables when placing an order.
Fiber Amplifier Unit
Model
NPN output
Single-function models E3X-DA6SE-S
Standard models
E3X-DA6-S
E3X-DAG6-S
Mark-detecting models
(multiple color light
E3X-DAB6-S
sources)
E3X-DAH6-S
Advanced models
2-channel models
Applicable Connector (Order Separately)
Master Connector
Slave Connector
PNP output
E3X-DA8SE-S
E3X-DA8-S
E3X-DAG8-S
+
E3X-CN11
E3X-CN12
E3X-CN21
E3X-CN22
E3X-DAB8-S
E3X-DAH8-S
E3X-DA6TW-S
E3X-DA6RM-S
E3X-DA6AT-S
E3X-MDA6
E3X-DA8TW-S
E3X-DA8RM-S
E3X-DA8AT-S
E3X-MDA8
When Using 5 Amplifier Units
Fiber Amplifier Units (5 Units)
+
1 Master Connector + 4 Slave Connectors
Mobile Console [Refer to Dimensions on page 20.]
Appearance
Model
Remarks
E3X-MC11-SV2
(model number of set)
Mobile Console with Head,
Cable, and AC adapter provided as accessories
E3X-MC11-C1-SV2
Mobile Console
E3X-MC11-H1
Head
E39-Z12-1
Cable (1.5 m)
Note: Use the E3X-MC11-SV2 Mobile Console for the E3X-DA-S/MDA-series Fiber Amplifier Units.
The E3X-MC11-SV2 is an upgraded version of the E3X-MC11-S that is fully interchangeable with the older model.
Mounting Bracket [Refer to E39-L/E39-S/E39-R.]
Appearance
Model
E39-L143
Quantity
1
End Plate [Refer to PFP-@.]
Appearance
Model
PFP-M
Quantity
1
3
E3X-DA-S/MDA
Ratings and Specifications
Refer to pages 17 to 20 for dimensions.
Fiber Amplifier Units
● Single-function, Standard, and Mark-detecting Amplifier Units
Item
Type
Single-function
models
Standard
models
Model
E3X-DA@SE-S
E3X-DA@-S
Mark-detecting models (multiple color light sources)
Green LED
Blue LED
Infrared LED
E3X-DAG@-S
E3X-DAB@-S
E3X-DAH@-S
Infrared LED
Green LED (525 nm) Blue LED (470 nm)
(870nm)
Light source (wavelength)
Red LED (635 nm)
Power supply voltage
Power consumption
12 to 24 VDC ±10%, ripple (p-p) 10% max.
960 mW max. (current consumption: 40 mA max. at power supply voltage of 24 VDC)
Load power supply voltage: 26.4 VDC; NPN/PNP open collector;
load current: 50 mA max.; residual voltage: 1 V max.
No-voltage input
--(contact/non-contact)
Reverse polarity for power supply connection, output short-circuit
Control output
Remote control input
Protection circuits
Super-highspeed mode
High-speed
Remode
sponse
time
Standard mode
High-resolution
mode
Sensitivity setting
Power tuning
Timer function
---
Operate: 48 μs, reset: 50 μs *1, *2
---
Operate/reset: 250 μs
Operate or reset: 1 ms
---
Operate or reset: 4 ms
Teaching or manual method
--Light emission power and reception gain, digital control method
Select from OFF-delay, ON-delay, or one-shot timer.
--1 ms to 5 s (1 to 20 ms set in 1-ms increments, 20 to 200 ms set in 10-ms increments,
200 ms to 1 s set in 100-ms increments, and 1 to 5 s set in 1 s-increments)
Automatic power
High-speed control method for emission current
control (APC)
Zero-reset
--Negative values can be displayed. (Threshold value is shifted.)
Initial reset
Settings can be returned to defaults as required.
Mutual interferPossible for up to 10 Units *3
ence prevention
Operation indicator
Display
Operation indicator (orange), Power Tuning indicator (orange)
(orange)
incident level +
Digital display
Select from incident level + threshold or other 6 patterns
threshold
Display orientation
--Switching between normal/reversed display is possible.
Ambient illumination
Incandescent lamp: 10,000 lux max.
Sunlight:
20,000 lux max.
(Receiver side)
Functions
Ambient temperature range
Ambient humidity range
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Degree of protection
Connection method
Weight (packed state)
Case
Materials
Cover
Accessories
Operating: Groups of 1 to 2 Amplifiers: −25°C to 55°C
Groups of 3 to 10 Amplifiers: −25°C to 50°C
Groups of 11 to 16 Amplifiers: −25°C to 45°C
Storage: −30°C to 70°C (with no icing or condensation)
Operating and storage: 35% to 85% (with no condensation)
20 MΩ min. (at 500 VDC)
1,000 VAC at 50/60 Hz for 1 minute
Destruction: 10 to 55 Hz with a 1.5-mm double amplitude for 2 hrs each in X, Y and Z directions
Destruction: 500 m/s2, for 3 times each in X, Y and Z directions
IEC 60529 IP50 (with Protective Cover attached)
Pre-wired or amplifier unit connector
Pre-wired model: Approx. 100 g, Amplifier unit connector model: Approx. 55 g
Polybutylene terephthalate (PBT)
Polycarbonate (PC)
Instruction manual
*1. Communications are disabled if the detection mode is selected during super-high-speed mode, and the communications functions for mutual interference
prevention and the Mobile Console will not function.
*2. PNP output is as follows: Operate: 53 μs, reset: 55 μs.
*3. Mutual interference prevention can be used for only up to 6 Units if power tuning is enabled.
4
E3X-DA-S/MDA
● Advanced and 2-channel Amplifier Units
Advanced models
Type External input
models
Model
Item
Light source
(wavelength)
Power supply voltage
Power consumption
ON/OFF output
Twin output
models
E3X-DA@RM-S E3X-DA@TW-S E3X-DA@AT-S
Analog output models
E3X-DA@AN-S
Red LED (635 nm)
12 to 24 VDC ±10%, ripple (p-p) 10% max.
1,080 mW max. (current consumption: 45 mA max. at power supply voltage of 24 VDC)
Supplied from the
connector through
the Sensor
Communications
Unit
Load power supply voltage: 26.4 VDC; NPN/PNP open collector;
load current: 50 mA max.; residual voltage: 1 V max.
Cont
rol
outp
ut
Analog output
ATC function
models
2-channel models
Model for Sensor
Standard
Communications
models
Unit *1
E3X-MDA@
E3X-MDA0
(@: 11/41/6/8)
---
Control output
Voltage output: 1 to 5 VDC
(Connection load 10 kΩ min.)
Temperature characteristics
0.3%F.S./°C
Response speed/repeat accuracy
Super-high-speed mode:
80 μs/1.5%F.S.
High-speed mode: 250 μs/1.5%F.S.
Standard mode:
1 ms/1%F.S.
High-resolution mode:
4 ms/0.75%F.S.
---
No-voltage
input (contact/
--transistor) *2
Protection circuits
Reverse polarity for power supply connection, output short-circuit
Operate: 48 μs, Operate or
Operate or
Super-highOperate or reset:
Operate or reset:
--reset:
reset:
reset:
speed mode
80 μs *3
130 μs *3, *6
*3, *4, *5
*3
*3
50
μs
80
μs
130
μs
Resp
Operate or reset: 450 μs
onse High-speed mode Operate or reset: 250 μs
time Standard mode Operate or reset: 1ms
High-resolution
Operate or reset: 4ms
mode
Sensitivity setting
Teaching or manual method
Power tuning
Light emission power and reception gain, digital control method
Switchable between single edge and double edge
detection mode Single edge: Can be set to 250 μs,
Differential
500 μs, 1 ms, 10 ms, or 100 ms.
