3C95 - Ferroxcube

FERROXCUBE
DATA SHEET
3C95
Material specification
New data
2008 Sep 01
Ferroxcube
Material specification
3C95
3C95 SPECIFICATIONS
A low to medium frequency power material with low
power losses from 25 to 100 °C for use in power
transformers at frequencies up to 0.5 MHz. Especially
suited for broad temperature range applications like
automotive, lighting and mobile / handheld.
MFP124
10000
handbook, halfpage
3C95
µi
SYMBOL
µi
CONDITIONS
VALUE
25 °C; ≤10 kHz;
0.25 mT
100 °C; 25 kHz;
200 mT
25 °C; 10 kHz;
1200 A/m
100 °C; 10 kHz;
1200 A/m
25 °C; 100 kHz;
200 mT
100 °C; 100 kHz;
200 mT
DC, 25 °C
µa
B
PV
ρ
TC
density
UNIT
8000
3000 ± 20 %
6000
≈ 5000
≈ 530
mT
4000
≈ 410
2000
≈ 350
kW/m 3
0
50
≈ 290
≈5
≥ 215
≈ 4800
Ωm
°C
kg/m3
50
Fig.1
150
B
(mT)
MFP126
8000
25 oC
100 oC
25 oC
o
100 C
handbook, halfpage
3C95
µa
400
250
Initial permeability as a
function of temperature.
MFP125
500
T ( o C)
3C95
6000
300
4000
200
2000
100
0
0
25
0
25
50
150
0
250
Fig.2
2008 Sep 01
100
200
300
400
B (mT)
H (A/m)
Fig.3 Amplitude permeability as a
function of peak flux density.
Typical B-H loops.
125
Ferroxcube
Material specification
3C95
MFP127
104
MFP128
800
handbook, halfpage
3C95
T = 100 °C
Pv
400
kHz
200
kHz
100
kH z
(kW/m3)
103
3C95
Pv
(kW/m 3 )
f
B
(kHz) (mT)
600
400
100
200
200
400
100
50
100
100
102
200
10
1
10
102
^
B (mT)
0
103
0
Fig.5
Fig.4
Specific power loss as a function of peak
flux density with frequency as a parameter.
2008 Sep 01
126
40
80
120
T (o C)
Specific power loss for several
frequency/flux density combinations
as a function of temperature.
Ferroxcube
Material specification
3C95
DATA SHEET STATUS DEFINITIONS
DATA SHEET
STATUS
PRODUCT
STATUS
DEFINITIONS
Preliminary
specification
Development
This data sheet contains preliminary data. Ferroxcube reserves the right to
make changes at any time without notice in order to improve design and
supply the best possible product.
Product specification
Production
This data sheet contains final specifications. Ferroxcube reserves the right
to make changes at any time without notice in order to improve design and
supply the best possible product.
DISCLAIMER
Life support applications  These products are not designed for use in life support appliances, devices, or systems
where malfunction of these products can reasonably be expected to result in personal injury. Ferroxcube customers
using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Ferroxcube
for any damages resulting from such application.
PRODUCT STATUS DEFINITIONS
STATUS
INDICATION
DEFINITION
Prototype
These are products that have been made as development samples for the purposes of
technical evaluation only. The data for these types is provisional and is subject to
change.
Design-in
These products are recommended for new designs.
Preferred
These products are recommended for use in current designs and are available via our
sales channels.
Support
These products are not recommended for new designs and may not be available
through all of our sales channels. Customers are advised to check for availability.
2008 Sep 01
127