3C96 - Ferroxcube

FERROXCUBE
DATA SHEET
3C96
Material specification
Supersedes data of September 2004
2008 Sep 01
Ferroxcube
Material specification
3C96
3C96 SPECIFICATIONS
A low to medium frequency power material for use in
power and general purpose transformers at frequencies
up to 0.4 MHz.
CONDITIONS
µi
µa
B
PV
ρ
TC
density
VALUE
2000 ±20%
25 °C; 10 kHz;
1200 A/m
100 °C; 10 kHz;
1200 A/m
100 °C; 100 kHz;
100 mT
100 °C; 100 kHz;
200 mT
100 °C; 500 kHz;
50 mT
DC; 25 °C
≈ 500
µ''s
mT
10 2
≈ 440
≈ 40
kW/m3
10
10 1
≈ 300
1
10
f (MHz)
10 2
≈ 250
≈5
≥ 240
≈ 4800
Ωm
°C
kg/m3
Fig.1
CBW447
10000
Complex permeability as
a function of frequency.
CBW438
500
25 oC
100 oC
handbook, halfpage
3C96
B
(mT)
µi
8000
400
6000
300
4000
200
2000
100
3C96
0
50
Fig.2
2008 Sep 01
µ's
10 3
≈ 5500
handbook, halfpage
0
50
3C96
µ's , µ''s
UNIT
25 °C; ≤10 kHz;
0.25 mT
100 °C; 25 kHz;
200 mT
CBW573
10 4
handbook, halfpage
150
T ( o C)
250
25
0
25
50
150
250
H (A/m)
Initial permeability as a
function of temperature.
Fig.3 Typical B-H loops.
129
Ferroxcube
Material specification
3C96
CBW440
8000
25 oC
o
100 C
handbook, halfpage
µa
CBW576
10 4
handbook, halfpage
3C96
3C96
µ rev
6000
10 3
4000
10 2
2000
0
10
0
100
200
300
400
Fig.4
Amplitude permeability as a
function of peak flux density.
Fig.5
CBW453
10 4
kH
500
f
B
(kHz) (mT)
600
25
kHz
10 3
CBW472
3C96
Pv
(kW/m 3 )
200
kHz
100
kHz
(kW/m 3)
Reversible permeability as a
function of magnetic field strength.
800
z
T = 100 C
Pv
3
H (A/m) 10
handbook, halfpage
3C96
o
10 2
10
1
B (mT)
400
100
200
200
100
25
100
200
100
10 2
200
0
10
1
10
10 2
B (mT)
0
10 3
Fig.7
Fig.6
Specific power loss as a function of peak
flux density with frequency as a parameter.
2008 Sep 01
130
40
80
T (o C)
120
Specific power loss for several
frequency/flux density combinations
as a function of temperature.
Ferroxcube
Material specification
3C96
DATA SHEET STATUS DEFINITIONS
DATA SHEET
STATUS
PRODUCT
STATUS
DEFINITIONS
Preliminary
specification
Development
This data sheet contains preliminary data. Ferroxcube reserves the right to
make changes at any time without notice in order to improve design and
supply the best possible product.
Product specification
Production
This data sheet contains final specifications. Ferroxcube reserves the right
to make changes at any time without notice in order to improve design and
supply the best possible product.
DISCLAIMER
Life support applications  These products are not designed for use in life support appliances, devices, or systems
where malfunction of these products can reasonably be expected to result in personal injury. Ferroxcube customers
using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Ferroxcube
for any damages resulting from such application.
PRODUCT STATUS DEFINITIONS
STATUS
INDICATION
DEFINITION
Prototype
These are products that have been made as development samples for the purposes of
technical evaluation only. The data for these types is provisional and is subject to
change.
Design-in
These products are recommended for new designs.
Preferred
These products are recommended for use in current designs and are available via our
sales channels.
Support
These products are not recommended for new designs and may not be available
through all of our sales channels. Customers are advised to check for availability.
2008 Sep 01
131