Download

Smart Fiber Amplifier Units
E3NX-FA
CSM_E3NX-FA_DS_E_14_3
A Smart Fiber Amplifier Unit with
Ultra-stable Detection and
Ultra-easy Setup
• Improved basic performance with 1.5 times the sensing distance and
approx. 1/10th the minimum sensing object.*
• Ultra-easy setup with Smart Tuning with a light intensity adjustment
range expanded 20 times to 40,000:1. Optimum stable detection
achieved with light intensity adjustment even for saturated incident light.
• White on black display characters for high visibility.
• Solution Viewer that shows the passing time and difference in incident
levels and Change Finder that allows you to see display values even
for fast workpieces.
* Compared to the E3X-HD.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Refer to the Safety Precautions on
page 12.
Ordering Information
Fiber Amplifier Units (Dimensions ➜ pages 13 and 15)
Type
Connecting method
Appearance
Model
Inputs/outputs
NPN output
PNP output
Pre-wired (2 m)
1 output
E3NX-FA11 2M
E3NX-FA41 2M
Wire-saving Connector
1 output
E3NX-FA6
E3NX-FA8
Pre-wired (2 m)
2 outputs + 1 input
E3NX-FA21 2M
E3NX-FA51 2M
1 output + 1 input
E3NX-FA7
E3NX-FA9
2 outputs
E3NX-FA7TW
E3NX-FA9TW
1 output + 1 input
E3NX-FA24
E3NX-FA54
2 outputs
---
E3NX-FA54TW
---
E3NX-FA0
Standard models
Advanced models
Wire-saving Connector
M8 Connector
Model for Sensor
Communications Unit *
Connector for Sensor
Communications Unit
* A Sensor Communications Unit is required if you want to use the Fiber Amplifier Unit on a network.
1
E3NX-FA
Accessories (Sold Separately)
Wire-saving Connectors (Required for models for Wire-saving Connectors.) (Dimensions ➜ page 15)
Connectors are not provided with the Fiber Amplifier Unit and must be ordered separately. *Protective stickers are provided.
Type
Appearance
Cable length No. of conductors
Model
Master Connector
4
E3X-CN21
Slave Connector
2
E3X-CN22
3
E3X-CN11
Applicable Fiber Amplifier Units
E3NX-FA7
E3NX-FA7TW
E3NX-FA9
E3NX-FA9TW
2m
Master Connector
E3NX-FA6
E3NX-FA8
Slave Connector
1
E3X-CN12
Sensor I/O Connectors (Required for models for M8 Connectors.) (Dimensions ➜ page 15)
Connectors are not provided with the Fiber Amplifier Unit and must be ordered separately.
Size
Cable
Appearance
Cable type
Straight
M8
5m
Standard cable
2m
L-shaped
A Mounting Bracket is not provided with the Fiber Amplifier Unit.
It must be ordered separately as required.
XS3F-M422-402-A
XS3F-M422-405-A
Related Products
Sensor Communications Units
Quantity
Type
E39-L143
1
Sensor Communications
Unit for EtherCAT
E3NW-ECT
Sensor Communications
Unit for CompoNet
E3NW-CRT
Sensor Communications
Unit for CC-Link
E3NW-CCL
Distributed Sensor Unit *
E3NW-DS
A DIN Track is not provided with the Fiber Amplifier Unit. It must
be ordered separately as required.
Type
Model
PFP-100N
Shallow type, total length: 0.5 m
PFP-50N
Deep type, total length: 1 m
PFP-100N2
1
End Plate (Dimensions ➜ page 16)
Two End Plates are provided with the Sensor Communications Unit.
End Plates are not provided with the Fiber Amplifier Unit. They
must be ordered separately as required.
Model
PFP-M
Appearance
Model
Quantity
Shallow type, total length: 1 m
Appearance
XS3F-M421-405-A
4-wire
Model
DIN Track (Dimensions ➜ page 16)
Appearance
XS3F-M421-402-A
5m
Mounting Bracket (Dimensions ➜ page 16)
Appearance
Model
2m
Quantity
1
Refer to your OMRON website for details.
* The Distributed Sensor Unit can be connected to any of the Sensor
Communications Units.
EtherCAT® is a registered trademark and patented
technology, licensed by Beckhoff Automation GmbH,
Germany.
CompoNet is a registered trademark of the ODVA.
CC-Link is a registered trademark of Mitsubishi Electric
Corporation. The trademark is managed by the CC-Link
Partner Association.
2
E3NX-FA
Ratings and Specifications
Type
NPN output
PNP output
Connecting
method
Item
Standard models
E3NX-FA11
E3NX-FA41
Pre-wired
E3NX-FA6
E3NX-FA8
Wire-saving
Connector
Model for Sensor
Communications
Unit
Advanced models
E3NX-FA21
E3NX-FA51
Pre-wired
E3NX-FA7 E3NX-FA7TW
E3NX-FA9 E3NX-FA9TW
E3NX-FA24
E3NX-FA54
Wire-saving Connector
1 output
1 input
2 outputs
---
--E3NX-FA54TW
M8 Connector
Inputs/
outputs
Outputs
External inputs
Light source (wavelength)
1 output
2 outputs
--1 input
Red, 4-element LED (625 nm)
1 output
1 input
Power supply voltage
10 to 30 VDC, including 10% ripple (p-p)
Power consumption∗2
At Power supply voltage of 24 VDC
Standard Models:
Normal mode : 840 mW max. (Current consumption at 35 mA max.)
Eco function ON : 650 mW max. (Current consumption at 27 mA max.)
Eco function LO : 750 mW max. (Current consumption at 31 mA max.)
2 outputs
---
E3NX-FA0
Connector for
Sensor
Communications
Unit
--- ∗1
Supplied from the connector
through the Sensor
Communications Unit
Advanced Models or Model for Sensor Communications Unit:
Normal mode : 920 mW max. (Current consumption at 38 mA max.)
Eco function ON : 680 mW max. (Current consumption at 28 mA max.)
Eco function LO : 800 mW max. (Current consumption at 33 mA max.)
Load power supply voltage: 30 VDC max., open-collector output
Load current: Groups of 1 to 3 Amplifier Units: 100 mA max., Groups of 4 to 30 Amplifier Units:
20 mA max.
Residual voltage:
At load current of less than 10 mA: 1 V max.
At load current of 10 to 100 mA: 2 V max.
Control output
---
OFF current: 0.1 mA max.
--Refer to ∗3.
--Refer to ∗3. --7-segment displays (Sub digital display: green, Main digital display: white)
Display direction: Switchable between normal and reversed.
