MOS FET Relays
G3VM-41PR5
Smallest 40V MOS FET Relay In The Market (USOP
Package); Designed to exhibit Low Output
Capacitance and ON Resistance (C × R = 10 pF•Ω)
• Specifically Designed for low ON resistance of 1 Ω (typical).
• Dielectric strength of 500 Vrms between I/O.
• RoHS compliant.
■ Application Examples
• Semiconductor test equipment
• Test & Measurement devices and Data loggers
• Communication equipment
Note: The actual product is marked differently from the image shown here.
■ List of Models
Package type
USOP4
Contact form
SPST-NO
(1FormA)
Terminals
Load voltage (peak value)
Surface-mounting
terminals
40 VAC or VDC
Model
Number per tape
G3VM-41PR5
---
G3VM-41PR5(TR05)
500
■ Dimensions
Note:
All units are in millimeters unless otherwise indicated.
G3VM-41PR5
3.25
2PA
103
2.05
0.15 1.65
(0.4)
Note: The actual product is marked differently
from the image shown here.
0.2
1.27
2.85
2.2
Weight: 0.03 g
(0.35)
■ Terminal Arrangement/Internal Connections (Top View)
G3VM-41PR5
4P5
Model name
OMRON mark
103
LOT No.
Note: The actual product is marked differently
from the image shown here.
■ Actual Mounting Pad Dimensions (Recommended Value, Top View)
G3VM-41PR5
0.85
2.9
0.8
1.27
MOS FET Relays
G3VM-41PR5
1
■ Absolute Maximum Ratings (Ta = 25°C)
Item
Input
Symbol
Rating
Unit
LED forward current
IF
50
mA
LED forward current
reduction rate
Δ IF/°C
−0.5
mA/°C
LED reverse voltage
VR
5
V
Connection temperature
Tj
125
°C
VOFF
40
V
Output Load voltage (AC peak/DC)
Measurement Conditions
Note:
Ta ≥ 25°C
Continuous load current
IO
300
mA
ON current reduction rate
Δ ION/°C
−3.0
mA/°C
Ta ≥ 25°C
Pulse ON currrent
IOP
900
mA
t=100ms, Duty=1/10
Connection temperature
Tj
125
°C
Dielectric strength between input and VI-O
output (See note 1.)
500
Vrms
AC for 1 min
Ambient operating temperature
Ta
−40 to +85
°C
With no icing or condensation
Ambient storage temperature
Tstg
−40 to +125 °C
With no icing or condensation
Soldering temperature
---
260
°C
1. The dielectric strength between
the input and output was
checked by applying voltage
between all pins as a group on
the LED side and all pins as a
group on the light-receiving side.
10 s
■ Electrical Characteristics (Ta = 25°C)
Item
Input
Minimum
Symbol
LED forward voltage
Typical
Maximum
Measurement
conditions
Unit
VF
1.0
1.15
1.3
V
IF = 10 mA
Reverse current
IR
---
---
10
μA
VR = 5 V
Capacity between terminals
CT
---
15
---
pF
V = 0, f = 1 MHz
IFT
---
0.6
3
mA
IO = 100 mA
RON
---
1.0
1.5
Ω
IF = 5 mA, IO = 300 mA
t<1s
Current leakage when the relay is open
ILEAK
---
---
1
nA
VOFF = 40 V
Capacity between terminals
COFF
---
10
14
pF
V = 0, f = 100 MHz,
t<1s
Trigger LED forward current
Output Maximum resistance with output ON
Capacity between I/O terminals
CI-O
---
0.4
---
pF
f = 1 MHz, Vs = 0 V
Insulation resistance between I/O terminals
RI-O
1,000
---
---
MΩ
VI-O = 500 VDC,
RoH ≤ 60%
Turn-ON time
tON
---
0.2
0.5
ms
Turn-OFF time
tOFF
---
0.2
0.3
ms
IF = 5 mA, RL = 200 Ω,
VDD = 20 V (See note 2.)
■ Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item
Load voltage (AC peak/DC)
Symbol
Minimum
Typical
Maximum
Unit
VDD
---
Operating LED forward current
IF
5
7.5
20
mA
Continuous load current (AC peak/DC)
IO
---
---
300
mA
Operating temperature
Ta
−20
---
65
°C
2
G3VM-41PR5
MOS FET Relays
---
32
V
Note:
2. Turn-ON and Turn-OFF Times
IF
1
4
2
3
RL
VDD
VOUT
IF
VOUT
10%
t ON
90%
t OFF
■ Engineering Data
LED forward current vs.
Ambient temperature
Continuous load current vs.
Ambient temperature
IO - Ta
60
50
40
30
20
10
400
300
200
100
-20
0
20
40
60
80
Continuous load current vs.
On-state voltage
-20
0
Ta=25°C
IF=5mA, t<1s
100
0
-100
-200
20
40
60
80
0.2
0.4
IF=5mA, t<1s
2
1
-20
0
Turn ON, Turn OFF time vs.
LED forward current
40
60
80
100
Io=100mA
t<1s
2
1
0
-40
-20
0
Turn ON, Turn OFF time tON, tOFF (µs)
t OFF
100
t ON
RL=200Ω
Ta=25°C
10
10
100
LED forward current IF (mA)
40
60
80
100
Current leakage vs.
Load voltage
ILEAK - VOFF
1000
tON
t OFF
100
20
Ambient temperature Ta (°C)
tON, tOFF - Ta
tON, tOFF - IF
1.6
3
Ambient temperature Ta (°C)
Turn ON, Turn OFF time vs.
Ambient temperature
1000
1
20
1.4
IFT - Ta
Io=300mA
On-state voltage VON (V)
VDD=20V
1.2
LED forward voltage VF (V)
Current leakage ILEAK (pA)
0
1
Trigger LED forward current vs.
Ambient temperature
3
0
-40
-400
-0.2
0.8
100
-300
-0.4
1
RON - Ta
On-state resistance RON (Ω)
IO - VON
200
10
Ambient temperature Ta (°C)
On-state resistance vs.
Ambient temperature
400
300
Ta=25°C
0.1
-40
100
Ambient temperature Ta (°C)
Trigger LED forward current IFT (mA)
-40
Turn ON, Turn OFF time tON, tOFF (µs)
100
0
0
Continuous load current IO (mA)
IF - VF
LED forward current IF (mA)
Continuous load current IO (mA)
LED forward current IF (mA)
IF - Ta
LED forward current vs.
LED forward voltage
15
Ta=25°C
10
5
VDD=20V
RL=200Ω
IF=5mA
10
0
-40
-20
0
20
40
60
80
100
Ambient temperature Ta (°C)
0
10
20
30
40
Load voltage VOFF (V)
Output terminal capacitance
COFF/COFF(0v) vs. Load voltage
Output terminal capacitance COFF/COFF(0v)
COFF - VOFF
1
0.8
0.6
0.4
0.2
Ta=25°C
0
0
10
20
30
40
50
Load voltage VOFF (V)
MOS FET Relays
G3VM-41PR5
3
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON ON-LINE
Global - http://www.omron.com
USA - http://www.components.omron.com
OMRON ELECTRONIC
COMPONENTS LLC
847-882-2288
Cat. No. K201-E-01
4
MOS FET Relays
03/14
Specifications subject to change without notice
G3VM-41PR5
Printed in USA