MOS FET Relays
G3VM-351A/D
MOS FET Relay Series with 350-V Load Voltage
• Upgraded G3VM-2 Series.
• Continuous load current of 120 mA.
• Dielectric strength of 2,500 Vrms between I/O.
• Operating time of 0.3 ms (typical).
• RoHS Compliant.
■ Application Examples
• Measurement devices
• Security systems
• Amusement machines
Note: The actual product is marked differently from the image shown
here.
■ List of Models
Contact form
SPST-NO
Terminals
Load voltage (peak value)
PCB terminals
350 VAC
Model
G3VM-351A
Surface-mounting
terminals
Number per stick
Number per tape
100
---
---
1,500
G3VM-351D
G3VM-351D(TR)
■ Dimensions
Note: All units are in millimeters unless otherwise indicated.
G3VM-351A
G3VM-351D
4.58±0.25
6.4±0.25
4.58±0.25
6.4±0.25
7.62±0.25
7.62±0.25
0.8±0.25
+0.15
+0.15
3.65 −0.25
3.65 −0.25
Note: The actual product
is marked differently from the image
shown here.
1.2±0.15
2.5 min.
0.5±0.1
2.54±0.25
7.85 to 8.80
Weight: 0.25 g
Note: The actual product
is marked differently from the image
shown here.
4.0 +0.25
−0.2
1.0
min.
+0.1
0.25 −0.05
1.2±0.15
1.0 min.
10.0 max.
2.54±0.25
Weight: 0.25 g
■ Terminal Arrangement/Internal Connections (Top View)
G3VM-351A
4
3
1
2
■ PCB Dimensions (Bottom View)
G3VM-351A
2.54
Four 0.8-dia. holes
(0.61)
G3VM-351D
4
3
1
2
■ Actual Mounting Pad Dimensions
(Recommended Value, Top View)
G3VM-351D
2.54
2.54
8.3 to 8.8
(1.52)
(0.61)
(1.52)
1.3
1.5
MOS FET Relays
G3VM-351A/D
27
■ Absolute Maximum Ratings (Ta = 25°C)
Item
Input
Symbol
Rating
Unit
Measurement conditions
LED forward current
IF
50
mA
Repetitive peak LED forward
current
IFP
1
A
100 μs pulses, 100 pps
LED forward current reduction Δ IF/°C
rate
−0.5
mA/°C
Ta ≥ 25°C
LED reverse voltage
VR
5
V
Tj
125
°C
VOFF
350
V
Continuous load current
IO
120
mA
ON current reduction rate
Δ ION/°C −1.2
Connection temperature
Tj
Connection temperature
Output Load voltage (AC peak/DC)
Note:
1. The dielectric strength between the input and
output was checked by applying voltage between all pins as a group on the LED side and
all pins as a group on the light-receiving side.
Ta ≥ 25°C
mA/°C
125
°C
Dielectric strength between input and VI-O
output (See note 1.)
2,500
Vrms
AC for 1 min
Operating temperature
Ta
−40 to +85
°C
With no icing or condensation
Storage temperature
Tstg
−55 to +125 °C
With no icing or condensation
Soldering temperature (10 s)
---
260
°C
10 s
Minimum
Typical
■ Electrical Characteristics (Ta = 25°C)
Item
Symbol
Maximum
Measurement
conditions
Unit
LED forward voltage
VF
1.0
1.15
1.3
V
IF = 10 mA
Reverse current
IR
---
---
10
μA
VR = 5 V
Capacity between terminals
CT
---
30
---
pF
V = 0, f = 1 MHz
IFT
---
1
3
mA
IO = 120 mA
RON
---
25
35
Ω
IF = 5 mA,
IO = 120 mA, t < 1 s
---
35
50
Ω
IF = 5 mA,
IO = 120 mA
Current leakage when the relay is open ILEAK
---
0.0015
1.0
μA
VOFF = 350 V
Capacity between terminals
COFF
---
30
---
pF
V = 0, f = 1MHz
Capacity between I/O terminals
CI-O
---
0.8
---
pF
f = 1 MHz, Vs = 0 V
Insulation resistance
RI-O
1,000
---
---
MΩ
VI-O = 500 VDC,
RoH ≤ 60%
Turn-ON time
tON
---
0.3
1.0
ms
Turn-OFF time
tOFF
---
0.1
1.0
ms
IF = 5 mA, RL = 200 Ω,
VDD = 20 V (See note 2.)