--detection
Double edge: Can be set to 500 μs, 1 ms, 2 ms, 20
ms, or 200 ms.
Select from OFF-delay, ON-delay, or one-shot timer.
Timer function
1 ms to 5 s (1 to 20 ms set in 1-ms increments, 20 to 200 ms set in 10-ms increments, 200 ms to 1 s set in 100-ms
increments, and 1 to 5 s set in 1 s-increments)
Func Automatic power High-speed control method for emission current
tions control (APC)
Zero-reset
Negative values can be displayed. (Threshold value is shifted.)
Initial reset
Settings can be returned to defaults as required.
Mutual interference
Possible for up to 9 Units (18
Possible for up to 10 Units *7
prevention
channels) *8
Switchable
between up
counter and
Counter
--down counter.
Set count:
0 to 9,999,999
Remote control input
*1.This model allows you to use an E3X-ECT EtherCAT Sensor Communications Unit or E3X-CRT CompoNet Sensor Communications Unit.
*2.Input Specifications
NPN
PNP
Contact input (relay or switch)
ON: Shorted to 0 V (sourcing current: 1 mA max.).
OFF: Open or shorted to Vcc.
ON: Shorted to Vcc (sinking current: 3 mA max.).
OFF: Open or shorted to 0 V.
Non-contact input (transistor)
ON: 1.5 V max. (sourcing current: 1 mA max.)
OFF: Vcc - 1.5 V to Vcc (leakage current: 0.1 mA max.)
ON: Vcc - 1.5 V to Vcc (sinking current: 3 mA max.)
OFF: 1.5 V max. (leakage current: 0.1 mA max.)
*3.Communications are disabled if the detection mode is selected during super-high-speed mode, and the communications functions for mutual interference prevention
and the Mobile Console will not function.
*4.PNP output is as follows: Operate: 53 μs, reset: 55 μs.
*5.When counter is enabled: 80 μs for operate and reset respectively.
*6.When differential output is selected for the output setting, the second channel output is 200 μs for operation and reset respectively.
*7.Mutual interference prevention can be used for only up to 6 Units if power tuning is enabled.
*8.Mutual interference prevention can be used for up to 5 Units (10 channels) if power tuning is enabled.
5
E3X-DA-S/MDA
Type
Model
E3X-DA@RM-S
Item
Functions I/O setting
Display
Digital display
Display orientation
Ambient illumination
(Receiver side)
Ambient temperature
range
Ambient humidity
range
Insulation resistance
Dielectric strength
Advanced models
Twin-output
ATC function
models
models
External input
models
E3X-DA@TW-S
E3X-DA@AT-S
Analog output
models
E3X-DA@AN-S
External input
Output setting
Output setting
Analog output
setting (Select
(Select from
(Select from
setting (offset
from teaching,
channel 2
channel 2 output,
voltage
power tuning, zero output, area
area output, selfreset, light OFF, or output, or selfdiagnosis output, or adjustable)
counter reset.)
diagnosis.)
ATC error output)
Operation
Operation
indicator
Operation indicator for channel 1
indicator
(orange), Power (orange), Operation indicator for
(orange),
Tuning indicator channel 2 (orange)
Power Tuning
(orange)
indicator (orange)
Select from
incident level +
Select from incident level + threshold or other 6
threshold or
patterns
other 7 patterns
Switching between normal/reversed display is possible.
Incandescent lamp: 10,000 lux max.
Sunlight:
20,000 lux max.
Operating: Groups of 1 to 2 Amplifiers: −25°C to 55°C
Groups of 3 to 10 Amplifiers: −25°C to 50°C
Groups of 11 to 16 Amplifiers: −25°C to 45°C *9
Storage: −30°C to 70°C (with no icing or condensation)
2-channel models
Standard
Model for Sensor
models
Communications Unit
E3X-MDA@
E3X-MDA0
(@: 11/41/6/8)
Output setting
(Select from channel 2 output, AND, OR,
leading edge sync, falling edge sync, or
differential output)
Operation indicator for channel 1 (orange),
Operation indicator for channel 2 (orange)
Select from incident level for channel 1 +
incident level for channel 2 or other 7
patterns
Operating and storage: 35% to 85% (with no condensation)
20 MΩ min. (at 500 VDC)
1,000 VAC at 50/60 Hz for 1 minute
Vibration resistance
(Destruction)
10 to 55 Hz with a 1.5-mm double amplitude for 2 hrs each in X, Y and Z directions
Shock resistance
(Destruction)
500 m/s2, for 3 times each in X, Y and Z directions
Degree of protection
IEC 60529 IP50 (with Protective Cover attached)
Connection method
Pre-wired or amplifier unit connector
Weight (packed state)
Case
Materials
Cover
Accessories
Pre-wired model: Approx. 100 g, Amplifier unit connector model: Approx. 55 g
Polybutylene terephthalate (PBT)
Polycarbonate (PC)
Instruction manual
10 to 150 Hz with a 0.7mm double amplitude
for 80 min each in X, Y,
and Z directions
150 m/s2 for 3 times
each in X, Y, and Z
directions
Connector for Sensor
Communications Unit
Approx. 55 g
*9. The following temperature ranges apply for operation when an E3X-ECT or E3X-CRT Sensor Communications Unit is used with the E3X-MDA0: Groups of 1 or 2
Amplifier Units: 0 to 55°C, Groups of 3 to 10 Amplifier Units: 0 to 50°C, Groups of 11 to 16 Amplifier Units: 0 to 45°C, Groups of 17 to 30 Amplifier Units (with the
E3X-ECT): 0 to 40°C.
Amplifier Unit Connectors
Item
Model
Mobile Console
E3X-CN11/21/22
E3X-CN12
Rated current
2.5 A
Rated voltage
50 V
Contact resistance
20 mΩ max. (20 mVDC max., 100 mA max.)
(The figure is for connection to the Fiber Amplifier Unit and the adjacent
Connector. It does not include the conductor resistance of the cable.)
No. of insertions
Mater Housing
ials
Contacts
Weight
(packed state)
Item
Model
E3X-MC11-SV2
Applicable
Fiber Amplifier
Units
E3X-DA-S
E3X-MDA
E3C-LDA
E2C-EDA
Power supply
voltage
Charged with AC adapter
Destruction: 50 times
(The figure for the number of insertions is for connection to the Fiber
Amplifier Unit and the adjacent Connector.)
Connection
method
Connected via adapter
Polybutylene terephthalate (PBT)
Weight (packed
state)
Approx. 580 g (Console
only: 120 g)
Phosphor bronze/gold-plated nickel
Approx. 55 g
Approx. 25 g
Refer to Instruction Manual provided with
the Mobile Console for details.