OUT indicator (orange), L/D indicator (orange), ST indicator (blue), DPC indicator (green),
and OUT selection indicator (orange, only on models with 2 outputs)
External inputs
Indicators
Power supply reverse polarity protection, output short-circuit protection, and output reve rse
polarity protection
Protection circuits
Power supply
reverse polarity
protection and
output shortcircuit protection
Operate or reset for model with 1 output: 30 μs, with 2 outputs: 32 μs
Operate or reset: 250 μs
Operate or reset: 1 ms
Operate or reset: 16 ms
Smart
Tuning (2-point tuning, full auto tuning, position tuning, maximum sensitivity tuning, power tuning, or
Sensitivity adjustment
percentage tuning (−99% to 99%)) or manual adjustment
With E3NW-ECT:
30 units ∗5
With E3NW-CRT:
Maximum connectable Units
30
16 units
With E3NW-CCL:
16 units
Super-high-speed mode (SHS)∗4 0
No. of Units
High-speed mode (HS)
10
for mutual
interference Standard mode (Stnd)
10
prevention
Giga-power mode (GIGA)
10
Automatic power control (APC) Always enabled.
Dynamic power control (DPC) Provided
Functions
Timer
Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay + OFF-delay timer: 1 to 9,999 ms
Zero reset
Negative values can be displayed. (Threshold value is shifted.)
Resetting settings∗6
Select from initial reset (factory defaults) or user reset (saved settings).
Response
time
Super-high-speed mode (SHS)∗4
High-speed mode (HS)
Standard mode (Stnd)
Giga-power mode (GIGA)
*1. Two sensor outputs are allocated in the programmable logic controller PLC I/O table.
PLC operation via Communications Unit enables reading detected values and changing settings.
*2. At Power supply voltage of 10 to 30 VDC
Standard Models:
Normal mode
: 990 mW max. (Current consumption: 33 mA max. at 30 VDC, 65 mA max. at 10 VDC)
Eco function ON : 780 mW max. (Current consumption: 26 mA max. at 30 VDC, 42 mA max. at 10 VDC)
Eco function LO : 840 mW max. (Current consumption: 28 mA max. at 30 VDC, 45 mA max. at 10 VDC)
Advanced Models:
Normal mode
: 1,020 mW max. (Current consumption: 34 mA max. at 30 VDC, 67 mA max. at 10 VDC)
Eco function ON : 810 mW max. (Current consumption: 27 mA max. at 30 VDC, 44 mA max. at 10 VDC)
Eco function LO : 870 mW max. (Current consumption: 29 mA max. at 30 VDC, 48 mA max. at 10 VDC)
*3. The following details apply to the input.
Contact input (relay or switch)
Non-contact input (transistor)
NPN
ON: Shorted to 0 V (Sourcing current: 1 mA max.).
OFF: Open or shorted to Vcc.
ON: 1.5 V max. (Sourcing current: 1 mA max.)
OFF: Vcc − 1.5 V to Vcc (Leakage current: 0.1 mA max.)
PNP
ON: Shorted to Vcc (Sinking current: 3 mA max.).
OFF: Open or shorted to 0 V.
ON: Vcc − 1.5 V to Vcc (Sinking current: 3 mA max.)
OFF: 1.5 V max. (Leakage current: 0.1 mA max.)
Input time*3-1
ON: 9 ms min.
OFF: 20 ms min.
*3-1.Input time is 25 ms (ON)/(OFF) only when (in tUnE) or (in PtUn) input is selected.
*4. The mutual interference prevention function is disabled if the detection mode is set to super-high-speed mode.
*5. When connected to an OMRON NJ-series Controller.
*6. The bank is not reset by the user reset function or saved by the user save function.
3
E3NX-FA
Type
Model for Sensor
Communications
Unit
Advanced models
NPN output
E3NX-FA11 E3NX-FA6 E3NX-FA21 E3NX-FA7 E3NX-FA7TW
E3NX-FA24
PNP output
E3NX-FA41 E3NX-FA8 E3NX-FA51 E3NX-FA9 E3NX-FA9TW
E3NX-FA54 E3NX-FA54TW
Connecting
method
Item
Standard models
Pre-wired
Wiresaving
Connector
Wire-saving
Connector
Pre-wired
---
M8 Connector
E3NX-FA0
Connector for
Sensor
Communications
Unit
Eco mode∗7
Select from OFF (digital display lit), Eco ON (digital display not lit), and Eco LO (digital display dimmed).
Bank switching
Select from banks 1 to 4.
Power tuning
Select from ON or OFF.
Output 1
Select from normal detection mode or area detection mode.
Output 2
Select
from
normal
detection
mode,
alarm
output
mode, or
error
output
mode.
---
Functions
---
Select from input OFF,
tuning, power tuning,
emission OFF, zero
reset, or bank
switching.
Select
from
normal
detection
mode,
alarm
output
mode, or
error
output
mode.
---
Select from normal detection
mode, alarm output mode, or
error output mode.
---
Select
from input
OFF,
tuning,
power
tuning,
emission
OFF, zero
reset, or
bank
switching.
---
External input
---
Hysteresis width
Select from standard setting or user setting. For a user setting, the hysteresis width can be set from 0 to 9,999.
Ambient illumination (Receiver side)
Incandescent lamp: 20,000 lx max., Sunlight: 30,000 lx max.
Operating:
Groups of 1 or 2
Amplifier Units:
0 to 55°C,
Groups of 3 to 10
Amplifier Units:
0 to 50°C,
Groups of 11 to
16 Amplifier
Units:
0 to 45°C,
Groups of 17 to
30 Amplifier
Units:
0 to 40°C
Storage:
−30 to 70°C
(with no icing or
condensation)
Ambient temperature range∗8
Operating:
Groups of 1 or 2 Amplifier Units: −25 to 55°C,
Groups of 3 to 10 Amplifier Units: −25 to 50°C,
Groups of 11 to 16 Amplifier Units: −25 to 45°C,
Groups of 17 to 30 Amplifier Units: −25 to 40°C
Storage: −30 to 70°C (with no icing or condensation)
Ambient humidity range
Operating and storage: 35 to 85% (with no condensation) within the surrounding air temperature range shown above
Altitude
2,000 m max.
