MOS FET Relays G3VM-101PR Smallest 100V MOS FET Relay In The Market (USOP Package Size) • Dielectric strength of 500 Vrms between I/O. • RoHS compliant. ■ Application Examples • Semiconductor test equipment • Test & Measurement devices and Data loggers • Communication equipment Note: The actual product is marked differently from the image shown here. ■ List of Models Package type USOP4 Contact form SPST-NO (1FormA) Terminals Load voltage (peak value) Surface-mounting terminals 100 VAC or VDC Model Number per tape G3VM-101PR --- G3VM-101PR(TR05) 500 ■ Dimensions Note: All units are in millimeters unless otherwise indicated. G3VM-101PR 3.25 2PA 103 2.05 0.15 1.65 (0.4) Note: The actual product is marked differently from the image shown here. 0.2 1.27 2.85 2.2 Weight: 0.03 g (0.35) ■ Terminal Arrangement/Internal Connections (Top View) G3VM-101PR AP0 Model name OMRON mark 103 LOT No. Note: The actual product is marked differently from the image shown here. ■ Actual Mounting Pad Dimensions (Recommended Value, Top View) G3VM-101PR 0.85 2.9 0.8 1.27 MOS FET Relays G3VM-101PR 1 ■ Absolute Maximum Ratings (Ta = 25°C) Item Input Symbol Rating Unit LED forward current IF 50 mA LED forward current reduction rate Δ IF/°C −0.5 mA/°C LED reverse voltage VR 5 V Connection temperature Tj 125 °C VOFF 100 V Output Load voltage (AC peak/DC) Measurement Conditions Note: Ta ≥ 25°C Continuous load current IO 100 mA ON current reduction rate Δ ION/°C −1 mA/°C Ta ≥ 25°C Pulse ON currrent IOP 300 mA t=100ms, Duty=1/10 Connection temperature Tj 125 °C Dielectric strength between input and VI-O output (See note 1.) 500 Vrms AC for 1 min Ambient operating temperature Ta −40 to +85 °C With no icing or condensation Ambient storage temperature Tstg −40 to +125 °C With no icing or condensation Soldering temperature --- 260 °C 1. The dielectric strength between the input and output was checked by applying voltage between all pins as a group on the LED side and all pins as a group on the light-receiving side. 10 s ■ Electrical Characteristics (Ta = 25°C) Item Input Minimum Symbol LED forward voltage Typical Maximum Measurement conditions Unit VF 1.0 1.15 1.3 V IF = 10 mA Reverse current IR --- --- 10 μA VR = 5 V Capacity between terminals CT --- 15 --- pF V = 0, f = 1 MHz IFT --- 0.5 3 mA IO = 100 mA RON --- 8 14 Ω IF = 5 mA, IO = 100 mA t<1s Current leakage when the relay is open ILEAK --- --- 200 pA VOFF = 100 V Capacity between terminals COFF --- 6 8 pF V = 0, f = 100 MHz, t<1s Trigger LED forward current Output Maximum resistance with output ON Capacity between I/O terminals CI-O --- 0.4 --- pF f = 1 MHz, Vs = 0 V Insulation resistance between I/O terminals RI-O 1,000 --- --- MΩ VI-O = 500 VDC, RoH ≤ 60% Turn-ON time tON --- 0.12 0.3 ms Turn-OFF time tOFF --- 0.18 0.3 ms IF = 5 mA, RL = 200 Ω, VDD = 20 V (See note 2.) ■ Recommended Operating Conditions Use the G3VM under the following conditions so that the Relay will operate properly. Item Load voltage (AC peak/DC) Symbol Minimum Typical Maximum Unit VDD --- Operating LED forward current IF 5 7.5 20 mA Continuous load current (AC peak/DC) IO --- --- 100 mA Operating temperature Ta −20 --- 65 °C 2 G3VM-101PR MOS FET Relays --- 80 V Note: 2. Turn-ON and Turn-OFF Times IF 1 4 2 3 RL VDD VOUT IF VOUT 10% t ON 90% t OFF ■ Engineering Data LED forward current vs. Ambient temperature Continuous load current vs. Ambient temperature IO - Ta 60 50 40 30 20 10 150 100 50 -20 0 20 40 60 80 Continuous load current vs. On-state voltage -20 0 20 Ta=25°C IF=5mA, t<1s 40 0 -40 40 60 80 -120 1.2 0.5 IF=5mA, t<1s 10 5 -20 0 Turn ON, Turn OFF time vs. LED forward current 20 40 60 80 100 3 Io=100mA t<1s 2 1 0 -40 -20 0 Ambient temperature Ta (°C) Turn ON, Turn OFF time vs. Ambient temperature 20 Turn ON, Turn OFF time tON, tOFF (µs) tOFF 100 VDD=20V RL=200Ω tON Ta=25°C 10 10 100 LED forward current IF (mA) 60 80 100 Current leakage vs. Load voltage ILEAK - VOFF 1000 tON 100 40 Ambient temperature Ta (°C) tON, tOFF - Ta tON, tOFF - IF 1000 1.6 IFT - Ta Io=100mA 0 -40 1 1.4 Trigger LED forward current vs. Ambient temperature 15 On-state voltage VON (V) 1 1 LED forward voltage VF (V) Current leakage ILEAK (pA) 0 0.8 100 -80 -0.5 1 RON - Ta On-state resistance RON (Ω) IO - VON -1 10 Ambient temperature Ta (°C) On-state resistance vs. Ambient temperature 120 80 Ta=25°C 0.1 -40 100 Ambient temperature Ta (°C) Trigger LED forward current IFT (mA) -40 Turn ON, Turn OFF time tON, tOFF (µs) 100 0 0 Continuous load current IO (mA) IF - VF LED forward current IF (mA) Continuous load current IO (mA) LED forward current IF (mA) IF - Ta LED forward current vs. LED forward voltage tOFF VDD=20V 100 Ta=25°C 80 60 40 20 RL=200Ω IF=5mA 10 0 -40 -20 0 20 40 60 80 100 Ambient temperature Ta (°C) 0 20 40 60 80 100 Load voltage VOFF (V) Output terminal capacitance COFF/COFF(0v) vs. Load voltage Output terminal capacitance COFF/COFF(0v) COFF - VOFF 1.2 1 0.8 0.6 0.4 0.2 Ta=25°C 0 0 10 20 30 40 Load voltage VOFF (V) MOS FET Relays G3VM-101PR 3 All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. OMRON ON-LINE Global - http://www.omron.com USA - http://www.components.omron.com OMRON ELECTRONIC COMPONENTS LLC 847-882-2288 Cat. No. K219-E-01 4 MOS FET Relays 03/14 Specifications subject to change without notice G3VM-101PR Printed in USA