6
E3X-DA-S/MDA
Sensing Distance
● Single-function, Standard, Advanced, and 2-channel Amplifier Units
Threaded Models
(Unit: mm))
E3X-DA@-S
Sensing
method
Sensing direction
Size
Right-angle
Throughbeam
M4
Straight
M3
Right-angle
M4
M6
Reflective
M3
M4
Straight
M6
E3X-MDA@
Model
E32-T11N 2M
E32-LT11N 2M
E32-T11R 2M
E32-LT11 2M
E32-LT11R 2M
E32-C31N 2M
E32-C21N 2M
E32-D21N 2M
E32-C11N 2M
E32-LD11N 2M
E32-D21R 2M
E32-C31 2M
E32-C31M 1M
E32-D211R 2M
E32-D11R 2M
E32-CC200 2M
E32-LD11 2M
E32-LD11R 2M
700
2,300
700
2,700
2,300
40
75
300
280
300
50
530
1,750
530
2,050
1,750
25
65
170
170
170
30
120
75
50
22
75
50
300
500
305
300
30
170
300
180
170
20
120
200
125
120
8
50
90
55
50
30
170
300
175
170
Standard
mode
Highspeed
mode
SuperHighhighresolution
speed
mode
mode
140
450
460
1,500
140
450
540
1,750
460
1,500
7
24
20
50
50
170
50
160
50
170
8
30
Highresolution
mode
350
1,150
350
1,350
1,150
16
45
120
110
120
20
230
750
230
890
750
10
30
80
70
80
14
Superhighspeed
mode
140
460
140
540
460
7
20
50
50
50
8
50
30
22
22
120
210
125
120
14
80
140
85
80
8
50
90
55
50
Standard
mode
Highspeed
mode
350
1,150
350
1,350
1,150
16
45
120
110
120
22
Cylindrical Models
E3X-DA@-S
Sensing
method
Size
Sensing
direction
Throughbeam
1 dia.
1.5 dia.
3 dia.
Reflective
Top-view
Side-view
1.5 dia.
1.5 dia. + 0.5 dia.
Top-view
3 dia.
3 dia. + 0.8 dia.
Model
E32-T223R 2M
E32-T22B 2M
E32-T12R 2M
E32-T14LR 2M
E32-D22B 2M
E32-D43M 1M
E32-D22R 2M
E32-D221B 2M
E32-D32L 2M
E32-D33 2M
Highresolution
mode
160
240
700
270
50
10
50
110
250
25
Standard
mode
E3X-MDA@
Highspeed
mode
130
200
530
210
30
6
30
70
150
16
75
110
350
130
20
4
20
45
100
10
SuperHighhighresolution
speed
mode
mode
30
110
45
150
140
450
50
170
8
30
2
6
8
30
20
70
45
150
4
16
Standard
mode
Highspeed
mode
85
110
350
130
22
4
22
50
100
10
55
70
230
85
14
2.5
14
30
65
6
Superhighspeed
mode
30
45
140
50
8
2
8
20
45
4
Flat Models
E3X-DA@-S
Sensing
method
Throughbeam
Reflective
Sensing direction
Top-view
Side-view
Flat-view
Top-view
Side-view
Flat-view
Model
E32-T15XR 2M
E32-T15YR 2M
E32-T15ZR 2M
E32-D15XR 2M
E32-D15YR 2M
E32-D15ZR 2M
Highresolution
mode
Standard
mode
E3X-MDA@
350
230
Superhighspeed
mode
140
50
170
130
85
50
120
50
170
120
80
50
26
12
40
29
19
12
Highspeed
mode
700
530
350
270
210
130
300
170
70
40
SuperHighhighresolution
speed
mode
mode
140
450
Standard
mode
Highspeed
mode
Note: The super-high-speed mode cannot be used with the E3X-MDA0.
7
E3X-DA-S/MDA
Sleeve Models
E3X-DA@-S
Sensing
method
Sensing direction
E32-T24R 2M
E32-T24E 2M
E32-T21-S1 2M
E32-T33 1M
E32-TC200BR 2M
E32-D24R 2M
E32-D24-S2 2M
E32-D43M 1M
E32-D331 2M
E32-D33 2M
E32-D32-S1 0.5M
E32-D31-S1 0.5M
E32-DC200F4R 2M
E32-D22-S1 2M
E32-D21-S3 2M
E32-DC200BR 2M
E32-D25-S3 2M
Side-view
Throughbeam
Model
Top-view
Side-view
Reflective
Top-view
Highresolution
mode
Standard
mode
E3X-MDA@
Highspeed
mode
25
75
85
25
350
10
23
4
2
10
SuperHighhighresolution
speed
mode
mode
10
35
30
100
34
120
10
35
140
450
4
15
7
26
2
6
0.8
3
4
16
60
160
180
53
700
26
40
10
5
25
50
130
150
44
530
15
26
6
3
16
21
13
9
3
14
50
30
20
8
30
85
55
36
15
56
300
85
170
55
120
36
50
15
170
56
18
45
57
18
230
6
15
2.5
1.3
6
Superhighspeed
mode
10
30
34
10
140
4
7
2
0.8
4
9
6
3
22
14
8
36
24
15
120
36
80
24
50
15
Standard
mode
27
70
85
28
350
10
23
4
2
10
Highspeed
mode
Small-spot, Reflective
E3X-DA@-S
Type
spot diameter
Center
distance
(mm)
Variable spot
0.1 to 0.6 dia.
0.3 to 1.6 dia.
6 to 5
10 to 30
Parallel light
4 dia.
0 to 20
Integrated lens
0.1 dia.
0.1 dia.
5
0.5 dia.
Small-spot
7
0.2 dia.
0.5 dia.
3 dia.
17
50
Model
E32-C42 1M + E39-F3A
E32-C42 1M + E39-F17
E32-C31 2M + E39-F3C
E32-C31N 2M + E39-F3C
E32-C42S 1M
E32-C41 1M + E39-F3A-5
E32-C31 2M + E39-F3A-5
E32-C31N 2M + E39-F3A-5
E32-C41 1M + E39-F3B
E32-C31 2M + E39-F3B
E32-C31N 2M + E39-F3B
E32-CC200 2M + E39-F18
E32-C11N 2M + E39-F18
E3X-MDA@
SuperSuperHighHighStandard
Standard
highhighresolution
speed
mode
mode
speed
speed
mode
mode
mode
mode
Spot diameter of 0.1 to 0.6 mm at 6 to 15 mm. Spot diameter of 0.1 to 0.6 mm at 6 to 15 mm.
Spot diameter of 0.3 to 1.6 mm at 10 to 30 mm. Spot diameter of 0.3 to 1.6 mm at 10 to 30 mm.
Highresolution
mode
Highspeed
mode
Spot diameter of 4 mm max. at 0 to 20 mm.
Spot diameter of 4 mm max. at 0 to 20 mm.
Spot diameter of 0.1 mm at 5 mm.
Spot diameter of 0.1 mm at 7 mm.
Spot diameter of 0.1 mm at 5 mm.
Spot diameter of 0.1 mm at 7 mm.
Spot diameter of 0.5 mm at 7 mm.
Spot diameter of 0.5 mm at 7 mm.
Spot diameter of 0.2 mm at 17 mm.
Spot diameter of 0.2 mm at 17 mm.
Spot diameter of 0.5 mm at 17 mm.
Spot diameter of 0.5 mm at 17 mm.
Spot diameter of 3 mm at 50 mm.
Spot diameter of 3 mm at 50 mm.
Note: The super-high-speed mode cannot be used with the E3X-MDA0.