Installation environment
Pollution degree 3 (as per IEC 60947-1)
Insulation resistance
20 MΩ min. (at 500 VDC)
Dielectric strength
1,000 VAC at 50/60 Hz for 1 min
Vibration resistance (destruction)
10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance (destruction)
500 m/s for 3 times each in X, Y, and Z directions
Weight (packed state/Sensor only)
Approx. 115 g/ Approx. 60g/ Approx. 115 g/
approx. 75 g approx. 20g approx. 75 g Approx. 60g/approx. 20g
Materials
Accessories
150 m/s2 for 3
times each in X,
Y, and Z
directions
2
Case
Polycarbonate (PC)
Cover
Polycarbonate (PC)
Cable
PVC
Approx. 65 g/
approx. 25 g
Instruction Manual
*7. Eco LO is supported for Amplifier Units manufactured in July 2014 or later.
*8. When the number of connected units is 11 or more, the ambient temperature is less than 50°C.
4
E3NX-FA
Sensing Distances
Threaded Models
Sensing
method
Sensing
direction
Size
Right-angle
Throughbeam
M4
Straight
M3
Right-angle
M4
M6
M3
Reflective
M4
Straight
M6
Model
E32-T11N 2M
E32-LT11N 2M
E32-T11R 2M
E32-LT11 2M
E32-LT11R 2M
E32-C31N 2M
E32-C21N 2M
E32-D21N 2M
E32-C11N 2M
E32-LD11N 2M
E32-D21R 2M
E32-C31 2M
E32-C31M 1M
Giga mode
3,000
4,000*1
3,000
4,000*1
4,000*1
160
440
1,260
1,170
1,260
Sensing distance (mm)
Standard mode
High-speed mode
1,500
1,050
4,000*1
3,450
1,500
1,050
4,000*1
4,000*1
4,000*1
3,450
75
69
190
130
520
360
520
480
520
360
Super-high-speed mode
280
920
280
1,080
920
14
39
100
100
100
210
90
60
16
490
220
150
44
E32-D211R 2M
E32-D11R 2M
E32-CC200 2M
210
1,260
2,100
90
520
900
60
360
600
16
100
180
E32-LD11 2M
E32-LD11R 2M
1,290
1,260
540
520
370
360
110
100
Sensing distance (mm)
Standard mode
High-speed mode
370
220
600
330
1,500
1,050
670
390
90
60
Super-high-speed mode
60
90
280
100
16
*1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Cylindrical Models
Sensing
method
Throughbeam
Sensing
direction
Size
1 dia.
1.5 dia.
3 dia.
Top-view
Side-view
1.5 dia.
1.5 dia. +
0.5 dia.
Reflective
3 dia.
Top-view
3 dia. +
0.8 dia.
Model
E32-T223R 2M
E32-T22B 2M
E32-T12R 2M
E32-T14LR 2M
E32-D22B 2M
Giga mode
670
1,020
3,000
1,120
210
E32-D43M 1M
42
E32-D22R 2M
210
450
1,050
100
45
E32-D221B 2M
E32-D32L 2M
E32-D33 2M
18
12
4
90
60
16
210
450
130
300
40
90
30
8
Sensing distance (mm)
Standard mode
High-speed mode
1,500
1,050
Super-high-speed mode
280
Flat Models
Sensing
method
Throughbeam
Reflective
Sensing direction
Top-view
Side-view
Flat-view
Top-view
Side-view
Flat-view
Model
E32-T15XR 2M
E32-T15YR 2M
E32-T15ZR 2M
E32-D15XR 2M
E32-D15YR 2M
E32-D15ZR 2M
Giga mode
3,000
1,120
670
390
100
1,260
520
360
100
300
150
78
24
Sensing distance (mm)
Standard mode
High-speed mode
150
75
370
220
130
75
450
250
1,500
1,050
45
30
79
67
18
12
9
6
45
30
Super-high-speed mode
20
60
20
68
280
8
14
4
2
8
Sleeve Models
Sensing
method
Sensing direction
Side-view
Throughbeam
Top-view
Side-view
Reflective
Top-view
Model
E32-T24R 2M
E32-T24E 2M
E32-T33 1M
E32-T21-S1 2M
E32-TC200BR 2M
E32-D24R 2M
E32-D24-S2 2M
E32-D43M 1M
E32-D331 2M
E32-D33 2M
E32-D32-S1 0.5M
E32-D31-S1 0.5M
E32-DC200F4R 2M
E32-D22-S1 2M
E32-D21-S3 2M
E32-DC200BR 2M
E32-D25-S3 2M
Giga mode
250
670
220
760
3,000
100
180
42
21
100
94
40
27
7
210
90
60
16
370
160
100
30
1,260
370
520
160
360
100
100
30
5
E3NX-FA
Small-spot, Reflective Models
Type
Variable spot
Parallel light
Integrated lens
Spot diameter
Models
Giga mode
Standard mode
High-speed
mode
0.1 to 0.6 dia.
6 to 15
E32-C42 1M + E39-F3A
Spot diameter of 0.1 to 0.6 mm at 6 to 15 mm.
0.3 to 1.6 dia.
10 to 30
E32-C42 1M + E39-F17
Spot diameter of 0.3 to 1.6 mm at 10 to 30 mm.
4 dia.
0 to 20
E32-C31 2M + E39-F3C
E32-C31N 2M + E39-F3C
5
E32-C42S 1M
Spot diameter of 0.1 mm at 5 mm.
6 dia.
50
E32-L15 2M
Spot diameter of 6 mm at 50 mm.
E32-C41 1M + E39-F3A-5
Spot diameter of 0.1 mm at 7 mm.
7
0.5 dia.
E32-C31 2M + E39-F3A-5
E32-C31N 2M + E39-F3A-5
0.2 dia.
E32-C41 1M + E39-F3B
17
0.5 dia.
E32-C31 2M + E39-F3B
E32-C31N 2M + E39-F3B
3 dia.
50
E32-CC200 2M + E39-F18
E32-C11N 2M + E39-F18
Super-highspeed mode
Spot diameter of 4 mm max. at 0 to 20 mm.
0.1 dia.
0.1 dia.
Small-spot
Sensing distance (mm)
Center
distance (mm)
Spot diameter of 0.5 mm at 7 mm.
Spot diameter of 0.2 mm at 17 mm.
Spot diameter of 0.5 mm at 17 mm.
Spot diameter of 3 mm at 50 mm.