Input
Trigger LED forward current
Output Maximum resistance with output ON
■ Recommended Operating Conditions
Item
Symbol
Minimum
Typical
Maximum
VDD
---
---
280
Operating LED forward current
IF
Unit
V
5
7.5
25
mA
Continuous load current (AC peak/DC) IO
---
---
100
mA
Operating temperature
− 20
---
65
°C
28
Ta
MOS FET Relays
G3VM-351A/D
2. Turn-ON and Turn-OFF
Times
IF
Use the G3VM under the following conditions so that the Relay will operate properly.
Load voltage (AC peak/DC)
Note:
1
4
2
3
RL
VDD
VOUT
IF
VOUT
10%
t ON
90%
t OFF
■ Engineering Data
LED forward current vs.
Ambient temperature
Continuous load current vs.
Ambient temperature
IO - Ta
80
60
40
20
0
20
40
60
80
100
200
160
120
80
40
0
−20
120
Ambient temperature Ta (ഒ)
0
20
100
0
−100
60
80
100
−1
0
50
1
2
3
40
t<1s
20
0
1
40
60
80
100
Turn ON, Turn OFF time tON, tOFF (μS)
tOFF
100
30
LED forward current IF (mA)
100
1.8
t<1s
4
3
2
1
0
−20
0
20
40
60
80
100
Current leakage vs.
Ambient temperature
I LEAK - Ta
3000
1000
tON
300
100
tOFF
VDD = 20 V
30
100
VOFF = 350 V
30
10
3
1
0.3
RL = 200 Ω
tON
30
1.6
IO = 120 mA
tON, tOFF - Ta
300
1.4
Ambient temperature Ta (ഒ)
Turn ON, Turn OFF time vs.
Ambient temperature
Ta = 25°C
VDD = 20 V
RL = 200 Ω
1000
20
1.2
5
Ambient temperature Ta (ഒ)
tON, tOFF - IF
3000
10
0.8
IFT - Ta
IO = 120 mA
30
0
−20
4
Turn ON, Turn OFF time vs.
LED forward current
3
1
Trigger LED forward current vs.
Ambient temperature
IF = 5 mA
On-state voltage VON (V)
10
1
3
LED forward voltage VF (V)
Current leakage ILEAK (nA)
−2
10
0.1
0.6
120
10
−3
30
RON - Ta
On-state resistance RON (Ω)
Continuous load current IO (mA)
IO - VON
Turn ON, Turn OFF time tON, tOFF (μS)
40
On-state resistance vs.
Ambient temperature
Ta = 25°C
IF = 5 mA
−200
−4
Ta = 25°C
Ambient temperature Taഒ
Continuous load current vs.
On-state voltage
200
100
0.3
Trigger LED forward current I F T (mA)
0
−20
IF - VF
240
LED forward current I F (mA)
100
Continuous load current I O (mA)
LED forward current IF (mA)
IF - Ta
LED forward current vs.
LED forward voltage
IF = 5 mA
300
10
−20
0
20
40
60
80
100
Ambient temperature Ta (ഒ
MOS FET Relays
0.1
−20
0
20
40
60
80
100
Ambient temperature Ta (ഒ)
G3VM-351A/D
29
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON ON-LINE
OMRON ELECTRONIC
COMPONENTS LLC
Global - http://www.omron.com
USA - http://www.components.omron.com
55 E. Commerce Drive, Suite B
Schaumburg, IL 60173
847-882-2288
Cat. No. X302-E-1
MOS FET Relays
12/10
Specifications subject to change without notice
G3VM-351A/D
Printed in USA