8
E3X-DA-S/MDA
High-power Beam
E3X-DA@-S
Type
Through-beam
Integrated lens
Sensing
direction
Aperture
angle
Right-angle
15 °
10 °
Top-view
Side-view
Right-angle
Top-view
Side-view
Top-view
Side-view
Throughbeam models
with lenses
Top-view
Side-view
Top-view
Side-view
Top-view
Side-view
Top-view
15 °
30 °
12 °
6°
12 °
6°
60 °
12 °
6°
60 °
12 °
6°
60 °
12 °
6°
60 °
12 °
6°
60 °
12 °
6°
Model
E32-LT11N 2M
E32-T17L 10M
E32-LT11 2M
E32-LT11R 2M
E32-T14 2M
E32-T11N 2M + E39-F1
E32-T11N 2M + E39-F16
E32-T11R 2M + E39-F1
E32-T11R 2M + E39-F16
E32-T11R 2M + E39-F2
E32-T11 2M + E39-F1
E32-T11 2M + E39-F16
E32-T11 2M + E39-F2
E32-T51R 2M + E39-F1
E32-T51R 2M + E39-F16
E32-T51R 2M + E39-F2
E32-T81R-S 2M + E39-F1
E32-T81R-S 2M + E39-F16
E32-T81R-S 2M + E39-F2
E32-T61-S 2M + E39-F1
E32-T61-S 2M + E39-F16
E32-T61-S 2M + E39-F2
E32-T51 2M + E39-F1-33
E32-T51 2M + E39-F16
Highresolution
mode
Standard
mode
2,300
1,750
20,000 *1 20,000 *1
2,700
2,050
2,300
1,750
4,000 *2
3,400
4,000 *2
3,700
4,000 *2
4,000 *2
4,000 *2
3,700
4,000 *2
4,000 *2
520
400
4,000 *2
3,600
4,000 *2
4,000 *2
820
660
3,900
2,900
4,000 *2
4,000 *2
500
380
4,000 *2
3,200
4,000 *2
4,000 *2
540
410
4,000
3,400
4,000 *2
4,000 *2
600
450
4,000 *2
4,000 *2
4,000 *2
4,000 *2
E3X-MDA@
Highspeed
mode
1,150
10,000
1,350
1,150
2,250
2,400
4,000 *2
2,400
4,000 *2
250
2,300
4,000 *2
430
1,900
3,500
250
2,100
3,700
270
2,200
3,700
300
3,500
4,000 *2
SuperHighhighresolution
speed
mode
mode
460
1,500
4,000
13,000
540
1,750
460
1,500
900
2,900
970
3,100
1,700
4,000 *2
970
3,100
1,700
4,000 *2
100
330
930
3,000
2,200
4,000 *2
160
530
780
2,500
1,400
4,000 *2
100
320
840
2,700
1,500
4,000 *2
100
350
900
3,000
1,500
4,000 *2
120
390
1,400
4,000 *2
2,500
4,000 *2
Standard
mode
1,150
10,000
1,350
1,150
2,200
2,400
4,000 *2
2,400
4,000 *2
260
2,300
4,000 *2
430
1,900
3,500
250
2,100
3,700
270
2,200
3,700
300
3,500
4,000 *2
Highspeed
mode
750
6,500
890
750
1,450
1,600
2,900
1,600
2,900
170
1,500
3,700
280
1,300
2,300
160
1,380
2,500
170
1,450
2,500
200
2,300
4,000 *2
Superhighspeed
mode
460
4,000
540
460
900
970
1,700
970
1,700
100
930
2,200
160
780
1,400
100
840
1,500
100
900
1,500
120
1,400
2,500
Reflective
Top-view
4°
E32-D16 2M
40 to 1,000 40 to 700 40 to 450 40 to 240 40 to 600 40 to 490 40 to 300 40 to 240
Integrated lens
*1. The fiber length is 10 m on each side, so the sensing distance is given as 20,000 mm.
*2. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Narrow View
E3X-DA@-S
Sensing
method
Sensing direction
Aperture
angle
1.5 °
Throughbeam
Side-view
3.4 °
4°
Model
E32-A03 2M
E32-A03-1 2M
E32-A04 2M
E32-T24SR 2M
E32-T24S 2M
E32-T22S 2M
Highresolution
mode
Standard
mode
E3X-MDA@
Highspeed
mode
Superhighspeed
mode
Highresolution
mode
Standard
mode
Highspeed
mode
Superhighspeed
mode
1,150
890
600
250
750
580
380
250
460
1,480
1,750
2,500
340
1,100
1,300
1,900
225
730
870
1,250
100
290
350
500
300
920
1,100
1,600
220
730
870
1,250
145
480
580
830
100
290
350
500
Detection without Background Interference
E3X-DA@-S
Sensing
method
Limitedreflective
Sensing direction
Model
Highresolution
mode
E32-L16-N 2M
E32-L24S 2M
E32-L25L 2M
Flat-view
Side-view
Standard
mode
E3X-MDA@
Highspeed
mode
0 to 15
0 to 4
5.4 to 9 (center 7.2)
Superhighspeed
mode
0 to 12
Highresolution
mode
Standard
mode
Highspeed
mode
0 to 15
0 to 4
5.4 to 9 (center 7.2)
Superhighspeed
mode
0 to 12
Transparent Object Detection (Retro-reflective)
E3X-DA@-S
Sensing
method
Retroreflective
Feature
Size
Film detection
M3
Square
Threaded models
−
M6
Hex-shaped
M6
Model
E32-C31 2M + E39-F3R
+ E39-RP37
E32-R16 2M
E32-R21 2M
E32-LR11NP 2M
+ E39-RP1
Highresolution
mode
250
Standard
mode
E3X-MDA@
Highspeed
mode
150
100
Superhighspeed
mode
45
Highresolution
mode
150
150 to 1500
10 to 250
630
600
Standard
mode
Highspeed
mode
100
Superhighspeed
mode
65
45
330
275
150 to 1500
10 to 250
500
275
600
500
Note: The super-high-speed mode cannot be used with the E3X-MDA0.
9
E3X-DA-S/MDA
Transparent Object Detection (Limited-reflective)
E3X-DA@-S
Sensing
method
Sensing
direction
Feature
Limitedreflective
Small size
Standard
Glass substrate
alignment, 70 °C
Standard/
long-distance
Side view form
Glass substrate
mapping, 70 °C
Model
Highresolution
mode
E32- L24S 2M
E32-L16-N 2M
Standard
mode
E3X-MDA@
Highspeed
mode
0 to 4
0 to 15
Superhighspeed
mode
Highresolution
mode
Standard
mode
Highspeed
mode
0 to 4
0 to 15
0 to 12
Superhighspeed
mode
0 to 12
Flat-view E32-A08 2M
10 to 20
−
10 to 20
−
E32-A12 2M
12 to 30
−
12 to 30
−
Side-view E32-L25L 2M
5.4 to 9 (center 7.2)
Top-view E32-A09 2M
15 to 38
5.4 to 9 (center 7.2)
−
−
15 to 38
Chemical-resistant, Oil-resistant
E3X-DA@-S
Sensing
method
Sensing
direction
Type
Oil-resistant
Throughbeam
Chemical/
oil-resistant
Model
Right-angle E32-T11NF 2M
E32-T12F 2M
Top-view
E32-T11F 2M
Side-view E32-T14F 2M
Highresolution
mode
4,000 *
4,000 *
2,500
500
Chemical/oil-resistant
Top-view E32-T51F 2M
1,800
at 150 °C
Chemical/oil-resistant
E32-D12F 2M
160
Top-view
Reflective
Chemical-resistant cable
E32-D11U 2M
300
* The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Standard
mode
E3X-MDA@
Highspeed
mode
SuperHighhighresolution
speed
mode
mode
1,100
3,600
800
2,600
520
1,600
100
320
4,000 *
3,000
2,000
400
2,800
2,000
1,300
250
1,400
900
350
95
170
65
120
30
50
2,800
2,000
1,300
250
1,800
1,300
850
160
Superhighspeed
mode
1,100
800
520
100
1,190
920
600
350
95
170
70
125
45
80
30
50
Standard
mode
Highspeed
mode
Bending-resistant
E3X-DA@-S
Sensing
method
Size
1.5 dia.
M3
M4
Square
1.5 dia.
M3
3 dia.