High-power Beam Models
Type
Through-beam
models with
integrated lens
Sensing distance (mm)
Sensing
direction
Aperture angle
Right-angle
15°
E32-LT11N 2M
4,000*2
4,000*2
3,450
920
10°
E32-T17L 10M
20,000*1
20,000*1
20,000*1
8,000
1,080
Top-view
Right-angle
Top-view
Side-view
Top-view
Side-view
Through-beam
models with
lenses
Top-view
Side-view
Top-view
Side-view
Top-view
Side-view
Top-view
Reflective
models with
integrated lens
Top-view
Giga mode
Standard mode
High-speed
mode
Super-highspeed mode
E32-LT11 2M
4,000*2
4,000*2
4,000*2
E32-LT11R 2M
4,000*2
4,000*2
3,450
920
30°
E32-T14 2M
4,000*2
4,000*2
4,000*2
1,800
12°
E32-T11N 2M + E39-F1
4,000*2
4,000*2
4,000*2
2,000
6°
E32-T11N 2M + E39-F16
4,000*2
4,000*2
4,000*2
3,600
12°
E32-T11R 2M + E39-F1
4,000*2
4,000*2
4,000*2
2,000
6°
E32-T11R 2M + E39-F16
4,000*2
4,000*2
4,000*2
3,600
60°
E32-T11R 2M + E39-F2
2,170
1,200
750
200
12°
E32-T11 2M + E39-F1
4,000*2
4,000*2
4,000*2
1,860
4,000*2
4,000*2
4,000*2
4,000*2
3,450
1,980
1,290
320
15°
Side-view
Models
6°
E32-T11 2M + E39-F16
60°
E32-T11 2M + E39-F2
12°
E32-T51R 2M + E39-F1
4,000*2
4,000*2
4,000*2
1,500
4,000*2
4,000*2
4,000*2
4,000*2
2,100
1,080
750
200
6°
E32-T51R 2M + E39-F16
60°
E32-T51R 2M + E39-F2
12°
E32-T81R-S 2M + E39-F1
4,000*2
4,000*2
4,000*2
1,000
4,000*2
4,000*2
4,000*2
1,800
1,500
820
540
140
6°
E32-T81R-S 2M + E39-F16
60°
E32-T81R-S 2M + E39-F2
12°
E32-T61-S 2M + E39-F1
4,000*2
4,000*2
4,000*2
1,800
4,000*2
4,000*2
4,000*2
3,100
2,520
1,350
900
240
6°
E32-T61-S 2M + E39-F16
60°
E32-T61-S 2M + E39-F2
12°
E32-T51 2M + E39-F1-33
4,000*2
4,000*2
3,450
1,400
6°
E32-T51 2M + E39-F16
4,000*2
4,000*2
4,000*2
4,000*2
4°
E32-D16 2M
40 to 4,000 *2
40 to 2,100
40 to 1,350
40 to 480
*1. The fiber length is 10 m on each side, so the sensing distance is given as 20,000 mm.
*2. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Narrow View Models
Sensing
method
Sensing
direction
Sensing distance (mm)
Aperture angle
1.5°
Through-beam
Side-view
3.4°
4°
Models
Giga mode
E32-A03 2M
E32-A03-1 2M
E32-A04 2M
Standard mode
4,000*1
2,670
High-speed
mode
Super-highspeed mode
1,800
500
1,920
1,020
670
200
E32-T24SR 2M
4,000*1
3,300
2,190
580
E32-T24S 2M
4,000*1
3,900
2,610
700
E32-T22S 2M
4,000*1
4,000*1
3,750
1,000
*1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
6
E3NX-FA
Models for Detection without Background Interference
Sensing
method
Sensing direction
Model
Sensing distance (mm)
Giga mode
Standard mode
Flat-view
Limitedreflective
Side-view
High-speed mode
0 to 15
E32-L16-N 2M
Super-high-speed mode
0 to 12
E32-L24S 2M
0 to 4
E32-L25L 2M
5.4 to 9 (center 7.2)
Transparent Object Detection (Retro-reflective Models)
Sensing
method
Retro-reflective
Feature
Size
Models
Film detection
M3
E32-C31 2M +
E39-F3R +
E39-RP37
Square
---
E32-R16 5M
Threaded
Sensing distance (mm)
Giga mode
Standard mode
Hex-shaped
E32-LR11NP 2M +
E39-RP1
Super-high-speed mode
300
---
370
150 to 1,500
10 to 370
E32-R21 2M
M6
High-speed mode
2,020
10 to 250
1,800
1,500
550
Transparent Object Detection (Limited-reflective Models)
Sensing
method
Feature
Sensing direction
Small size
Sensing distance (mm)
Giga mode
Standard mode
Standard/long-distance
Super-high-speed mode
E32-L16-N 2M
0 to 15
0 to 12
E32-A08 2M
10 to 20
---
E32-A12 2M
12 to 30
---
Flat-view
Glass substrate
alignment, 70°C
High-speed mode
0 to 4
E32-L24S 2M
Standard
Limitedreflective
Model
Side-view form
Side-view
E32-L25L 2M
Glass substrate
mapping, 70°C
Top-view
E32-A09 2M
5.4 to 9 (center 7.2)
15 to 38
---
Chemical-resistant, Oil-resistant Models
Sensing
method
Through-beam
Type
Sensing direction
Oil-resistant
Right-angle
Chemical/oil-resistant
Chemical/oil-resistant at
150°C
Top-view
Semiconductors: Resist
stripping; 85°C
Sensing distance (mm)
Giga mode
Standard mode
High-speed mode
Super-high-speed mode
E32-T11NF 2M
4,000*1
4,000*1
4,000*1
2,200
E32-T12F 2M
4,000*1
4,000*1
4,000*1
1,600
E32-T11F 2M
4,000*1
4,000*1
3,900
1,000
Side-view
E32-T14F 2M
2,100
1,200
750
200
Top-view
E32-T51F 2M
4,000*1
4,000*1
2,700
700
Semiconductors:
Cleaning, developing,
and etching; 60°C
Reflective
Model
Top-view
E32-L11FP 5M
8 to 20 mm from tip of lens (Recommended sensing distance: 11 mm),
19 to 31 mm from center of mounting hole A (Recommended sensing distance: 22 mm)
E32-L11FS 5M
8 to 20 mm from tip of lens (Recommended sensing distance: 11 mm),
32 to 44 mm from center of mounting hole A (Recommended sensing distance: 35 mm)
Chemical/oil-resistant
E32-D12F 2M
Chemical-resistant
cable
E32-D11U 2M
---*2
1,260
280
190
60
520
360
100
*1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
*2. Even if there is no sensing object, the Sensor will detect light that is reflected by the fluororesin.
Bending-resistant Models
Sensing
method
Size
1.5 dia.
Through-beam
M3
M4
E32-T22B 2M
E32-T21 2M
E32-T11 2M
Square
32-T25XB 2M
1.5 dia.
