MOS FET Relays G3VM-21BR/ER Higher Power, 4A switching with a 20V load, DIP package. Low 20 mΩ ON Resistance. • Continuous load current of 4A (Connection C: 8A) • Switches minute analog signals • Dielectric strength of 2,500 Vrms between I/O • RoHS Compliant ■ Application Examples • Communication equipment and Measurement devices • Security systems and Power circuits • Factory Automation equipment Note: The actual product is marked differently from the image shown here. ■ List of Models Package Type Contact form DIP6 SPST-NO Terminals PCB terminals Load voltage (peak value) 20 V Model Number per stick G3VM-21BR Surface-mounting terminals Number per tape 50 --- --- 1,500 G3VM-21ER G3VM-21ER(TR) Note: The AC peak and DC value are given for the load voltage. ■ Dimensions Note: All units are in millimeters unless otherwise indicated. G3VM-21BR G3VM-21ER 7.12±0.25 7.12±0.25 6.4±0.25 6.4±0.25 7.62±0.25 7.62±0.25 0.8±0.25 3.65+0.15 −0.25 3.65+0.15 −0.25 4.0+0.25 −0.2 0.25+0.1 −0.05 Note: The actual product is marked differently from the image shown here. 2.5 min. 1.2±0.15 0.5±0.1 2.54±0.25 7.85 to 8.80 Weight: 0.4 g 1.0 min. Note: The actual product is marked differently from the image shown here. 1.2±0.15 1.0 min. 10.0 max. 2.54±0.25 Weight: 0.4 g ■ Terminal Arrangement/Internal Connections (Top View) G3VM-21BR G3VM-21ER 6 5 4 6 5 4 OMRON logo Model name 932 Pin 1 mark 1 2 3 1 ■ PCB Dimensions (Bottom View) G3VM-21BR Six, 0.8-dia. holes 2.54 (0.61) 2 3 Lot No. Note: The actual product is marked differently from the image shown here. ■ Actual Mounting Pad Dimensions (Recommended Value, Top View) G3VM-21ER 2.54 2.54 2.54 8.3 to 8.8 (1.52) (0.61) (1.52) 1.3 1.5 MOS FET Relays G3VM-21BR/ER 1 ■ Absolute Maximum Ratings (Ta = 25°C) Item Input Symbol Rating Unit Measurement Conditions LED forward current IF 30 mA Repetitive peak LED forward current IFP 1 A 100 μs pulses, 100 pps LED forward current reduction rate Δ IF/°C −0.3 mA/°C Ta ≥ 25°C LED reverse voltage VR 5 V Tj 125 °C VOFF 20 V A Connection A: AC peak/DC Connection B and C: DC mA/°C Ta ≥ 25°C Connection temperature Output Load voltage (AC peak/DC) Continuous load current ON current reduction rate Connection A IO 4 Connection B 4 Connection C 8 Connection A Δ IIO/°C −40 1. The dielectric strength between the input and output was checked by applying voltage between all pins as a group on the LED side and all pins as a group on the light-receiving side. Connection Diagram Connection A Connection B −40 Connection B −80 Connection C Pulse on current IOP 12 A Connection temperature Tj 125 °C Dielectric strength between input and output (See note 1.) Note: VI-O 2,500 1 6 2 5 3 4 1 6 2 5 3 4 1 6 2 5 3 4 Load AC or DC Load DC t=100 ms, Duty = 1/10 Vrms AC for 1 min Connection C Operating temperature Ta −40 to +85 °C With no icing or condensation Storage temperature Tstg −55 to +125 °C With no icing or condensation Soldering temperature (10 s) --- 260 °C Load DC 10 s ■ Electrical Characteristics (Ta = 25°C) Item Input Minimum Symbol Typical Maximum Measurement conditions Unit LED forward voltage VF 1.18 1.33 1.48 V IF = 10 mA Reverse current IR --- --- 10 μA VR = 5 V Capacity between terminals CT --- 70 --- pF V = 0, f = 1 MHz Trigger LED forward current Note: IF IFT --- 0.5 3 mA RON --- 20 