M4
M6
Square
Throughbeam
Reflective
Model
E32-T22B 2M
E32-T21 2M
E32-T11 2M
E32-T25XB 2M
E32-D22B 2M
E32-D21 2M
E32-D221B 2M
E32-D21B 2M
E32-D11 2M
E32-D25XB 2M
Highresolution
mode
Standard
mode
E3X-MDA@
Highspeed
mode
Superhighspeed
mode
Highresolution
mode
Standard
mode
Highspeed
mode
Superhighspeed
mode
240
200
110
45
150
110
70
45
900
180
680
150
450
85
180
35
580
125
450
95
300
60
180
35
50
30
20
8
30
22
14
8
110
70
45
20
70
50
30
20
300
85
170
50
120
30
50
15
170
50
125
35
80
23
50
15
E3X-MDA@
SuperHighHighStandard
highresolution
speed
mode
speed
mode
mode
mode
110
360
280
180
200
650
500
330
70
230
180
120
120
390
300
200
40
130
95
60
72
230
165
110
27
90
63
40
10 to 20
−
20 to 30
−
Superhighspeed
mode
110
200
70
120
40
72
27
−
−
Heat-resistant
E3X-DA@-S
Sensing
method
Throughbeam
Reflective
Heat-resistant temperature
100 °C
150 °C
200 °C
350 °C
100 °C
150 °C
200 °C
300 °C
350 °C
400 °C
Model
E32-T51R 2M
E32-T51 2M
E32-T81R-S 2M
E32-T61-S 2M
E32-D51R 2M
E32-D51 2M
E32-D81R-S 2M
E32-A08H2 2M
E32-A09H2 2M
E32-D611-S 2M
E32-D61-S 2M
E32-D73-S 2M
Highresolution
mode
Standard
mode
Highspeed
mode
560
1,000
360
600
240
400
150
425
760
280
450
135
230
90
10 to 20
20 to 30
280
500
180
300
95
160
60
150
90
60
27
90
63
40
27
100
60
40
18
60
40
25
18
Note: The super-high-speed mode cannot be used with the E3X-MDA0.
10
E3X-DA-S/MDA
Area Beam
E3X-DA@-S
Sensing
method
Type
Throughbeam
Area
Reflective
Array
Sensing
width
11 mm
30 mm
11 mm
Model
E32-T16PR 2M
E32-T16JR 2M
E32-T16WR 2M
E32-D36P1 2M
Highresolution
mode
1,100
980
1,700
250
Standard
mode
E3X-MDA@
Highspeed
mode
840
750
1,300
150
560
480
850
100
SuperHighhighresolution
speed
mode
mode
220
730
190
600
340
1,100
45
150
Standard
mode
Highspeed
mode
560
480
860
100
370
320
570
65
Superhighspeed
mode
220
190
340
45
Liquid-level Detection
Sensing method
Tube
diameter
3.2/6.4/9.5
dia.
Tube-mounting
8 to 10 dia.
Feature
Model
Stable residual
E32-A01 5M
quantity detection
Mounting at
E32-L25T 2M
multi levels
No restrictions
Large tubes
E32-D36T 2M
−
−
E32-D82F1 4M
Liquid contact
(heat-resistant
up to 200 °C)
E3X-DA@-S
E3X-MDA@
SuperHighHighhighStandard
resolution
speed
speed
mode
mode
mode
mode
Applicable tube: Transparent tube with a diameter of 3.2,
6.4, or 9.5 mm, Recommended wall thickness: 1 mm
Applicable tube: Transparent tube with a diameter
of 8 to 10 mm, Recommended wall thickness: 1 mm
Applicable tube: Transparent tube
(no restriction on diameter)
Superhighspeed
mode
Applicable tube: Transparent tube with a diameter of 3.2,
6.4, or 9.5 mm, Recommended wall thickness: 1 mm
Applicable tube: Transparent tube with a diameter of
8 to 10 mm, Recommended wall thickness: 1 mm
Applicable tube: Transparent tube
(no restriction on diameter)
Liquid-contact Type
Liquid-contact Type
Highresolution
mode
Standard
mode
Highspeed
mode
Vacuum-resistant
E3X-DA@-S
Sensing
method
Throughbeam
Heat-resistant temperature
Model
E32-T51V 1M
E32-T51V 1M + E39-F1V
E32-T84SV 1M
120 °C
200 °C
Highresolution
mode
260
1,350
630
Standard
mode
E3X-MDA@
Highspeed
mode
200
1,000
480
130
680
320
SuperHighhighresolution
speed
mode
mode
50
170
260
850
130
410
Standard
mode
Highspeed
mode
130
650
310
85
430
200
Superhighspeed
mode
50
260
130
FPD, Semiconductors, and Solar Cells
E3X-DA@-S
Sensing
method
Application
Glass presence detection
Limitedreflective
Glass substrate alignment
70 °C
300 °C
70 °C
Glass substrate mapping
Throughbeam
Operating
temperature
Wafer mapping
300 °C
70 °C
Model
E32-L16-N 2M
E32-A08 2M
E32-A08H2 2M
E32-A12 2M
E32-A09 2M
E32-A09H2 2M
E32-A03 2M
E32-A03-1 2M
E32-A04 2M
E32-T24SR 2M
E32-T24S 2M
Highresolution
mode
E3X-MDA@
0 to 15
Superhighspeed
mode
0 to 12
10 to 20
12 to 30
15 to 38
20 to 30
Standard
mode
Highspeed
mode
0 to 15
Superhighspeed
mode
0 to 12
−
10 to 20
−
−
−
−
12 to 30
15 to 38
20 to 30
−
−
−
Highresolution
mode
Standard
mode
Highspeed
mode
1,150
890
600
250
750
580
380
250
460
1,480
1,750
340
1,100
1,300
225
730
870
100
290
350
300
920
1,100
220
730
870
145
480
580
100
290
350
Note: The super-high-speed mode cannot be used with the E3X-MDA0.
11
E3X-DA-S/MDA
● Mark-detecting Amplifier Units (Different Colors of Light Sources)
Threaded Models
E3X-DAG@-S/DAB@-S
Sensing
method
Sensing direction
Size
Throughbeam
Right-angle
Straight
M4
M3
Reflective
Straight
M6
Model
E32-T11N 2M
E32-T11R 2M
E32-C31 2M
E32-D11R 2M
E32-CC200 2M
Highresolution
mode
Standard
mode
Highspeed
mode
E3X-DAH@-S
Superhighspeed
mode
Highresolution
mode
Standard
mode
Highspeed
mode
Superhighspeed
mode
65
50
35
30
280
190
130
55
7.5
17
32
6
14
25
4
10
16
3.5
8
16
50
120
200
37
90
150
25
60
100
8.5
21
35
Cylindrical Models
E3X-DAG@-S/DAB@-S
Sensing
method
Throughbeam
Reflective
Sensing
direction
Size
Top-view
Side-view
Top-view
3 dia.
3 dia.