E32-D22B 2M
M3
Reflective
Model
E32-D21 2M
3 dia.
E32-D221B 2M
M4
E32-D21B 2M
M6
Square
E32-D11 2M
E32-D25XB 2M
Sensing distance (mm)
Giga mode
Standard mode
High-speed mode Super-high-speed mode
1,020
600
330
90
3,750
2,020
1,350
360
750
450
250
70
210
90
60
16
450
210
130
40
1,260
520
360
100
360
150
90
30
7
E3NX-FA
Heat-resistant Models
Sensing
method
Heat-resistant temperature
Through-beam
100°C
E32-T51R 2M
150°C
E32-T51 2M
200°C
E32-T81R-S 2M
Sensing distance (mm)
Giga mode
Standard mode
High-speed mode
Super-high-speed mode
2,400
1,200
840
225
4,000*1
2,250
1,500
400
1,500
820
540
140
240
350°C
E32-T61-S 2M
2,520
1,350
900
100°C
E32-D51R 2M
1,000
420
280
80
150°C
E32-D51 2M
1,680
670
480
144
200°C
E32-D81R-S 2M
270
180
300°C
Reflective
Model
630
10 to 20
---
E32-A09H2 2M
20 to 30 (center 25)
---
E32-D611-S 2M
350°C
E32-D61-S 2M
400°C
54
E32-A08H2 2M
E32-D73-S 2M
630
270
180
54
420
180
120
36
*1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Area Detection Models
Sensing
method
Type
Through-beam
Area
Reflective
Array
Sensing width
Model
Sensing distance (mm)
Giga mode
Standard mode
High-speed mode
Super-high-speed mode
E32-T16PR 2M
4,000*1
2,550
1,680
440
E32-T16JR 2M
4,000*1
2,250
1,440
380
30 mm
E32-T16WR 2M
4,000*1
3,900
2,550
680
11 mm
E32-D36P1 2M
1,050
450
300
90
11 mm
*1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Liquid-level Detection Models
Sensing
method
Tube-mounting
Liquid contact
(heat-resistant
up to 200°C)
Model
Sensing distance (mm)
Tube diameter
Feature
3.2, 6.4, or 9.5 dia
Stable residual
quantity detection
E32-A01 5M
Applicable tube: Transparent tube with a diameter of 3.2, 6.4, or 9.5 mm, Recommended
wall thickness: 1 mm
8 to 10 dia
Mounting at
multiple levels
E32-L25T 2M
Applicable tube: Transparent tube with a diameter of 8 to 10 mm, Recommended wall
thickness: 1 mm
No restrictions
Large tubes
E32-D36T 5M
Applicable tube: Transparent tube (no restrictions on diameter)
---
---
E32-D82F1 4M
Liquid-contact type
Giga mode
Standard mode
High-speed mode
Super-high-speed mode
Vacuum-resistant Models
Sensing
method
Heat-resistant temperature
Model
E32-T51V 1M
Through-beam
Sensing distance (mm)
Giga mode
Standard mode
High-speed mode
Super-high-speed mode
1,080
600
390
100
120°C
E32-T51V 1M + E39F1V
2,000*1
2,000*1
2,000*1
520
200°C
E32-T84SV 1M
2,000*1
1,420
960
260
*1. The fiber length is 1 m on each side, so the sensing distance is given as 2,000 mm.
Models for FPD, Semiconductors, and Solar Cells
Sensing
method
Application
Glass presence
detection
Operating
temperature
70°C
Model
Sensing distance (mm)
Giga mode
300°C
70°C
Limitedreflective
Glass substrate
mapping
Super-high-speed mode
0 to 12
10 to 20
---
E32-A12 2M
12 to 30
---
E32-A09 2M
15 to 38
---
20 to 30 (center 25)
---
E32-A08H2 3M
300°C
E32-A09H2 2M
Wet processes:
Cleaning, Resist
developing and
etching
60°C
E32-L11FP 5M
8 to 20 mm from tip of lens (Recommended sensing distance: 11 mm),
19 to 31 mm from center of mounting hole A (Recommended sensing distance: 22 mm)
Wet process: Resist
stripping
85°C
E32-L11FS 5M
8 to 20 mm from tip of lens (Recommended sensing distance: 11 mm),
32 to 44 mm from center of mounting hole A (Recommended sensing distance: 35 mm)
E32-A03 2M
E32-A03-1 2M
Through-beam
High-speed mode
0 to 15
E32-L16-N 2M
E32-A08 2M
Glass substrate
alignment
Standard mode
Wafer mapping
70°C
E32-A04 2M
4,000*1
2,670
1,800
500
200
1,920
1,020
670
E32-T24SR 2M
4,000*1
3,300
2,190
580
E32-T24S 2M
4,000*1
3,900
2,610
700
*1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
8
E3NX-FA
I/O Circuit Diagrams
NPN Output
Model
Operation
mode
Timing chart
Light-ON
Incident light
No incident light
OUT indicator Lit
Not lit
(orange)
ON
Output
OFF
transistor
Operate
Load
(e.g., relay) Reset
(Between brown and
black leads)
E3NX-FA11
E3NX-FA6
Dark-ON
Incident light
No incident light
OUT indicator Lit
Not lit
(orange)
ON
Output
OFF
transistor
Operate
Load
(e.g., relay) Reset
(Between brown and
black leads)
Light-ON
ch1/
Incident light
ch2 No incident light
OUT indicator Lit
Not lit
(orange)
ON
Output
OFF
transistor
Operate
Load
(e.g., relay) Reset
(Between brown and
black (orange) leads)
L/D indicator
L lit.
Dark-ON
Light-ON
Incident light
No incident light
OUT indicator Lit
Not lit
(orange)
ON
Output
OFF
transistor
Operate
Load
(e.g., relay) Reset
(Between brown and
black leads)
E3NX-FA7
E3NX-FA24
Dark-ON
Light-ON
Incident light
No incident light
OUT indicator Lit
Not lit
(orange)
ON
Output
OFF
transistor
Operate
Load
(e.g., relay) Reset
(Between brown and
black leads)
ch1/
Incident light
ch2 No incident light
OUT indicator Lit
Not lit
(orange)
ON
Output
OFF
transistor
Operate
Load
(e.g., relay) Reset
(Between brown and
black (orange) leads)
Dark-ON
Brown
Load
Black
Control output
10 to
30 VDC
Blue
D lit.
L lit.