50 mΩ IF = 5 mA, IO = 2 A, t < 1s Connection B --- 10 --- mΩ IF = 5 mA, IO = 2 A, t < 1s Connection C --- 5 --- mΩ IF = 5 mA, IO = 4 A, t < 1s Current leakage when the relay is open ILEAK --- --- 1.0 μA VOFF = 20 V Capacity between terminals COFF --- 1,000 --- pF V = 0, f = 1 MHz Capacity between I/O terminals CI-O --- 0.8 --- pF f = 1 MHz, Vs = 0 V Insulation resistance between I/O terminals RI-O 1,000 --- --- MΩ VI-O = 500 VDC, RoH ≤ 60% Turn-ON time tON --- 2.5 5.0 ms Turn-OFF time tOFF --- 0.1 1.0 ms IF = 5 mA, RL = 200 Ω, VDD = 20 V (See note 2.) Output Maximum resistance with output ON Connection A IO = 1 A ■ Recommended Operating Conditions Item Symbol Minimum Typical Maximum Unit VDD --- --- 16 V Operating LED forward current IF 5 10 25 mA Continuous load current (AC peak/DC) IO --- --- 4 A Operating temperature Ta − 20 --- 65 °C 2 MOS FET Relays G3VM-21BR/ER 1 6 2 4 RL VDD VOUT IF VOUT Use the G3VM under the following conditions so that the Relay will operate properly. Load voltage (AC peak/DC) 2. Turn-ON and Turn-OFF Times 10% t ON 90% t OFF ■ Engineering Data Continuous load current vs. Ambient temperature IO - Ta 40 30 20 10 -20 0 20 40 60 80 10 Connection C 5 0 -40 100 Connection A, Connection B Continuous load current vs. On-state voltage IO - VON 60 80 On-state resistance RON (mΩ) 4 I = 5mA F 3 Connection A 2 1 0 -1 -2 -3 -4 -0.05 0 0.05 20 10 40 60 80 100 Turn ON, Turn OFF time tON, tOFF (mS) t off 0.01 100 10 1 t off 0.1 -20 0 20 40 2.0 IO = 1A t < 1s Connection A 1 0 -40 -20 0 60 80 20 40 60 80 100 Current leakage vs. Ambient temperature I LEAK – Ta 100 VDD = 20V RL = 200Ω IF = 5mA t on 0.01 -40 1.5 Ambient temperature Ta (ഒ) 100 t on LED forward current IF (mA) 20 Turn ON, Turn OFF time vs. Ambient temperature tON, tOFF - Ta 10 10 0 2 Ambient temperature Ta (ഒ) VDD = 20V RL = 200Ω Ta = 25°C 1 -20 1.0 Trigger LED forward current vs. Ambient temperature IFT - Ta 30 0 -40 0.1 Turn ON, Turn OFF time vs. LED forward current tON, tOFF - IF 0.1 0.5 LED forward voltage VF (V) IO = 2A IF = 5mA, t < 1s 40 Connection A On-state voltage VON ( V ) 1 0.1 Current leakage ILEAK (nA) -5 -0.1 1 0.01 0 100 50 Ta = 25°C Continuous load current IO (A) 40 10 On-state resistance vs. Ambient temperature RON - Ta 5 Turn ON, Turn OFF time tON, tOFF (mS) 20 Ta = 25°C Ambient temperature Taഒ Ambient temperature Ta (ഒ) 100 0 -20 100 Trigger LED forward current I F T (mA) 0 -40 LED forward current vs. LED forward voltage IF - VF LED forward current I F (mA) 50 Continuous load current I O (A) LED forward current IF (mA) LED forward current vs. Ambient temperature IF - Ta 100 VOFF = 20V 10 1 0.1 0.01 -40 Ambient temperature Ta (ഒ -20 0 20 40 60 80 100 Ambient temperature Ta (ഒ Precautions Be sure to read the precautions and information common to all G3VM MOS FET relays, contained in the Technical User’s Guide, “MOSFET Relays, Technical Information” for correct use. MOS FET Relays G3VM-21BR/ER 3 All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. OMRON ON-LINE OMRON ELECTRONIC COMPONENTS LLC Global - http://www.omron.com USA - http://www.components.omron.com 55 E. Commerce Drive, Suite B Schaumburg, IL 60173 847-882-2288 Cat. No. K136-E-01 4 MOS FET Relays 07/12 Specifications subject to change without notice G3VM-21BR/ER Printed in USA