Model
E32-T12R 2M
E32-T14LR 2M
E32-D32L 2M
Highresolution
mode
Standard
mode
65
25
15
50
20
12
Highspeed
mode
35
22
8
E3X-DAH@-S
SuperHighhighresolution
speed
mode
mode
30
280
12
100
7.5
100
Standard
mode
190
75
75
Highspeed
mode
130
80
50
Superhighspeed
mode
55
21
17
Flat Models
E3X-DAG@-S/DAB@-S
Sensing
method
Sensing direction
Top-view
Side-view
Flat-view
Top-view
Side-view
Flat-view
Throughbeam
Reflective
Model
E32-T15XR 2M
E32-T15YR 2M
E32-T15ZR 2M
E32-D15XR 2M
E32-D15YR 2M
E32-D15ZR 2M
Highresolution
mode
Standard
mode
Highspeed
mode
E3X-DAH@-S
SuperHighhighresolution
speed
mode
mode
30
280
65
50
35
25
20
22
12
17
14
10
8
4.2
3.3
2.2
2.1
190
130
Superhighspeed
mode
55
100
75
80
21
120
90
60
21
28
20
13
5
Standard
mode
Highspeed
mode
Sleeve Models
E3X-DAG@-S/DAB@-S
Sensing
method
Sensing direction
Throughbeam
Reflective
Model
Highresolution
mode
Standard
mode
Highspeed
mode
E3X-DAH@-S
Superhighspeed
mode
Highresolution
mode
Standard
mode
Highspeed
mode
Superhighspeed
mode
Top-view
E32-TC200BR 2M
65
50
35
30
280
190
130
55
Top-view
E32-DC200BR 2M
17
14
10
8
120
90
60
21
High-power Beam
E3X-DAG@-S/DAB@-S
Type
Sensing
direction
Aperture
angle
Through-beam
Integrated lens
Side-view
30 °
Model
E32-T14 2M
Highresolution
mode
320
Standard
mode
260
Highspeed
mode
220
E3X-DAH@-S
Superhighspeed
mode
160
Highresolution
mode
1800
Standard
mode
1200
Highspeed
mode
820
Superhighspeed
mode
360
12
E3X-DA-S/MDA
Output Circuit Diagrams
NPN Output
Operation
mode
Model
E3X-DA11-S
E3X-DA6-S
E3X-DAG11-S
E3X-DAG6-S
E3X-DAB11-S
E3X-DAB6-S
E3X-DAH11-S
E3X-DAH6-S
E3X-DA11SE-S
E3X-DA6SE-S
Light-ON
Operation
selector
Timing charts
Incident light
No incident light
Operation
ON
indicator
OFF
(orange)
ON
Output
transistor
OFF
Load
Operate
(relay)
Reset
Output circuit
LIGHT ON
(L-ON)
Power
tuning
indicator
(orange)
(Between brown and black leads)
Dark-ON
Incident light
No incident light
Operation
ON
indicator
OFF
(orange)
ON
Output
OFF
transistor
Operate
Load
Reset
(relay)
Operation indicator
(orange)
Display
Brown
Black Load
Control output
Photoelectric
Sensor
main
circuit
12 to
24 VDC
Blue
DARK ON
(D-ON)
(Between brown and black leads)
Light-ON
E3X-DA11TW-S
E3X-DA6TW-S
E3X-MDA11
E3X-MDA6
E3X-DA11AT-S
E3X-DA6AT-S
CH1/ Incident light
CH2 No incident light
Operation ON
indicator OFF
(orange)
ON
Output
transistor OFF
Operate
Load
Reset
(relay)
LIGHT ON
(L-ON)
Display
Operation indicator
(orange)
ch 1
Brown
Load
Black
Control
output 1
Photoelectric
Sensor
main
circuit
(Between brown and black leads)
Dark-ON
Operation indicator
(orange) ch 2
CH1/ Incident light
CH2 No incident light
Operation
ON
indicator
OFF
(orange)
ON
Output
transistor
OFF
Operate
Load
(relay)
Reset
Load
Orange
Control
output 2
12 to
24 VDC
Blue
DARK ON
(D-ON)
(Between brown and black leads)
Light-ON
Incident light
No incident light
Operation
ON
indicator
OFF
(orange)
ON
Output
OFF
transistor
Operate
Load
(relay)
Reset
LIGHT ON
(L-ON)
Power
tuning
indicator
(orange)
(Between brown and black leads)
E3X-DA11RM-S
E3X-DA6RM-S
Dark-ON
Operation indicator
(orange)
Display
Incident light
No incident light
Operation
ON
indicator
OFF
(orange)
ON
Output
OFF
transistor
Operate
Load
Reset
(relay)
Brown
Load
Black
Control output
Photoelectric
Sensor
main
circuit
Orange
DARK ON
(D-ON)
External
input
12 to
24 VDC
Blue
(Between brown and black leads)
Incident light
Light-ON
No incident light
Operation
ON
indicator
OFF
(orange)
ON
Output
OFF
transistor
Load
Operate
(relay)
Reset
LIGHT ON
(L-ON)
(Between brown and black leads)
E3X-DA11AN-S
Display
Power
tuning
indicator
(orange)
Incident light
Dark-ON
No incident light
Operation
ON
indicator
OFF
(orange)
Operation indicator
(orange)
Brown
Load
Black
Control output
Analog
Orange
output
models
Photoelectric
Sensor
main
circuit
Load 10kΩmin
Blue
DARK ON
(D-ON)
ON
Output
OFF
transistor
Load
Operate
(relay)
Reset
12 to
24 VDC
(Between brown and black leads)
Note: 1. The ON/OFF regions when areas settings are used with the E3XDA@TW-S are as follows:
LIGHT ON: ON when the incident level is between the thresholds for
channels 1 and 2.
DARK ON: OFF when the incident level is between the thresholds for
channels 1 and 2.
2. Timing Charts for Timer Function Settings (T: Set Time)
ON delay
OFF delay
Incident light
No incident light
L-ON
D-ON
Incident light
ON
OFF
Incident light
No incident light
T
ON
OFF
One-shot
L-ON
T
D-ON
T
ON
OFF
ON
OFF
No incident light
L-ON
T
D-ON
T
ON
OFF
T
3. Control Output (AND, OR, Sync) and Timing Chart for Timer Settings
(T: Set Time)
ON
OFF
ON
CH2
OFF
OUT ON
(AND) OFF
OUT ON
(OR) OFF
OUT ON
(sync) OFF
CH1
ON
OFF
ON
CH2
OFF
ON delay ON
(AND) OFF
OFF delay ON
(AND) OFF
One-shot ON
(AND) OFF
CH1
T
T
T
T
ON
OFF
13
E3X-DA-S/MDA
PNP Output
Model
Operation mode
Timing chart
Operation
selector
Output circuit
Incident light
E3X-DA41-S
E3X-DA8-S
E3X-DAG41-S
E3X-DAG8-S
E3X-DAB41-S
E3X-DAB8-S
E3X-DAH41-S
E3X-DAH8-S
E3X-DA41SE-S
E3X-DA8SE-S
Light-ON
No incident light
Operation
ON
indicator
OFF
(orange)
ON
Output
transistor
Load
(relay)
LIGHT ON
(L-ON)
Operation indicator
(orange)
Display
OFF
Power
tuning
indicator
(orange)
Operate
Reset
(Between blue and black leads)
Incident light
Dark-ON
No incident light
Operation
ON
indicator
OFF
(orange)
ON
Output
transistor
OFF
Load
Operate
(relay)
Reset
Photoelectric
Sensor
main
circuit
DARK ON
(D-ON)
Brown
Control
output
Black
12 to
24 VDC
Load
Blue
(Between blue and black leads)
Light-ON
E3X-DA41TW-S
E3X-DA8TW-S
E3X-MDA41
E3X-MDA8
E3X-DA41AT-S
E3X-DA8AT-S
Incident light
CH1/
CH2 No incident light
Operation
ON
indicator
OFF
(orange)
ON
Output
transistor
Load
(relay)
OFF
LIGHT ON
(L-ON)
Operation indicator
(orange)
ch 1
Display
Operate
Reset
Photoelectric
Sensor
main
circuit
(Between blue and black leads)
Incident light
Dark-ON
Operation indicator
(orange) ch 2
CH1/
CH2 No incident light
Operation
ON
indicator
OFF
(orange)
ON
Output
transistor
Load
(relay)
Brown
Control
output 1
Black
12 to
24 VDC
Control
output 2
Orange
Load
Load
DARK ON
(D-ON)
Blue
OFF
Operate
Reset
(Between blue and black leads)
Incident light
Light-ON
No incident light
Operation
ON
indicator
OFF
(orange)
ON
Output
transistor
OFF
Load
Operate
(relay)
Reset
E3X-DA41RM-S
E3X-DA8RM-S
LIGHT ON
(L-ON)
Display
Power
tuning
indicator
(orange)
(Between blue and black leads)
Incident light
Dark-ON
No incident light
Operation
ON
indicator
OFF
(orange)
Output
transistor
Load
(relay)
ON
Operation indicator
(orange)
Photoelectric
Sensor
main
circuit
Brown
Orange
Black
Blue
External
input
Control
output
12 to
24 VDC
Load
DARK ON
(D-ON)
OFF
Operate
Reset
(Between blue and black leads)
Incident light
Light-ON
No incident light
Operation
ON
indicator
OFF
(orange)
ON
Output
transistor
Load
(relay)
LIGHT ON
(L-ON)
OFF
Power
tuning
indicator
(orange)
Operate
Reset
(Between blue and black leads)
E3X-DA41AN-S
Incident light
Dark-ON
No incident light
Operation
ON
indicator
OFF
(orange)
ON
Output
transistor
Load
(relay)
Display
Operation indicator (orange)
Photoelectric
Sensor
main
circuit
Brown
Analog
Orange output models
12 to
Control
24 VDC
output
Black
Blue
Load
Load 10kΩmin
DARK ON
(D-ON)
OFF
Operate
Reset
(Between blue and black leads)
Note: The ON/OFF regions when areas settings are used with the E3X-DA@TW-S are as follows:
LIGHT ON: ON when the incident level is between the thresholds for channels 1 and 2.