Display
OUT1
indicator
(orange)
OUT2 indicator
(orange)
Brown
Load
Black
Control output Load
Orange ch1
Control output
ch2
Pink
Photoelectric
sensor main
circuit
10 to
30 VDC
External
input
Blue
D lit.
Display OUT indicator (orange)
1
L lit.
4
Photoelectric
sensor main
circuit
3
D lit.
• M8 Connector Pin Arrangement
2
1
L lit.
Display
OUT1
indicator
(orange)
OUT2 indicator
(orange)
Photoelectric
sensor main
circuit
Brown
Load
Black
Control output
10 to
30 VDC
2
E3NX-FA7TW
Incident light
ch1/
ch2 No incident light
OUT indicator Lit
Not lit
(orange)
ON
Output
OFF
transistor
Operate
Load
(e.g., relay) Reset
(Between brown and
black (orange) leads)
Display OUT indicator (orange)
Photoelectric
sensor main
circuit
E3NX-FA21
Incident light
ch1/
ch2 No incident light
OUT indicator Lit
Not lit
(orange)
ON
Output
OFF
transistor
Operate
Load
(e.g., relay) Reset
(Between brown and
black (orange) leads)
Output circuit
Orange
Blue
External
input
4
3
Brown
Load
Black
Control output Load
Orange ch1
Control output
ch2
10 to
30 VDC
Blue
D lit.
9
E3NX-FA
PNP Output
Operation
mode
Model
Light-ON
Timing chart
Incident light
No incident light
OUT indicator Lit
Not lit
(orange)
ON
Output
OFF
transistor
Operate
Load
(e.g., relay) Reset
L/D indicator
L lit.
Output circuit
Display OUT indicator (orange)
(Between blue and
black leads)
E3NX-FA41
E3NX-FA8
Dark-ON
Incident light
No incident light
OUT indicator Lit
Not lit
(orange)
ON
Output
OFF
transistor
Operate
Load
(e.g., relay) Reset
Brown
Control
Black output
Photoelectric
sensor main
circuit
10 to
30 VDC
Load
Blue
D lit.
(Between blue and
black leads)
Light-ON
ch1/
Incident light
ch2 No incident light
OUT indicator Lit
Not lit
(orange)
ON
Output
OFF
transistor
Operate
Load
(e.g., relay) Reset
L lit.
Dark-ON
Incident light
ch1/
ch2 No incident light
OUT indicator Lit
Not lit
(orange)
ON
Outputs
OFF
transistor
Operate
Load
(e.g., relay) Reset
Brown
OUT1
indicator
(orange)
(Between blue and
black (orange) leads)
E3NX-FA51
OUT2 indicator (orange)
Display
External
Pink
input
Control output
Black
ch1
Control output
Orange ch2 Load
Photoelectric
sensor main
circuit
Blue
10 to
30 VDC
Load
D lit.
(Between blue and
black (orange) leads)
Light-ON
Incident light
No incident light
OUT indicator Lit
Not lit
(orange)
ON
Output
OFF
transistor
Operate
Load
(e.g., relay) Reset
Display OUT indicator (orange)
1
L lit.
2
Photoelectric
sensor main
circuit
(Between blue and
black leads)
E3NX-FA9
E3NX-FA54
Dark-ON
Incident light
No incident light
OUT indicator Lit
Not lit
(orange)
ON
Output
OFF
transistor
Operate
Load
(e.g., relay) Reset
4
External
Orange
input
Control
Black output
10 to
30 VDC
Load
3
D lit.
Brown
• M8 Connector Pin Arrangement
2
Blue
4
1
3
(Between blue and
black leads)
Light-ON
ch1/
Incident light
ch2 No incident light
OUT indicator Lit
Not lit
(orange)
ON
Output
OFF
transistor
Operate
Load
(e.g., relay) Reset
OUT2 indicator (orange)
Display
1
L lit.
OUT1
indicator
(orange)
(Between blue and
black (orange) leads)
E3NX-FA9TW
E3NX-FA54TW
Dark-ON
Incident light
ch1/
ch2 No incident light
OUT indicator Lit
Not lit
(orange)
ON
Outputs
OFF
transistor
Operate
Load
(e.g., relay) Reset
Control output
Black
ch1
Control output
Orange ch2 Load
2
Photoelectric
sensor main
circuit
4
3
D lit.
Brown
• M8 Connector Pin Arrangement
2
1
Blue
10 to
30 VDC
Load
4
3
(Between blue and
black (orange) leads)
Plug (Sensor I/O Connector)
Terminal number
4
3
2
1
Wire color
Brown
White
Blue
Black
1
2
3
4
XS3F-M421-402-A
XS3F-M421-405-A
Wire color
Connection pin
Application
Brown
1
Power supply (+V)
White
2
External input / Output
Blue
3
Power supply (0 V)
Black
4
Output
XS3F-M422-402-A
XS3F-M422-405-A
10
E3NX-FA
Nomenclature
E3NX-FA11/FA41/FA6/FA8/FA7/FA9/FA24/FA54
[L/D Indicator]
Indicates the setting status:
Light-ON (L) or Dark-ON (D).
[DPC Indicator]
Turns ON when Dynamic
Power Control is effective.
[OUT Indicator]
Turns ON when the output is ON.
[
[ L/D Button]
Use to switch between Light-ON (L)
and Dark-ON (D).
[ST Indicator]
Turns ON when Smart
Tuning is in progress.
Threshold Level Incident Level
White digital display
Green digital
display
Tune Button]
Executes Smart Tuning.
[ MODE Button]
Use to switch between Detection Mode and Setting Mode.
[+ −UP/DOWN Button]
Used to fine-tune the threshold or change set values.
E3NX-FA21/FA51/FA7TW/FA9TW/FA54TW/FA0
[L/D Indicator]
Indicates the setting status:
Light-ON (L) or Dark-ON (D).
[OUT1 Indicator/OUT2 Indicator]
Turns ON when OUT1 or OUT2 is ON.
[
Tune Button]
Executes Smart Tuning.
[DPC Indicator]
Turns ON when Dynamic Power
Control is effective.
[ L/D Button]
Use to switch between Light-ON (L) and Dark-ON (D).
[ST Indicator]
Turns ON when Smart
Tuning is in progress.
Threshold Level
Green digital display
Incident Level
White digital
display
[OUT1 Selection Indicator/OUT2 Selection Indicator]
The indicator for the selected output channel is lit.
[ MODE Button]
Use to switch between Detection Mode and Setting Mode,
and use to switch between OUT1 and OUT2.