DARK ON: OFF when the incident level is between the thresholds for channels 1 and 2.
14
E3X-DA-S/MDA
Nomenclature
Fiber Amplifier Units
E3X-DA@-S
E3X-DA@RM-S
E3X-DA@AN-S
Main Display (Red)
Incident level, function, etc.
Sub-Display (Green)
Threshold, function settings,
etc.
E3X-DA@TW-S
E3X-DA@AT-S
E3X-MDA@
Operation Keys
Function setting operations
UP
Lock lever
Locks the fiber unit.
DOWN
Main Display (Red)
Incident level, function, etc.
Lock lever
Locks the fiber unit.
MODE
Operation Indicator
(orange)
ON when output is
ON.
OFF when output is
OFF.
Power Tuning Indicator
ON: Power tuning is set.
Operation Selector
Use to switch between Light
ON and Dark ON modes.
Mode Selector
Use to select SET or RUN mode.
Operation indicator for
channel 1 (orange)
ON when output is ON.
OFF when output is OFF.
Sub-Display (Green)
Threshold, function settings,
etc.
Operation Keys
Function setting operations
UP
DOWN
MODE
Channel Selector
Use to switch between channels
Operation indicator for
1 and 2.
channel 2 (orange)
Mode Selector
ON when output is ON.
Use to select SET or RUN mode.
OFF when output is OFF.
Safety Precautions
Refer to Warranty and Limitations of Liability.
WARNING
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
Precautions for Correct Use
Do not use the product in atmospheres or environments that exceed
product ratings.
Fiber Amplifier Unit
Removing Connectors
1. Slide the slave Amplifier Unit(s) for which the Connector is to be
removed away from the rest of the group.
2. After the Amplifier Unit(s) has been separated, press down on the
lever on the Connector and remove it. (Do not attempt to remove
Connectors without separating them from other Amplifier Units
first.)
Press down
Lever
● Designing
Operation after Turning Power ON
The Sensor is ready to detect within 200 ms after the power supply is
turned ON. If the Sensor and load are connected to separate power
supplies, be sure to turn ON the Sensor first.
● Mounting
Connecting and Disconnecting Wire-saving Connectors
Remove
Adding and Removing Fiber Amplifier Units
Adding Fiber Amplifier Units
1. Mount the Amplifier Units one at a time onto the DIN track.
Mounting Connectors
1. Insert the Master or Slave Connector into the Amplifier Unit until it
clicks into place.
2. Slide the Amplifier Units together, line up the clips, and press the
Amplifier Units together until they click into place.
Insert
2. Attach the protector seals (provided as accessories) to the sides of
master and slave connectors that are not connected.
Seal
Seal
Note: Attach the seals to the sides with grooves.
Click into place
Removing Fiber Amplifier Units
Slide Amplifier Units away from each other, and remove from the DIN
track one at a time. (Do not attempt to remove Amplifier Units from the
DIN track without separating them first.)
Note: 1. The specifications for ambient temperature will vary according to the
number of Amplifier Units used together. For details, refer to Ratings
and Specifications.
2. Always turn OFF the power supply before joining or separating
Amplifier Units.
15
E3X-DA-S/MDA
Mounting the End Plate (PFP-M)
Fiber Units That Cannot Be Free-Cut (with Sleeves)
An End Plate should be used if there is a possibility of the Amplifier
Unit moving, e.g., due to vibration. If a Mobile Console is going to be
mounted, connect the End Plate in the direction shown in the following
diagram.
9 mm
13 mm
2. Disconnecting Fiber Units
Remove the protective cover and raise the lock lever to pull out the
fiber units.
End Plate
Mounting the Mobile Console Head
Leave a gap of at least 20 mm between the nearest Amplifier Unit and
the Mobile Console head.
Protective cover
20 mm
Locked
Fiber Unit Connection
The E3X Amplifier Unit has a lock button for easy connection of the
Fiber Unit. Connect or disconnect the fiber units using the following
procedures:
1. Connection
Open the protective cover, insert the fiber units according to the fiber
unit insertion marks on the side of the Amplifier Unit, and lower the
lock lever.
Unlocked
Note: 1. To maintain the fiber unit properties, confirm that the lock is released
before removing the fiber units.
2. Be sure to lock or unlock the lock button within an ambient
temperature range between −10°C and 40°C.
● Adjusting
Mutual Interference Protection Function
There may be some instability in the digital display values due to light
from other sensors. If this occurs, decrease the sensitivity (i.e.,
decrease the power or increase the threshold) to perform stable
detection.
EEPROM Writing Error
Lock button
Protective cover
Locked
Unlocked
Insertion position
If the data is not written to the EEPROM correctly due to a power
failure or static-electric noise, initialize the settings with the keys on
the Amplifier Unit. ERR/EEP will flash on the display when a writing
error has occurred.
Optical Communications
Fiber unit insertion mark
Several Amplifier Units can be slid together and used in groups. Do
not, however, slide the Amplifier Units or attempt to remove any of the
Amplifier Units during operation.
Fiber unit
9 mm
Note: If one of the fibers from the Fiber Unit is labeled as the Emitter fiber, such as
with a Coaxial Sensor, insert that fiber into the Emitter section. Refer to
Dimensions for the Fiber Unit to see if there is an Emitter fiber label.
Fiber Units with E39-F9 Attachment
● Others
Protective Cover
Always keep the protective cover in place when using the Amplifier
Unit.
Mobile Console
Use the E3X-MC11-SV2 Mobile Console for the E3X-DA-S-series
Amplifier Units.