[+ −UP/DOWN Button]
Used to fine-tune the threshold or change set values.
11
E3NX-FA
Safety Precautions
To ensure safe operation, be sure to read and follow the Instruction Manual provided with the Sensor.
WARNING
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
Do not use the product with voltage in excess of the
rated voltage. Excess voltage may result in
malfunction or fire.
Never use the product with an AC power supply.
Otherwise, explosion may result.
Precautions for Safe Use
The following precautions must be observed to ensure safe operation
of the Amplifier Unit. Doing so may cause damage or fire.
1. Do not install the product in the following locations.
• Locations subject to direct sunlight
• Locations subject to condensation due to high humidity
• Locations subject to corrosive gas
• Locations subject to vibration or mechanical shocks exceeding the
rated values
• Locations subject to exposure to water, oil, chemicals
• Locations subject to stream
• Locations subjected to strong magnetic field or electric field
2. Do not use the product in environments subject to flammable or
explosive gases.
3. Do not use the product in any atmosphere or environment that
exceeds the ratings.
4. To secure the safety of operation and maintenance, do not install
the product close to high-voltage devices and power devices.
5. High-voltage lines and power lines must be wired separately from
the product. Wiring them together or placing them in the same duct
may cause induction, resulting in malfunction or damage.
6. Do not apply any load exceeding the ratings. Otherwise, damage
or fire may result.
7. Do not short the load. Otherwise, damage or fire may result.
8. Connect the load correctly.
9. Do not miswire such as the polarity of the power supply.
10.Do not use the product if the case is damaged.
11.Burn injury may occur. The product surface temperature rises
depending on application conditions, such as the ambient
temperature and the power supply voltage. Attention must be paid
during operation or cleaning.
12.When setting the sensor, be sure to check safety such as by
stopping the equipment.
13.Be sure to turn off the power supply before connecting or
disconnecting wires.
14.Do not attempt to disassemble, repair, or modify the product in any
way.
15.When disposing of the product, treat it as industrial waste.
16.Do not use the Sensor in water, rainfall, or outdoors.
17.UL Standard Certification (Applicable Models: E3NX-FA11/21/41/51
Only)
Only the sensors with Enhanced UL Certification Mark are certified
by UL. They are intended to be supplied by a "Class 2 circuit". When
used in United States and Canada, Please use the same Class 2
source for input and output.The overcurrent protection current rating
is 2A max. They were evaluated as Open type and shall be installed
within a enclosure.
Precautions for Correct Use
1. Be sure to mount the unit to the DIN track until it clicks.
2. When using the Amplifier Units with Wire-saving Connectors,
attach the protective stickers (provided with E3X-CN-series
Connectors) on the unused power pins to prevent electrical shock
and short circuiting.
When using the Amplifier Units with Connectors for
Communications Units, attach the protective caps (provided with
E3NW-series Sensor Communications Unit).
Amplifier Unit with Wiresaving Connector
Amplifier Unit with Connector
for Communications Unit
Protective sticker
Power supply connecting
terminals
Protective cap
3. The length for the cable extension must be 30 m or less (or less
than 10 m for S-mark certified models). Be sure to use a cable of
at least 0.3 mm2 for extension. The power voltage must be 24 to
30 V when connecting amplifier units with extension cable and
wire-saving connector.
4. Do not apply the forces on the cord exceeding the following limits:
Pull: 40N; torque: 0.1N·m; pressure: 20N; bending: 29.4N
5. Do not apply excessive force such as tension, compression or
torsion to the Amplifier Unit with the Fiber Unit fixed to the Amplifier
Unit.
6. Always keep the protective cover in place when using the Amplifier
Unit. Not doing so may cause malfunction.
7. It may take time until the received light intensity and measured
value become stable immediately after the power is turned on
depending on use environment.
8. The product is ready to operate 200 ms after the power supply is
turned ON.
9. The Mobile Console E3X-MC11, E3X-MC11-SV2 and E3X-MC11S cannot be connected.
10.The mutual interference prevention function does not work when
in combination with E3C/E2C/E3X.
11.If the unit receives excessive sensor light, the mutual interference
prevention function may not work properly, resulting in malfunction
of the unit. In such case, increase the threshold.
12.Standard models and Advanced models
The Sensor Communication Unit E3X-DRT21-S, E3X-CRT, E3XECT and E3NW cannot be connected.
Model for Sensor Communication Unit (E3NX-FA0)
The Sensor Communication Unit E3NW can be connected.
E3X-DRT21-S, E3X-CRT, E3X-ECT cannot be connected.
13.If you notice an abnormal condition such as a strange odor,
extreme heating of the unit, or smoke immediately stop using the
product, turn off the power, and consult your dealer.
14.Do not use thinner, benzene, acetone, and lamp oil for cleaning.
12
E3NX-FA
(Unit: mm)
Dimensions
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
Fiber Amplifier Units
Pre-wired Amplifier Units
E3NX-FA11
E3NX-FA21
E3NX-FA41
E3NX-FA51
E3NX-FA21/FA51
E3NX-FA11/FA41
L/D indicator
DPC indicator
21.7
ST indicator
21
27.1
*Cable Specifications
L/D
indicator
DPC
indicator
ST
indicator
OUT2 selection
indicator
27.8
OUT2 indicator
Outer
No. of
Others
Model
diameter conductors
E3NX-FA11
Conductor cross-section: 0.2 mm2
4.0 dia.
3
E3NX-FA41
Insulator dia.: 0.9 mm
E3NX-FA21
Standard cable length: 2 m
4.0 dia.
5
E3NX-FA51
Minimum bending radius: 12 mm
OUT1 indicator
OUT1 selection indicator
OUT indicator
Incident level
(white, digital)
Threshold level
(green, digital)
Threshold level (green, digital)
Incident level (white, digital)
With Mounting Bracket Attached
Mounted to DIN Track
10
5.1
5.1
147.1 (max. value with cover open)
71.8
170° (max. value with cover open)
104.8
(max. value
with cover
open)
Two,
2.4-dia.
fiber unit holes
4.5
33.5
33.5
(16.5)
(37)
3.4
5.7
(37.9)
12.7
*
4.3
Optical communications
20.5
3.4
12.7
*
Fiber Attachment
(E39-F9) attached
(16.5)
(37)
Two, 3.2 dia.
(mounting holes)
(20.3)
Optical communications
(9.4)
20.5
71.8
PFP-@N DIN Track
(sold separately)
16
4.4
E39-L143 Mounting Bracket
(sold separately, SUS304)
3.4
Mounting Holes
Two, M3 holes
(29.9)
16
Amplifier Units with Wire-saving Connectors
E3NX-FA6
E3NX-FA7
E3NX-FA6/FA7/FA8/FA9
E3NX-FA7TW
DPC
indicator
ST indicator
E3NX-FA8
E3NX-FA9
L/D indicator
21.7
27.1
E3NX-FA9TW
16
E3NX-FA7TW/FA9TW
L/D indicator
OUT2 selection indicator
DPC indicator
21
*Cable Specifications
27.8
Model
Outer diameter
E3X-CN12
2.6 dia.
ST indicator
OUT2 indicator
No. of conductors
1
2
E3X-CN22
OUT1 indicator
OUT indicator
E3X-CN11
Threshold level
(green, digital)
Incident level
(white, digital)
Threshold level (green, digital)
4
With Mounting Bracket Attached
147.1 (max. value with cover open)
5.1
3
Incident level (white, digital)
Mounted to DIN Track
10
4.0 dia.
E3X-CN21
OUT1 selection indicator
(75.3)
5.1
170° (max. value with cover open)
104.8
(max. value
with cover
open)
4.5
Two,
2.4-dia.
fiber unit holes
33.5
33.5
(16.5)
(16.5)
(37)
(37)
3.4
*
5.7
With Fiber Attachment
(E39-F9) attached
(13)
*
4.3
Optical communications
20.5
(37.9)
(23.8)
(75.3)
3.4
Two, 3.2 dia.
(mounting holes)
Wire-saving Connector
(sold separately)
20.5
PFP-@N DIN Track
(sold separately)
(9.4)
16
4.4
3.4
(13)
Wire-saving Connect
(sold separately)
Optical communications
E39-L143 Mounting Bracket
(sold separately, SUS304)
Mounting Holes
Two, M3 holes
(29.9)
16
16
13
E3NX-FA
Amplifier Units with M8 Connectors
E3NX-FA24
E3NX-FA54
E3NX-FA54TW
E3NX-FA24/FA54
L/D indicator
E3NX-FA54TW
ST indicator
DPC indicator
OUT2 selection indicator
21.7
27.1
21
27.8
OUT2 indicator
4.2
6.9
5.2
OUT indicator
Threshold level (green, digital)
ST indicator
Incident level
(white, digital)
OUT1 selection indicator
Threshold level
(green, digital)
147.1 (max. value with cover open)
5.1
Two,
2.4-dia.
fiber unit holes
4.5
1
3
71.8
170° (max. value with cover open)
104.8
(max. value
with cover
open)
4
With Mounting Bracket Attached
Mounted to DIN Track
5.1
2
OUT1 indicator
Incident level
(white, digital)
10
Connector pin
arrangement
L/D indicator
DPC indicator
33.5
(16.5)
(5.7)
3.4
(37)
4.9
12.7
3.4
5.7
4.8
20.5
20.5
M8 Connector
(37.9)
(20.3)
Two, 3.2 dia.
(mounting holes)
71.8
(9.4)
4.3
16
(37.9)
(20.5)
E39-L143 Mounting Bracket (sold separately, SUS304)
PFP-@N DIN Track
(sold separately)
Optical communications
4.4
3.4
Mounting Holes
Two, M3 holes
(29.9)
16
16
Amplifier Unit with Connector for Sensor Communications Unit
E3NX-FA0
OUT2 selection indicator
L/D indicator
DPC indicator
ST indicator
OUT2 indicator
21
27.8
OUT1 indicator
OUT1 selection indicator
Incident level (white, digital)
Threshold level (green, digital)
13.8
Mounted to DIN Track
11.5
10
5.1
140 (max. value with cover open)
152° (max. value with cover open)
104.8
(max. value
with cover
open)
4.5
Two,
2.4-dia.
fiber unit holes
33.5
(37)
(16.5)
26
(29.9)
3.4
5.7
With Fiber Attachment
(E39-F9) attached
Optical communications
20.5
(39.3)
(37.9)
90.8
PFP-@N DIN Track
(sold separately)
14
E3NX-FA
Accessories (Sold Separately)
Wire-saving Connectors
Master Connector
E3X-CN11
Edge of Amplifier Unit
E3X-CN21
2,000+500
(7)
*
* E3X-CN11: 4-dia. cable with 3 conductors, Standard cable length: 2 m (Conductor cross-section: 0.2 mm2 (AWG24), Insulator diameter: 1.1 mm)
E3X-CN21: 4-dia. cable with 4 conductors, Standard cable length: 2 m (Conductor cross-section: 0.2 mm2 (AWG24), Insulator diameter: 1.1 mm)
Slave Connector
E3X-CN12
Edge of Amplifier Unit
E3X-CN22
2,000+50
0
(7)
*
* E3X-CN12: 2.6-dia. cable with 1 conductor, Standard cable length: 2 m (Conductor cross-section: 0.2 mm2 (AWG24), Insulator diameter: 1.1 mm)
E3X-CN22: 4-dia. cable with 2 conductors, Standard cable length: 2 m (Conductor cross-section: 0.2 mm2 (AWG24), Insulator diameter: 1.1 mm)
Sensor I/O Connectors
Straight
XS3F-M421-40@-A
2.15 M8
4
2
3
1
12.9
4 dia.
9 dia.
1.95 0.5
21.5
3.4
30
5
50
31.4
L
L-shaped
XS3F-M422-40@-A
50
L
23.1
20.5
30
5
4 dia.
9 dia.
3.4
2.15
0.5
1.95
15
E3NX-FA
Mounting Bracket
E39-L143
34.8
22
16
2.5
(10.3)
3
Mounting Holes
7.3
5.3
Two, M3 holes
26.8
3.2 -dia. holes
3
16
7
16±0.1
3
Four, Radius: 1.7
10.3 10 max. 7
3.4
Material: Stainless steel (SUS304)
1
3.4
1
DIN Track
PFP-100N
PFP-50N
7.3±0.15
4.5
35±0.3
15
25
10
25
25
1,000 (500)*
25
10
27±0.15
15 (5)*
1
*Dimensions in parentheses are for the PFP-50N.
Material: Aluminum
PFP-100N2
16
4.5
35±0.3 27
15
25
25
10
25
1,000
10
25
15
24
29.2
1
1.5
Material: Aluminum
End Plate
PFP-M
11.5
50
M4×8
panhead screw
10
M4 spring washer
4.8
6.2
10
1
1.3
1.8
35.5
Materials: Iron, zinc plating
1.8
35.3
16
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2016.5
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2016 All Right Reserved.