Fiber Unit
9 mm
13 mm
16
E3X-DA-S/MDA
(Unit: mm)
Dimensions
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
Fiber Amplifier Units
Amplifier Units with Cables
E3X-DA11-S
E3X-DA41-S
E3X-DAG11-S
15.6
E3X-DAG41-S
10
E3X-DAB11-S
E3X-DAB41-S
Operation indicator
E3X-DAH11-S
E3X-DAH41-S
4.3
E3X-DA11RM-S
E3X-MDA@ only
E3X-DA41RM-S
101.45
E3X-DA11TW-S
ch2
E3X-DA41TW-S
E3X-DA11SE-S
4.5
32
E3X-DA41SE-S
7
(16.5)
E3X-DA11AT-S
4.5
E3X-DA41AT-S
5.65
3.4
E3X-DA11AN-S
ch1
Four,
2.4
dia.
18.7
E3X-DA41AN-S
E3X-DA@-S
E3X-MDA11
(E3X-MDA@)
E3X-MDA41
Area of digital indication
Round ( ): Power tuning indicator
Oblong ( ): Operation indicator for channel 2
35.25
6.3
Main display
Sub-display
DIN track mounting
141.1
180°
Vinyl-insulated round cable
Standard length: 2 m*
12.5
Hole for optical communications
(36.2)
Multiple connection diagram
(21.3)
70
L
Center of DIN track
End Plate
(sold separately)
PFP-M
DIN track
(sold separately)
PFP-@N
10
Fiber Attachment mounted (E39-F9)
* Cable Specifications
10
10
The number of
expansion
L (mm)
1
10
2
20
3
30
4
40
5
50
6
60
E3X-DA11-S
-DA41-S
-DAG11-S
-DAG41-S
-DAB11-S
-DAB41-S
-DAH11-S
-DAH41-S
4-dia., 3-conductor (Conductor cross section: 0.2 mm2,
insulator diameter: 1.1 mm)
E3X-DA11TW-S
-DA41TW-S
-DA11RM-S
-DA41RM-S
4-dia., 4-conductor (Conductor cross section: 0.2 mm2,
insulator diameter, 1.1 mm)
7
70
8
80
E3X-MDA11
-MDA41
4-dia., 2-conductor (Conductor cross section: 0.2 mm2,
insulator diameter: 1.1 mm)
9
90
10
100
4.3
With Mounting Bracket Attached
141.1
E3X-MDA@ only
180°
101.45
ch2
Vinyl-insulated round cable
Standard length: 2 m*
4.5
32
7
(16.5)
4.5
12.5
5.65
3.4
ch1
Four, 2.4 dia.
10.3
Two, 3.2 dia.
holes
18.7
Hole for optical communications
4.3
(9.4)
16
70
E3X-DA@-S
(E3X-MDA@)
Mounting Bracket (E39-L143)
SUS304 stainless steel
3.4
Mounting Holes
4.4
Two, M3
16
28.1
16
Note: When using E39-L143 Mounting
Brackets, there will be small gaps
between the Fiber Amplifier Units if
they are mounted side by side.
Fiber Attachment mounted (E39-F9)
17
E3X-DA-S/MDA
Amplifier Units with Wire-saving Connectors
E3X-DA6-S
E3X-DA8-S
E3X-DAG6-S
15.6
E3X-DAG8-S
10
E3X-DAB6-S
E3X-DAB8-S
Operation indicator
E3X-DAH6-S
E3X-DAH8-S
4.3
E3X-DA6RM-S
E3X-MDA@ only
E3X-DA8RM-S
101.45
E3X-DA6TW-S
ch2
E3X-DA8TW-S
4.5
E3X-DA6SE-S
32
E3X-DA8SE-S
7
(16.5)
E3X-DA6AT-S
4.5
E3X-DA8AT-S
5.65
3.4
E3X-MDA6
ch1
Four,
2.4
dia.
18.7
E3X-MDA8
E3X-DA@-S
(E3X-MDA@)
Area of digital indication
Round ( ): Power tuning indicator
Oblong ( ): Operation indicator for channel 2
35.25
6.3
Main display
Sub-display
DIN track mounting
141.1
180°
A dia. *
12.95
Hole for optical communications
(36.2)
Multiple connection diagram
(21.3)
70
L
Center of DIN track
End Plate
(sold separately)
PFP-M
DIN track
(sold separately)
PFP-@N
10
Fiber Attachment mounted (E39-F9)
* Cable Diameters
E3X-CN22 (2 conductors)
E3X-CN21 (4 conductors)
E3X-CN11 (3 conductors)
4.0-mm dia.
E3X-CN12 (1 conductor)
2.6-mm dia.
L (mm)
1
10
2
20
3
30
4
40
5
50
6
60
7
70
8
80
10
4.3
10
The number of
expansion
9
90
10
100
With Mounting Bracket Attached
141.1
E3X-MDA@ only
180°
101.45
ch2
4.5
A dia. *
32
7
(16.5)
4.5
12.95
5.65
3.4
ch1
Four, 2.4 dia.
10.3
Two, 3.2 dia.
holes
18.7
Hole for optical communications
4.3
(9.4)
16
70
E3X-DA@-S
(E3X-MDA@)
Mounting Bracket (E39-L143)
SUS304 stainless steel
3.4
4.4
Mounting Holes
Two, M3
28.1
16
16
Fiber Attachment mounted (E39-F9)
Note: When using E39-L143 Mounting
Brackets, there will be small gaps
between the Fiber Amplifier Units if
they are mounted side by side.
18
E3X-DA-S/MDA
Amplifier Unit with Connector for
Sensor Communications Unit
E3X-MDA0
32.8
29.8
15.1
12.15
11.7
11.75
3.25
4.3
70
8.1
10
4.5
Four, 2.4 dia.
32
7
4.5
5.65
3.4
28.1
18.7
16
34.8
44.3
Two, 3.2 dia.
3.4
28.1
4.4
16
Amplifier Unit Connectors
Master Connectors
E3X-CN11
E3X-CN21
2,000 +500
Edge of amplifier
(7)
*
* E3X-CN11: 4 dia. cable / 3 conductors / Standard length: 2 m (Conductor cross section: 0.2 mm2 (AWG24), Insulator diameter: 1.1 mm)
E3X-CN21: 4 dia. cable / 4 conductors / Standard length: 2 m (Conductor cross section: 0.2 mm2 (AWG24), Insulator diameter: 1.1 mm)
Slave Connectors
E3X-CN12
E3X-CN22
2,000 +500
Edge of amplifier
(7)
*
* E3X-CN12: 2.6 dia. cable / 1 conductor / Standard length: 2 m (Conductor cross section: 0.2 mm2 (AWG24), Insulator diameter: 1.1 mm)
E3X-CN22: 4 dia. cable / 2 conductors / Standard length: 2 m (Conductor cross section: 0.2 mm2 (AWG24), Insulator diameter: 1.1 mm)
19
E3X-DA-S/MDA
Mobile Console
E3X-MC11-SV2
Mobile Console
AC adapter jack
Mobile Console Head
Communications jack
26
Menu indicators
22
Optical communications connection indicator
Communications jack
52.8
10
20
Channel indicator
(38.2)
13.1
16.3
28.8
31.8
13.2
Sensor
operation
indicator
1.2
5.1
12.3
Main display
17.3
24.3
Channel
buttons
27.7
30.3
Sub-display
9.9
136
UP key
Optical communications position
RIGHT key
M5 ball plunger
LEFT key
31.2
36.7
51.3
5.6
ESC/PWR key
DOWN
key
57
ENT key
Operation keys
Battery
indicators
12
26
50
Refer to E32 Series for details on Fiber Units.
20
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2014.9
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2014 All Right Reserved.